Skip to main content

Fang-Fang Yin

Gustavo S. Montana Distinguished Professor Emeritus of Radiation Oncology
Radiation Oncology
Box 3295 DUMC, Durham, NC 27710
Radiation Physics, Durham, NC 27710
Office hours call 919-6602185  

Scholarly Works - Conferences


A radiomics-boosted deep-learning model for COVID-19 and non-COVID-19 pneumonia classification using chest x-ray images.

Conference Med Phys · May 2022 PURPOSE: To develop a deep learning model design that integrates radiomics analysis for enhanced performance of COVID-19 and non-COVID-19 pneumonia detection using chest x-ray images. METHODS: As a novel radiomics approach, a 2D sliding kernel was implemen ... Full text Link to item Cite

Transfer learning for fluence map prediction in adrenal stereotactic body radiation therapy.

Conference Phys Med Biol · December 6, 2021 Objective:To design a deep transfer learning framework for modeling fluence map predictions for stereotactic body radiation therapy (SBRT) of adrenal cancer and similar sites that usually have a small number of cases.Approach:We developed a transfer learni ... Full text Link to item Cite

A Dosimetric Study Comparing Two Beam Arrangement Strategies in Fractionated Thoracic Spine Stereotactic Body Radiotherapy (SBRT) Planning.

Conference International journal of radiation oncology, biology, physics · November 2021 Purpose/objective(s)To compare dosimetric results of two beam arrangement strategies and their robustness to setup uncertainties in fractionated thoracic spine Stereotactic Body Radiotherapy (SBRT) MATERIALS/METHODS: Fifteen patients who received ... Full text Cite

Radiomics and Outcome Prediction

Conference MEDICAL PHYSICS · June 2021 Link to item Cite

RETRACTED: An Encoder-Decoder Based Deep Learning AI agent for Spatial Dose Distribution Prediction: A Study of Complex Head-and-Neck IMRT Application

Conference International journal of radiation oncology, biology, physics · November 1, 2020 This article has been retracted: please see Elsevier Policy on Article Withdrawal (http://www.elsevier.com/locate/withdrawalpolicy). This abstract has been retracted at the request of the authors. After submitting this abstract the authors realized that th ... Full text Cite

Dose-Distribution-Driven PET Image-Based Outcome Prediction (DDD-PIOP): A Deep Learning Study for Oropharyngeal Cancer IMRT Application

Conference Frontiers in oncology · January 2020 Purpose To develop a deep learning-based AI agent, DDD-PIOP (Dose-Distribution-Driven PET Image Outcome Prediction), for predicting 18FDG-PET image outcomes of oropharyngeal cancer (OPC) in response to intensity-modulated radiation therapy (IMRT). Methods ... Cite

Liver 4D-MRI: An Image Mutual Information based Retrospective Self-sorting Method

Conference 2019 International Conference on Medical Imaging Physics and Engineering Icmipe 2019 · November 1, 2019 Four-dimensional MRI (4D-MRI) is an emerging technique for soft-tissue motion management in radiotherapy treatment planning. The purpose of this study was to develop a novel image mutual information (MI) based retrospective 4DMRI sorting method that is ful ... Full text Cite

Feasibility of radiosurgery dosimetry using NIPAM 3D dosimeters and x-ray CT

Conference Journal of Physics Conference Series · August 29, 2019 We investigated the feasibility of using N-isopropylacrylamide (NIPAM) dosimeters with x-ray CT to verify radiosurgery dose. Dosimeters were prepared at one facility and shipped to a second facility for irradiation. A simulation CT was acquired and plans p ... Full text Cite

Incorporating Case-Based Reasoning for Radiation Therapy Knowledge Modeling: A Pelvic Case Study

Conference Technology in Cancer Research and Treatment · January 1, 2019 Knowledge models in radiotherapy capture the relation between patient anatomy and dosimetry to provide treatment planning guidance. When treatment schemes evolve, existing models struggle to predict accurately. We propose a case-based reasoning framework d ... Full text Cite

Investigation of calibration-based projection domain dual energy decomposition CBCT technique for brain radiotherapy applications

Conference Progress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2019 The purpose of the present study was to develop and evaluate a practical dual-energy imaging approach for enhancing on-board cone-beam CT (CBCT) image quality for brain radiotherapy applications. The proposed primary technique involves a projection domain ... Full text Cite

High-resolution imaging immunolabeled large tissues

Conference Optics Infobase Conference Papers · January 1, 2017 We combined large sample resin embedding with immunofluorescence staining to acquire biomolecules profiles with high spatial-resolution. After evaluating the compatibility of this method and filtering embedding resin, we achieved to high-resolution image i ... Full text Cite

A simple, rapid method to precisely locate mRNAs of intact mouse brain via fluorescence tomography

Conference Optics Infobase Conference Papers · January 1, 2017 To precisely locate mRNAs of mouse brain, a simple, rapid method was developed via combining whole mount in situ hybridization and fluorescence tomography, with cytoarchitectonic landmarks provided by propidium iodide real-time counterstaining during the i ... Full text Cite

Physics considerations for single-isocenter, volumetric modulated arc radiosurgery for treatment of multiple intracranial targets.

Conference Pract Radiat Oncol · 2016 OBJECTIVE: Our purpose was to address challenges associated with single-isocenter radiosurgery for multiple intracranial targets (SIRMIT) including increased sensitivity to rotational uncertainties (resulting from distance of the targets from isocenter) as ... Full text Link to item Cite

WE-G-BRD-06: Volumetric Cine MRI (VC-MRI) Estimated Based On Prior Knowledge for On-Board Target Localization.

Conference Med Phys · June 2015 PURPOSE: To develop a technique to generate on-board VC-MRI using patient prior 4D-MRI, motion modeling and on-board 2D-cine MRI for real-time 3D target verification of liver and lung radiotherapy. METHODS: The end-expiration phase images of a 4D-MRI acqui ... Full text Link to item Cite

TH-CD-303-06: Deformable Registration-Based Image Estimation Method for 4D CBCT Using Region-Based PCA.

Conference Med Phys · June 2015 PURPOSE: To investigate the feasibility of using region-based principal component analysis (PCA) for motion modeling to estimate on-board 4D-CBCT using prior information and limited angle projections for potential 4D target verification of lung radiotherap ... Full text Link to item Cite

TH-AB-303-02: An Investigation of Respiratory Signal Parameters for Multiple-Step Ahead Prediction of Surrogate Motion.

Conference Med Phys · June 2015 PURPOSE: Target tracking or gating the radiation beam using real-time imaging and surrogate motion monitoring methods are employed for dynamic tracking treatment or respiratory-gated radiotherapy. This method requires tumor motion prediction far enough in ... Full text Link to item Cite

WE-D-303-05: Dosimetric Accuracy of CBCT Images Estimated by a Motion Modeling and Free-Form Deformation Technique for Radiotherapy of Lung Cancer.

Conference Med Phys · June 2015 PURPOSE: To investigate the dosimetric accuracy of CBCTs estimated by a motion modeling and free-form deformation(MM-FD) technique for radiotherapy of lung cancer. METHODS: Various inter-fractional variations featuring patient motion pattern change, tumor ... Full text Link to item Cite

WE-AB-303-09: Rapid Projection Computations for On-Board Digital Tomosynthesis in Radiation Therapy.

Conference Med Phys · June 2015 PURPOSE: To facilitate fast and accurate iterative volumetric image reconstruction from limited-angle on-board projections. METHODS: Intrafraction motion hinders the clinical applicability of modern radiotherapy techniques, such as lung stereotactic body r ... Full text Link to item Cite

SU-E-T-293: Dosimetric Analysis of Microscopic Disease in SBRT for Lung Cancers.

Conference Med Phys · June 2015 PURPOSE: To evaluate the dosimetry of microscopic disease (MD) region of lung cancer in stereotactic body radiation therapy (SBRT). METHODS: For simplicity, we assume organ moves along one dimension. The probability distribution function of tumor position ... Full text Link to item Cite

SU-E-J-26: A Novel Technique for Markerless Self-Sorted 4D-CBCT Using Patient Motion Modeling: A Feasibility Study.

Conference Med Phys · June 2015 PURPOSE: To develop an automatic markerless 4D-CBCT projection sorting technique by using a patient respiratory motion model extracted from the planning 4D-CT images. METHODS: Each phase of onboard 4D-CBCT is considered as a deformation of one phase of the ... Full text Link to item Cite

SU-E-I-40: Phantom Research On Monochromatic Images Taken by Dual CBCT with Multiple Energy Sets.

Conference Med Phys · June 2015 PURPOSE: To evaluate the quality of monochromatic images at the same virtual monochromatic energy using dual cone-beam computed tomography (CBCT) with either kV/kV or MV/kV or MV/MV energy sets. METHODS: CT images of Catphan 504 phantom were acquired using ... Full text Link to item Cite

MO‐G‐304‐03: Development of Knowledge Models for IMRT Treatment Planning Utilizing a Rapid Learning Approach

Conference Medical Physics · June 2015 Purpose:We present an implementation of the knowledge‐based planning method utilizing a rapid learning approach which enables the accurate evolution of models as new data are collected during daily clinical practi ... Full text Cite

Knowledge modeling for computer aided treatment planning

Conference Ifmbe Proceedings · January 1, 2015 The purpose for this study is to develop robust and comprehensive knowledge models which can provide patient specific prediction of achievable dose distribution in radiation therapy plans for a wide range of cancer types. These models are useful tools to g ... Full text Cite

Knowledge based automatic beam angle determination for lung IMRT planning

Conference Ifmbe Proceedings · January 1, 2015 We present an efficient knowledge based automatic beam configuration determination method by utilizing patient-specific anatomy and tumor geometry information and a beam bouquet atlas. The proposed technique is based on learning the relationship between pa ... Full text Cite

A rapid learning approach for the knowledge modeling of radiation therapy plan

Conference Ifmbe Proceedings · January 1, 2015 The purpose of this study is to implement a rapid learning method to train the knowledge models to predict the organ-at-risk (OAR) dose sparing in radiation therapy (RT) based on an array of patient anatomical features. We also aim to establish the evaluat ... Full text Cite

Automatic Determination of Beam Angles in Lung IMRT Planning

Conference International Journal of Radiation Oncology*Biology*Physics · September 2014 Full text Cite

Feasibility of Using a Fourier Markerless Technique for Clinical 4D-CBCT Reconstruction

Conference International Journal of Radiation Oncology*Biology*Physics · October 2013 Full text Cite

Incorporating Trade-Off in Knowledge Modeling of Parotid Dose Sparing in Head and Neck IMRT

Conference International Journal of Radiation Oncology*Biology*Physics · October 2013 Full text Cite

Quality Evaluation of an Automatic VMAT Planning Method for Head-and-Neck Cancer Cases

Conference International Journal of Radiation Oncology*Biology*Physics · October 2013 Full text Cite

Effects of PET Reconstruction Parameters on Region-of-Interest Contouring by SUV Threshold

Conference International Journal of Radiation Oncology*Biology*Physics · October 2013 Full text Cite

Modeling Organs at Risk Dose Sparing in Head and Neck Tomotherapy and IMRT Plans: A Comparison Study

Conference International Journal of Radiation Oncology*Biology*Physics · October 2013 Full text Cite

Normal Tissue Toxicity Criteria in Radiation Therapy

Conference International Journal of Radiation Oncology*Biology*Physics · October 2013 Full text Cite

Quantitative Comparison of Knowledge-Guided IMRT Planning to Expert Planning for Prostate Cancer

Conference International Journal of Radiation Oncology*Biology*Physics · October 2013 Full text Cite

Intertechnique and Interinstitutional Modeling of the Dosimetry of Organs-at-Risk in Head and Neck IMRT Plans

Conference International Journal of Radiation Oncology*Biology*Physics · October 2013 Full text Cite

SU-E-T-196: Pretreatment Patient Clinical Objective IMRT Quality Assurance Using a 3D Diode Array.

Conference Med Phys · June 2013 PURPOSE: To evaluate the accuracy and sensitivity of a patient clinical objective IMRT QA tool using a 3D diode array. METHODS: A 3D QA device (Delta4, Scandidos Inc.) with 2 orthogonal diode array planes was used for IMRT QA. The diode spacing is 5mm in c ... Full text Link to item Cite

WE-G-108-08: A Novel Technique for VMAT QA with EPID in Cine Mode On Varian TrueBeam.

Conference Med Phys · June 2013 PURPOSE: Volumetric modulated arc therapy (VMAT) is a relatively new treatment modality for dynamic photon radiation therapy. Pre-treatment quality assurance (QA) is necessary and many efforts have been taken to apply electronic portal imaging device (EPID ... Full text Link to item Cite

MO-F-WAB-11: Investigation of CBCT-Based Patient Positioning Accuracy in Lung SBRT: Correlation with Breathing Irregularity.

Conference Med Phys · June 2013 PURPOSE: To evaluate breathing irregularity induced error in CBCT-based patient positioning in lung SBRT and correlate the error with a measure of breathing variability. METHODS: The 4D extended cardiac-torso (XCAT) digital phantom was used to generate 10- ... Full text Link to item Cite

SU-E-T-560: A Method to Determine Optimal Dynamic MLC Parameters for Varian Truebeam with Millennium MLC and HDMLC.

Conference Med Phys · June 2013 PURPOSE: Correct MLC modeling is essential to the accurate IMRT delivery. Most TPSs use simplified models with parameters of leaf transmission (LT) and dynamic leaf gap (DLG). The common way to determine them is through extrapolation from measurements. In ... Full text Link to item Cite

WE-A-134-04: Comprehensive Evaluation of a Respiration-Phase-Matched Digital Tomosynthesis (DTS) Imaging Technique for Monitoring Moving Targets.

Conference Med Phys · June 2013 PURPOSE: To develop a respiration-phase-matched DTS technique to monitor moving targets, and to evaluate its accuracy for various imaging parameters and anatomical characteristics Methods: Conventional methods, registering on-board DTS(OB-DTS, reconstructe ... Full text Link to item Cite

TU-G-141-03: An On-Board 4D-CBCT Reconstruction Technique Using Limited-Angle Projections Based On Motion Modeling and Free-Form Deformation (MM-FD).

Conference Med Phys · June 2013 PURPOSE: To develop an on-board 4D-CBCT(OB-4D-CBCT) reconstruction technique using prior information and limited-angle projections for 4D inter/intra-fractional target verificationMethods: The OB-4D-CBCT at each phase is considered as a deformation of plan ... Full text Link to item Cite

SU-E-T-602: Dynamic Electron Arc Radiotherapy (DEAR): A Planning Study.

Conference Med Phys · June 2013 PURPOSE: Electron beam therapy is under-utilized in radiation treatment of cancer and has remained practically unchanged for decades. We propose a new technique, Dynamic Electron Arc Radiotherapy (DEAR) with synchronized couch motion. In DEAR, gantry rotat ... Full text Link to item Cite

TH‐A‐WAB‐04: Respiratory Sorted Imaging Using Region‐Of‐Interest Robotic Multi‐Pinhole SPECT System

Conference Medical Physics · January 1, 2013 Purpose: Single Photon Emission Computed Tomography (SPECT) may provide important information on tumors in the thorax and abdomen. Respiratory sorted imaging using conventional full cross‐section methods is generally degraded by noise. The purpose is to in ... Full text Cite

WE‐G‐500‐09: Robotic Multi‐Pinhole Scenarios for SPECT Molecular and Functional Imaging Onboard and in Other Applications

Conference Medical Physics · January 1, 2013 Purpose: Single Photon Emission Computed Tomography (SPECT) is one of the two predominant modes of nuclear emission tomography, the other being Positron Emission Tomography (PET). An important recent advance has been region‐of‐interest (ROI) SPECT for card ... Full text Cite

SU‐E‐J‐200: Impact of FDG‐PET/CT Reconstruction Parameters On PET Variability and Treatment Response Assessment

Conference Medical Physics · January 1, 2013 Purpose: To examine the effect of PET image reconstruction parameters on baseline and early‐treatment FDG‐PET/CT quantitative imaging. Early‐treatment changes in tumor metabolism in primary tumor and nodes can potentially determine if the patient is respon ... Full text Cite

SU‐E‐T‐474: Adaptive Stereotactic Body Radiation Therapy (SBRT) Planning for Lung Cancer: Can We Predict Who Will Benefit?

Conference Medical Physics · January 1, 2013 Purpose: We have previously shown that adaptive lung SBRT planning can mitigate dose to adjacent organs at risk (OARs). The aim of this study is to investigate factors that affect dosimetric effectiveness of adaptive lung SBRT, so that we may predict which ... Full text Cite

TU‐C‐141‐08: Evaluate Deformable Image Registration for the Lungs Using Hyperpolarized Gas Tagging MRI

Conference Medical Physics · January 1, 2013 Purpose: To evaluate deformable image registration for the lungs using hyperpolarized gas MR tagging technique.Method and Materials: A 3D MR grid‐tagging technique using hyperpolarized helium‐3 (HP‐He3) as gaseous contrast was developed for direct measurem ... Full text Cite

SU‐E‐J‐150: Investigation of Feasibility of Concurrent Orthogonal KV and MV X‐Ray Imaging for Tagrget Tracking During Dose Delivery for Stereotactic Body Radiotherapy (SBRT): A Pilot Phantom Study

Conference Medical Physics · January 1, 2013 Purpose: To investigate feasibility of motion tracking using concurrent orthogonal kV and MV x‐ray images acquired during dose delivery for stereotactic body radiotherapy (SBRT).Method and Materials: The study was performed on a Varian TrueBeam treatment u ... Full text Cite

SU‐E‐CAMPUS‐J‐04: Evaluating Radiation‐Induced Changes with Diffusion Weighted MRI and Dynamic Contrast Enhanced MRI in Patients with Early Stage Breast Cancer Treated with Stereotactic Body Radiotherapy: Initial Results

Conference Medical Physics · January 1, 2013 Purpose: Pre‐operative stereotactic body radiosurgery (SBRT) was delivered in a single fraction to treat patients with early stage breast cancer; however, few data are available regarding radiation‐induced changes by SBRT. In this work, diffusion weighted ... Full text Cite

SU‐E‐T‐707: Evaluation of the Quality of Organs‐At‐Risk Dose Sparing in Anorectal and Prostate IMRT Plans

Conference Medical Physics · January 1, 2013 Purpose: To evaluate the quality of organs‐at‐risk (OARs) dose sparing in IMRT plans for anorectal and prostate cancer cases utilizing organ‐based knowledge models to predict OAR DVHs.MethodsThe quality of OAR dose sparing in IMRT plans are evaluated by or ... Full text Cite

TH‐C‐137‐08: Dosimetric Quality of An Automatic IMRT Planning Method for Head and Neck Cancer Cases

Conference Medical Physics · January 1, 2013 Purpose: To evaluate the dosimetric quality of an automatic IMRT planning method for Head and Neck (HN) cancer cases. Methods: Eighteen HN cancer patients are planned with nine equally spaced IMRT beams. The OAR dose sparing objectives for each plan (prima ... Full text Cite

SU‐E‐CAMPUS‐T‐05: Quality Evaluation of An Automatic VMAT Planning Method for Head and Neck Cancer Cases

Conference Medical Physics · January 1, 2013 Purpose: To evaluate the dosimetric quality of an automatic volumetric‐modulated arc therapy (VMAT) planning method for Head and Neck (HN) cancer cases. Methods: Eighteen HN cancer cases are planned automatically by 2‐arc VMAT. An OAR DVH prediction model ... Full text Cite

TU‐E‐108‐02: Dynamic Electron Arc Radiotherapy (DEAR): A Feasibility Study

Conference Medical Physics · January 1, 2013 Purpose: Electron beam therapy is under‐utilized in radiation treatment of cancer and has remained practically unchanged for decades. We propose a new technique, Dynamic Electron Arc Radiotherapy (DEAR) with synchronized couch motion. DEAR utilizes modulat ... Full text Cite

SU‐E‐J‐91: Developing Platform for Online Registration Using Digital Tomosynthesis

Conference Medical Physics · January 1, 2013 Purpose: To meet the needs of fast registration of on‐board digital tomosynthesis (DTS), a platform was developed in assisting the task of intensive DTS reconstruction and analysis. Methods: this platform consists of four parts: pre‐processing, reconstruct ... Full text Cite

The effect of motion on IMRT - looking at interplay with 3D measurements.

Conference J Phys Conf Ser · 2013 Six base of skull IMRT treatment plans were delivered to 3D dosimeters within the RPC Head and Neck Phantom for QA verification. Isotropic 2mm 3D data was obtained using the DLOS-PRESAGE system and compared to an Eclipse (Varian) treatment plan. Normalized ... Full text Link to item Cite

Generation of Virtual Monochromatic (VM) CBCT from Dual kV/MV Beam Projections

Conference International Journal of Radiation Oncology*Biology*Physics · November 2012 Full text Cite

Dosimetric Evaluation of Flattening Filter-free (FFF) Photon Beams for Lung SBRT

Conference International Journal of Radiation Oncology*Biology*Physics · November 2012 Full text Cite

Impact of Patient Anatomy Variations on a Fourier Technique for Markerless 4D-CBCT

Conference International Journal of Radiation Oncology*Biology*Physics · November 2012 Full text Cite

Prostate SBRT in 5 Fractions: Initial Report on Dosimetric Results and IGRT Experiences

Conference International Journal of Radiation Oncology*Biology*Physics · November 2012 Full text Cite

Can Standard Radiation Therapy Quality Assurance (QA) Detect Potential Delivery Errors?

Conference International Journal of Radiation Oncology*Biology*Physics · November 2012 Full text Cite

Evaluation of IMRT and VMAT for Head-and-Neck Cancer With Flattening Filter-free (FFF) Beams

Conference International Journal of Radiation Oncology*Biology*Physics · November 2012 Full text Cite

Partial Breast Extracranial Radiosurgery: A Dosimetric Evaluation of Treatment Delivery Accuracy

Conference International Journal of Radiation Oncology*Biology*Physics · November 2012 Full text Cite

SU-E-T-406: Online Image-Guidance for Prostate SBRT: Dosimetric Benefits and Margin Analysis.

Conference Med Phys · June 2012 PURPOSE: To evaluate the dosimetric benefits of online image guidance during prostate stereotactic body radiotherapy (SBRT) and the potential on margin reduction. METHODS: 28 prostate SBRT patients were retrospectively studied, each treated with 37Gy in 5 ... Full text Link to item Cite

SU-E-T-626: Individualized Trade-Off of Dose Coverage and Sparing in IMRT Planning.

Conference Med Phys · June 2012 PURPOSE: We present an evidence-based approach to quantifying the dose sparing trade-offs between different Organs-at-risk (OARs) and the trade-off between OAR dose sparing and target dose coverage in IMRT plans. METHODS: The interaction between dose spari ... Full text Link to item Cite

MO-D-BRB-10: Modeling Inter-Patient Variation of Organ-At-Risk Sparing in IMRT Plans: An Evidence-Based Plan Quality Evaluation.

Conference Med Phys · June 2012 PURPOSE: To develop a predictive model to assess the quality of critical organ dose sparing in IMRT plans by providing patient specific dose sparing references, based on an array of patient anatomical features and prior planning experience. METHODS: Contri ... Full text Link to item Cite

TU‐A‐213CD‐04: A Novel Technique for Estimating and Correcting Cross‐Scatter in Dual‐Source CBCT

Conference Medical Physics · January 1, 2012 Purpose: Dual‐source CBCT may provide several advantages over current on‐board 3D localization techniques; however, dual‐source CBCT suffers greatly from cross‐scatter. A novel technique was developed that includes sampling the cross‐scatter only projectio ... Full text Cite

TH‐E‐BRA‐01: A Line‐Source Method for Aligning Onboard‐Robotic‐Pinhole and Other SPECT‐Pinhole Systems

Conference Medical Physics · January 1, 2012 Purpose: To achieve on‐board molecular imaging in the radiation therapy room, we are developing a robotic multi‐pinhole SPECT system. Alignment of the SPECT system to LINAC/CBCT coordinates is essential for target localization and image reconstruction. Pin ... Full text Cite

TU‐A‐BRA‐01: A Robotic Multi‐Pinhole SPECT System for Onboard and Other Region‐Of‐Interest Imaging

Conference Medical Physics · January 1, 2012 Purpose: Radiation therapy beam guidance and modulation at treatment time could be substantially supported by onboard molecular and functional imaging capability. Currently there is very little range of technology available for this. Herein we propose and ... Full text Cite

WE‐C‐213CD‐01: Decision Support for Radiation Therapy

Conference Medical Physics · January 1, 2012 Informatics in radiation therapy is less understood. Decision support for, or knowledge‐guided, radiation therapy, is a major component of informatics, where the data is mined, modeled and turned into computable knowledge. It is critically important for ra ... Full text Cite

TH‐C‐BRB‐01: Credentialing Results from a Spine Anthropomorphic Phantom

Conference Medical Physics · January 1, 2012 Purpose: To use an anthropomorphic spine phantom for dosimetric credentialing purposes in National Cancer Institute sponsored clinical trials. Methods: An anthropomorphic spine phantom that consists of lungs, a heart, an esophagus, a spinal cord, vertebrae ... Full text Cite

Dosimetric Evaluation and Optimization of a Novel CBCT Estimation Method for Adaptive Radiation Therapy (ART)

Conference International Journal of Radiation Oncology*Biology*Physics · October 2011 Full text Cite

WE‐E‐301‐01: Practical Tips for VMAT Implementation

Conference Medical Physics · January 1, 2011 Volumetric modulated arc therapy (VMAT) is an arc‐based dose delivery approach that produces highly conformal dose distributions similar to those generated with static gantry intensity modulated radiation therapy. Like many existing IMRT approaches, this t ... Full text Cite

SU‐E‐T‐98: VMAT Quality Assurance: Improving the Angular Correction Factors for Ion Chamber Arrays

Conference Medical Physics · January 1, 2011 Purpose: Two‐dimensional (2D) detector arrays for QA of volumetric‐modulated‐arc‐therapy (VMAT) plans show angular dependence. An angular correction‐factor‐table (CFs) minimize this effect, but assumes: (1) the response of all ion chambers (IC) is identica ... Full text Cite

SU‐E‐J‐22: Measurement‐Based Cross‐Scatter Correction in Dual Detector Cone‐Beam CT

Conference Medical Physics · January 1, 2011 Purpose: A dual detector cone‐beam CT (CBCT) system could potentially allow for dual energy CBCT and dual‐view DTS. However, image quality in this system is severely degraded by the presence of scatter between the two imaging chains, i.e. cross‐scatter. Th ... Full text Cite

SU‐C‐214‐06: Noise Power Properties of a Dual‐Detector Cone‐Beam CT System

Conference Medical Physics · January 1, 2011 Purpose: Very little information is available for noise properties using a dual‐detector cone‐beam CT (CBCT) system. Geometric misalignment, cross‐scatter, and inhomogeneous detector response are additional concerns in a dual‐detector system. This study ch ... Full text Cite

SU‐E‐J‐180: SPECT‐Based Target Localization: Comparison between Full‐Size and Compact Detectors

Conference Medical Physics · January 1, 2011 Purpose: Single photon emission computed tomography (SPECT) is being investigated for imaging inside radiation therapy (RT) treatment rooms to target tumor biology. Because of the space occupied by RT devices and the size and weight of typical gamma camera ... Full text Cite

TU‐E‐BRC‐08: Investigation of Anatomical Surrogate for 4DCT Imaging

Conference Medical Physics · January 1, 2011 Purpose: Respiratory signal for 4DCT is typically extracted using an external respiratory positioning management device (RPM) which is often inconvenient and time consuming. The efficiency of 4DCT imaging could be substantially improved if anatomical body ... Full text Cite

SU‐E‐I‐29: A Prior Information Based Total‐Variation Digital Tomosynthesis Reconstruction Algorithm

Conference Medical Physics · January 1, 2011 Purpose: To develop a total‐variation (TV) based compressive sensing image reconstruction algorithm using a set of limited‐angle projections by applying a prior image information to enhance the image quality and anatomic information of current Four‐d ... Full text Cite

MO‐D‐214‐01: 4D‐MRI for Radiation Therapy of Moving Tumors

Conference Medical Physics · January 1, 2011 Four‐dimensional computed tomography (4D‐CT) has been widely used in radiation therapy for imaging moving tumors, especially in the thoracic regions. In other body sites such as the abdominal, 4D‐CT is limited due to its intrinsic low soft‐tissue contrast. ... Full text Cite

MO‐D‐BRB‐03: Investigation of the Reproducibility of Probability Distribution function (PDF) of Tumor Motion in Lung Stereotactic Body Radiation Therapy (SBRT)

Conference Medical Physics · January 1, 2011 Purpose: To investigate the reproducibility of probability distribution function (PDF) of lung tumor motion using cine‐MV images from lung SBRT treatments. Findings of the study will provide valuable information for probability‐based treatment planning. Me ... Full text Cite

SU‐E‐T‐123: Evaluation of Integrated Gating Systems on a Novalis Tx System Using Quantitative Motion Tracking Analyses and Efficient Time‐Delay Measurements

Conference Medical Physics · January 1, 2011 Purpose: To investigate accuracy of motion tracking and radiation delivery controlling of integrated gating systems on a Novalis Tx system. Methods: The study was performed on a Novalis Tx system, which is equipped with Varian RPM and BrainLAB ExacTrac gat ... Full text Cite

SU‐F‐BRA‐10: A Novel Technique for Markerless Self‐Sorted 4D‐CBCT

Conference Medical Physics · January 1, 2011 Purpose: Four‐dimensional (4D) imaging in the radiotherapy treatment room can provide verification of moving targets, which allows for potential reduction of margins and consequent dose escalation. 4D‐CBCT acquisition requires correlation between projectio ... Full text Cite

MO‐F‐211‐04: Fast Phase Contrast MR Angiography with Simplified Skipped Phase Encoding and Edge Deghosting with Array Coil Enhancement (S‐ SPEED‐ACE)

Conference Medical Physics · January 1, 2011 Purpose: The aim of this work is to investigate the feasibility of accelerating phase contrast MR angiography by the fast imaging method of Simplified Skipped Phase Encoding and Edge Deghosting with Array Coil Enhancement (S‐SPEED‐ACE). Methods: The parall ... Full text Cite

SU‐E‐T‐99: A Patient Specific QA Protocol for Verification of 4D Dosimetry

Conference Medical Physics · January 1, 2011 Purpose: Presently, there is no patient specific dosimetric QA for radiation treatment of moving targets. Here we present a patient specific QA protocol for verification of 4D dosimetry delivered to a moving target in SBRT of lung and liver tumors. Methods ... Full text Cite

MO‐D‐BRC‐01: Dosimetric Evaluation of a Novel Cone‐Beam CT (CBCT) Estimation Method Using Prior Information for Lung Cancer Patient Treatment

Conference Medical Physics · January 1, 2011 Purpose: To evaluate the dosimetric accuracy of a novel CBCT estimation method using prior information for use in adaptive radiotherapy (ART)‐based treatment of lung cancer patients. Methods: Patient planning CT or previous day's CBCT images are used as th ... Full text Cite

SU‐C‐110‐01: Strategies for Online Plan Re‐Optimization: Objective Settings and Starting Stage

Conference Medical Physics · January 1, 2011 Purpose: To find the most robust strategies of objective setting and starting stage for online plan re‐optimization, so it can be automatically executed within 1 min while providing high quality adaptive plans. Methods: 10 prostate cancer patients, each wi ... Full text Cite

SU‐E‐T‐860: Developing a Fast‐Monotonic Descent (FMD) Algorithm for RapidArc Radiotherapy

Conference Medical Physics · January 1, 2011 Purpose: To develop a fast‐monotonic descent (FMD) algorithm for optimization of VMAT treatment planning, and investigate the impacts of arc numbers and beam interval on the plan dose quality. Methods: Fast‐monotonic descent (FMD) algorithm, proved to be o ... Full text Cite

SU‐E‐T‐854: Key Anatomical Factors Influencing OAR Dose‐Volume Distribution in Prostate IMRT Plans

Conference Medical Physics · January 1, 2011 Purpose: To identify the key factors of patient anatomy that influence the optimal dose volume histograms (DVHs) for the organs‐at‐risk (OARs) and to explore the tradeoffs between different OAR sparing goals. Methods: 88 prostate IMRT plans were studied re ... Full text Cite

TH‐E‐BRB‐05: Modeling the Correlation Between OAR Dose Sparing and Patient's Anatomy in Head and Neck IMRT

Conference Medical Physics · January 1, 2011 Purpose: To summarize the knowledge of the dependence of organ‐at‐risk (OAR) dose‐volume distribution on patient's anatomy by machine learning techniques from a database of previous expert plans. Methods: 35 head‐and‐ neck IMRT plans were studied retrospec ... Full text Cite

Phase Window and Frame Rate Optimization for On-board 4D Imaging Dose Reduction

Conference International Journal of Radiation Oncology*Biology*Physics · November 2010 Full text Cite

Reduced Cross Scatter in Dual-source Cone-Beam CT by Asynchronous Projection Acquisition

Conference International Journal of Radiation Oncology*Biology*Physics · November 2010 Full text Cite

Potentially Underestimating the Internal Target Volume (ITV) in Free-Breathing Cone-Beam CT (CBCT)

Conference International Journal of Radiation Oncology*Biology*Physics · November 2010 Full text Cite

On-board SPECT for Target Localization: A Comprehensive Analysis of Findings from Computer Simulation and Scanner Studies

Conference International Journal of Radiation Oncology*Biology*Physics · November 2010 Full text Cite

Extracting Breathing Signal from Image Fourier Transform for Developing 4D-MRI

Conference International Journal of Radiation Oncology*Biology*Physics · November 2010 Full text Cite

Stereotactic Body Radiotherapy (SBRT) in Patients Previously Treated with External Beam Radiation Therapy

Conference International Journal of Radiation Oncology*Biology*Physics · November 2010 Full text Cite

A Modern Animal Model of Radiation-induced Erectile Dysfunction

Conference International Journal of Radiation Oncology*Biology*Physics · November 2010 Full text Cite

Intensity Modulated Arc Therapy: Effective and Efficient End-to-end Patient Specific Quality Assurance

Conference International Journal of Radiation Oncology*Biology*Physics · November 2010 Full text Cite

Variation of Clinically Relevant Dose Indices for 3DCRT of Lung with Respect to Dose Calculation Algorithm

Conference International Journal of Radiation Oncology*Biology*Physics · November 2010 Full text Cite

SU‐GG‐I‐140: Maximum Intensity Projection (MIP) Imaging Using Multi‐Slice Cine MRI

Conference Medical Physics · January 1, 2010 Purpose: To propose a novel method of acquiring Maximum Intensity Projection (MIP) images using multi‐slice cine MRI, termed as MRI‐MIP, and to evaluate its feasibility in quantifying motion magnitude. Materials and Methods: MRI‐MIP images are acquired usi ... Full text Cite

SU‐GG‐T‐483: Does Breath‐Hold Immobilization Affect Tumor Radioresistance in Breast?

Conference Medical Physics · January 1, 2010 Purpose: A 15–30s Breath Hold (BH) is often used in radiation therapy for breast cancer patients to minimize heart dose, however its effect on tumor oxygenation and radiosensitivity is unknown. The purpose of this study is to utilize published data on the ... Full text Cite

TU‐A‐204B‐04: A Technique to Correct Crescent Artifacts in On‐Board CBCT

Conference Medical Physics · January 1, 2010 Purpose: Large dark and bright crescents are commonly seen in cone‐beam (CB) CT images acquired onboard radiation therapy machines. The purpose of this project is to develop a technique for removing this artifact. Method and Materials: We propose that cres ... Full text Cite

TU‐C‐204B‐06: Performance Evaluation of a Dual Cone‐Beam CT (Dual CBCT) System

Conference Medical Physics · January 1, 2010 Purpose: Very little information is available for clinical CBCT imaging using a dual‐detector system. This study assesses the performance of a recently developed bench‐top dual large‐flat‐panel detectors cone beam computed tomography (CBCT) system and to c ... Full text Cite

SU‐GG‐J‐80: Characterization of Cross Scatter in Dual Source CBCT

Conference Medical Physics · January 1, 2010 Purpose: A dual‐source CBCT imaging system provides an efficient means to perform 3D and 4D imaging, but the addition of the second imaging chain produces additional scattered photons or cross scatter. The purpose of this study is to characterize cross sca ... Full text Cite

SU‐GG‐T‐136: Treatment Plans Comparison with Static‐Gantry IMRT and RapidArcTM for Head‐And‐Neck Cancers Involving Cervical Lymph Nodes

Conference Medical Physics · January 1, 2010 Purpose: To compare the dosimetric results and treatment efficiency of intensity modulated arc therapy using RapidArc™ to static‐gantry IMRT plans for conventional fractionation treatment of head‐and‐neck cancer. Materials and Methods: This study evaluated ... Full text Cite

SU‐GG‐T‐530: Comparison of Coplanar and Non‐Coplanar Intensity Modulated Arc Techniques for Treatment of Intracranial Multi‐Focal Stereotactic Radiosurgery

Conference Medical Physics · January 1, 2010 Objectives: Intensity modulated arc therapy (IMAT) can potentially be a useful technique for the treatment of multi‐focal intracranial stereotactic radiosurgery (SRS) with a single isocenter setup. This study compares the effects of coplanar and non‐coplan ... Full text Cite

SU‐GG‐J‐67: Evaluating Dynamic Magnetic Resonance Imaging Using a New Design of Phantom: Validation with Fast Megavoltage Fluoroscopic Imaging

Conference Medical Physics · January 1, 2010 Purpose: To devlope a reliable and economic phantom for motion management study and investigate its feasibility in evaluating dynamic MRI. Method and Materials: Experiments was performed using an in‐house developed phantom that consists of a platform, a lo ... Full text Cite

TU‐B‐201B‐02: Self‐Sorted Four‐Dimensional CT Using Body Volume as Respiratory Surrogate

Conference Medical Physics · January 1, 2010 Purpose: To develop a self‐sorting four‐dimensional CT (4D‐CT) technique that uses body volume as the respiratory surrogate. Method and Materials: Respiratory signals are determined by the changes in body volume at each slice location as a function of imag ... Full text Cite

SU‐GG‐I‐148: Self‐Sorted Four‐Dimensional Magnetic Resonance Imaging: A Feasibility Study

Conference Medical Physics · January 1, 2010 Purpose: Considerable imaging dose to health tissue of patient from 4D‐CT is often a concern. This study is to develop a four‐dimensional magnetic resonance imaging (4D‐MRI) technique based on retrospective sorting strategy that uses body volume as respira ... Full text Cite

SU‐GG‐I‐24: Improving IGRT Efficiency Using GPU‐Based Ultrafast Reconstruction of DTS/CBCT and DRR

Conference Medical Physics · January 1, 2010 Purpose: One challenge of on‐line image‐guided radiation therapy is requirement of immediate availability of reconstructed 3D or 4D images for evaluation. This study is to develop a highly data‐parallel version and platform of accelerating reconstruction f ... Full text Cite

SU‐GG‐J‐62: Use Winston‐Lutz Test to Check Cone Beam CT Isocenter Accuracy for Imaging Guided Intracranial Stereotactic Radiosurgery

Conference Medical Physics · January 1, 2010 Objectives: Cone beam CT (CBCT) opens the era of three dimensional (3D) imaging guided stereotactic radiosurgery (SRS). The CBCT isocenter accuracy is critical for imaging guided SRS guidance. This study analyzes the daily quality assurance (QA) results of ... Full text Cite

SU‐GG‐I‐144: Accelerating Non‐Contrast‐Enhanced MRA with Inflow Inversion Recovery by Using Skipped Phase Encoding and Edge Deghosting (SPEED)

Conference Medical Physics · January 1, 2010 Purpose: Non‐contrast‐enhanced MR angigraphy (MRA) has always been a valuable clinical tool to study vasculatural diseases. The recently arising concerns of constrast agents in contrast‐enhanced MRA encouraged more use of non‐contrast‐enhanced MRA. The aim ... Full text Cite

SU‐GG‐T‐225: Gantry‐Angle Dependence of a 2D Ion Chamber Array for IMAT QA

Conference Medical Physics · January 1, 2010 Purpose: Gantry‐angle dependence of dose measurement for intensity‐modulated arc therapy (IMAT) quality assurance (QA) using a two‐dimensional ion chamber array may be significant. A new device, the gantry angle sensor, has been provided to compensate for ... Full text Cite

SU‐GG‐T‐137: Similarities between Static and Rotational Intensity Modulated Plans

Conference Medical Physics · January 1, 2010 Purpose: To explore similarities between intensity modulated radiotherapy (IMRT) and intensity modulated arc therapy (IMAT) techniques in the context of the number of multi‐leaf collimator (MLC) segments required to achieve plan objectives, the major facto ... Full text Cite

SU‐GG‐T‐583: Dosimetric Comparison of Anisotropic Analytical and Pencil Beam Convolution Algorithms in Breast Cancer Radiation Treatment Planning

Conference Medical Physics · January 1, 2010 Purpose: The anisotropic analytical algorithm (AAA) has been shown to provide more accurate dose calculation due to 3D scatter and inhomogeneity corrections than the pencil beam convolution algorithm (PBC) for inhomogeneous anatomical regions such as lung ... Full text Cite

TH‐C‐204B‐07: Development of Image‐Guided Radiosurgery with Novalis TX for Small Animal Study

Conference Medical Physics · January 1, 2010 Purpose: Developing a protocol to accomplish small animal radiosurgery study conducted at our clinic in evaluating radiation‐induced erectile dysfunction. Method and Materials: Animals were sedated and scanned using commercial CT scanner. Scans were import ... Full text Cite

SU‐GG‐T‐362: Is Distance‐Dependent Energy Correction Needed for Dosimetric Measurements Surrounding Brachytherapy Sources?

Conference Medical Physics · January 1, 2010 Purpose: The answer depends on both the dosimeter's energy response and energy spectrum at distance (point of measurement) from the source. The latter is object of this study. Method and Materials: The spectra in water were calculated with Monte Carlo code ... Full text Cite

SU‐GG‐I‐14: A Method to Estimate Cone‐Beam CT Dose Index and Cone‐Beam Dose Length Product

Conference Medical Physics · January 1, 2010 Purpose: To characterize the cone‐beam CTDI (CBCTDI) and cone‐beam dose length product (CBDLP) by Monte Carlo (MC) technique. Method and Materials: An extended CT head phantom (60cm long) and an extended CT body phantom (90cm long) were created in our BEAM ... Full text Cite

SU‐GG‐I‐57: Dose and Image Quality Evaluation for Partial and Full‐Angle Kilovoltage Cone‐Beam CT Protocols

Conference Medical Physics · January 1, 2010 Purpose: To assess imaging dose of partial and full‐angle CBCT scan protocols, and to evaluate their image quality. Method and Materials: The CTDI of the six new CBCT protocols for Varian OBI were obtained by ion chamber (IC) measurements and Monte Carlo ( ... Full text Cite

SU‐EE‐A1‐03: Arc Modulated Radiation Therapy Based on Linear Models

Conference Medical Physics · January 1, 2010 Purpose: The challenge for implementing promising Arc Modulated Radiation Therapy (AMRT) is its effectiveness of treatment planning tools to find optimal multileaf collimator (MLC) sequence and the fluence map. This study provides a new approach to the abo ... Full text Cite

WE‐B‐BRA‐03: Adaptive Image‐Guided Radiation Therapy (AIGRT) for Hypo‐Fractionated Prostate Cancer Treatment

Conference Medical Physics · January 1, 2010 Purpose: The large fractional dose of hypo‐fractionated prostate treatment requires high accuracy of daily treatment delivery. This study analyzes the performance of an adaptive IGRT (AIGRT) technique, which combines image guidance and adaptive re‐planning ... Full text Cite

TU‐E‐BRB‐03: A Planning Quality Evaluation Tool for Adaptive IMRT Treatment Based on Machine Learning

Conference Medical Physics · January 1, 2010 Purpose: To monitor the quality of adaptive IMRT plans, especially dose sparing for the organs‐at‐risk (OARs), a plan evaluation tool is developed to predict the dose volume histogram (DVH) based on patient's anatomical information and a database of high q ... Full text Cite

SU‐GG‐J‐76: Validation of a Proposed Optimal Slow Gantry Rotation Technique for On‐Board Four‐Dimensional Imaging Using Lung Patient Data

Conference Medical Physics · January 1, 2010 Purpose: Substantial efforts have been made in recent years to develop on‐board four‐dimensional (4D) imaging techniques using gantry mounted cone‐beam imaging devices. This study validates a slow gantry rotation 4D imaging protocol using lung patient data ... Full text Cite

TH‐A‐BRA‐03: TG‐104: In‐Room kV Imaging for IGRT

Conference Medical Physics · January 1, 2010 In‐room kilovoltage (kV) x‐ray imaging refers to radiographic imaging using kV x‐ray sources in the radiation treatment room. It has been widely accepted for radiotherapy target localization and treatment intervention. Task Group 104 (TG 104) reports on th ... Full text Cite

SU‐DD‐A3‐03: How Accurately Can the Internal Target Volume (ITV) from a Free‐Breathing Cone Beam Computed Tomography (FB‐CBCT) Scan Be Used for Target Verification?

Conference Medical Physics · January 1, 2010 Purpose: An internal target volume (ITV) is often identified by acquiring a free‐breathing cone‐beam computed tomography scan (FB‐CBCT) to verify patient setup of tumors affected by respiratory motion. However, its accuracy is not well understood. The purp ... Full text Cite

Evaluating the Commissioning and QA of Intensity Modulated Arc Therapy using a Benchmark IMRT Planning Suite

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

Slow Gantry Rotation 4D Digital Tomosynthesis for Lung Motion Imaging

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

On-board SPECT Imaging: Improved Target Localization via Spatial Resolution Compensation

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

Six-dimensional Image Guidance for Spinal Noninvasive SRS/SBRT: Comparison between ExacTrac X-ray 6D with kV Cone-beam CT

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

Imaging Guided Stereotactic Radiosurgery and its Accuracy Compared to Frame-based Localization

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

Can Biological Optimization Be Incorporated into the Current Clinical Treatment Planning Workflow?

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

Hybrid IGRT Technique for Prostate Hypofractionation

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

Treatment Plan Comparison between IMRT and Volumetric IMAT using One- and Two-arc Beams for Prostate Cancer

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

Apparatus-dependent Differences in Spine Stereotactic Body Radiosurgery (SBRT) Dosimetry

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

Quantitative Study of Geometrical Distortion in Cone-beam CT Images Reconstructed using FDK Algorithm

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

Comparing Static vs. Rotational IMRT for Spine Body Radiotherapy

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

Evaluation of In-Room Cone-Beam CT Imaging Techniques Compared to CT for Dose Calculation

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

SU‐FF‐T‐498: Improving Normal Tissue Complication Probability Fits Using Non‐Binary Outcomes

Conference Medical Physics · January 1, 2009 Purpose: Binary outcomes (toxicity=1, no‐toxicity=0) are frequently used as inputs to fit parametric models. However, in reality, outcomes span the range in‐between these extremes; binary values are used for lack of more precise quantification. We propose ... Full text Cite

TH‐B‐BRC‐01: Tools for IMRT Commissioning: Static and Rotating Gantries

Conference Medical Physics · January 1, 2009 Commissioning an IMRT system refers to the initial verification by phantom studies that treatments can be planned, prepared, and delivered with sufficient accuracy. Our profession has struggled since the inception of IMRT to define what measurements to mak ... Full text Cite

SU‐FF‐T‐309: Quality Assurance for Imaging Guided Stereotactic RadioSurgery with Novalis Tx™ System

Conference Medical Physics · January 1, 2009 Purpose: To present QA measurements over extended periods at our institute and recommend a QA program for image‐guided radiosurgery on Novalis Tx system. Method and Materials: Novalis Tx system is developed based on a Trilogy linear accelerator featuring B ... Full text Cite

SU‐FF‐T‐322: Geometric Calibration of a Dual Cone Beam CT System with Large Flat Panel Detectors

Conference Medical Physics · January 1, 2009 Purpose: To assess errors in a simple visual alignment of a dual large‐flat‐panel, cone‐beam‐CT (CBCT) system, and to obtain misalignment parameters that can be incorporated into image reconstruction for accurate target localization in image‐guided radiati ... Full text Cite

SU‐FF‐J‐09: Limited‐Angle Imaging for Target Positioning Using Orthogonal Conebeam X‐Ray Systems

Conference Medical Physics · January 1, 2009 Purpose: To investigate limited‐angle imaging using orthogonal x‐ray systems, with regard to use for target positioning onboard external beam radiation therapy (EBRT) machines. Method and Materials: Image reconstruction was performed using projection data ... Full text Cite

SU‐FF‐J‐02: Impact of Cross Scatter On CNR in Fluoroscopic Images Taken with a Dual Flat Panel X‐Ray Imaging System

Conference Medical Physics · January 1, 2009 Purpose: To examine the impact of cross scatter on contrast‐to‐noise ratio (CNR) in fluoroscopic images acquired with a dual flat‐panel x‐ray imaging system. Method and Materials: An x‐ray imaging system has been developed consisting of two tube/detector p ... Full text Cite

SU‐FF‐T‐130: Radiotherapy Treatment Plans with RapidArc for Head‐And‐Neck Cancer

Conference Medical Physics · January 1, 2009 Purpose: The purpose of this study is to compare RapidArc plans and conventional IMRT plans for head‐and‐neck cancer treatment involving bilateral nodes. Methods and Materials: This study included 10 locally advanced head‐and‐neck cancer patients. The plan ... Full text Cite

SU‐EE‐A3‐02: Imaging Guided Frameless Stereotactic RadioSurgery Using CBCT 6D Image Registration and 6D Couch On Novalis Tx™ System

Conference Medical Physics · January 1, 2009 Purpose: To investigate localization accuracy for image‐guided frameless stereotactic‐radiosurgery (IG‐SRS) using CBCT 6D image registration and 6D‐couch on Novalis Tx system. Method and Materials: Novalis Tx system is a powerful radiosurgery system featur ... Full text Cite

SU‐FF‐T‐545: Feasibility Study for Treatment of Intracranial Multi‐Focal Stereotactic Radiosurgery with Multiple Intensity Modulated Arc Technique

Conference Medical Physics · January 1, 2009 Objectives: To investigate the feasibility of using an intensity modulated arc technique for multi‐focal intracranial stereotactic radiosurgery with a single isocenter setup to significantly decrease the treatment time. Methods: A Novalis Tx linear acceler ... Full text Cite

SU‐FF‐T‐548: Comparison of Cone‐Beam CT and Frame‐Based Localizations for Stereotactic Radiosurgery with Fixed Head Rings and Removable Frames

Conference Medical Physics · January 1, 2009 Objectives: To compare localization accuracy using both conventional frame‐based localizers and cone‐beam CT (CBCT) images for stereotactic radiosurgery (SRS). Methods: A SRS geometric phantom was used to verify the localization accuracy based on a SRS loc ... Full text Cite

SU‐FF‐T‐301: Clinical Implementation and Commission of Volumetric Modulated Arc Therapy

Conference Medical Physics · January 1, 2009 Purpose Volumetric modulated arc therapy (VMAT) is a rotational IMRT modality that combines dose rate modulation with gantry and MLC motion, thereby increasing the complexity of IMRT delivery. Effective implementation of this technology is still quite new ... Full text Cite

SU‐FF‐T‐314: Patient‐Specific Quality Assurance Techniques for RapidArc Radiotherapy

Conference Medical Physics · January 1, 2009 Purpose: To develop a patient‐specific quality assurance protocol for RapidArc™ radiotherapy. Method and Materials: Following the commissioning of RapidArc™ treatment delivery, we tested several methods of patient‐specific quality assurance (QA). Ion chamb ... Full text Cite

SU‐FF‐J‐56: Integrating Real‐Time Tracking Into Image Guided Radiation Therapy for Prostate Cancer Treatment

Conference Medical Physics · January 1, 2009 Purpose: To investigate how a real‐time tracking technique, based on implanted transponders, could be effectively integrated into the current process for image‐guided radiation treatment of prostate cancer. Method and Materials: Current prostate IGRT proce ... Full text Cite

SU‐FF‐T‐158: A Method to Overlay Biological Optimization On Traditional Dose‐Volume Constrained Intensity Modulated Radiotherapy (IMRT) Optimization

Conference Medical Physics · January 1, 2009 Purpose: Biological optimization for IMRT planning is typically not clinically utilized, perhaps due to uncertainties associated with normal tissue complication models. Clinically, IMRT planning still relies heavily on dose‐volume constraints. We propose a ... Full text Cite

SU‐FF‐I‐56: Radiation Dose Estimation From Pediatric Cone Beam Computed Tomography

Conference Medical Physics · January 1, 2009 Purpose: To estimate absorbed doses and effective dose (ED) from cone beam computed tomography (CBCT) with metal oxide semiconductor field effect transistor (MOSFET) detectors in an anthropomorphic phantom, and to estimate the risk of cancer incidence from ... Full text Cite

TH‐A‐211A‐01: Digital Tomosynthesis for Target Localization

Conference Medical Physics · January 1, 2009 Any deviation between treated and planned volumes for 3‐D conformal therapy, such as IMRT, may cause an adverse clinical outcome. It is therefore critical to minimize all potential deviations using an on‐board (or real‐time) imaging procedure immediately p ... Full text Cite

SU‐FF‐T‐673: Application of RapidArc Technique to Cervical Spine Stereotactic Treatment

Conference Medical Physics · January 1, 2009 Purpose: Cervical spine (C‐spine) lesions are located more centrally than the rest of the spinal column making the c‐spine an ideal target for the RapidArc therapy technique. In this study, we explore the use of RapidArc to treat c‐spine patients and inves ... Full text Cite

SU‐FF‐T‐567: Volumetric Modulated Arc Therapy for Spine Body Radiotherapy: Comparison with Static Intensity Modulated Treatment

Conference Medical Physics · January 1, 2009 Purpose: Volumetric modulated arc treatment (VMAT) reduces treatment time over static beam intensity modulated treatment (IMRT) by delivering IMRT using arcs. This clinical study evaluates the feasibility of using VMAT for spine stereotactic body radiother ... Full text Cite

SU‐FF‐J‐55: Acceptance Testing and Quality‐Assurance Protocols for the Calypso® 4D Localization System™ and Q‐Fix®/Calypso® Couchtop

Conference Medical Physics · January 1, 2009 Purpose: To develop quality‐assurance (QA) protocols for the Calypso® 4D Localization System including acceptance testing, commissioning, daily QA, monthly QA, and annual QA. Method and Materials: The following acceptance testing/commissioning/QA protocols ... Full text Cite

SU‐FF‐T‐80: Hybrid Image Guided Radiation Therapy for Hypofractionated Prostate IMRT: Feasibility Study

Conference Medical Physics · January 1, 2009 Purpose: In prostate IGRT employing hypofractionation, two methods are commonly used: patient re‐positioning and re‐planning. We propose a hybrid IGRT technique in this study. The dosimetric benefits and efficiency improvement of the technique is quantitat ... Full text Cite

SU‐FF‐T‐574: Radiotherapy Treatment Plans with RapidArc for Prostate Cancer Involving Seminal Vesicles

Conference Medical Physics · January 1, 2009 Purpose: The purpose of this report is to compare RapidArc plans and conventional IMRT plans for prostate cancer involving seminal vesicles. Methods and Materials: This study included 10 patients. The planning‐target volume (PTV) contained the prostate and ... Full text Cite

SU‐FF‐T‐223: A New IMRT/RapidArc QA Procedure Utilizing MLC Dynalog Files

Conference Medical Physics · January 1, 2009 Purpose: To develop a quick and efficient patient‐specific QA procedure for both IMRT and RapidArc using MLC dynalog files. Method and Materials: MLC dynalog files record both planned and actual MLC leaf positions, actual fractional MU and gantry angle. Th ... Full text Cite

SU‐FF‐J‐12: HU and Dosimetric Comparison of Six Cone‐Beam CT Acquisition Techniques for Radiation Therapy Planning

Conference Medical Physics · January 1, 2009 Purpose: It has been shown that cone‐beam computed tomography (CBCT) can be used in dose calculation for treatment planning. This study investigates the HU and dosimetric properties of six CBCT techniques in comparison with conventional CT to determine whi ... Full text Cite

TU‐C‐303A‐04: Slow Gantry Rotation Acquisition Protocol for Four‐Dimensional Digital Tomosynthesis

Conference Medical Physics · January 1, 2009 Purpose: Four‐dimensional digital tomosynthesis (4D‐DTS) was recently introduced as a novel on‐board 4D imaging technique. The purpose of this study is to develop and implement a slow gantry rotation acquisition protocol for 4D‐DTS. A formalism for determi ... Full text Cite

High-definition Micro-multileaf Collimator in Radiosurgery Treatment Planning for Arteriovenous Malformations

Conference International Journal of Radiation Oncology*Biology*Physics · September 2008 Full text Cite

Dosimetrical Evaluation of SRS/SBRT Techniques

Conference International Journal of Radiation Oncology*Biology*Physics · September 2008 Full text Cite

Can Cone Beam CT Replace Frame-based Localization for Stereotactic Radiosurgery?

Conference International Journal of Radiation Oncology*Biology*Physics · September 2008 Full text Cite

A Novel Digital Tomosynthesis (DTS) Reconstruction Method using Prior Information and a Deformation Model

Conference International Journal of Radiation Oncology*Biology*Physics · September 2008 Full text Cite

Dosimetrical Evaluation of an Online Adaptive IMRT Technique

Conference International Journal of Radiation Oncology*Biology*Physics · September 2008 Full text Cite

SU‐GG‐T‐406: Improving Lung Radiation‐Pneumonitis Prediction by Combining Different Models

Conference Medical Physics · January 1, 2008 Purpose: Combining the results of methodologically different models (decision fusion) has been shown to yield a fused result that more truthfully represents the underlying phenomenon, compared to the individual models. In this work, we study the effect of ... Full text Cite

WE‐C‐AUD B‐05: Predicting Radiation‐Induced Cardiac Perfusion Defects Using a Fusion Model

Conference Medical Physics · January 1, 2008 Purpose: To predict radiation‐induced cardiac perfusion defects using a fusion model that combines the results of four separate models: feed‐forward neural networks (NNET), self‐organizing maps (SOM), support vector machines (SVM), and multivariate adaptiv ... Full text Cite

SU‐GG‐J‐156: Quantitative Analysis of Onboard SPECT Imaging Using Compact Gamma Cameras

Conference Medical Physics · January 1, 2008 Purpose: Single photon emission computed tomography (SPECT) imaging on‐board radiation therapy machines may enhance radiation therapy. Use of a light‐weight, compact detector would be desirable because of maneuverability, yet is challenged by truncation an ... Full text Cite

SU‐GG‐T‐38: Tracking of Brachytherapy Source Position Using Emission Imaging

Conference Medical Physics · January 1, 2008 Purpose: To construct an imaging system that uses the exit radiation from a brachytherapy source during treatment. This system uses a single flat panel detector (FPD) and is capable of tracking the source position in 3D space, with no extra imaging radiati ... Full text Cite

SU‐GG‐T‐446: Dosimetric Characteristics of High Definition Multi‐Leaf Collimator

Conference Medical Physics · January 1, 2008 Purpose: A new type of high‐definition multi‐leaf collimator (HD 120 MLC, Varian Medical Systems) is being introduced into clinical practice to improve the conformality of stereotactic radiation therapy and radiosurgery. Its leaf width at isocenter is 2.5 ... Full text Cite

SU‐GG‐T‐454: Localization Accuracy of Cone‐Beam CT Guided Radiosurgery as Investigated Utilizing a Geometric Phantom

Conference Medical Physics · January 1, 2008 Purpose: While the advantage of imaging guidance with cone beam CT (CBCT) guided radiosurgery is obvious, the localization accuracy of CBCT guided radiosurgery still remains a concern. This study utilized a geometric phantom with known target positions to ... Full text Cite

SU‐GG‐J‐177: The Application of An ASi‐Based EPID to Guide Intensity Modulated Radiation Therapy (IMRT) of Head‐And‐Neck Cancer

Conference Medical Physics · January 1, 2008 Purpose: In head‐and‐neck IMRT treatment, doses to targets and critical organs are affected by many factors including patient positioning, weight loss and tumor shrinkage. To ensure therapeutic effectiveness, re‐planning with a new CT is often conducted. H ... Full text Cite

SU‐EE‐A4‐04: Accelerating Breast Dynamic Contrast Enhanced MRI with Efficient Multiple Acquisitions by SPEED Using Shared Information

Conference Medical Physics · January 1, 2008 Purpose: The efficient multiple acquisition method using Skipped Phase Encoding and Edge Deghosting (SPEED) has been successfully demonstrated with a dynamic contrast enhanced (CE) mice tumor study; however, it has not been tested with any human subjects. ... Full text Cite

MO‐D‐351‐07: A System to Dynamically Balance Dose Sparing Between Critical Structures in Intensity Modulated Radiation Therapy (IMRT)

Conference Medical Physics · January 1, 2008 Purpose: The IMRT treatment planning optimization process typically follows one, somewhat arbitrary, path, based on the manner in which the planner changes the optimization constraints/weights during planning. Thus, the planner usually never fully understa ... Full text Cite

SU‐GG‐J‐81: Efficacy of Patient Setup Correction Procedure in Prostate Radiotherapy

Conference Medical Physics · January 1, 2008 Purpose: Using an on‐board cone‐beam CT (CBCT) based statistical margin model to determine whether a prostate center‐of‐mass (COM) based translation correction procedure can significantly reduce the CTV‐to‐PTV margin required for prostate patients who were ... Full text Cite

SU‐GG‐I‐52: Conversion of On‐Board Digital TomoSynthesis (DTS) to HU Values

Conference Medical Physics · January 1, 2008 Purpose: To investigate a method to convert the pixel values of DTS images to HU values with reference HU values from CT images. Method and Materials: This study included CT and DTS images of two phantoms (Catphan and a chest phantom) and three patients (p ... Full text Cite

SU‐GG‐J‐119: Localization Accuracy of Target Verification System Using Digitial Tomosynthesis (DTS)

Conference Medical Physics · January 1, 2008 Purposes: A research platform was developed for target verification using digital tomosynthesis (DTS). To verify its accuracy, a phantom study was conducted and several clinical cases were investigated. Method and Materials: customer‐developed reconstructi ... Full text Cite

SU‐GG‐I‐53: The Impact of Scan Angles On the Visibility of Anatomy in On‐Board Digital Tomosynthesis (DTS) Images for Head and Neck Cancer Patients: A Single‐Observer Study

Conference Medical Physics · January 1, 2008 Purpose: To assess the impact of scan angles on the visibility of anatomy in on‐board digital tomosynthesis (DTS) images as a means to optimize this technique. Method and Materials: Head and neck cancer patients undergoing intensity‐modulated radiotherapy ... Full text Cite

TU‐EE‐A3‐03: On‐Board Four‐Dimensional Digital Tomosynthesis (4D‐DTS): Optimization of Respiratory Motion Dependent Acquisition and Reconstruction Parameters

Conference Medical Physics · January 1, 2008 Purpose: Amplitude and period of respiratory motion vary among patients. For four‐dimensional digital tomosynthesis (4D‐DTS), the frequency of projection acquisition and the phase window must be optimized based on respiratory motion. The purpose of this st ... Full text Cite

TH‐D‐351‐02: A Novel Digital Tomosynthesis (DTS) Reconstruction Method Using Prior Information and a Deformation Model

Conference Medical Physics · January 1, 2008 Purpose: Digital Tomosynthesis (DTS) is a quasi‐3D imaging technique which reconstructs images from a limited angle of on‐board projections with significantly lower dose and shorter acquisition time than full cone‐beam CT (CBCT). However, DTS images recons ... Full text Cite

SU‐GG‐I‐47: A New Limited‐Angle CT Reconstruction Method Based On Total‐Variation Minimization

Conference Medical Physics · January 1, 2008 Purpose: To develop a new CT reconstruction algorithm based on Total‐Variation (TV) minimization. The new algorithm is specifically designed for limited angle reconstruction to alleviate volume information loss caused by incomplete projections. Method and ... Full text Cite

SU‐GG‐T‐53: Integrating An Online Adaptive IMRT Process to the Prostate IGRT

Conference Medical Physics · January 1, 2008 Purpose: To investigate the feasibility of a novel online IMRT re‐optimization process. This online process can be an integral part to the current prostate IGRT paradigm to augment the existing patient alignment techniques for cases with complex daily orga ... Full text Cite

SU‐GG‐T‐13: Fast Seed Localization On MR Images For Post‐Prostate Implant Dosimetry

Conference Medical Physics · January 1, 2008 Purpose: Accurate and reliable post‐prostate implant dosimetric analysis requires optimal identification of the seeds on CT and optimal description of soft tissues on MRI. We present a fast seed localization technique for MRI that is also robust from motio ... Full text Cite

SU‐GG‐T‐54: On‐Line Adaptive IMRT for Prostate Cancer

Conference Medical Physics · January 1, 2008 Purpose: This study proposes a novel on‐line IGRT technique that can modify the original IMRT plan to match with the “anatomy‐of‐the‐day” within few minutes. The performance of this technique is compared with current on‐line IGRT strategies using bone/soft ... Full text Cite

SU‐GG‐J‐47: Clinical Implementation of An Integrated System for Image‐Guided Radiation Therapy (IGRT) and Adaptive Radiation Therapy (ART)

Conference Medical Physics · January 1, 2008 Purpose: It is critical that image‐guided radiation therapy (IGRT) and adaptive radiation therapy (ART) are performed with clearly defined goals without abusing the technologies. This study illustrates the current integrated system that provides efficient ... Full text Cite

SU‐GG‐T‐538: Dosimetric Effect of Energy Spread of Proton Beams

Conference Medical Physics · January 1, 2008 Purpose: To investigate how proton beam energy spreads dosimetrically affect proton plans. Method and Materials: Scanning proton beams were simulated using the Monte Carlo method. A computer program was developed to calculate the weights to produce the SOB ... Full text Cite

SU‐GG‐T‐255: Experimental Verification of Lung Tumor Dose with Radiochromic Film

Conference Medical Physics · January 1, 2008 Purpose: To assess the absorbed doses in and around lung tumor by performing radiochromic film measurements. Method and Materials: A phantom was made to have a water equivalent central core, a low‐density middle layer and a water equivalent outer layer to ... Full text Cite

SU‐GG‐J‐183: The Use of Video Feedback for the Improvement of Respiratory Gating Radiation Treatments

Conference Medical Physics · January 1, 2008 Purpose: Breath‐hold respiratory gating is currently being used to improve the quality of radiotherapy, especially for sites subject to internal motion. One technical challenge that exists is patient regulation of respiration. Typically, the radiation ther ... Full text Cite

MO‐D‐AUD C‐01: Targeting Using Surrogates

Conference Medical Physics · January 1, 2008 While technology for image guided radiotherapy (IGRT) has advanced dramatically over the past few years, the basic fact remains that the actual treated target remains poorly or not at all visible using most in‐room imaging technologies. As a result, target ... Full text Cite

Onboard SPECT for Biological Target Localization

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

Investigation of a Support Vector Model to Predict Lung Radiotherapy (RT) Induced Pneumonitis (RP)

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

Optimal Beam Selection to Enhance SPECT-Guided Reduction of IMRT Dose to Functioning Lung

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

The Effect of Scan Angle on Target Localization Accuracy Using Digital Tomosynthesis

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

Impact of Advanced Technologies on the Rate of Deviations in Radiation Treatment Delivery

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

Implementation of Digital Tomosynthesis for On-Board Target Localization of Radiotherapy

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

SU‐FF‐T‐148: Developing a Convenient and Effective IMRT QA Procedure Using MLC Dynalog Files

Conference Medical Physics · January 1, 2007 Purpose: To develop a convenient and effective patient‐specific IMRT quality assurance (QA) procedure utilizing MLC dynalog files. Method and Materials: IMRT plans are delivered with multi‐leaf collimators (MLC). The complexity of MLC motion and patterns m ... Full text Cite

SU‐FF‐T‐246: Implementation of Helical CT Source in DOSXYZnrc/EGSnrc Monte Carlo Code

Conference Medical Physics · January 1, 2007 Purpose: To implement and verify a new source type — phase‐space source in helical mode in DOSXYZnrc/EGSnrc Monte Carlo (MC) code. Method and Materials: To implement a new source type — “phase space source in helical mode” in DOSXYZnrc/EGSnrc, we modified ... Full text Cite

SU‐FF‐J‐105: Predicting Late Skin Effects Using Digital Infrared Imaging for Breast Cancer Patients Treated with Radiation

Conference Medical Physics · January 1, 2007 Purpose: Establish a methodology based on digital infrared imaging (DII) to predict skin reaction after breast irradiation using the Skin Radiosensitivity Index (SRI) derived from early skin temperature changes. Method and Materials: Five breast cancer pat ... Full text Cite

SU‐FF‐J‐58: Clinical Evaluation Using Digital Tomosynthesis for Positioning Verification of Breath‐Hold Liver Treatment

Conference Medical Physics · January 1, 2007 Purpose: To demonstrate clinical feasibility of generating digital tomosynthesis (DTS) in a single breath‐hold (BH) period compared to multiple BH periods for CBCT acquisition and to examine on‐board BH‐DTS as an efficient alternative to BH‐CBCT for target ... Full text Cite

SU‐FF‐J‐48: Three‐Dimensional MRI and Cone‐Beam CT Matching for Localization of Prostate Cancer Treatment

Conference Medical Physics · January 1, 2007 PURPOSES: There is a growing interest using MRI only for prostate cancer treatment planning. This study is aimed to investigate clinical feasibility of matching 3D planning MRI to on‐board cone‐beam CT (CBCT) images for target localization. Materials and M ... Full text Cite

On-line adaptive planning system for prostate IMRT treatment

Conference INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS · January 1, 2007 Link to item Cite

SU‐FF‐T‐252: Improvement of Localization Accuracy by Using 3D Cone Beam CT for Stereotactic Body Radiation Therapy of Liver, Lung and Spine Lesions

Conference Medical Physics · January 1, 2007 Purpose: To compare treatment isocenter placement based on OBI 2D kV imaging and OBI 3D‐CBCT imaging for patients undergoing SBRT, and compare the CBCT based isocenter shifts among liver, lung and spine lesions. Material and Methods: 119 SBRT fractions wer ... Full text Cite

Improved target localization with 3D cone beam CT On-Board Imaging in stereotactic body radiation therapy

Conference INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS · 2007 Link to item Cite

SU‐FF‐J‐54: A Hybrid Multiresolution Method for Automatic Registration Between Reference and On Board Digital Tomosynthesis

Conference Medical Physics · January 1, 2007 Purpose: Automatic registration between reference and on‐board digital tomosynthesis (DTS) is a critical step for target localization using DTS. We previously developed an approximate method for automatic registration between reference and on‐board DTS, in ... Full text Cite

SU‐FF‐I‐39: Development of Clinical Application Platform Using Digital Tomosynthesis for Target Localization

Conference Medical Physics · January 1, 2007 Purpose: To develop a workstation for clinical application of digital tomosynthesis (DTS) for real‐time target localization. Specifically, to accelerate the reconstruction both digitally‐reconstructed radiograph (DRR) and DTS using ultra‐fast interpolation ... Full text Cite

TH‐D‐M100F‐01: An Evaluation of Noise in Radiotracer Emission Imaging Using Flat‐Panel Detectors

Conference Medical Physics · January 1, 2007 Purpose: Single Photon Emission Computed Tomography (SPECT) onboard radiation therapy machines could enable the use of functional and molecular imaging in guiding the therapy beam and in monitoring disease. Costs and spatial constraints of onboard SPECT mi ... Full text Cite

SU‐FF‐T‐172: Dosimetric Comparison of MapCheck with Monte Carlo Simulations

Conference Medical Physics · January 1, 2007 Purpose: This study is to verify IMRT QA MapCheck measurement using Monte Carlo simulations. Method and Materials: MapCheck (Sun Nuclear) contains 445 silicon diode detectors arranged in a 22×22‐cm2 area, of which 221 are located in the 10×10 cm ... Full text Cite

SU‐FF‐T‐326: On the Use of Ice as a Water‐Equivalent Solid Medium for Brachytherapy Dosimetry Measurement

Conference Medical Physics · January 1, 2007 Purpose: It is well‐known that fluctuation in chemical compositions can lead to significant errors in the dosimetry of low‐energy brachytherapy sources using the traditional “water‐equivalent” solid phantoms. The aim of this work was to investigate the fea ... Full text Cite

SU‐FF‐J‐24: Toward Real‐Time Tracking of HDR Source Position Using Emission Imaging with a Collimator and Flat‐Panel Detector

Conference Medical Physics · January 1, 2007 Purpose: High dose rate (HDR) brachytherapy delivers rapidly a large, highly spatially varying dose. Consequently, precise quality assurance of source location and dwell time is important. Here, we propose that, with no additional radiation exposure to the ... Full text Cite

SU‐FF‐T‐438: Using Diode Dosimeters to Characterize Dose in the Buildup Region of High‐Energy Photon Beams

Conference Medical Physics · January 1, 2007 Purpose: For external photon beams, the depth dependence of the stopping power ratio between air and water in the buildup region is difficult for accurate quantitative characterization. Qualitatively the depth dependence increases as the photon energy incr ... Full text Cite

SU‐FF‐T‐14: A High MU Efficiency Dynamic MLC Leaf Sequencing Algorithm

Conference Medical Physics · January 1, 2007 Purpose: MU efficiency is a major figure of merit for dMLC leaf sequencing. However, leaf sequencing is often generated with focus on other constraints and the MU efficiency is taken as a byproduct. This work is to develop a new dMLC leaf sequencing algori ... Full text Cite

TU‐FF‐A3‐05: Real‐Time Lung Tumor Motion Prediction Using Neural Network Based Models Constructed From Unsorted Cine CT Images

Conference Medical Physics · January 1, 2007 Purpose: To develop neural network based models for predicting respiratory induced tumor motion from gating signals and unsorted cine CT images. The ability of the models to predict target motion given real‐time surrogate marker motion was verified using a ... Full text Cite

TH‐D‐AUD‐07: The Impact of SBRT Treatment Techniques On Dose Delivery in Presence of Organ Motion and Deformation

Conference Medical Physics · January 1, 2007 Purpose: The impact of organ motion and deformation has been studied for conventional radiation therapy. The cumulative dose is usually a blurred version of the static plan after motion‐induced hot and cold spots average out over a large number of fraction ... Full text Cite

TH‐E‐M100F‐07: Amplitude Gated Breath‐Hold Treatment for Upper Abdominal Lesions with On Board Imaging Guidance

Conference Medical Physics · January 1, 2007 Purpose: To apply on‐boardmdash;image (OBI) guided amplitude gating for breath‐hold treatment and to assess treatment margin adequacy by analyzing the isocenter placement based on orthogonal 2D kV radiographs and 3D cone‐beam CT (CBCT) acquired under ampli ... Full text Cite

SU‐DD‐A3‐04: On‐Line Re‐Optimization of Prostate IMRT Plans for Image Guided Adaptive Radiation Therapy

Conference Medical Physics · January 1, 2007 Purpose: This study proposes a novel on‐line adaptive planning technique for the prostate treatment by directly re‐optimizing the IMRT plan based on both the “anatomy‐of‐the‐day” and the original plan information. Method & Materials: Using a commercial tre ... Full text Cite

WE‐E‐M100F‐01: 3D Interfraction Position Verification for Patients Undergoing Partial Breast Irradiation: Comparing Digital Tomosynthesis to Cone‐Beam CT

Conference Medical Physics · January 1, 2007 Purpose: This clinical study evaluates digital tomosynthesis (DTS) technology for daily imaging guidance for partial breast irradiation (PBI) and compares its positioning accuracy to the 3D CBCT technique. Compared to CBCT, DTS offers lower imaging dose an ... Full text Cite

TU‐EE‐A3‐03: Performing Concurrent Kilovoltage Imaging While Delivering Megavoltage Treatment Beams

Conference Medical Physics · January 1, 2007 Purpose: To investigate the clinical feasibility of performing concurrent kilovoltage (kV) x‐ray imaging while the patient at the treatment position was irradiated by megavoltage (MV) beams. Method and Materials: Anatomical visibility and contrast details ... Full text Cite

SU‐FF‐J‐57: A Phantom Study On the 3‐D Target Localization Accuracy Using CBCT of An On‐Board Imager

Conference Medical Physics · January 1, 2007 Purpose: To evaluate the three‐dimensional target localization accuracy using CBCT of an On‐Board Imager (OBI) system by determining the detection error and residual error associated with image registration and patient repositioning. Method and Materials: ... Full text Cite

SU‐FF‐T‐377: Self‐Learning AI Technique for Parameter Optimization of IMRT Treatment Planning

Conference Medical Physics · January 1, 2007 Purpose: The conventional application of Fuzzy Inference System (FIS) on parameter optimization of IMRT treatment planning requires that the FIS model (membership function, inference rules) to be predetermined in an intuitive way based on prior planner's k ... Full text Cite

SU‐FF‐J‐68: Dosimetric Comparison of Patient‐Specific Margins Vs. Uniform Margins for Prostate IMRT Treatments

Conference Medical Physics · January 1, 2007 Purpose: To evaluate the dosimetric improvement of IMRT treatment plans generated with patient‐specific margins compared to uniform margins for prostate cancer patients. Methods and Materials: For 13 prostate cancer patients who underwent IMRT treatment, d ... Full text Cite

A quality assurance program for the on-board imager®

Conference Ifmbe Proceedings · January 1, 2007 Purpose: To develop a comprehensive quality assurance (QA) program for the On-Board Imager (OBI) used for patient positioning verification and to present the results of QA tests over extended periods from multiple institutions. Radiographic and cone-beam c ... Full text Cite

SU‐FF‐T‐88: Augmenting Lyman NTCP by Adding the Influence of Non‐Dose Variables Via Decision Trees: Application to Lung Radiation‐Pneumonitis Prediction

Conference Medical Physics · January 1, 2007 Purpose: Develop a model that augments the dose‐based parametric Lyman NTCP formulation using non‐parametric decision trees that can additionally account for the influence of non‐dose variables. Apply and test the model to predict Grade 2+ lung radiotherap ... Full text Cite

SU‐FF‐T‐300: Monte Carlo Benchmark for Radiation Dose Assessment in Varian On‐Board Imager

Conference Medical Physics · January 1, 2007 Purpose: To evaluate radiation dose in kV cone‐beam computed tomography (CBCT) and to benchmark Monte Carlo (MC) simulations in the PMMA CT phantoms Method and Materials: Using an On‐Board Imager (Varian Medical Systems), we measured absorbed doses to the ... Full text Cite

TH‐E‐M100E‐03: Optimizing the Methodology for Incorporating SPECT‐Guidance to Reduce Intensity Modulated Radiation Therapy (IMRT) Dose to Functioning Lung

Conference Medical Physics · January 1, 2007 Purpose: Single photon emission computed tomography (SPECT) provides a spatial distribution map of lung perfusion. Previously, an algorithmic methodology was developed using IMRT and SPECT guidance to deliberately divert dose away from higher functioning ( ... Full text Cite

Feasibility of cone-beam CT based treatment planning

Conference Ifmbe Proceedings · January 1, 2007 Purpose: This study investigates feasibility of CBCT-based treatment planning. Methods and materials: Hounsfield unit (HU) values and profiles of phantoms and patients in CBCT images were compared to those in CT images. CBCT-based treatment plans for the p ... Full text Cite

SU‐FF‐J‐81: Estimation of Dose Variations During Prostate Radiation Treatment Due to Elastic Deformations of Soft Tissues

Conference Medical Physics · January 1, 2007 Objective: The true dose distribution is subject to change due to organ shifts and also deformations. The goal of this work is to estimate the effect of the elastic organ deformations on the dose distribution for the average prostate IMRT treatment. Method ... Full text Cite

2824

Conference International Journal of Radiation Oncology*Biology*Physics · November 2006 Full text Cite

2882

Conference International Journal of Radiation Oncology*Biology*Physics · November 2006 Full text Cite

TH‐C‐330A‐05: Analysis of the Point Spread Function of Isocentric Digital Tomosynthesis (DTS)

Conference Medical Physics · January 1, 2006 Purpose: This project presents an analysis of the point spread function (PSF) of isocentric digital tomosynthesis (DTS). DTS is a limited angle 3‐ dimensional reconstruction from cone beam projections, with high resolution for excellent imaging of both bon ... Full text Cite

SU‐FF‐I‐19: A Study of Megavoltage Beam Tomosynthesis

Conference Medical Physics · January 1, 2006 Purpose: To study the impact of projection numbers on the quality of tomosynthesis images using megavoltage beams. Method and Materials: It has been shown that isocentric kilovoltage tomosynthesis images can be generated with no more than 50 degree scan an ... Full text Cite

SU‐FF‐T‐208: Efficient Selection of Beam Number and Orientations for Intensity Modulated Radiotherapy (IMRT) by Emulating An Ideal Dose Distribution

Conference Medical Physics · January 1, 2006 Purpose: Since radiotherapy treatments only utilize a limited number of beams, it is important that these beams be carefully selected to extract maximum benefit. Here we propose a novel, fast, scheme that selects beam number and orientations for IMRT with ... Full text Cite

WE‐E‐ValA‐03: Dosimetric Evaluation of Prostate IMRT Treatments Positioned Based On Cone‐Beam CT

Conference Medical Physics · January 1, 2006 Purpose: To evaluate the dosimetric consequence of 3D positioning verification for prostate IMRT treatment using CBCT. Method and Materials: Patients in this study were repositioned using 2D orthogonal radiographic images, taken prior to treatment to match ... Full text Cite

TH‐C‐ValB‐04: Evaluation of the Quality of 3D‐3D Mutual Information (MI) Shared Between Reference and On‐Board DTS Images

Conference Medical Physics · January 1, 2006 Purpose: Digital tomosynthesis (DTS) is a fast, low‐dose method for reconstructing 3‐D slices from 2‐D cone‐beam x‐ray projection data acquired with limited source angulation (e.g., 40°). We previously developed a method for reconstructing reference DTS (R ... Full text Cite

SU‐FF‐I‐09: Minimizing Scatter Artifact in Cone‐Beam CT Reconstruction Using Both Kilovoltage and Megavoltage Beams

Conference Medical Physics · January 1, 2006 Purpose: To study the effect of imaging orientations on image quality of aggregated conebeam CT and to develop a strategy to minimize scatter artifact. Method and Materials: Orthogonal kilovoltage (kV) and megavoltage (MV) beam projections were acquired an ... Full text Cite

SU‐DD‐A4‐01: Quantifying Skin Effects After Accelerated Partial Breast Irradiation Using Digital Infrared Imaging (DII): Preliminary Feasibility Data

Conference Medical Physics · January 1, 2006 Purpose: Accelerated partial‐breast irradiation (APBI) is an emerging radiation technique that challenges standard whole breast irradiation. The larger fraction sizes used in these hypofractionated schedules may increase the risk of late normal tissue effe ... Full text Cite

SU‐FF‐T‐66: A Technique for Cone‐Beam CT‐Guided Stereotactic Body Radiation Therapy

Conference Medical Physics · January 1, 2006 Purpose: To develop and assess a technique using cone‐beam CT (CBCT) to localize treatment targets for stereotactic body radiation therapy (SBRT). Material and Methods: Patients selected for SBRT had 3‐D or 4‐D CT simulation with immobilization. GTV, CTV, ... Full text Cite

SU‐FF‐T‐219: Evaluation of a Practical and Low Cost Gafchromic Film/flat‐Bed Scanner Combination for Planar Dosimetry

Conference Medical Physics · January 1, 2006 Purpose: To assess the accuracy and practicality of using GAFCHROMIC® EBT Film in combination with an Epson flat‐bed scanner for the verification of advanced treatment techniques in radiation therapy. EBT is a new type of Gafchromic film with high sensitiv ... Full text Cite

SU‐CC‐ValA‐01: Automatic Comparison Between Reference and On Board Digital Tomosynthesis for Target Localization

Conference Medical Physics · January 1, 2006 Purpose: Digital tomosynthesis (DTS) is a method for reconstructing 3D images from cone‐beam projection data acquired with limited angulation (e.g., 40°) of an x‐ray source, and is much faster and lower dose than full cone‐beam CT (CBCT). We previously dev ... Full text Cite

TU‐FF‐A3‐02: Preliminary Investigations Into Combined CT/SPECT Imaging Onboard Therapy Machines

Conference Medical Physics · January 1, 2006 Purpose: Functional and molecular (F&M) imaging onboard radiation therapy machines would allow for targeting of functional tumor volume, and avoiding of healthy tissue, by guiding and modifying radiation beams, in the treatment room, based on real‐time F&M ... Full text Cite

SU‐FF‐T‐263: Imaging with Brachytherapy Sources

Conference Medical Physics · January 1, 2006 Purpose: To demonstrate the concept of 2D projection and 3D volumetric imaging using brachytherapy treatment sources in patient prior to or during treatment. Method and Materials: As shown Figure 1, an Ir‐192 HDR catheter is placed at 15 cm depth (a reason ... Full text Cite

SU‐FF‐T‐221: Evaluation of An Electron Monte Carlo Dose Calculation Algorithm for Electron Beam Radiotherapy

Conference Medical Physics · January 1, 2006 Purpose: To systematically evaluate the electron Monte Carlo (eMC) dose calculation algorithm of the Eclipse treatment planning system and to identify factors that affect its calculation accuracy. Method and Materials: Percent depth dose (PDD) and profiles ... Full text Cite

SU‐FF‐T‐151: Conservation of Integrated Reference Air Kerma

Conference Medical Physics · January 1, 2006 Purpose: To demonstrate the conservation rule of the integrated reference air kerma (IRAK). Method and Materials: For a brachytherapy photon source whose radial dose functions is flat over the clinical distance range, the dose falls off with the inverse sq ... Full text Cite

SU‐FF‐J‐22: An Image Based Statistical Shape Model and Its Application in Radiotherapy Margin Design

Conference Medical Physics · January 1, 2006 Purpose: A novel imaging based model is proposed to describe the stochastic nature of the shape and location of a volume of interest (VOI). Based on the VOIs in sequential patient images, the model can predict the probability that a specific point will bel ... Full text Cite

SU‐FF‐I‐17: Reduction of Set‐Up Error Using Cone Beam‐CT in Patients Undergoing Partial Breast Irradiation

Conference Medical Physics · January 1, 2006 Purpose: Partial breast irradiation with multiple external beams requires accurate alignment of the target volume and treatment isocenter. On‐board plannar kV/MV imaging can verify set‐up based on boney landmarks. On‐board cone beam CT (CBCT) may provide a ... Full text Cite

SU‐EE‐A1‐04: Verifying Internal Target Volume Using Cone‐Beam CT for Stereotactic Body Radiotherapy Treatment

Conference Medical Physics · January 1, 2006 Purpose: The internal target volume (ITV) could be determined using 4D CT simulation images and be verified in the treatment room using on‐board cone‐beam CT (CBCT) since the CBCT projection images are acquired over approximately 10 breathing cycles. This ... Full text Cite

SU‐FF‐T‐432: Time‐Delay Measurement of a Varian Real‐Time Position Management System

Conference Medical Physics · January 1, 2006 Purpose: Respiratory gating systems have been developed to reduce treatment uncertainty caused by organ motions related to respiration. The time‐delay between when the gating signal is triggered and when the beam is turned on may affect the actual radiatio ... Full text Cite

SU‐FF‐J‐86: Intra‐ and Inter‐Breath‐Hold Position Variations for OBI Guided Amplitude Gating Treatment with Breath Hold

Conference Medical Physics · January 1, 2006 Purpose: We have applied OBI guidance together with a respiratory gating system to effectively control patient positioning for amplitude gating treatment with breath hold. The deep inspiration breath‐hold treatment has been proven effective in reducing the ... Full text Cite

MO‐A‐224C‐01: Daily Localization I: KV/CBCT

Conference Medical Physics · January 1, 2006 Daily target localization is a critical step to secure accurate delivery for 3‐D conformal radiation therapy and intensity‐modulated radiation therapy. One emerging technology using in‐room kilovoltage (kV) imaging has shown to be very promising for target ... Full text Cite

SU‐FF‐J‐16: A Tool for Off‐Line Review of 3D Target Verification and Localization with Cone‐Beam Computed Tomography

Conference Medical Physics · January 1, 2006 Purpose: To implement a clinical tool for off‐line review of Cone‐Beam Computed Tomography (CBCT) based 3D target verification and localization. Methods and Materials: An in‐house 3D target localization and verification tool is being developed to allow phy ... Full text Cite

SU‐FF‐J‐118: Respiration Phase‐Based Cone‐Beam Computed Tomography (CBCT) Reconstruction

Conference Medical Physics · January 1, 2006 Purpose: To develop a method to reconstruct CBCT data based on projection data acquired at a specific respiration phase. Methods and Materials: The original projection data were acquired using an on‐board imager (OBI) (Varian Medical Systems) over scanning ... Full text Cite

SU‐FF‐T‐124: Clinical Evaluation of the Performance of a Fuzzy Logic Guided Parameter Optimization for Inverse Treatment Planning

Conference Medical Physics · January 1, 2006 Purpose: To evaluate the effectiveness of a Fuzzy Logic guided parameter optimization method for inverse treatment planning, in comparison with the results achieved by routine trial‐and‐error method. Method and Materials: The optimization algorithm was dev ... Full text Cite

SU‐FF‐J‐96: Modeling Correlation Between External Surface Motion and Internal Organ Motion Based On 4DCT

Conference Medical Physics · January 1, 2006 Purpose: To develop a method for modeling the dynamic relationship between patient surface motion and internal target motion using 4DCT data. Then, to verify its capability to interpolate internal target motion with real‐time patient surface motion informa ... Full text Cite

SU‐FF‐T‐374: Quality Assurance of the On‐Board Imager and Cone‐Beam Computed Tomography Systems

Conference Medical Physics · January 1, 2006 Purpose: To develop a comprehensive quality assurance (QA) program for the On‐Board Imager (OBI) used for patient positioning verification and to present the results of QA tests over extended periods from multiple institutions. Radiographic and cone‐beam c ... Full text Cite

TH‐C‐224C‐09: Using SPECT‐Guidance to Reduce Intensity Modulated Radiation Therapy (IMRT) Dose to Functioning Lung

Conference Medical Physics · January 1, 2006 Purpose: Single photon emission computed tomography (SPECT) provides a map of the spatial distribution of lung perfusion. Thus, SPECT guidance can be used to deliberately divert dose away from higher functioning lung, thereby potentially reducing lung toxi ... Full text Cite

TU‐FF‐A2‐01: Feasibility of Cone‐Beam CT Based Treatment Planning

Conference Medical Physics · January 1, 2006 Purpose: To investigate the feasibility of cone‐beam computed tomography (CBCT)‐based treatment planning. Methods: HU of material disks in Catphan, HU profiles for homogeneous and inhomogeneous phantoms, and HU values in different tissue areas of brain, th ... Full text Cite

Improved Prediction of Radiation Pneumonitis using Multiple Additive Regression Trees

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

Online Digital Tomosynthesis (DTS): A Novel Technique for Improving Target Localization in Radiation Therapy

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

Extrapolating Organ Motion Margin for Radiation Fields from Sequential Patient Images

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

Heart Dose Reduction for Radiation Treatments of Left-Sided Breast Cancer by Using 4D Simulation and 4D Verification

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

SU‐FF‐J‐70: Respiratory Gated Radiation Therapy Directly Using Patient's Fluoroscopic Images Instead of External Or Internal Markers

Conference Medical Physics · January 1, 2005 Purpose: To develop a respiratory gated radiation therapy (RGRT) technique by directly matching the patient's anatomical structures acquired during the imaging cycles to that in a reference image. Method and Materials: Studies showed that the external mark ... Full text Cite

SU‐FF‐J‐30: Quantification of Normal Organ Motion Due to the Respiratory and Cardiac Cycles

Conference Medical Physics · January 1, 2005 Purpose: To quantify the degree of normal organ motion due to the respiratory and cardiac cycles. Better definition of such motion may be useful in defining field margins and in assessing the utility of gating technologies. Method and Materials: Four healt ... Full text Cite

SU‐FF‐J‐57: Digital Tomosynthesis for Verification of Radiation Therapy Positioning: Preliminary Results From a Kilovoltage On‐Board Imaging System

Conference Medical Physics · January 1, 2005 Purpose: This study introduces a new radiation therapy target localization technique using online digital tomosynthesis (DTS), a method for reconstructing 3‐D slices from 2‐D projection data acquired with limited source motion. By separating the visualizat ... Full text Cite

SU‐EE‐A4‐04: Compartment Modeling Analysis of Cu‐ATSM Dynamic PET Images

Conference Medical Physics · January 1, 2005 Purpose: Copper labeled diacetyl‐bis(N4‐methylthiosemicarbazone) (Cu‐ATSM) has been reported to selectively bind to hypoxic tumor cells. This makes Cu‐ATSM PET a promising modality to image tumor hypoxia. However, intravascular Cu‐ATSM that is not related ... Full text Cite

SU‐FF‐T‐186: Commissioning of Tissue Inhomogeneity Correction of Eclipse Radiation Treatment Planning System Using a Lung Phantom

Conference Medical Physics · January 1, 2005 Purpose: It has been noted that dosimetric difference due to tissue inhomogeneity is significant for a lung patient. If there is no tissue inhomogeneity correction (IC) made, the treatment plan could mislead treatment. Commercial radiation treatment planni ... Full text Cite

SU‐FF‐J‐80: Clinical Procedures for Daily Patient Setup Verification Using On‐Board Imager (OBI)

Conference Medical Physics · January 1, 2005 Purpose: The newly installed OBI system consists of a kilo‐voltage (KV) X‐ray source and a flat‐ panel detector mounted orthogonally to the megavoltage portal imager (MV) in Varian 21EX machine. These devices are linked to the OBI workstation which provide ... Full text Cite

Development of a computerized portal verification system for radiation therapy of breast cancers

Conference Proceedings of SPIE the International Society for Optical Engineering · May 12, 1995 A fully automated system is being developed for the portal verification of tangential breast fields in radiation therapy of breast cancer. The automated verification system involves image acquisition, image feature extraction, feature correlation between r ... Full text Cite

Computer-aided detection and diagnosis of masses and clustered microcalcifications from digital mammograms

Conference Proceedings of SPIE the International Society for Optical Engineering · July 29, 1993 We are developing an "intelligent" workstation to assist radiologists in diagnosing breast cancer from mammograms. The hardware for the workstation will consist of a film digitizer, a high speed computer, a large volume storage device, a film printer, and ... Full text Cite

Computerized detection and characterization of mass lesions in digital mammography

Conference Conference Proceedings IEEE International Conference on Systems Man and Cybernetics · January 1, 1992 We are developing computer-aided diagnosis schemes for the detection of breast lesions in digital mammograms. The detection scheme employs a bilateral-subtraction technique that is based on the normal symmetry between the left and right breast images. The ... Full text Cite