ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2025
Positron emission tomography-computed tomography (PET-CT) is a frequently used multimodality imaging technique. PET scans utilize a radioactive tracer to record metabolic activity, and CT scans provide anatomical information through x-ray attenuation. The ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2025
Osteoporosis is a prevalent but underdiagnosed condition that significantly increases fracture risk, leading to substantial healthcare costs. Dual-energy X-ray absorptiometry (DEXA) remains the gold standard for areal bone mineral density (aBMD) assessment ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2025
Computed tomography (CT) dose and image quality data exhibit a large variability even for the same patient size. That is so despite the tube current modulation (TCM) systems adjusting radiation exposure according to patient body habitus to achieve consiste ...
Full textCite
ConferenceProc SPIE Int Soc Opt Eng · February 2024
Parametric response mapping (PRM) is a voxel-based quantitative CT imaging biomarker that measures the severity of chronic obstructive pulmonary disease (COPD) by analyzing both inspiratory and expiratory CT scans. Although PRM-derived measurements have be ...
Full textLink to itemCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2024
Virtual Imaging Trials, known as VITs, provide a computational substitute for clinical trials. These traditional trials tend to be sluggish, costly, and frequently deficient in definitive evidence, all the while subjecting participants to ionizing radiatio ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2024
Virtual imaging trials of malignancies require realistic models of lesions. The purpose of this study was to create hybrid lesion models and associated tool incorporating morphological and textural realism. The developed tool creates a lesion morphology ba ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2024
Dynamic chest radiography (DCR) enables the evaluation of lung function based on changes in lung density, lung area, and diaphragm level due to respiration. The need for lung segmentation techniques for sequential chest images is growing. Thus, this study ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2024
The measurements of bone macro- and microstructures provide major insight into bone health and risk fracture. The accuracy of these measurements is limited when Conventional CT is used. However, CT technology has advanced with the introduction of photon-co ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2024
Photon-counting CT (PCCT) is an emerging x-ray spectral imaging technology. There are several PCCT prototypes available for clinical and experimental applications. Despite many published results, objective quantitative evaluation of PCCT systems remains ch ...
Full textCite
Conference · November 26, 2023
Purpose. We recently developed a mathematical model to balance radiation risk and clinical risk, namely the risk of misdiagnosis due to insufficient image quality. In this work, we applied this model to a population of one million CT imaging cases to evalu ...
Open AccessCite
Conferencehttps://aapm.onlinelibrary.wiley.com/doi/epdf/10.1002/mp.16525 · July 23, 2023
Achieving consistent and sufficient hepatic parenchyma contrast enhancement (HPCE) level can improve diagnostic performance and reduce enhancement variability; this raises the baseline image quality and optimize injection practices, both carries economic a ...
Full textOpen AccessLink to itemCite
Conferencehttps://aapm.onlinelibrary.wiley.com/doi/epdf/10.1002/mp.16525 · July 23, 2023
Purpose
Noise magnitude is a main CT image quality indicator. In vivo measurements emerged as a patient-specific methodology to assess and qualify CT noise, yet methods to do so vary. Current noise measurement methods in soft tissues and air surrounding t ...
Full textOpen AccessLink to itemCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2023
Pulmonary emphysema is a form of Chronic Obstructive Pulmonary Disease (COPD) and a chronic lung condition that results in a breakdown of alveoli walls. Quantitative Computed Tomography (CT) is increasingly used to assess the presence or progression of emp ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2023
Prediction of pleural invasion in lung cancer is crucial in planning appropriate operating procedures and can be assessed using dynamic chest radiography (DCR). However, this assessment is negatively affected by rib shadows in conventional images. The purp ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2023
Deep learning methods have performed superiorly to segment organs of interest from Computed Tomography images than traditional methods. However, the trained models do not generalize well at the inference phase, and manual validation and correction are not ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Several methods have been introduced over the years to measure CT image noise magnitudes in vivo applying different image segmentation strategies, HU thresholds, and regions of interests in which the noise is calculated. Therefore, it is impossible to dire ...
Full textOpen AccessCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Organ segmentation of medical images is a key step in virtual imaging trials. However, organ segmentation datasets are limited in in terms of quality (because labels cover only a few organs) and quantity (since case numbers are limited). In this study, we ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Photon-counting CT (PCCT) is an emerging CT technology that uses photon-counting detectors (PCDs) to offer better spatial resolution, higher contrast, lower noise, and material-specific imaging as compared to conventional energy-integrating CT. To study th ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Cardiac CT imaging is invaluable in a variety of applications including non-invasive assessment of coronary artery calcifications, the ruling out of acute coronary artery syndrome, and the planning of valve replacement procedures. Newer applications includ ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Ventilatory impairment is detected as decreased changes in lung density during respiration in dynamic chest radiography (DCR). The purpose of this study was to determine optimum imaging conditions in pediatric DCR through a virtual imaging trial (VIT). An ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Many published studies use deep learning models to predict COVID-19 from chest x-ray (CXR) images, often reporting high performances. However, the models do not generalize well on independent external testing. Common limitations include the lack of medical ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Research studies of artificial intelligence models in medical imaging have been hampered by poor generalization. This problem has been especially concerning over the last year with numerous applications of deep learning for COVID-19 diagnosis. Virtual imag ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
The aim of this study was to evaluate and optimize the imaging parameters of a new dual-source photon-counting CT (PCCT) scanner (NAEOTOM Alpha, Siemens Healthineers) for lung lesion radiomics using virtual imaging trials. Virtual patients (XCAT phantoms) ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
Tube current modulation (TCM) is routinely implemented in clinical CT imaging. By modifying the x-ray tube current as a function of patient attenuation, image quality can be made more consistent and radiation dose can be better managed. Optimal TCM setting ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
Radiomic features extracted from CT imaging can be used to quantitively assess COVID-19. The objective of this work was to extract and analyze radiomics features in RT-PRC confirmed COVID-19 cases to identify relevant characteristics for COVID-19 diagnosis ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
Signal separability is an important factor in the differentiation of materials in spectral computed tomography. In this work, we evaluated the separability of two such materials, iodine and gadolinium with k-edges of 33.1 keV and 50.2 keV, respectively, wi ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
Medical images can vary due to differences in imaging equipment and conditions. This variability negatively can impact the consistency and accuracy of diagnostic processes. Hence, it is critical to decrease the variability in image acquisition to achieve c ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
COPD is the fourth leading cause of death in the United States. The structural and functional attributes of this disease can be assessed in vivo using computed tomography (CT). The value of quantitative CT has been demonstrated towards characterization and ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
TWe aimed to estimate respiratory changes in lung volumes (i"lung volume) using frontal and lateral dynamic chest radiography (DCR) by employing a convolutional neural network (CNN) learning approach trained and tested using the four-dimensional (4D) exten ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
In this work, we define a theoretical approach to characterizing the signal-to-noise ratio (SNR) of multi-channeled systems such as spectral computed tomography image series. Spectral image datasets encompass multiple near-simultaneous acquisitions that sh ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
Cardiovascular disease is a leading cause of death worldwide. Among all cardiovascular diseases, coronary artery disease (CAD) is a major contributor to mortality, accounting for approximately 10% of deaths per annum. Imaging techniques such as computed to ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
The accuracy and variability of quantifications in Computed Tomography Angiography (CTA) are affected by imaging parameters and patient attributes. While patient attributes cannot usually be altered for a scan, imaging parameters can be optimized to improv ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
Pulmonary impairments are observed as decreased changes in lung density during respiration on dynamic chest radiographs (DCR). To facilitate pulmonary function evaluation based on DCR, the present study was conducted to correlate respiratory changes in pix ...
Full textCite
Conference · December 2, 2020
PURPOSE
Virtual imaging trial is a unique framework that can greatly facilitate the assessment and optimization of imaging, by emulating the experiments using representative models of patients and scanners. This study aimed to impalement and demonstrate a ...
Cite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2020
In photon-counting CT, detector energy thresholds directly affect image quality attributes such as contrast and noise. The purpose of this study was to identify optimum energy thresholds using a comprehensive virtual clinical trial platform. The virtual tr ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2020
As medical imaging technologies continue to accelerate in complexity, application, and multiplicity of design choices and use features, they should ideally be evaluated and optimized through human clinical trials. However, such trials are often impossible ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2020
The purpose of this study was to develop, validate, and evaluate a method for measuring noise texture directly from patient CT images (i.e., “in vivo”). The method identifies target regions within patient scans which are least likely to have major contribu ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2020
We aimed to investigate the feasibility of predicting pleural invasion or adhesion of lung cancers with dynamic chest radiography (DCR), using a four-dimensional (4D) extended cardiac-torso (XCAT) computational phantom. An XCAT phantom of an adult man (50< ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2019
Previous studies have shown that many factors including body habitus, sex, and age of the patient, as well as contrast injection protocol contribute to the variability in contrast-enhanced cross-sectional imaging (i.e., CT). We have previously developed a ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2019
This study modeled a framework for virtual human liver phantoms, focusing primarily on the intricate vascular networks that comprise the liver. Large vasculature was segmented from clinical liver perfusion images to ascertain a general starting point for t ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2019
The purpose of this study was to examine the effect of energy threshold selection on the quantification of contrast agents in photon-counting CT (PCCT). A phantom was devised consisting of vials of iodine (4, 8, 16 mg/mL), gadolinium (4, 8, 16 mg/mL), and ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2019
This study was performed to investigate the detection performance of trapped air in dynamic chest radiography using 4D extended cardiac-torso (XCAT) phantom with a user-defined ground truth. An XCAT phantom of an adult male (50th percentile in height and w ...
Full textCite
Conference · November 25, 2018
PURPOSE
To develop an effective and automated methodology for patient-specific image quality assessment of clinical pediatric body CT examinations.
METHOD AND MATERIALS
This IRB approved study evaluated 816 clinically performed (6/14-11/17), contrast-enh ...
Cite
Conference · November 25, 2018
PURPOSE
To apply an automated program for evaluating pediatric body CT study quality which utilizes metrics of dose and image quality for optimization of liver lesion detection.
METHOD AND MATERIALS
With IRB approval, 880 clinical contrast-enhanced abdom ...
Cite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2018
Although non-linear CT systems offer improved image quality over conventional linear systems, they disrupt certain assumptions of the dependency of noise and resolution on radiation dose that are true of linear systems. As such, simplistic phantoms do not ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2018
This study aimed to develop a simulation framework to synthesize accurate and scanner-specific Computed Tomography (CT) images of voxel-based computational phantoms. Two phantoms were used in the simulations, a geometry-based Mercury phantom and a "texture ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2018
The purpose of this study was to assess the bias (objectivity) and variability (robustness) of computed tomography (CT) texture features (internal heterogeneities) across a series of image acquisition settings and reconstruction algorithms. We simulated a ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2018
Lesion simulation programs can be used to insert realistic, generated lesions into anatomical images for further study. Most lesion simulation programs rely on insertion of a mask within an otherwise unchangeable, i.e., static surrounding - in reality, les ...
Full textCite
ConferenceMedical Physics · June 30, 2017
Purpose: To develop a robust and accurate automated solution for measuring image noise, spatial resolution, contrast, and radiation dose using clinical patient CT images. Methods: An automated infrastructure has been developed to measure the image quality ...
Cite
ConferenceMedical Physics · June 30, 2017
Purpose: Iodinated contrast agents are commonly used in computed tomography (CT) to delineate vasculature and blood perfusion by enhancement of Hounsfield unit values. Contrast-enhancement is affected by anatomical and physiological factors, and varies acr ...
Cite
ConferenceMedical Physics · June 30, 2017
Purpose: Current radiation dose estimation for CT localizer exams report a single CTDIvol value. Localizer exams with the same CTDIvol can be
acquired as AP, PA, or lateral geometries, each of which carry different radiation burdens. The Purpose of this st ...
Cite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2017
This study aimed to model virtual human lung phantoms including both non-parenchymal and parenchymal structures. Initial branches of the non-parenchymal structures (airways, arteries, and veins) were segmented from anatomical data in each lobe separately. ...
Full textCite
Conference2015 22nd Iranian Conference on Biomedical Engineering Icbme 2015 · February 9, 2016
Response to Bevacizumab in Glioblastoma Multiforme (GBM) is not the same for all patients who receive this antiangiogenic therapy. In this research, structural magnetic resonance images (MRI), Diffusion Tensor Images (DTI), and Dynamic Susceptibility Contr ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2016
The purpose of this study was to substantiate the interdependency of image quality, radiation dose, and contrast material dose in CT towards the patient-specific optimization of the imaging protocols. The study deployed two phantom platforms. First, a vari ...
Full textCite