ConferenceIEEE International Ultrasonics Symposium Ius · January 1, 2023
Automated, real-time adjustment of ultrasound imaging parameters could speed up scanning sessions, decrease operator dependence, and improve reproducibility. This study examines adaptive frequency and acoustic output adjustment in color Doppler imaging to ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · January 1, 2022
Previous work has demonstrated acoustic output can be adaptively adjusted to follow the ALARA (as low as reasonably achievable) principle. Here, a refined ALARA approach is introduced based on capturing a system's underlying noise power and using it, along ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · January 1, 2022
The impact of temporal noise on ultrasound image quality can be decreased with use of higher acoustic output. Acoustic output increases amplify receive signal strength relative to the temporal noise floor, improving the temporal signal-to-noise ratio (SNR) ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · January 1, 2021
Adaptive acoustic output selection in ultrasound imaging promises to improve adherence to the ALARA (as low as reasonably achievable) principle. Demonstrated imaging sequences have balanced image quality and safety considerations based on transducer channe ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · September 7, 2020
Ultrasonic image quality is often challenged by speckle noise and acoustic clutter which reduces the anatomical conspicuity of medically relevant features. Deep learning approaches show promise in correcting these sources of noise, but there currently lack ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · September 7, 2020
The coherence of signals received by neighboring transducer array elements, the lag-one coherence (LOC), provides a local measure of clutter and temporally varying noise. Increasing transmit intensity decreases the impact of temporal noise on image quality ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · September 7, 2020
Adaptive transmit frequency selection, filtering, and frequency compounding all offer the ability to improve target conspicuity by balancing the effects of imaging resolution, signal-to-clutter ratio, and speckle texture, but the use of pilot pulses at a s ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 1, 2019
Acoustic Radiation Force Impulse (ARFI) images are used to visualize spatial variations in soft tissue elasticity by showing the displacement of each pixel in response to an applied radiation force. However, accommodations for spatial variations in the app ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 1, 2019
Visualization of the endocardial border is essential in determining left ventricular and overall cardiac function. Ultrasound imaging systems typically rely on image post-processing for contrast and detail enhancement. Spatial compounding is a physics-base ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 1, 2019
Image post-processing is used in clinical-grade ultrasound scanners to improve image quality (e.g., reduce speckle noise and enhance contrast). These post-processing techniques vary across manufacturers and are generally kept proprietary, which presents a ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · December 17, 2018
The US Food and Drug Administration (FDA) provides guidelines for acoustic output to ensure that ultrasound remains a safe imaging modality used widely in applications such as obstetrics. However, even within these limits, additional acoustic output that d ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · December 17, 2018
In order for shear wave elastography (SWE)to be a quantitative imaging tool for myocardial stiffness, it is important to eliminate or reduce the non-disease related factors that affect myocardial stiffness estimation. It is known for shear wave speed repre ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · December 17, 2018
Ultrasound imaging is the product of numerous pulse sequence and processing design choices, but it is impossible to optimize for every clinical imaging case with a single set of parameters. Many sonographers do not take advantage of even the limited set of ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · December 17, 2018
Hepatic image quality has been shown to be degraded by the clutter-generating effects of the abdominal wall, and while beamforming and signal processing methods exist to minimize clutter, there is currently no automated method by which parameters such as i ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · January 1, 2018
Fibrous tissues, such as skeletal muscle, tendons, and myocardium, have been shown to support orientation-dependent shear wave propagation. It has been shown that shear waves can be induced and measured with ultrasound to assess such anisotropy. Existing m ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
Poor quality ultrasound images and inadequate or suboptimal visualization of imaging targets is a common problem in individuals that are overweight or obese. Acoustic reverberation is an incoherent noise source that is a common factor in overweight and obe ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
Fetal short-lag spatial coherence (SLSC) imaging has demonstrated 64-85% increases in CNR and 17-29% increases in contrast relative to conventional B-mode imaging. However, despite its proven technical efficacy, the viability of fetal SLSC in the clinical ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
Cardiac function has traditionally been studied using pressure-volume (PV) loop analysis. PV loops can be used to derive functional indices such as end-systolic pressure volume relationship (ESPVR) - a measure of myocardial contractility, end-diastolic pre ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
Myocardial strain imaging has been shown to add significant prognostic and diagnostic value to echocardiography. While the reliability of ultrasound-based strain measurement techniques has improved considerably in terms of regional consistency and inter-re ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
Strain imaging is gaining traction as a means to assess cardiac function by tracking the cyclic deformation of the myocardium. Compared to traditional measures such as ejection fraction, global myocardial strain has been shown to be an earlier and more sen ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
Myocardial elastance, derived from pressure-volume (PV) loops in the left ventricle (LV), can be used to assess LV function and myocardial performance. This method requires an invasive intracardiac pressure-volume catheter to be inserted in the LV, limitin ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
Measurement of myocardial stiffness using ultrasound-based transient elastography has received significant attention in recent years. The mechanical properties of myocardium not only undergo cyclic dynamic changes over the cardiac cycle but also change on ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
Single Track Location Shear Wave Elasticity Imaging (STL-SWEI) creates high resolution shear wave speed maps by comparing the tissue motion at each tracking location between spatially-offset radiation force excitations. While STL-SWEI circumvents the resol ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
ARFI displacements have been shown to share an inverse relationship with shear wave speed - based estimates of tissue elasticity. Both ARFI and shear wave elasticity imaging (SWEI) have been used to track the stiffening and softening of myocardium through ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
Lateral resolution and therefore image quality in ultrasound is tied to aperture size. While this relationship is understood in ideal imaging conditions, the utility of a large aperture in the presence of clutter is unknown. This problem is particularly re ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
ARFI displacements have been shown to share an inverse relationship with shear wave speed - based estimates of tissue elasticity. In transthoracic imaging, induced shear waves have been observed during diastole, but only ARFI displacements have been accura ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 31, 2017
Comb-Push Ultrasound Shear Elastography (CUSE) uses ultrasound beams focused simultaneously at multiple laterally-offset positions to induce shear waves in tissue, and uses the local propagation of the waves to estimate tissue elasticity everywhere in the ...
Full textCite
ConferenceProceedings International Symposium on Biomedical Imaging · June 15, 2017
In the context of ultrasound (US) deformation imaging it has been shown that lateral motion estimation can be improved by simultaneously combining transverse oscillation (TO) beamforming with dedicated motion estimators and regularisation techniques. This ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · November 1, 2016
Shear Wave Elasticity Imaging (SWEI) measures the elastic properties of the liver noninvasively, with application to staging liver fibrosis. To make a useful estimate, a shear wave of sufficient amplitude must be generated in the liver. Tracking speckle si ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · November 1, 2016
Reverberation and aberration clutter can significantly degrade the ability to image deep abdominal structures in clinical practice. Despite increased hardware complexity and computing power, modern ultrasound arrays are still commonly limited to a length o ...
Full textCite
ConferenceProceedings of the IEEE Sensor Array and Multichannel Signal Processing Workshop · September 15, 2016
In this paper, we exploit motion for improving the ultrasound (US) imaging performance of thinned sensor array systems. Thinned arrays provide reduced system cost and allows for the reduction of bulky channel cables. However, thinned array systems suffer f ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2016
When imaging with ultrasound through the chest wall, it is not uncommon for parts of the array to get blocked by ribs, which can limit the acoustic window and significantly impede visualization of the structures of interest. With the development of large-A ...
Full textCite
Conference2015 IEEE International Ultrasonics Symposium Ius 2015 · November 13, 2015
Myocardial elasticity is an important indicator of cardiac function and is affected in many disorders associated with heart failure. Ultrasound based interrogation of cardiac stiffness has been extensively studied in ex-vivo, open chest and intracardiac im ...
Full textCite
Conference2015 IEEE International Ultrasonics Symposium Ius 2015 · November 13, 2015
Ultrasound imaging of deep abdominal targets suffers from low lateral resolution due to limited aperture size and low-frequency transmit pulses. We demonstrate phantom and in vivo imaging results using a device that allows a tracked mechanical sweep of a c ...
Full textCite
Conference2015 IEEE International Ultrasonics Symposium Ius 2015 · November 13, 2015
Echocardiography is widely used to evaluate cardiovascular function in real-time; however, endocardial borders are often inadequately visualized due to clutter. Contrast agents, while effective, increase cost and examination time. SLSC imaging is a coheren ...
Full textCite
Conference2015 IEEE International Ultrasonics Symposium Ius 2015 · November 13, 2015
Conventional multiple track location shear wave elasticity imaging (MTL-SWEI) is a powerful tool for noninvasively estimating tissue elasticity. The resolution and noise of MTL-SWEI systems, however, are limited by ultrasound speckle. Single track location ...
Full textCite
Conference2015 IEEE International Ultrasonics Symposium Ius 2015 · November 13, 2015
In conventional, multiple track location shear wave elasticity imaging (MTL-SWEI), shear wave speeds are estimated by imaging wave propagation at multiple positions in the tissue with high speed ultrasound and comparing the motion measured at each location ...
Full textCite
Conference2015 IEEE International Ultrasonics Symposium Ius 2015 · November 13, 2015
A new referencing scheme for estimating axial displacements with ultrasound is presented. The multiresolution scheme combines estimates made at multiple temporal spacings into a single, noise robust, high resolution estimate. The problem is framed as an ov ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2015
Ultrasound imaging of deep targets is limited by the resolution of current ultrasound systems based on the available aperture size. We propose a system to synthesize an extended effective aperture in order to improve resolution and target detectability at ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2015
Conventional B-mode ultrasound images suffer from clutter composed of reverberation and aberration that exhibit only partial spatial coherence, making it possible to suppress these confounding signals using coherence- based imaging techniques. Coherence is ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2015
Synthetic aperture (SA) is a technique that enhances the image resolution by synthesizing information from multiple subapertures. The application of this technique for medical ultrasound imaging has been an active research area, but the resolution improvem ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 20, 2014
Short-lag spatial coherence (SLSC) imaging, a coherence-based alternative beamforming technique, creates images related to the spatial covariance in backscatter. Because spatial covariance estimation is a computationally intensive process, efficient techni ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 20, 2014
Myocardial stiffness is an important clinical indicator of cardiac function. One of the contributors to stiffness in the heart is coronary perfusion. The interaction between cardiac tissue and coronary vasculature has been studied for several decades using ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 20, 2014
In order to implement and evaluate a basic blocked-element detection and compensation algorithm on large arrays we acquired large synthetic 2-D aperture data sets on canine ribs ex vivo. Elements that were blocked by the ribs exhibited significantly lower ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · October 20, 2014
Acoustic radiation force impulse (ARFI) imaging and shear wave elasticity imaging (SWEI) use the dynamic response of tissue to impulsive mechanical stimulus to characterize local elasticity. A variant of conventional, multiple track location SWEI (MTL-SWEI ...
Full textCite
ConferenceAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · January 2014
The possibility of measuring cardiac function noninvasively has generated wide interest in elastography imaging techniques. Shear Wave Elasticity Imaging (SWEI) is an ultrasound-based elastography technique used to measure stiffness of tissues. While this ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · December 1, 2012
Recurrence of atrial fibrillation after transcatheter ablation (TCA) is common because there is no imaging modality that can visually confirm the presence of radiofrequency ablation (RFA) lesions. We have previously shown that acoustic radiation force impu ...
Full textCite
ConferenceIEEE International Ultrasonics Symposium Ius · December 1, 2012
Four pigs, three with focal infarctions in the apical intraventricular septum (IVS) and/or left ventricular free wall (LVFW), were imaged with an intracardiac echocardiography (ICE) transducer. Custom beam sequences were used to excite the myocardium with ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Shear waves can be generated in soft tissues using impulsive acoustic radiation force (ARFI), and the resulting shear wave speeds (SWS) can be related to the shear moduli (G) by SWS = sqrt(G/rho). Time‐of‐flight (TOF) algorithms can be used to tra ...
Full textCite
ConferenceProceedings IEEE Ultrasonics Symposium · December 1, 2010
Extensive research has been devoted to the quantification of left ventricular (LV) function via an elasticity metric known as elastance. Similar to a stress-strain relation, yielding stiffness, myocardial elastance is measured from the pressure-volume (PV) ...
Full textCite
ConferenceProceedings IEEE Ultrasonics Symposium · December 1, 2007
We describe new non-invasive techniques for visualizing local variations of stiffness in cardiac tissue through the use of transthoracic acoustic radiation force impulse (ARFI) imaging. Custom M-mode and two-dimensional ARFI sequences were implemented on t ...
Full textCite
ConferenceProceedings IEEE Ultrasonics Symposium · December 1, 2007
The initial results from an ongoing clinical study investigating the utility of Acoustic Radiation Force Impulse (ARFI) imaging for in vivo visualization of abdominal lesions are presented. To date, 13 patients with lesions located in the liver (n = 11) or ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · October 15, 2007
A number of novel imaging modalities have been developed to interrogate the mechanical properties of tissue. A subset of these methods utilize acoustic radiation force to mechanically excite tissue and form images from the local responses of tissue to thes ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · September 19, 2005
Acoustic Radiation Force Impulse (ARFI) imaging utilizes brief, high-energy acoustic pulses to excite tissue and ultrasonic correlation based tracking methods to monitor the resulting tissue displacement, which reflects the relative mechanical properties o ...
Full textCite
ConferenceProc. SPIE - Int. Soc. Opt. Eng. (USA) · 2005
Acoustic radiation force impulse (ARFI) imaging uses short duration acoustic pulses to generate and subsequently determine localized displacements in tissue. Time delay estimators, such as normalized cross correlation and phase shift estimation, form the c ...
Full textLink to itemCite
ConferenceICASSP IEEE International Conference on Acoustics Speech and Signal Processing Proceedings · January 1, 2005
Acoustic Radiation Force Impulse (ARFI) imaging utilizes brief, high energy, focused acoustic pulses to generate radiation force in tissue, and ultrasonic correlation-based methods to detect the resulting tissue displacements in order to image the relative ...
Full textCite
ConferenceProceedings IEEE Ultrasonics Symposium · December 1, 2004
ARFI datasets were acquired in real time to identify differentiable features between benign and malignant breast masses in ARFI images. A modified Siemens SONOLINE Antares scanner and a VF10-5 probe were programmed to implement ARFI imaging in a multi-foca ...
Cite
ConferenceProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
Shear Wave Anisotropy Imaging is a novel method that images local variations in tissue shear wave velocity. A commercial ultrasound scanner is used to generate and track propagating shear waves. Radiation force from a brief high-energy pulse generates shea ...
Cite
ConferenceProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
Shear Wave Anisotropy Imaging is a novel method that images local variations in tissue shear wave velocity. A commercial ultrasound scanner is used to generate and track propagating shear waves. Radiation force from a brief high-energy pulse generates shea ...
Cite
ConferenceProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
In the context of complex tissue motion patterns including physiological and Acoustic Radiation Force Impulse (ARFI) -induced tissue, blood, and cyst fluid motion, the same adaptive blind source separation (BSS)-based filtering method is effective for four ...
Cite
ConferenceProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
The ability of ARFI imaging to monitor the ablation of soft tissues both ex vivo and in vivo was investigated. Thermal lesions were induced both in freshly excised bovine liver samples and in myocardial tissue of live sheep. While conventional sonography w ...
Cite
ConferenceProceedings of SPIE the International Society for Optical Engineering · September 12, 2003
Acoustic radiation force may be used to induce localized displacements within tissue. This phenomenon is used in Acoustic Radiation Force Impulse Imaging (ARFI), where short bursts of ultrasound deliver an impulsive force to a small region. The application ...
Full textCite
ConferenceProceedings of SPIE the International Society for Optical Engineering · September 12, 2003
We have developed a new method of imaging the mechanical properties of tissues based on very brief (< 1msec) and localized applications of acoustic radiation force and the ultrasonic measurement of local tissues' responses to that force. Initial results wi ...
Full textCite
ConferenceProceedings International Symposium on Biomedical Imaging · January 1, 2002
Harmonic ultrasonic imaging is often qualitatively better in the clinical setting than normal ultrasonic imaging in the same frequency range. One possible factor in the differential image quality is the degree of aberration present in the imaged tissue. Th ...
Full textCite
ConferenceProceedings International Symposium on Biomedical Imaging · January 1, 2002
Acoustic Radiation Force Impulse (ARFI) imaging utilizes brief, high energy, focused acoustic pulses to generate radiation force in remote locations in tissue, and conventional diagnostic ultrasound methods to detect the resulting tissue displacements in o ...
Full textCite
ConferenceProceedings International Symposium on Biomedical Imaging · January 1, 2002
Ultrasound image quality can be improved by incorporating elevation information from high-order arrays and adjust the beam-forming techniques to take advantage of the added information. We present the use of 1.75D ultrasound arrays for improving image qual ...
Full textCite
ConferenceLecture Notes in Computer Science Including Subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics · January 1, 2001
The Statistics Based Image Registration (SBR) method for automatic image registration is presented with application to magnetic resonance (MR)and ultrasound (US) cardiac time series images. SBR is demonstrated for MR myocardial perfusion assessment and US ...
Full textCite
ConferenceProceedings of the IEEE Ultrasonics Symposium · December 1, 2000
An ultrasonic method for remote palpation of tissue is under investigation. In this method, a single ultrasonic transducer array is used to both apply localized radiation forces within tissue and to track the resulting displacements. The magnitude of the t ...
Cite
ConferenceProceedings of the IEEE Ultrasonics Symposium · December 1, 1999
An ultrasonic radiation force-based method for remote palpation of tissue is investigated. The use of radiation force to image tissue stiffness has been proposed by several researchers. In this paper, the potential for using a diagnostic ultrasound system ...
Cite
ConferenceProceedings of the IEEE Ultrasonics Symposium · December 1, 1997
Results from a clinical study in which Streaming Detection was used to successfully differentiate fluid-filled lesions (cysts) from solid lesions in the breast are presented. Streaming Detection is an ultrasonic technique in which high intensity ultrasound ...
Cite
ConferenceProceedings of the IEEE Ultrasonics Symposium · December 1, 1996
Streaming Detection is a new ultrasonic technique proposed to distinguish fluid-filled lesions, or cysts, from solid lesions in the breast. In this technique, high intensity ultrasound pulses are used to induce acoustic streaming in cyst fluid, and this mo ...
Cite
ConferenceAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 1994
A translation system has been assembled to assist in high speed acquisition of parallel planes of ultrasonic data from phantoms and human tissue. Using a previously developed system that measures two-dimensional velocities in real time by tracking speckle ...
Cite
ConferenceProceedings of the IEEE Ultrasonics Symposium · December 1, 1993
To formulate a clinically viable methodology for tracking blood flow in two dimensions using ultrasound, one must address some challenges posed by the physical limitations of the imaging modality. At the frequencies of interest in medical diagnostic imagin ...
Cite
ConferenceProceedings IEEE Ultrasonics Symposium · January 1, 1992
Doppler flow imaging systems are limited by angledependence and aliasing. We have constructed a velocity estimator which uses the Sum Absolute Difference (SAD) algorithm [1] to track the motion of speckle in two dimensions between successive ultrasonic fra ...
Full textCite
ConferenceProceedings IEEE Ultrasonics Symposium · January 1, 1992
Clinical measurements and computer simulations were conducted to determine the effects of phase errors on image quality in large aperture systems. Using a 3.5MHz 24.5mm receive aperture, phase errors were measured across the left breasts of 6 female volunt ...
Full textCite
ConferenceProceedings IEEE Ultrasonics Symposium · January 1, 1992
We have previously proposed a two-dimensional correlation technique capable of measuring target velocities in any direction in the imaging plane and related its performance to the fundamental characteristics of speckle size and speckle decorrelation rates ...
Full textCite
ConferenceProceedings IEEE Ultrasonics Symposium · January 1, 1991
The first real-time angle-independent velocity detection system for ultrasound has been constructed. The system detects both the axial and lateral components of velocity using the SAD algorithm, a novel time-domain method for tracking speckle patterns. In ...
Full textCite
ConferenceProceedings IEEE Ultrasonics Symposium · January 1, 1991
The design, fabrication and evaluation of twodimensional transducer arrays are described for medical ultrasound imaging. A 4 x 32, 2.8 MHz array was developed to use new signal processing techniques for improved B-scan imaging including elevation focusing, ...
Full textCite
ConferenceProceedings IEEE Ultrasonics Symposium · January 1, 1991
In vivo measurements of phase aberration profiles in the breast are used to investigate the geometric requirements for phased arrays to be used in adaptive imaging. Simulation studies are then described which compare the performance of several proposed tec ...
Full textCite