A Novel Methodology for Automated Image Quality Assessment of Pediatric CT

Conference · November 25, 2018 PURPOSE To develop an effective and automated methodology for patient-specific image quality assessment of clinical pediatric body CT examinations. METHOD AND MATERIALS This IRB approved study evaluated 816 clinically performed (6/14-11/17), contrast-enh ... Cite

Beyond the DRL: Applying Automated Quality Metrics to Assess Pediatric CT Program Liver Lesion Detection Performance

Conference · November 25, 2018 PURPOSE To apply an automated program for evaluating pediatric body CT study quality which utilizes metrics of dose and image quality for optimization of liver lesion detection. METHOD AND MATERIALS With IRB approval, 880 clinical contrast-enhanced abdom ... Cite

From DRL to NRL: A First Step Toward Quality-Based Reference Level

Conference Medical Physics · June 30, 2017 Purpose: Radiologic procedures are optimized based on a benefit-to-risk. However, risk has been the primary focus of radiology optimization and dose monitoring. Such programs are typically based on the concept of Diagnostic Reference Level (DRL). The term ... Cite

Simulation of anatomical texture in voxelized XCAT phantoms

Conference Progress in Biomedical Optics and Imaging Proceedings of SPIE · June 3, 2013 While great advances are made toward making highly realistic, surface models of the human anatomy, very little has been done to fill these bounded surfaces with models of anatomical texture. We propose a method whereby realistic anatomically-based computed ... Full text Cite

TU‐C‐103‐07: Prospective Estimation of Diagnostic Performance and Radiation Dose for Individual CT Scans

Conference Medical Physics · January 1, 2013 Purpose: Te prespectively determine size‐and task‐based image quality indices and te quantify the relatienship between image quality and radiatien dese as a patient‐specific basis fer abdeminepelvic CT scans. Methods: Medel ebserver metric ef detectability ... Full text Cite

SU‐D‐103‐06: Bismuth Shield Usage in MDCT Thoracic Scans: Organ Dose Vs. Image Quality

Conference Medical Physics · January 1, 2013 Purpose: To study Bismuth (Bi) shielding for the breast, organ dose and image quality were compared under the following conditions: (1) tube current modulation (TCM), (2) TCM with a Bi shield placed after topogram, and (3) manually reduced tube current (RT ... Full text Cite

TH‐A‐214‐03: Automated Patient‐Specific CT Dose Monitoring System: Assessing Variability in CT Dose

Conference Medical Physics · January 1, 2011 Purpose: To develop an automated patient‐specific radiation dose monitoring system for CT capable of assessing variability in CT dose delivered to individual patients. Methods: CT image data were sent from PACS to a secure dosimetry server. The dose report ... Full text Cite

SU‐E‐I‐24: Pediatric CT Effective Dose ‐ A Comparison Between the MOSFET Method and the DLP Method

Conference Medical Physics · January 1, 2011 Purpose: The effective doses (ED) were compared between the MOSFET method and the DLP method for a variety of clinical CT scans. Methods: Two CT scanners (Manufacturer A and B) were used in this study. Organ doses were measured with MOSFET detectors. Twent ... Full text Cite

Patient-specific radiation dose and cancer risk estimation in pediatric chest CT: A study in 30 patients

Conference Progress in Biomedical Optics and Imaging Proceedings of SPIE · December 1, 2010 Radiation-dose awareness and optimization in CT can greatly benefit from a dose- reporting system that provides radiation dose and cancer risk estimates specific to each patient and each CT examination. Recently, we reported a method for estimating patient ... Full text Cite

Pediatric Head Contours and Inertial Properties for ATD Design

Conference SAE Technical Papers · November 3, 2010 Child head trauma in the United States is responsible for 30% of all childhood injury deaths with costs estimated at $10 billion per year. The common tools for studying this problem are the child anthropomorphic test devices (ATDs). The headform sizes and ... Full text Cite

MO‐E‐204B‐05: A Novel Organ Dosimetry in an Anthropomorphic Phantom Using XRQA‐2 Radiochromic Film

Conference Medical Physics · January 1, 2010 Purpose: A novel method to measure organ dose distributions in a phantom of heterogeneous tissue composition was established using radiochromic XRQA‐2 films. Film response accuracy was validated using thermoluminescent dosimeters (TLDs). Method and Materia ... Full text Cite

SU‐GG‐I‐56: Testes and Uterine Dose Measurements from Scout View in Lumbar Puncture Procedure and Regular Pelvic CT Scan

Conference Medical Physics · January 1, 2010 Purpose: The purpose of this study was to measure the dose to testes and uterus from the scout views of lumbar puncture procedure and during a routine pelvic CT scan. Materials and methods: Five high sensitivity MOSFETs (TN‐1002RD, Best Medical, Canada) we ... Full text Cite

SU‐FF‐I‐56: Radiation Dose Estimation From Pediatric Cone Beam Computed Tomography

Conference Medical Physics · January 1, 2009 Purpose: To estimate absorbed doses and effective dose (ED) from cone beam computed tomography (CBCT) with metal oxide semiconductor field effect transistor (MOSFET) detectors in an anthropomorphic phantom, and to estimate the risk of cancer incidence from ... Full text Cite

TU‐C‐304A‐05: Dose Reductions of Bismuth Shields in Diagnostic Radiology: Measurements and Monte Carlo Simulations

Conference Medical Physics · January 1, 2009 Purpose: To assess the dosimetric characteristics of bismuth breast shields for a CT beam with ion chamber measurements and Monte Carlo simulations. Method and Materials: Primary attenuation and backscatter effects of both adult and pediatric bismuth super ... Full text Cite

SU‐FF‐I‐28: Evaluation of a Noise Addition Software for Simulating Low Dose MDCT Images

Conference Medical Physics · January 1, 2007 Purpose: To evaluate the utility of a noise addition software in simulating realistic MDCT images at reduced radiation dose levels. Methods and Materials: The utility of the software in simulating realistic low dose CT images was evaluated using a water ph ... Full text Cite