ConferenceMed Phys · May 2022
PURPOSE: To develop a deep learning model design that integrates radiomics analysis for enhanced performance of COVID-19 and non-COVID-19 pneumonia detection using chest x-ray images. METHODS: As a novel radiomics approach, a 2D sliding kernel was implemen ...
Full textLink to itemCite
ConferencePhys Med Biol · December 6, 2021
Objective:To design a deep transfer learning framework for modeling fluence map predictions for stereotactic body radiation therapy (SBRT) of adrenal cancer and similar sites that usually have a small number of cases.Approach:We developed a transfer learni ...
Full textLink to itemCite
ConferenceInternational journal of radiation oncology, biology, physics · November 2021
Purpose/objective(s)To compare dosimetric results of two beam arrangement strategies and their robustness to setup uncertainties in fractionated thoracic spine Stereotactic Body Radiotherapy (SBRT) MATERIALS/METHODS: Fifteen patients who received ...
Full textCite
ConferenceInternational journal of radiation oncology, biology, physics · November 1, 2020
This article has been retracted: please see Elsevier Policy on Article Withdrawal (http://www.elsevier.com/locate/withdrawalpolicy). This abstract has been retracted at the request of the authors. After submitting this abstract the authors realized that th ...
Full textCite
ConferenceFrontiers in oncology · January 2020
Purpose To develop a deep learning-based AI agent, DDD-PIOP (Dose-Distribution-Driven PET Image Outcome Prediction), for predicting 18FDG-PET image outcomes of oropharyngeal cancer (OPC) in response to intensity-modulated radiation therapy (IMRT). Methods ...
Cite
Conference2019 International Conference on Medical Imaging Physics and Engineering Icmipe 2019 · November 1, 2019
Four-dimensional MRI (4D-MRI) is an emerging technique for soft-tissue motion management in radiotherapy treatment planning. The purpose of this study was to develop a novel image mutual information (MI) based retrospective 4DMRI sorting method that is ful ...
Full textCite
ConferenceJournal of Physics Conference Series · August 29, 2019
We investigated the feasibility of using N-isopropylacrylamide (NIPAM) dosimeters with x-ray CT to verify radiosurgery dose. Dosimeters were prepared at one facility and shipped to a second facility for irradiation. A simulation CT was acquired and plans p ...
Full textCite
ConferenceTechnology in Cancer Research and Treatment · January 1, 2019
Knowledge models in radiotherapy capture the relation between patient anatomy and dosimetry to provide treatment planning guidance. When treatment schemes evolve, existing models struggle to predict accurately. We propose a case-based reasoning framework d ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2019
The purpose of the present study was to develop and evaluate a practical dual-energy imaging approach for enhancing on-board cone-beam CT (CBCT) image quality for brain radiotherapy applications. The proposed primary technique involves a projection domain ...
Full textCite
ConferenceOptics Infobase Conference Papers · January 1, 2017
We combined large sample resin embedding with immunofluorescence staining to acquire biomolecules profiles with high spatial-resolution. After evaluating the compatibility of this method and filtering embedding resin, we achieved to high-resolution image i ...
Full textCite
ConferenceOptics Infobase Conference Papers · January 1, 2017
To precisely locate mRNAs of mouse brain, a simple, rapid method was developed via combining whole mount in situ hybridization and fluorescence tomography, with cytoarchitectonic landmarks provided by propidium iodide real-time counterstaining during the i ...
Full textCite
ConferencePract Radiat Oncol · 2016
OBJECTIVE: Our purpose was to address challenges associated with single-isocenter radiosurgery for multiple intracranial targets (SIRMIT) including increased sensitivity to rotational uncertainties (resulting from distance of the targets from isocenter) as ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To develop a technique to generate on-board VC-MRI using patient prior 4D-MRI, motion modeling and on-board 2D-cine MRI for real-time 3D target verification of liver and lung radiotherapy. METHODS: The end-expiration phase images of a 4D-MRI acqui ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To investigate the feasibility of using region-based principal component analysis (PCA) for motion modeling to estimate on-board 4D-CBCT using prior information and limited angle projections for potential 4D target verification of lung radiotherap ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: Target tracking or gating the radiation beam using real-time imaging and surrogate motion monitoring methods are employed for dynamic tracking treatment or respiratory-gated radiotherapy. This method requires tumor motion prediction far enough in ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To investigate the dosimetric accuracy of CBCTs estimated by a motion modeling and free-form deformation(MM-FD) technique for radiotherapy of lung cancer. METHODS: Various inter-fractional variations featuring patient motion pattern change, tumor ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To facilitate fast and accurate iterative volumetric image reconstruction from limited-angle on-board projections. METHODS: Intrafraction motion hinders the clinical applicability of modern radiotherapy techniques, such as lung stereotactic body r ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To evaluate the dosimetry of microscopic disease (MD) region of lung cancer in stereotactic body radiation therapy (SBRT). METHODS: For simplicity, we assume organ moves along one dimension. The probability distribution function of tumor position ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To develop an automatic markerless 4D-CBCT projection sorting technique by using a patient respiratory motion model extracted from the planning 4D-CT images. METHODS: Each phase of onboard 4D-CBCT is considered as a deformation of one phase of the ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To evaluate the quality of monochromatic images at the same virtual monochromatic energy using dual cone-beam computed tomography (CBCT) with either kV/kV or MV/kV or MV/MV energy sets. METHODS: CT images of Catphan 504 phantom were acquired using ...
Full textLink to itemCite
ConferenceMedical Physics · June 2015
Purpose:We present an implementation of the knowledge‐based planning method utilizing a rapid learning approach which enables the accurate evolution of models as new data are collected during daily clinical practi ...
Full textCite
ConferenceIfmbe Proceedings · January 1, 2015
The purpose for this study is to develop robust and comprehensive knowledge models which can provide patient specific prediction of achievable dose distribution in radiation therapy plans for a wide range of cancer types. These models are useful tools to g ...
Full textCite
ConferenceIfmbe Proceedings · January 1, 2015
We present an efficient knowledge based automatic beam configuration determination method by utilizing patient-specific anatomy and tumor geometry information and a beam bouquet atlas. The proposed technique is based on learning the relationship between pa ...
Full textCite
ConferenceIfmbe Proceedings · January 1, 2015
The purpose of this study is to implement a rapid learning method to train the knowledge models to predict the organ-at-risk (OAR) dose sparing in radiation therapy (RT) based on an array of patient anatomical features. We also aim to establish the evaluat ...
Full textCite
ConferenceMed Phys · June 2013
PURPOSE: To evaluate the accuracy and sensitivity of a patient clinical objective IMRT QA tool using a 3D diode array. METHODS: A 3D QA device (Delta4, Scandidos Inc.) with 2 orthogonal diode array planes was used for IMRT QA. The diode spacing is 5mm in c ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: Volumetric modulated arc therapy (VMAT) is a relatively new treatment modality for dynamic photon radiation therapy. Pre-treatment quality assurance (QA) is necessary and many efforts have been taken to apply electronic portal imaging device (EPID ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: To evaluate breathing irregularity induced error in CBCT-based patient positioning in lung SBRT and correlate the error with a measure of breathing variability. METHODS: The 4D extended cardiac-torso (XCAT) digital phantom was used to generate 10- ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: Correct MLC modeling is essential to the accurate IMRT delivery. Most TPSs use simplified models with parameters of leaf transmission (LT) and dynamic leaf gap (DLG). The common way to determine them is through extrapolation from measurements. In ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: To develop a respiration-phase-matched DTS technique to monitor moving targets, and to evaluate its accuracy for various imaging parameters and anatomical characteristics Methods: Conventional methods, registering on-board DTS(OB-DTS, reconstructe ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: To develop an on-board 4D-CBCT(OB-4D-CBCT) reconstruction technique using prior information and limited-angle projections for 4D inter/intra-fractional target verificationMethods: The OB-4D-CBCT at each phase is considered as a deformation of plan ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: Electron beam therapy is under-utilized in radiation treatment of cancer and has remained practically unchanged for decades. We propose a new technique, Dynamic Electron Arc Radiotherapy (DEAR) with synchronized couch motion. In DEAR, gantry rotat ...
Full textLink to itemCite
ConferenceMedical Physics · January 1, 2013
Purpose: Single Photon Emission Computed Tomography (SPECT) may provide important information on tumors in the thorax and abdomen. Respiratory sorted imaging using conventional full cross‐section methods is generally degraded by noise. The purpose is to in ...
Full textCite
ConferenceMedical Physics · January 1, 2013
Purpose: Single Photon Emission Computed Tomography (SPECT) is one of the two predominant modes of nuclear emission tomography, the other being Positron Emission Tomography (PET). An important recent advance has been region‐of‐interest (ROI) SPECT for card ...
Full textCite
ConferenceMedical Physics · January 1, 2013
Purpose: To examine the effect of PET image reconstruction parameters on baseline and early‐treatment FDG‐PET/CT quantitative imaging. Early‐treatment changes in tumor metabolism in primary tumor and nodes can potentially determine if the patient is respon ...
Full textCite
ConferenceMedical Physics · January 1, 2013
Purpose: We have previously shown that adaptive lung SBRT planning can mitigate dose to adjacent organs at risk (OARs). The aim of this study is to investigate factors that affect dosimetric effectiveness of adaptive lung SBRT, so that we may predict which ...
Full textCite
ConferenceMedical Physics · January 1, 2013
Purpose: To evaluate deformable image registration for the lungs using hyperpolarized gas MR tagging technique.Method and Materials: A 3D MR grid‐tagging technique using hyperpolarized helium‐3 (HP‐He3) as gaseous contrast was developed for direct measurem ...
Full textCite
ConferenceMedical Physics · January 1, 2013
Purpose: To investigate feasibility of motion tracking using concurrent orthogonal kV and MV x‐ray images acquired during dose delivery for stereotactic body radiotherapy (SBRT).Method and Materials: The study was performed on a Varian TrueBeam treatment u ...
Full textCite
ConferenceMedical Physics · January 1, 2013
Purpose: Pre‐operative stereotactic body radiosurgery (SBRT) was delivered in a single fraction to treat patients with early stage breast cancer; however, few data are available regarding radiation‐induced changes by SBRT. In this work, diffusion weighted ...
Full textCite
ConferenceMedical Physics · January 1, 2013
Purpose: To evaluate the quality of organs‐at‐risk (OARs) dose sparing in IMRT plans for anorectal and prostate cancer cases utilizing organ‐based knowledge models to predict OAR DVHs.MethodsThe quality of OAR dose sparing in IMRT plans are evaluated by or ...
Full textCite
ConferenceMedical Physics · January 1, 2013
Purpose: To evaluate the dosimetric quality of an automatic IMRT planning method for Head and Neck (HN) cancer cases. Methods: Eighteen HN cancer patients are planned with nine equally spaced IMRT beams. The OAR dose sparing objectives for each plan (prima ...
Full textCite
ConferenceMedical Physics · January 1, 2013
Purpose: To evaluate the dosimetric quality of an automatic volumetric‐modulated arc therapy (VMAT) planning method for Head and Neck (HN) cancer cases. Methods: Eighteen HN cancer cases are planned automatically by 2‐arc VMAT. An OAR DVH prediction model ...
Full textCite
ConferenceMedical Physics · January 1, 2013
Purpose: Electron beam therapy is under‐utilized in radiation treatment of cancer and has remained practically unchanged for decades. We propose a new technique, Dynamic Electron Arc Radiotherapy (DEAR) with synchronized couch motion. DEAR utilizes modulat ...
Full textCite
ConferenceMedical Physics · January 1, 2013
Purpose: To meet the needs of fast registration of on‐board digital tomosynthesis (DTS), a platform was developed in assisting the task of intensive DTS reconstruction and analysis. Methods: this platform consists of four parts: pre‐processing, reconstruct ...
Full textCite
ConferenceJ Phys Conf Ser · 2013
Six base of skull IMRT treatment plans were delivered to 3D dosimeters within the RPC Head and Neck Phantom for QA verification. Isotropic 2mm 3D data was obtained using the DLOS-PRESAGE system and compared to an Eclipse (Varian) treatment plan. Normalized ...
Full textLink to itemCite
ConferenceMed Phys · June 2012
PURPOSE: To evaluate the dosimetric benefits of online image guidance during prostate stereotactic body radiotherapy (SBRT) and the potential on margin reduction. METHODS: 28 prostate SBRT patients were retrospectively studied, each treated with 37Gy in 5 ...
Full textLink to itemCite
ConferenceMed Phys · June 2012
PURPOSE: We present an evidence-based approach to quantifying the dose sparing trade-offs between different Organs-at-risk (OARs) and the trade-off between OAR dose sparing and target dose coverage in IMRT plans. METHODS: The interaction between dose spari ...
Full textLink to itemCite
ConferenceMed Phys · June 2012
PURPOSE: To develop a predictive model to assess the quality of critical organ dose sparing in IMRT plans by providing patient specific dose sparing references, based on an array of patient anatomical features and prior planning experience. METHODS: Contri ...
Full textLink to itemCite
ConferenceMedical Physics · January 1, 2012
Purpose: Dual‐source CBCT may provide several advantages over current on‐board 3D localization techniques; however, dual‐source CBCT suffers greatly from cross‐scatter. A novel technique was developed that includes sampling the cross‐scatter only projectio ...
Full textCite
ConferenceMedical Physics · January 1, 2012
Purpose: To achieve on‐board molecular imaging in the radiation therapy room, we are developing a robotic multi‐pinhole SPECT system. Alignment of the SPECT system to LINAC/CBCT coordinates is essential for target localization and image reconstruction. Pin ...
Full textCite
ConferenceMedical Physics · January 1, 2012
Purpose: Radiation therapy beam guidance and modulation at treatment time could be substantially supported by onboard molecular and functional imaging capability. Currently there is very little range of technology available for this. Herein we propose and ...
Full textCite
ConferenceMedical Physics · January 1, 2012
Informatics in radiation therapy is less understood. Decision support for, or knowledge‐guided, radiation therapy, is a major component of informatics, where the data is mined, modeled and turned into computable knowledge. It is critically important for ra ...
Full textCite
ConferenceMedical Physics · January 1, 2012
Purpose: To use an anthropomorphic spine phantom for dosimetric credentialing purposes in National Cancer Institute sponsored clinical trials. Methods: An anthropomorphic spine phantom that consists of lungs, a heart, an esophagus, a spinal cord, vertebrae ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Volumetric modulated arc therapy (VMAT) is an arc‐based dose delivery approach that produces highly conformal dose distributions similar to those generated with static gantry intensity modulated radiation therapy. Like many existing IMRT approaches, this t ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Two‐dimensional (2D) detector arrays for QA of volumetric‐modulated‐arc‐therapy (VMAT) plans show angular dependence. An angular correction‐factor‐table (CFs) minimize this effect, but assumes: (1) the response of all ion chambers (IC) is identica ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: A dual detector cone‐beam CT (CBCT) system could potentially allow for dual energy CBCT and dual‐view DTS. However, image quality in this system is severely degraded by the presence of scatter between the two imaging chains, i.e. cross‐scatter. Th ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Very little information is available for noise properties using a dual‐detector cone‐beam CT (CBCT) system. Geometric misalignment, cross‐scatter, and inhomogeneous detector response are additional concerns in a dual‐detector system. This study ch ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Single photon emission computed tomography (SPECT) is being investigated for imaging inside radiation therapy (RT) treatment rooms to target tumor biology. Because of the space occupied by RT devices and the size and weight of typical gamma camera ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Respiratory signal for 4DCT is typically extracted using an external respiratory positioning management device (RPM) which is often inconvenient and time consuming. The efficiency of 4DCT imaging could be substantially improved if anatomical body ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: To develop a total‐variation (TV) based compressive sensing image reconstruction algorithm using a set of limited‐angle projections by applying a prior image information to enhance the image quality and anatomic information of current Four‐d ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Four‐dimensional computed tomography (4D‐CT) has been widely used in radiation therapy for imaging moving tumors, especially in the thoracic regions. In other body sites such as the abdominal, 4D‐CT is limited due to its intrinsic low soft‐tissue contrast. ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: To investigate the reproducibility of probability distribution function (PDF) of lung tumor motion using cine‐MV images from lung SBRT treatments. Findings of the study will provide valuable information for probability‐based treatment planning. Me ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: To investigate accuracy of motion tracking and radiation delivery controlling of integrated gating systems on a Novalis Tx system. Methods: The study was performed on a Novalis Tx system, which is equipped with Varian RPM and BrainLAB ExacTrac gat ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Four‐dimensional (4D) imaging in the radiotherapy treatment room can provide verification of moving targets, which allows for potential reduction of margins and consequent dose escalation. 4D‐CBCT acquisition requires correlation between projectio ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: The aim of this work is to investigate the feasibility of accelerating phase contrast MR angiography by the fast imaging method of Simplified Skipped Phase Encoding and Edge Deghosting with Array Coil Enhancement (S‐SPEED‐ACE). Methods: The parall ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Presently, there is no patient specific dosimetric QA for radiation treatment of moving targets. Here we present a patient specific QA protocol for verification of 4D dosimetry delivered to a moving target in SBRT of lung and liver tumors. Methods ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: To evaluate the dosimetric accuracy of a novel CBCT estimation method using prior information for use in adaptive radiotherapy (ART)‐based treatment of lung cancer patients. Methods: Patient planning CT or previous day's CBCT images are used as th ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: To find the most robust strategies of objective setting and starting stage for online plan re‐optimization, so it can be automatically executed within 1 min while providing high quality adaptive plans. Methods: 10 prostate cancer patients, each wi ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: To develop a fast‐monotonic descent (FMD) algorithm for optimization of VMAT treatment planning, and investigate the impacts of arc numbers and beam interval on the plan dose quality. Methods: Fast‐monotonic descent (FMD) algorithm, proved to be o ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: To identify the key factors of patient anatomy that influence the optimal dose volume histograms (DVHs) for the organs‐at‐risk (OARs) and to explore the tradeoffs between different OAR sparing goals. Methods: 88 prostate IMRT plans were studied re ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: To summarize the knowledge of the dependence of organ‐at‐risk (OAR) dose‐volume distribution on patient's anatomy by machine learning techniques from a database of previous expert plans. Methods: 35 head‐and‐ neck IMRT plans were studied retrospec ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To propose a novel method of acquiring Maximum Intensity Projection (MIP) images using multi‐slice cine MRI, termed as MRI‐MIP, and to evaluate its feasibility in quantifying motion magnitude. Materials and Methods: MRI‐MIP images are acquired usi ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: A 15–30s Breath Hold (BH) is often used in radiation therapy for breast cancer patients to minimize heart dose, however its effect on tumor oxygenation and radiosensitivity is unknown. The purpose of this study is to utilize published data on the ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: Large dark and bright crescents are commonly seen in cone‐beam (CB) CT images acquired onboard radiation therapy machines. The purpose of this project is to develop a technique for removing this artifact. Method and Materials: We propose that cres ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: Very little information is available for clinical CBCT imaging using a dual‐detector system. This study assesses the performance of a recently developed bench‐top dual large‐flat‐panel detectors cone beam computed tomography (CBCT) system and to c ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: A dual‐source CBCT imaging system provides an efficient means to perform 3D and 4D imaging, but the addition of the second imaging chain produces additional scattered photons or cross scatter. The purpose of this study is to characterize cross sca ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To compare the dosimetric results and treatment efficiency of intensity modulated arc therapy using RapidArc™ to static‐gantry IMRT plans for conventional fractionation treatment of head‐and‐neck cancer. Materials and Methods: This study evaluated ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Objectives: Intensity modulated arc therapy (IMAT) can potentially be a useful technique for the treatment of multi‐focal intracranial stereotactic radiosurgery (SRS) with a single isocenter setup. This study compares the effects of coplanar and non‐coplan ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To devlope a reliable and economic phantom for motion management study and investigate its feasibility in evaluating dynamic MRI. Method and Materials: Experiments was performed using an in‐house developed phantom that consists of a platform, a lo ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To develop a self‐sorting four‐dimensional CT (4D‐CT) technique that uses body volume as the respiratory surrogate. Method and Materials: Respiratory signals are determined by the changes in body volume at each slice location as a function of imag ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: Considerable imaging dose to health tissue of patient from 4D‐CT is often a concern. This study is to develop a four‐dimensional magnetic resonance imaging (4D‐MRI) technique based on retrospective sorting strategy that uses body volume as respira ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: One challenge of on‐line image‐guided radiation therapy is requirement of immediate availability of reconstructed 3D or 4D images for evaluation. This study is to develop a highly data‐parallel version and platform of accelerating reconstruction f ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Objectives: Cone beam CT (CBCT) opens the era of three dimensional (3D) imaging guided stereotactic radiosurgery (SRS). The CBCT isocenter accuracy is critical for imaging guided SRS guidance. This study analyzes the daily quality assurance (QA) results of ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: Non‐contrast‐enhanced MR angigraphy (MRA) has always been a valuable clinical tool to study vasculatural diseases. The recently arising concerns of constrast agents in contrast‐enhanced MRA encouraged more use of non‐contrast‐enhanced MRA. The aim ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: Gantry‐angle dependence of dose measurement for intensity‐modulated arc therapy (IMAT) quality assurance (QA) using a two‐dimensional ion chamber array may be significant. A new device, the gantry angle sensor, has been provided to compensate for ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To explore similarities between intensity modulated radiotherapy (IMRT) and intensity modulated arc therapy (IMAT) techniques in the context of the number of multi‐leaf collimator (MLC) segments required to achieve plan objectives, the major facto ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: The anisotropic analytical algorithm (AAA) has been shown to provide more accurate dose calculation due to 3D scatter and inhomogeneity corrections than the pencil beam convolution algorithm (PBC) for inhomogeneous anatomical regions such as lung ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: Developing a protocol to accomplish small animal radiosurgery study conducted at our clinic in evaluating radiation‐induced erectile dysfunction. Method and Materials: Animals were sedated and scanned using commercial CT scanner. Scans were import ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: The answer depends on both the dosimeter's energy response and energy spectrum at distance (point of measurement) from the source. The latter is object of this study. Method and Materials: The spectra in water were calculated with Monte Carlo code ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To characterize the cone‐beam CTDI (CBCTDI) and cone‐beam dose length product (CBDLP) by Monte Carlo (MC) technique. Method and Materials: An extended CT head phantom (60cm long) and an extended CT body phantom (90cm long) were created in our BEAM ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To assess imaging dose of partial and full‐angle CBCT scan protocols, and to evaluate their image quality. Method and Materials: The CTDI of the six new CBCT protocols for Varian OBI were obtained by ion chamber (IC) measurements and Monte Carlo ( ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: The challenge for implementing promising Arc Modulated Radiation Therapy (AMRT) is its effectiveness of treatment planning tools to find optimal multileaf collimator (MLC) sequence and the fluence map. This study provides a new approach to the abo ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: The large fractional dose of hypo‐fractionated prostate treatment requires high accuracy of daily treatment delivery. This study analyzes the performance of an adaptive IGRT (AIGRT) technique, which combines image guidance and adaptive re‐planning ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To monitor the quality of adaptive IMRT plans, especially dose sparing for the organs‐at‐risk (OARs), a plan evaluation tool is developed to predict the dose volume histogram (DVH) based on patient's anatomical information and a database of high q ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: Substantial efforts have been made in recent years to develop on‐board four‐dimensional (4D) imaging techniques using gantry mounted cone‐beam imaging devices. This study validates a slow gantry rotation 4D imaging protocol using lung patient data ...
Full textCite
ConferenceMedical Physics · January 1, 2010
In‐room kilovoltage (kV) x‐ray imaging refers to radiographic imaging using kV x‐ray sources in the radiation treatment room. It has been widely accepted for radiotherapy target localization and treatment intervention. Task Group 104 (TG 104) reports on th ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: An internal target volume (ITV) is often identified by acquiring a free‐breathing cone‐beam computed tomography scan (FB‐CBCT) to verify patient setup of tumors affected by respiratory motion. However, its accuracy is not well understood. The purp ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: Binary outcomes (toxicity=1, no‐toxicity=0) are frequently used as inputs to fit parametric models. However, in reality, outcomes span the range in‐between these extremes; binary values are used for lack of more precise quantification. We propose ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Commissioning an IMRT system refers to the initial verification by phantom studies that treatments can be planned, prepared, and delivered with sufficient accuracy. Our profession has struggled since the inception of IMRT to define what measurements to mak ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To present QA measurements over extended periods at our institute and recommend a QA program for image‐guided radiosurgery on Novalis Tx system. Method and Materials: Novalis Tx system is developed based on a Trilogy linear accelerator featuring B ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To assess errors in a simple visual alignment of a dual large‐flat‐panel, cone‐beam‐CT (CBCT) system, and to obtain misalignment parameters that can be incorporated into image reconstruction for accurate target localization in image‐guided radiati ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To investigate limited‐angle imaging using orthogonal x‐ray systems, with regard to use for target positioning onboard external beam radiation therapy (EBRT) machines. Method and Materials: Image reconstruction was performed using projection data ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To examine the impact of cross scatter on contrast‐to‐noise ratio (CNR) in fluoroscopic images acquired with a dual flat‐panel x‐ray imaging system. Method and Materials: An x‐ray imaging system has been developed consisting of two tube/detector p ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: The purpose of this study is to compare RapidArc plans and conventional IMRT plans for head‐and‐neck cancer treatment involving bilateral nodes. Methods and Materials: This study included 10 locally advanced head‐and‐neck cancer patients. The plan ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To investigate localization accuracy for image‐guided frameless stereotactic‐radiosurgery (IG‐SRS) using CBCT 6D image registration and 6D‐couch on Novalis Tx system. Method and Materials: Novalis Tx system is a powerful radiosurgery system featur ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Objectives: To investigate the feasibility of using an intensity modulated arc technique for multi‐focal intracranial stereotactic radiosurgery with a single isocenter setup to significantly decrease the treatment time. Methods: A Novalis Tx linear acceler ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Objectives: To compare localization accuracy using both conventional frame‐based localizers and cone‐beam CT (CBCT) images for stereotactic radiosurgery (SRS). Methods: A SRS geometric phantom was used to verify the localization accuracy based on a SRS loc ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose Volumetric modulated arc therapy (VMAT) is a rotational IMRT modality that combines dose rate modulation with gantry and MLC motion, thereby increasing the complexity of IMRT delivery. Effective implementation of this technology is still quite new ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To develop a patient‐specific quality assurance protocol for RapidArc™ radiotherapy. Method and Materials: Following the commissioning of RapidArc™ treatment delivery, we tested several methods of patient‐specific quality assurance (QA). Ion chamb ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To investigate how a real‐time tracking technique, based on implanted transponders, could be effectively integrated into the current process for image‐guided radiation treatment of prostate cancer. Method and Materials: Current prostate IGRT proce ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: Biological optimization for IMRT planning is typically not clinically utilized, perhaps due to uncertainties associated with normal tissue complication models. Clinically, IMRT planning still relies heavily on dose‐volume constraints. We propose a ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To estimate absorbed doses and effective dose (ED) from cone beam computed tomography (CBCT) with metal oxide semiconductor field effect transistor (MOSFET) detectors in an anthropomorphic phantom, and to estimate the risk of cancer incidence from ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Any deviation between treated and planned volumes for 3‐D conformal therapy, such as IMRT, may cause an adverse clinical outcome. It is therefore critical to minimize all potential deviations using an on‐board (or real‐time) imaging procedure immediately p ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: Cervical spine (C‐spine) lesions are located more centrally than the rest of the spinal column making the c‐spine an ideal target for the RapidArc therapy technique. In this study, we explore the use of RapidArc to treat c‐spine patients and inves ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: Volumetric modulated arc treatment (VMAT) reduces treatment time over static beam intensity modulated treatment (IMRT) by delivering IMRT using arcs. This clinical study evaluates the feasibility of using VMAT for spine stereotactic body radiother ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To develop quality‐assurance (QA) protocols for the Calypso® 4D Localization System including acceptance testing, commissioning, daily QA, monthly QA, and annual QA. Method and Materials: The following acceptance testing/commissioning/QA protocols ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: In prostate IGRT employing hypofractionation, two methods are commonly used: patient re‐positioning and re‐planning. We propose a hybrid IGRT technique in this study. The dosimetric benefits and efficiency improvement of the technique is quantitat ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: The purpose of this report is to compare RapidArc plans and conventional IMRT plans for prostate cancer involving seminal vesicles. Methods and Materials: This study included 10 patients. The planning‐target volume (PTV) contained the prostate and ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To develop a quick and efficient patient‐specific QA procedure for both IMRT and RapidArc using MLC dynalog files. Method and Materials: MLC dynalog files record both planned and actual MLC leaf positions, actual fractional MU and gantry angle. Th ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: It has been shown that cone‐beam computed tomography (CBCT) can be used in dose calculation for treatment planning. This study investigates the HU and dosimetric properties of six CBCT techniques in comparison with conventional CT to determine whi ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: Four‐dimensional digital tomosynthesis (4D‐DTS) was recently introduced as a novel on‐board 4D imaging technique. The purpose of this study is to develop and implement a slow gantry rotation acquisition protocol for 4D‐DTS. A formalism for determi ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Combining the results of methodologically different models (decision fusion) has been shown to yield a fused result that more truthfully represents the underlying phenomenon, compared to the individual models. In this work, we study the effect of ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To predict radiation‐induced cardiac perfusion defects using a fusion model that combines the results of four separate models: feed‐forward neural networks (NNET), self‐organizing maps (SOM), support vector machines (SVM), and multivariate adaptiv ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Single photon emission computed tomography (SPECT) imaging on‐board radiation therapy machines may enhance radiation therapy. Use of a light‐weight, compact detector would be desirable because of maneuverability, yet is challenged by truncation an ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To construct an imaging system that uses the exit radiation from a brachytherapy source during treatment. This system uses a single flat panel detector (FPD) and is capable of tracking the source position in 3D space, with no extra imaging radiati ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: A new type of high‐definition multi‐leaf collimator (HD 120 MLC, Varian Medical Systems) is being introduced into clinical practice to improve the conformality of stereotactic radiation therapy and radiosurgery. Its leaf width at isocenter is 2.5 ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: While the advantage of imaging guidance with cone beam CT (CBCT) guided radiosurgery is obvious, the localization accuracy of CBCT guided radiosurgery still remains a concern. This study utilized a geometric phantom with known target positions to ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: In head‐and‐neck IMRT treatment, doses to targets and critical organs are affected by many factors including patient positioning, weight loss and tumor shrinkage. To ensure therapeutic effectiveness, re‐planning with a new CT is often conducted. H ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: The efficient multiple acquisition method using Skipped Phase Encoding and Edge Deghosting (SPEED) has been successfully demonstrated with a dynamic contrast enhanced (CE) mice tumor study; however, it has not been tested with any human subjects. ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: The IMRT treatment planning optimization process typically follows one, somewhat arbitrary, path, based on the manner in which the planner changes the optimization constraints/weights during planning. Thus, the planner usually never fully understa ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Using an on‐board cone‐beam CT (CBCT) based statistical margin model to determine whether a prostate center‐of‐mass (COM) based translation correction procedure can significantly reduce the CTV‐to‐PTV margin required for prostate patients who were ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To investigate a method to convert the pixel values of DTS images to HU values with reference HU values from CT images. Method and Materials: This study included CT and DTS images of two phantoms (Catphan and a chest phantom) and three patients (p ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purposes: A research platform was developed for target verification using digital tomosynthesis (DTS). To verify its accuracy, a phantom study was conducted and several clinical cases were investigated. Method and Materials: customer‐developed reconstructi ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To assess the impact of scan angles on the visibility of anatomy in on‐board digital tomosynthesis (DTS) images as a means to optimize this technique. Method and Materials: Head and neck cancer patients undergoing intensity‐modulated radiotherapy ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Amplitude and period of respiratory motion vary among patients. For four‐dimensional digital tomosynthesis (4D‐DTS), the frequency of projection acquisition and the phase window must be optimized based on respiratory motion. The purpose of this st ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Digital Tomosynthesis (DTS) is a quasi‐3D imaging technique which reconstructs images from a limited angle of on‐board projections with significantly lower dose and shorter acquisition time than full cone‐beam CT (CBCT). However, DTS images recons ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To develop a new CT reconstruction algorithm based on Total‐Variation (TV) minimization. The new algorithm is specifically designed for limited angle reconstruction to alleviate volume information loss caused by incomplete projections. Method and ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To investigate the feasibility of a novel online IMRT re‐optimization process. This online process can be an integral part to the current prostate IGRT paradigm to augment the existing patient alignment techniques for cases with complex daily orga ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Accurate and reliable post‐prostate implant dosimetric analysis requires optimal identification of the seeds on CT and optimal description of soft tissues on MRI. We present a fast seed localization technique for MRI that is also robust from motio ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: This study proposes a novel on‐line IGRT technique that can modify the original IMRT plan to match with the “anatomy‐of‐the‐day” within few minutes. The performance of this technique is compared with current on‐line IGRT strategies using bone/soft ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: It is critical that image‐guided radiation therapy (IGRT) and adaptive radiation therapy (ART) are performed with clearly defined goals without abusing the technologies. This study illustrates the current integrated system that provides efficient ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To investigate how proton beam energy spreads dosimetrically affect proton plans. Method and Materials: Scanning proton beams were simulated using the Monte Carlo method. A computer program was developed to calculate the weights to produce the SOB ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To assess the absorbed doses in and around lung tumor by performing radiochromic film measurements. Method and Materials: A phantom was made to have a water equivalent central core, a low‐density middle layer and a water equivalent outer layer to ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Breath‐hold respiratory gating is currently being used to improve the quality of radiotherapy, especially for sites subject to internal motion. One technical challenge that exists is patient regulation of respiration. Typically, the radiation ther ...
Full textCite
ConferenceMedical Physics · January 1, 2008
While technology for image guided radiotherapy (IGRT) has advanced dramatically over the past few years, the basic fact remains that the actual treated target remains poorly or not at all visible using most in‐room imaging technologies. As a result, target ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To develop a convenient and effective patient‐specific IMRT quality assurance (QA) procedure utilizing MLC dynalog files. Method and Materials: IMRT plans are delivered with multi‐leaf collimators (MLC). The complexity of MLC motion and patterns m ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To implement and verify a new source type — phase‐space source in helical mode in DOSXYZnrc/EGSnrc Monte Carlo (MC) code. Method and Materials: To implement a new source type — “phase space source in helical mode” in DOSXYZnrc/EGSnrc, we modified ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: Establish a methodology based on digital infrared imaging (DII) to predict skin reaction after breast irradiation using the Skin Radiosensitivity Index (SRI) derived from early skin temperature changes. Method and Materials: Five breast cancer pat ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To demonstrate clinical feasibility of generating digital tomosynthesis (DTS) in a single breath‐hold (BH) period compared to multiple BH periods for CBCT acquisition and to examine on‐board BH‐DTS as an efficient alternative to BH‐CBCT for target ...
Full textCite
ConferenceMedical Physics · January 1, 2007
PURPOSES: There is a growing interest using MRI only for prostate cancer treatment planning. This study is aimed to investigate clinical feasibility of matching 3D planning MRI to on‐board cone‐beam CT (CBCT) images for target localization. Materials and M ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To compare treatment isocenter placement based on OBI 2D kV imaging and OBI 3D‐CBCT imaging for patients undergoing SBRT, and compare the CBCT based isocenter shifts among liver, lung and spine lesions. Material and Methods: 119 SBRT fractions wer ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: Automatic registration between reference and on‐board digital tomosynthesis (DTS) is a critical step for target localization using DTS. We previously developed an approximate method for automatic registration between reference and on‐board DTS, in ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To develop a workstation for clinical application of digital tomosynthesis (DTS) for real‐time target localization. Specifically, to accelerate the reconstruction both digitally‐reconstructed radiograph (DRR) and DTS using ultra‐fast interpolation ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: Single Photon Emission Computed Tomography (SPECT) onboard radiation therapy machines could enable the use of functional and molecular imaging in guiding the therapy beam and in monitoring disease. Costs and spatial constraints of onboard SPECT mi ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: This study is to verify IMRT QA MapCheck measurement using Monte Carlo simulations. Method and Materials: MapCheck (Sun Nuclear) contains 445 silicon diode detectors arranged in a 22×22‐cm2 area, of which 221 are located in the 10×10 cm ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: It is well‐known that fluctuation in chemical compositions can lead to significant errors in the dosimetry of low‐energy brachytherapy sources using the traditional “water‐equivalent” solid phantoms. The aim of this work was to investigate the fea ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: High dose rate (HDR) brachytherapy delivers rapidly a large, highly spatially varying dose. Consequently, precise quality assurance of source location and dwell time is important. Here, we propose that, with no additional radiation exposure to the ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: For external photon beams, the depth dependence of the stopping power ratio between air and water in the buildup region is difficult for accurate quantitative characterization. Qualitatively the depth dependence increases as the photon energy incr ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: MU efficiency is a major figure of merit for dMLC leaf sequencing. However, leaf sequencing is often generated with focus on other constraints and the MU efficiency is taken as a byproduct. This work is to develop a new dMLC leaf sequencing algori ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To develop neural network based models for predicting respiratory induced tumor motion from gating signals and unsorted cine CT images. The ability of the models to predict target motion given real‐time surrogate marker motion was verified using a ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: The impact of organ motion and deformation has been studied for conventional radiation therapy. The cumulative dose is usually a blurred version of the static plan after motion‐induced hot and cold spots average out over a large number of fraction ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To apply on‐boardmdash;image (OBI) guided amplitude gating for breath‐hold treatment and to assess treatment margin adequacy by analyzing the isocenter placement based on orthogonal 2D kV radiographs and 3D cone‐beam CT (CBCT) acquired under ampli ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: This study proposes a novel on‐line adaptive planning technique for the prostate treatment by directly re‐optimizing the IMRT plan based on both the “anatomy‐of‐the‐day” and the original plan information. Method & Materials: Using a commercial tre ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: This clinical study evaluates digital tomosynthesis (DTS) technology for daily imaging guidance for partial breast irradiation (PBI) and compares its positioning accuracy to the 3D CBCT technique. Compared to CBCT, DTS offers lower imaging dose an ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To investigate the clinical feasibility of performing concurrent kilovoltage (kV) x‐ray imaging while the patient at the treatment position was irradiated by megavoltage (MV) beams. Method and Materials: Anatomical visibility and contrast details ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To evaluate the three‐dimensional target localization accuracy using CBCT of an On‐Board Imager (OBI) system by determining the detection error and residual error associated with image registration and patient repositioning. Method and Materials: ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: The conventional application of Fuzzy Inference System (FIS) on parameter optimization of IMRT treatment planning requires that the FIS model (membership function, inference rules) to be predetermined in an intuitive way based on prior planner's k ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To evaluate the dosimetric improvement of IMRT treatment plans generated with patient‐specific margins compared to uniform margins for prostate cancer patients. Methods and Materials: For 13 prostate cancer patients who underwent IMRT treatment, d ...
Full textCite
ConferenceIfmbe Proceedings · January 1, 2007
Purpose: To develop a comprehensive quality assurance (QA) program for the On-Board Imager (OBI) used for patient positioning verification and to present the results of QA tests over extended periods from multiple institutions. Radiographic and cone-beam c ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: Develop a model that augments the dose‐based parametric Lyman NTCP formulation using non‐parametric decision trees that can additionally account for the influence of non‐dose variables. Apply and test the model to predict Grade 2+ lung radiotherap ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To evaluate radiation dose in kV cone‐beam computed tomography (CBCT) and to benchmark Monte Carlo (MC) simulations in the PMMA CT phantoms Method and Materials: Using an On‐Board Imager (Varian Medical Systems), we measured absorbed doses to the ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: Single photon emission computed tomography (SPECT) provides a spatial distribution map of lung perfusion. Previously, an algorithmic methodology was developed using IMRT and SPECT guidance to deliberately divert dose away from higher functioning ( ...
Full textCite
ConferenceIfmbe Proceedings · January 1, 2007
Purpose: This study investigates feasibility of CBCT-based treatment planning. Methods and materials: Hounsfield unit (HU) values and profiles of phantoms and patients in CBCT images were compared to those in CT images. CBCT-based treatment plans for the p ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Objective: The true dose distribution is subject to change due to organ shifts and also deformations. The goal of this work is to estimate the effect of the elastic organ deformations on the dose distribution for the average prostate IMRT treatment. Method ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: This project presents an analysis of the point spread function (PSF) of isocentric digital tomosynthesis (DTS). DTS is a limited angle 3‐ dimensional reconstruction from cone beam projections, with high resolution for excellent imaging of both bon ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To study the impact of projection numbers on the quality of tomosynthesis images using megavoltage beams. Method and Materials: It has been shown that isocentric kilovoltage tomosynthesis images can be generated with no more than 50 degree scan an ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Since radiotherapy treatments only utilize a limited number of beams, it is important that these beams be carefully selected to extract maximum benefit. Here we propose a novel, fast, scheme that selects beam number and orientations for IMRT with ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To evaluate the dosimetric consequence of 3D positioning verification for prostate IMRT treatment using CBCT. Method and Materials: Patients in this study were repositioned using 2D orthogonal radiographic images, taken prior to treatment to match ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Digital tomosynthesis (DTS) is a fast, low‐dose method for reconstructing 3‐D slices from 2‐D cone‐beam x‐ray projection data acquired with limited source angulation (e.g., 40°). We previously developed a method for reconstructing reference DTS (R ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To study the effect of imaging orientations on image quality of aggregated conebeam CT and to develop a strategy to minimize scatter artifact. Method and Materials: Orthogonal kilovoltage (kV) and megavoltage (MV) beam projections were acquired an ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Accelerated partial‐breast irradiation (APBI) is an emerging radiation technique that challenges standard whole breast irradiation. The larger fraction sizes used in these hypofractionated schedules may increase the risk of late normal tissue effe ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To develop and assess a technique using cone‐beam CT (CBCT) to localize treatment targets for stereotactic body radiation therapy (SBRT). Material and Methods: Patients selected for SBRT had 3‐D or 4‐D CT simulation with immobilization. GTV, CTV, ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To assess the accuracy and practicality of using GAFCHROMIC® EBT Film in combination with an Epson flat‐bed scanner for the verification of advanced treatment techniques in radiation therapy. EBT is a new type of Gafchromic film with high sensitiv ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Digital tomosynthesis (DTS) is a method for reconstructing 3D images from cone‐beam projection data acquired with limited angulation (e.g., 40°) of an x‐ray source, and is much faster and lower dose than full cone‐beam CT (CBCT). We previously dev ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Functional and molecular (F&M) imaging onboard radiation therapy machines would allow for targeting of functional tumor volume, and avoiding of healthy tissue, by guiding and modifying radiation beams, in the treatment room, based on real‐time F&M ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To demonstrate the concept of 2D projection and 3D volumetric imaging using brachytherapy treatment sources in patient prior to or during treatment. Method and Materials: As shown Figure 1, an Ir‐192 HDR catheter is placed at 15 cm depth (a reason ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To systematically evaluate the electron Monte Carlo (eMC) dose calculation algorithm of the Eclipse treatment planning system and to identify factors that affect its calculation accuracy. Method and Materials: Percent depth dose (PDD) and profiles ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To demonstrate the conservation rule of the integrated reference air kerma (IRAK). Method and Materials: For a brachytherapy photon source whose radial dose functions is flat over the clinical distance range, the dose falls off with the inverse sq ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: A novel imaging based model is proposed to describe the stochastic nature of the shape and location of a volume of interest (VOI). Based on the VOIs in sequential patient images, the model can predict the probability that a specific point will bel ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Partial breast irradiation with multiple external beams requires accurate alignment of the target volume and treatment isocenter. On‐board plannar kV/MV imaging can verify set‐up based on boney landmarks. On‐board cone beam CT (CBCT) may provide a ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: The internal target volume (ITV) could be determined using 4D CT simulation images and be verified in the treatment room using on‐board cone‐beam CT (CBCT) since the CBCT projection images are acquired over approximately 10 breathing cycles. This ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Respiratory gating systems have been developed to reduce treatment uncertainty caused by organ motions related to respiration. The time‐delay between when the gating signal is triggered and when the beam is turned on may affect the actual radiatio ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: We have applied OBI guidance together with a respiratory gating system to effectively control patient positioning for amplitude gating treatment with breath hold. The deep inspiration breath‐hold treatment has been proven effective in reducing the ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Daily target localization is a critical step to secure accurate delivery for 3‐D conformal radiation therapy and intensity‐modulated radiation therapy. One emerging technology using in‐room kilovoltage (kV) imaging has shown to be very promising for target ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To implement a clinical tool for off‐line review of Cone‐Beam Computed Tomography (CBCT) based 3D target verification and localization. Methods and Materials: An in‐house 3D target localization and verification tool is being developed to allow phy ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To develop a method to reconstruct CBCT data based on projection data acquired at a specific respiration phase. Methods and Materials: The original projection data were acquired using an on‐board imager (OBI) (Varian Medical Systems) over scanning ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To evaluate the effectiveness of a Fuzzy Logic guided parameter optimization method for inverse treatment planning, in comparison with the results achieved by routine trial‐and‐error method. Method and Materials: The optimization algorithm was dev ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To develop a method for modeling the dynamic relationship between patient surface motion and internal target motion using 4DCT data. Then, to verify its capability to interpolate internal target motion with real‐time patient surface motion informa ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To develop a comprehensive quality assurance (QA) program for the On‐Board Imager (OBI) used for patient positioning verification and to present the results of QA tests over extended periods from multiple institutions. Radiographic and cone‐beam c ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Single photon emission computed tomography (SPECT) provides a map of the spatial distribution of lung perfusion. Thus, SPECT guidance can be used to deliberately divert dose away from higher functioning lung, thereby potentially reducing lung toxi ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To investigate the feasibility of cone‐beam computed tomography (CBCT)‐based treatment planning. Methods: HU of material disks in Catphan, HU profiles for homogeneous and inhomogeneous phantoms, and HU values in different tissue areas of brain, th ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: To develop a respiratory gated radiation therapy (RGRT) technique by directly matching the patient's anatomical structures acquired during the imaging cycles to that in a reference image. Method and Materials: Studies showed that the external mark ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: To quantify the degree of normal organ motion due to the respiratory and cardiac cycles. Better definition of such motion may be useful in defining field margins and in assessing the utility of gating technologies. Method and Materials: Four healt ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: This study introduces a new radiation therapy target localization technique using online digital tomosynthesis (DTS), a method for reconstructing 3‐D slices from 2‐D projection data acquired with limited source motion. By separating the visualizat ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: Copper labeled diacetyl‐bis(N4‐methylthiosemicarbazone) (Cu‐ATSM) has been reported to selectively bind to hypoxic tumor cells. This makes Cu‐ATSM PET a promising modality to image tumor hypoxia. However, intravascular Cu‐ATSM that is not related ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: It has been noted that dosimetric difference due to tissue inhomogeneity is significant for a lung patient. If there is no tissue inhomogeneity correction (IC) made, the treatment plan could mislead treatment. Commercial radiation treatment planni ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: The newly installed OBI system consists of a kilo‐voltage (KV) X‐ray source and a flat‐ panel detector mounted orthogonally to the megavoltage portal imager (MV) in Varian 21EX machine. These devices are linked to the OBI workstation which provide ...
Full textCite
ConferenceProceedings of SPIE the International Society for Optical Engineering · May 12, 1995
A fully automated system is being developed for the portal verification of tangential breast fields in radiation therapy of breast cancer. The automated verification system involves image acquisition, image feature extraction, feature correlation between r ...
Full textCite
ConferenceProceedings of SPIE the International Society for Optical Engineering · July 29, 1993
We are developing an "intelligent" workstation to assist radiologists in diagnosing breast cancer from mammograms. The hardware for the workstation will consist of a film digitizer, a high speed computer, a large volume storage device, a film printer, and ...
Full textCite
ConferenceConference Proceedings IEEE International Conference on Systems Man and Cybernetics · January 1, 1992
We are developing computer-aided diagnosis schemes for the detection of breast lesions in digital mammograms. The detection scheme employs a bilateral-subtraction technique that is based on the normal symmetry between the left and right breast images. The ...
Full textCite