Journal articlePediatr Radiol · September 2013
Featured Publication
BACKGROUND: Advanced multidetector CT systems facilitate volumetric image acquisition, which offers theoretic dose savings over helical acquisition with shorter scan times. OBJECTIVE: Compare effective dose (ED), scan duration and image noise using 320- an ...
Full textLink to itemCite
Journal articleAcad Radiol · September 2013
Featured Publication
RATIONALE AND OBJECTIVES: Efforts to decrease radiation exposure during pediatric high-resolution thoracic computed tomography (HRCT), while maintaining diagnostic image quality, are imperative. The objective of this investigation was to compare organ dose ...
Full textLink to itemCite
Journal articleRadiology · July 2013
Featured Publication
PURPOSE: To develop diagnostic reference ranges (DRRs) and a method for an individual practice to calculate site-specific reference doses for computed tomographic (CT) scans of the abdomen or abdomen and pelvis in children on the basis of body width (BW). ...
Full textLink to itemCite
Journal articleJ Am Coll Radiol · May 2013
Featured Publication
PURPOSE: Diagnostic imaging, including ionizing radiation modalities, maintains a prominent role in the medical evaluation of patients. There is increasing awareness and need for information across varied sectors about low-level radiation and potential ris ...
Full textLink to itemCite
Journal articleMed Phys · April 2013
Featured Publication
PURPOSE: The authors previously developed the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. The XCAT consisted of highly detailed whole-body models for the standard male and female adult, including the cardiac and respiratory ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · November 2012
Featured Publication
OBJECTIVE: The purpose of this study is to determine patient dose estimates for clinical pediatric cardiac-gated CT angiography (CTA) protocols on a 320-MDCT volume scanner. MATERIALS AND METHODS: Organ doses were measured using 20 metal oxide semiconducto ...
Full textLink to itemCite
Journal articleMed Phys · November 2012
Featured Publication
PURPOSE: In computed tomography (CT), organ dose, effective dose, and risk index can be estimated from volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) using conversion coefficients. Studies have investigated how these coefficients va ...
Full textLink to itemCite
Journal articleMed Phys · November 2012
Featured Publication
PURPOSE: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising th ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · July 2012
Featured Publication
OBJECTIVE: The purpose of this study was to assess the radiation dose distribution and image quality for organ-based dose modulation during adult thoracic MDCT. MATERIALS AND METHODS: Organ doses were measured using an anthropomorphic adult female phantom ...
Full textLink to itemCite
Journal articleForensic Sci Int · January 10, 2012
Featured Publication
Radiologic imaging is crucial in the diagnosis of skull fracture, but there is some doubt as to whether different imaging modalities can accurately identify fractures present on a human skull. While studies have been performed to evaluate the efficacy of r ...
Full textLink to itemCite
Journal articlePediatr Radiol · January 2012
Featured Publication
BACKGROUND: Diagnostic imaging plays an integral role in diagnosing and managing many pediatric disorders, but there is growing concern in both the medical community and the general public about the long-term health effects of ionizing radiation in childre ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · October 2011
Featured Publication
OBJECTIVE: Diagnostic imaging performed during pregnancy, particularly if it involves the use of ionizing radiation, can be a source of great anxiety for both health care providers and patients. Especially with the growing public awareness of the increasin ...
Full textLink to itemCite
Journal articlePediatr Radiol · September 2011
Featured Publication
Significant progress has been made in radiation protection for children during the last 10 years. This includes increased awareness of the need for radiation protection for pediatric patients with international partnerships through the Alliance for Radiati ...
Full textLink to itemCite
Journal articlePediatr Radiol · September 2011
Featured Publication
It has been 10 years since the original pediatric CT ALARA conference in 2001, so it is fitting that we look back at our progress. The following material will look at how we might quantify our performance regarding the justification and optimization of rad ...
Full textLink to itemCite
Journal articlePediatr Radiol · September 2011
Featured Publication
Pediatric CT radiation dose and risk assessment are important but challenging, especially given inherent uncertainties. It is still necessary for those involved in medical imaging of children to have an understanding of the extent of existing knowledge for ...
Full textLink to itemCite
Journal articleRadiat Prot Dosimetry · September 2011
Featured Publication
The Radiation Protection in Medicine conference, reviewed in this journal supplement, outlined nine strategies to promote radiation protection for patients. The Alliance for Radiation Safety in Pediatric Imaging has focused its work on three of those areas ...
Full textLink to itemCite
Journal articleJ Urol · March 2011
Featured Publication
PURPOSE: Low dose noncontrast computerized tomography is becoming a common imaging tool to diagnose urolithiasis. We investigated its usefulness as a diagnostic tool in the outpatient setting. MATERIALS AND METHODS: A total of 62 patients with suspected ur ...
Full textLink to itemCite
Journal articleRadiology · March 2011
Featured Publication
This special report aims to inform the medical community about the many challenges involved in managing radiation exposure in a way that maximizes the benefit-risk ratio. The report discusses the state of current knowledge and key questions in regard to so ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · November 2002
Featured Publication
OBJECTIVE: Limiting CT radiation dose is especially critical when imaging children. The purpose of our study was to modify and test an accurate and safe tool for evaluating systematic dose reduction for abdominal multidetector CT (MDCT) in pediatric patien ...
Full textLink to itemCite
Journal articleJ Thorac Imaging · October 2002
Featured Publication
This case report of a possible aortic pseudoaneurysm after coarctectomy in a 12-month-old boy illustrates the unique considerations when performing pediatric cardiovascular CT angiography in young children. With newer (8-channel) multidetector technology, ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · March 2002
Featured Publication
OBJECTIVE: CT technique should be adjusted while scanning infants and children. One format that has proven successful in simplifying pediatric care and reducing medical error is the size-based, color-coded Broselow-Luten pediatric system. This color-coded ...
Full textLink to itemCite
Journal articleJ Pediatr · June 2001
Featured Publication
We report 2 patients with confirmed Niemann-Pick disease, type B, with previous diagnoses of glycogen storage disease based on excessive glycogen on liver biopsy specimens. These cases emphasize the importance of a complete evaluation, including biochemica ...
Full textLink to itemCite
Journal articlePediatr Radiol · May 2001
Featured Publication
BACKGROUND: Bronchopulmonary dysplasia (BPD) continues to be prevalent, despite new treatment, in part because of increased survival in less mature infants. Investigations of new treatments have been hampered by a lack of universally accepted diagnostic cr ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · February 2001
Featured Publication
OBJECTIVE: Our objective was to determine whether adjustments related to patient age are made in the scanning parameters that are determinants of radiation dose for helical CT of pediatric patients. SUBJECTS AND METHODS: This prospective investigation incl ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · February 2001
Featured Publication
Adjustments of the standard helical CT protocols for adults can result in reduced radiation dose when imaging children. It is the radiologist's responsibility to critically evaluate the CT techniques used at their institution. Adjustments to CT protocols s ...
Full textLink to itemCite