Skip to main content

Devon James Godfrey

Associate Professor of Radiation Oncology
Radiation Oncology
Box 3295 Med Ctr, DUMC, Durham, NC 27710
Radiation Oncology, Physics, Box 3295, DUMC, Durham, NC 27710

Scholarly Works - Conferences


A Deep Learning-Based Computer Aided Detection (CAD) System for Difficult-to-Detect Brain Metastases (BM)

Conference INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS · November 1, 2022 Link to item Cite

Dosimetric Predictors of Toxicity in Patients With Early-Stage Prostate Cancer Treated With Moderately Hypofractionated IMRT or PBT: A Multi-Institutional Analysis.

Conference International journal of radiation oncology, biology, physics · November 2021 Purpose/objective(s)Limited published data address modifiable risk factors for significant toxicity complicating moderately hypofractionated schedules of intensity-modulated radiation therapy (IMRT) and proton-beam therapy (PBT) in patients with e ... Full text Cite

The Impact of Biologically Equivalent Dose on Tumor Control in Unresectable Hepatocellular Carcinoma

Conference International Journal of Radiation Oncology*Biology*Physics · October 2017 Full text Cite

SU‐E‐J‐153: Tracking Respiratory Motion in CBCT Projection Images Using an Integrated Optical Flow (IOF) Method

Conference Medical Physics · January 1, 2011 Purpose: To introduce and evaluate a new method for automatically extracting respiratory phase information directly from CBCT or tomosynthesis projection data. Methods: In the proposed method, the Black and Anandan dense optical flow is computed in the lon ... Full text Cite

MO‐D‐BRC‐07: Reducing Artifacts in Cone‐Beam CT Images Caused by the Presence of An Array Used for Tracking Transponders during Radiotherapy

Conference Medical Physics · January 1, 2011 Purpose: To compare two methods for reducing artifacts in cone‐beam CT (CBCT) images caused by the presence of an electromagnetic array used for tracking transponders during radiotherapy. Methods: A pelvis phantom was imaged using a gantry mounted CBCT sys ... Full text Cite

SU‐GG‐I‐24: Improving IGRT Efficiency Using GPU‐Based Ultrafast Reconstruction of DTS/CBCT and DRR

Conference Medical Physics · January 1, 2010 Purpose: One challenge of on‐line image‐guided radiation therapy is requirement of immediate availability of reconstructed 3D or 4D images for evaluation. This study is to develop a highly data‐parallel version and platform of accelerating reconstruction f ... Full text Cite

TH‐A‐211A‐01: Digital Tomosynthesis for Target Localization

Conference Medical Physics · January 1, 2009 Any deviation between treated and planned volumes for 3‐D conformal therapy, such as IMRT, may cause an adverse clinical outcome. It is therefore critical to minimize all potential deviations using an on‐board (or real‐time) imaging procedure immediately p ... Full text Cite

A Novel Digital Tomosynthesis (DTS) Reconstruction Method using Prior Information and a Deformation Model

Conference International Journal of Radiation Oncology*Biology*Physics · September 2008 Full text Cite

SU‐GG‐I‐52: Conversion of On‐Board Digital TomoSynthesis (DTS) to HU Values

Conference Medical Physics · January 1, 2008 Purpose: To investigate a method to convert the pixel values of DTS images to HU values with reference HU values from CT images. Method and Materials: This study included CT and DTS images of two phantoms (Catphan and a chest phantom) and three patients (p ... Full text Cite

SU‐GG‐J‐119: Localization Accuracy of Target Verification System Using Digitial Tomosynthesis (DTS)

Conference Medical Physics · January 1, 2008 Purposes: A research platform was developed for target verification using digital tomosynthesis (DTS). To verify its accuracy, a phantom study was conducted and several clinical cases were investigated. Method and Materials: customer‐developed reconstructi ... Full text Cite

SU‐GG‐J‐93: Feasibility Study On Artifact Reduction Using Dual Energy Digital Tomosynthesis

Conference Medical Physics · January 1, 2008 Purpose: We propose a simulation study to examine the feasibility of incorporating dual energy (DE) subtraction with digital tomosynthesis (DTS) to help reduce DTS reconstruction artifacts. Method and Materials: We have previously investigated the incorpor ... Full text Cite

SU‐GG‐I‐53: The Impact of Scan Angles On the Visibility of Anatomy in On‐Board Digital Tomosynthesis (DTS) Images for Head and Neck Cancer Patients: A Single‐Observer Study

Conference Medical Physics · January 1, 2008 Purpose: To assess the impact of scan angles on the visibility of anatomy in on‐board digital tomosynthesis (DTS) images as a means to optimize this technique. Method and Materials: Head and neck cancer patients undergoing intensity‐modulated radiotherapy ... Full text Cite

TU‐EE‐A3‐03: On‐Board Four‐Dimensional Digital Tomosynthesis (4D‐DTS): Optimization of Respiratory Motion Dependent Acquisition and Reconstruction Parameters

Conference Medical Physics · January 1, 2008 Purpose: Amplitude and period of respiratory motion vary among patients. For four‐dimensional digital tomosynthesis (4D‐DTS), the frequency of projection acquisition and the phase window must be optimized based on respiratory motion. The purpose of this st ... Full text Cite

TH‐D‐351‐02: A Novel Digital Tomosynthesis (DTS) Reconstruction Method Using Prior Information and a Deformation Model

Conference Medical Physics · January 1, 2008 Purpose: Digital Tomosynthesis (DTS) is a quasi‐3D imaging technique which reconstructs images from a limited angle of on‐board projections with significantly lower dose and shorter acquisition time than full cone‐beam CT (CBCT). However, DTS images recons ... Full text Cite

SU‐GG‐J‐94: Feasibility Study On the Efficacy of Dual Energy Cine Imaging in Radiation Therapy for Lung Cancer

Conference Medical Physics · January 1, 2008 Purpose: Modern IMRT plans have necessitated improved image localization techniques. In the lungs, internal target volumes (ITVs) are often generated from 4DCT images; however, the patient must be properly localized daily for this to work effectively. In t ... Full text Cite

A Preliminary Investigation of Dual Energy (DE) Subtraction Imaging for Improved Soft-Tissue Localization in the Pelvis

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

A Preliminary Investigation of Dual Energy Subtraction Imaging for Improved Target Localization in the Thorax

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

Clinical Evaluation of Digital Tomosynthesis for Target Localization in Breath-Hold Liver Treatment

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

The Effect of Scan Angle on Target Localization Accuracy Using Digital Tomosynthesis

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

Implementation of Digital Tomosynthesis for On-Board Target Localization of Radiotherapy

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

SU‐FF‐J‐58: Clinical Evaluation Using Digital Tomosynthesis for Positioning Verification of Breath‐Hold Liver Treatment

Conference Medical Physics · January 1, 2007 Purpose: To demonstrate clinical feasibility of generating digital tomosynthesis (DTS) in a single breath‐hold (BH) period compared to multiple BH periods for CBCT acquisition and to examine on‐board BH‐DTS as an efficient alternative to BH‐CBCT for target ... Full text Cite

WE‐E‐AUD‐04: Radiation Characteristics and Hypo‐Fractionation Dose Response for the DVS Implantable MOSFET Dosimeter

Conference Medical Physics · January 1, 2007 Purpose: Evaluation of the radiation characteristics and performance of the DVS® implantable MOSFET dosimeter for typical and hypo‐fractionated protocols. Method and Materials: The commercially available DVS is calibrated for use in the range of 150–250 cG ... Full text Cite

SU‐FF‐J‐54: A Hybrid Multiresolution Method for Automatic Registration Between Reference and On Board Digital Tomosynthesis

Conference Medical Physics · January 1, 2007 Purpose: Automatic registration between reference and on‐board digital tomosynthesis (DTS) is a critical step for target localization using DTS. We previously developed an approximate method for automatic registration between reference and on‐board DTS, in ... Full text Cite

SU‐FF‐I‐39: Development of Clinical Application Platform Using Digital Tomosynthesis for Target Localization

Conference Medical Physics · January 1, 2007 Purpose: To develop a workstation for clinical application of digital tomosynthesis (DTS) for real‐time target localization. Specifically, to accelerate the reconstruction both digitally‐reconstructed radiograph (DRR) and DTS using ultra‐fast interpolation ... Full text Cite

WE‐E‐M100F‐01: 3D Interfraction Position Verification for Patients Undergoing Partial Breast Irradiation: Comparing Digital Tomosynthesis to Cone‐Beam CT

Conference Medical Physics · January 1, 2007 Purpose: This clinical study evaluates digital tomosynthesis (DTS) technology for daily imaging guidance for partial breast irradiation (PBI) and compares its positioning accuracy to the 3D CBCT technique. Compared to CBCT, DTS offers lower imaging dose an ... Full text Cite

1025

Conference International Journal of Radiation Oncology*Biology*Physics · November 2006 Full text Cite

2726

Conference International Journal of Radiation Oncology*Biology*Physics · November 2006 Full text Cite

TH‐C‐330A‐05: Analysis of the Point Spread Function of Isocentric Digital Tomosynthesis (DTS)

Conference Medical Physics · January 1, 2006 Purpose: This project presents an analysis of the point spread function (PSF) of isocentric digital tomosynthesis (DTS). DTS is a limited angle 3‐ dimensional reconstruction from cone beam projections, with high resolution for excellent imaging of both bon ... Full text Cite

SU‐FF‐I‐19: A Study of Megavoltage Beam Tomosynthesis

Conference Medical Physics · January 1, 2006 Purpose: To study the impact of projection numbers on the quality of tomosynthesis images using megavoltage beams. Method and Materials: It has been shown that isocentric kilovoltage tomosynthesis images can be generated with no more than 50 degree scan an ... Full text Cite

TH‐C‐ValB‐04: Evaluation of the Quality of 3D‐3D Mutual Information (MI) Shared Between Reference and On‐Board DTS Images

Conference Medical Physics · January 1, 2006 Purpose: Digital tomosynthesis (DTS) is a fast, low‐dose method for reconstructing 3‐D slices from 2‐D cone‐beam x‐ray projection data acquired with limited source angulation (e.g., 40°). We previously developed a method for reconstructing reference DTS (R ... Full text Cite

SU‐CC‐ValA‐01: Automatic Comparison Between Reference and On Board Digital Tomosynthesis for Target Localization

Conference Medical Physics · January 1, 2006 Purpose: Digital tomosynthesis (DTS) is a method for reconstructing 3D images from cone‐beam projection data acquired with limited angulation (e.g., 40°) of an x‐ray source, and is much faster and lower dose than full cone‐beam CT (CBCT). We previously dev ... Full text Cite

MO‐A‐224C‐01: Daily Localization I: KV/CBCT

Conference Medical Physics · January 1, 2006 Daily target localization is a critical step to secure accurate delivery for 3‐D conformal radiation therapy and intensity‐modulated radiation therapy. One emerging technology using in‐room kilovoltage (kV) imaging has shown to be very promising for target ... Full text Cite

SU‐FF‐J‐118: Respiration Phase‐Based Cone‐Beam Computed Tomography (CBCT) Reconstruction

Conference Medical Physics · January 1, 2006 Purpose: To develop a method to reconstruct CBCT data based on projection data acquired at a specific respiration phase. Methods and Materials: The original projection data were acquired using an on‐board imager (OBI) (Varian Medical Systems) over scanning ... Full text Cite

Assessment of Setup Accuracy for Prostate Radiotherapy using On-board Imaging and Cone Beam Computed Tomography

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

Online Digital Tomosynthesis (DTS): A Novel Technique for Improving Target Localization in Radiation Therapy

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

SU‐FF‐J‐57: Digital Tomosynthesis for Verification of Radiation Therapy Positioning: Preliminary Results From a Kilovoltage On‐Board Imaging System

Conference Medical Physics · January 1, 2005 Purpose: This study introduces a new radiation therapy target localization technique using online digital tomosynthesis (DTS), a method for reconstructing 3‐D slices from 2‐D projection data acquired with limited source motion. By separating the visualizat ... Full text Cite

Tomosynthesis imaging of the chest

Conference MEDICAL PHYSICS · June 2003 Link to item Cite