Journal articleUltrasound in medicine & biology · May 2025
ObjectiveAcoustic clutter is a major source of image degradation for in vivo ultrasound imaging. However, clutter is often not represented in laboratory testing of ultrasound equipment. A phantom material is proposed that can be used to add calibr ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · October 2024
Sound speed estimation can potentially correct the focusing errors in medical ultrasound. Maximizing the echo spatial coherence as a function of beamforming sound speed is a known technique to estimate the average sound speed. However, beamformation with c ...
Full textCite
Journal articleIEEE Trans Ultrason Ferroelectr Freq Control · August 2024
This work proposes a novel method of temporal signal-to-noise ratio (SNR)-guided adaptive acoustic output adjustment and demonstrates this approach during in vivo fetal imaging. Acoustic output adjustment is currently the responsibility of sonographers, bu ...
Full textLink to itemCite
Journal articleUltrason Imaging · May 2024
This work measures temporal signal-to-noise ratio (SNR) thresholds that indicate when random noise during ultrasound scanning becomes imperceptible to expert human observers. Visible noise compromises image quality and can potentially lead to non-diagnosti ...
Full textLink to itemCite
Journal articleUltrasound Med Biol · August 2023
OBJECTIVE: Increased myocardial stiffness (MS) is an important hallmark of cardiac amyloidosis (CA) caused by myocardial amyloid deposition. Standard echocardiography metrics assess MS indirectly via downstream effects of cardiac stiffening. The ultrasound ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · May 2023
Deep abdominal images suffer from poor diffraction-limited lateral resolution. Extending the aperture size can improve resolution. However, phase distortion and clutter can limit the benefits of larger arrays. Previous studies have explored these effects u ...
Full textCite
Journal articleIEEE Trans Ultrason Ferroelectr Freq Control · July 2022
The objective of this work was to develop an automated region of the interest selection method to use for adaptive imaging. The as low as reasonably achievable (ALARA) principle is the recommended framework for setting the output level of diagnostic ultras ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · July 2022
Multi-covariate imaging of sub-resolution targets (MIST) is a statistical, model-based image formation technique that smooths speckles and reduces clutter. MIST decomposes the measured covariance of the element signals into modeled contributions from mainl ...
Full textCite
Journal articleUltrasound in medicine & biology · June 2022
Traditional pulse-echo ultrasound imaging heavily relies on the discernment of signals based on their relative magnitudes but is limited in its ability to mitigate sources of image degradation, the most prevalent of which is acoustic clutter. Advances in c ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 2022
Diffuse reverberation clutter often significantly degrades the visibility of abdominal structures. Reverberation clutter acts as a temporally stationary haze that originates from the multiple scattering within the subcutaneous layers and has a narrow spati ...
Full textCite
Journal articleUltrasound Med Biol · January 2022
Ultrasound is an essential tool for diagnosing and monitoring diseases, but it can be limited by poor image quality. Lag-one coherence (LOC) is an image quality metric that can be related to signal-to-noise ratio and contrast-to-noise ratio. In this study, ...
Full textLink to itemCite
Journal articleIEEE open journal of ultrasonics, ferroelectrics, and frequency control · January 2022
The appropriate selection of a clutter filter is critical for ensuring the accuracy of velocity estimates in ultrasound color flow imaging. Given the complex spatio-temporal dynamics of flow signal and clutter, however, the manual selection of filters can ...
Full textCite
Journal articleIEEE open journal of ultrasonics, ferroelectrics, and frequency control · January 2022
Conventional color flow processing is associated with a high degree of operator dependence, often requiring the careful tuning of clutter filters and priority encoding to optimize the display and accuracy of color flow images. In a companion paper, we intr ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · May 2021
The development of adaptive imaging techniques is contingent on the accurate and repeatable characterization of ultrasonic image quality. Adaptive transmit frequency selection, filtering, and frequency compounding all offer the ability to improve target co ...
Full textCite
Journal articleIEEE Trans Ultrason Ferroelectr Freq Control · April 2021
Cardiac imaging depends on clear visualization of several different structural and functional components to determine left ventricular and overall cardiac health. Ultrasound imaging is confounded by the characteristic speckle texture resulting from subwave ...
Full textLink to itemCite
Journal articleJ Ultrasound Med · December 2, 2020
OBJECTIVES: Ultrasound users are advised to observe the ALARA (as low as reasonably achievable) principle, but studies have shown that most do not monitor acoustic output metrics. We developed an adaptive ultrasound method that could suggest acoustic outpu ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · October 2020
Multi-covariate Imaging of Sub-resolution Targets (MIST) is an estimation-based method of imaging the statistics of diffuse scattering targets. MIST estimates the contributions of a set of covariance models to the echo data covariance matrix. Models are de ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · August 2020
The lag-one coherence (LOC), derived from the correlation between the nearest-neighbor channel signals, provides a reliable measure of clutter which, under certain assumptions, can be directly related to the signal-to-noise ratio of individual channel sign ...
Full textCite
Journal articleThe Journal of the Acoustical Society of America · August 2020
The magnitudes by which aberration and incoherent noise sources, such as diffuse reverberation and thermal noise, contribute to degradations in image quality in medical ultrasound are not well understood. Theory predicting degradations in spatial coherence ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · June 2020
Coherence-based imaging methods suffer from reduced image quality outside the depth of field for focused ultrasound transmissions. Synthetic aperture methods can extend the depth of field by coherently compounding time-delayed echo data from multiple trans ...
Full textCite
Journal articleIEEE transactions on medical imaging · June 2020
Image post-processing is used in clinical-grade ultrasound scanners to improve image quality (e.g., reduce speckle noise and enhance contrast). These post-processing techniques vary across manufacturers and are generally kept proprietary, which presents a ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · April 2020
Abdominal imaging suffers from a particularly difficult acoustic environment-targets are located deep and overlying tissue layers with varying properties generate acoustic clutter. Increasing array size can overcome the penetration and lateral resolution p ...
Full textCite
Journal articleIEEE transactions on medical imaging · February 2020
Kidney stone disease is a major health problem worldwide. Shockwave lithotripsy (SWL), which uses high-energy shockwave pulses to break up kidney stones, is extensively used in clinic. However, despite its noninvasiveness, SWL can produce cavitation in viv ...
Full textCite
Journal articleThe Journal of the Acoustical Society of America · September 2019
The van Cittert-Zernike (VCZ) theorem describes the propagation of spatial covariance from an incoherent source distribution, such as backscatter from stochastic targets in pulse-echo imaging. These stochastic targets are typically assumed statistically st ...
Full textCite
Journal articleIEEE transactions on medical imaging · July 2019
Conventional B-mode ultrasound imaging assumes that targets consist of collections of point scatterers. Diffraction, however, presents a fundamental limit on a scanner's ability to resolve individual scatterers in most clinical imaging environments. Well-k ...
Full textCite
Journal articleJournal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · May 2019
ObjectivesIntraventricular pressure (IVP) is one of the most important measurements for evaluating cardiac function, but this measurement is not currently easily assessable in the clinic. The primary reason for this is the absence of a noninvasive ...
Full textCite
Journal articleUltrasound Med Biol · May 2019
Myocardial stiffness exhibits cyclic variations over the course of the cardiac cycle. These trends are closely tied to the electromechanical and hemodynamic changes in the heart. Characterization of dynamic myocardialstiffness can provide insights into the ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · March 2019
Short-lag spatial coherence (SLSC) imaging has demonstrated improved performance over conventional B-Mode ultrasound imaging. Previous work has evaluated the performance of SLSC using 2-D matrix arrays in simulation and in vivo studies across various level ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · October 2018
Reliable assessment of image quality is an important but challenging task in complex imaging environments such as those encountered in vivo. To address this challenge, we propose a novel imaging metric, known as the lag-one coherence (LOC), which leverages ...
Full textCite
Journal articleUltrason Imaging · July 2018
Transmit beamforming has a strong impact on several factors that govern image quality, field-of-view, and frame-rate in ultrasound imaging. For cardiac applications, the visualization of fine structures and the ability to track their motion is equally impo ...
Full textLink to itemCite
Journal articleUltrasound Med Biol · April 2018
In this study, we evaluate the clinical utility of fetal short-lag spatial coherence (SLSC) imaging. Previous work has documented significant improvements in image quality with fetal SLSC imaging as quantified by measurements of contrast and contrast-to-no ...
Full textLink to itemCite
Journal articleUltrasound in medicine & biology · March 2018
Current clinical abdominal imaging arrays are designed to maximize angular field of view rather than the extent of the coherent aperture. We illustrate, in ex vivo experiments, the use of a large effective aperture to perform high-resolution imaging, even ...
Full textCite
Journal articleUltrasound in medicine & biology · March 2018
Shear wave elasticity imaging (SWEI) is a novel ultrasound elastography technique for assessing tissue stiffness. In this study, we investigate the potential of SWEI for providing diastolic functional assessment. In 11 isolated rabbit hearts, pressure-volu ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · December 2017
Conventional multiple-track-location shear wave elasticity imaging (MTL-SWEI) is a powerful tool for noninvasively estimating tissue elasticity. The resolution and noise levels of MTL-SWEI systems, however, are limited by ultrasound speckle. Single-track-l ...
Full textCite
Journal articleUltrasound Med Biol · October 2017
Tissue harmonic imaging has been widely used in abdominal imaging because of its significant reduction in acoustic noise compared with fundamental imaging. However, tissue harmonic imaging can be limited by both signal-to-noise ratio and penetration depth ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · July 2017
Radio-frequency ablation (RFA) is used to locally disrupt electrical propagation in myocardium and treat arrhythmias, and direct visualization of ablation lesions by acoustic radiation force methods may benefit RFA procedures. This paper compares four imag ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · June 2017
In Part I of this paper, we detected elements blocked by ribs during simulated and in vivo transcostal liver scans, and we turned those elements OFF to compensate for the loss in visibility of liver vasculature. Here, we apply blocked-element detection and ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · June 2017
During a transcostal ultrasound scan, ribs and other highly attenuating and/or reflective tissue structures can block parts of the array. Blocked elements tend to limit the acoustic window and impede visualization of structures of interest. Here, we demons ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · February 2017
The transverse oscillation (TO) technique can improve the estimation of tissue motion perpendicular to the ultrasound beam direction. TOs can be introduced using plane wave (PW) insonification and bilobed Gaussian apodization (BA) on receive (abbreviated a ...
Full textCite
Journal articleJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · January 2017
BackgroundMyocardial contractility, a significant determinant of cardiac function, is valuable for diagnosis and evaluation of treatment in cardiovascular disorders including heart failure. Shear wave elasticity imaging (SWEI) is a newly developed ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · September 2016
In the past decade, there has been an increased interest in characterizing cardiac tissue mechanics utilizing newly developed ultrasound-based elastography techniques. These methods excite the tissue mechanically and track the response. Two frequently used ...
Full textCite
Journal articleIEEE transactions on medical imaging · July 2016
Ultrasound image quality is often inherently limited by the physical dimensions of the imaging transducer. We hypothesize that, by collecting synthetic aperture data sets over a range of aperture positions while precisely tracking the position and orientat ...
Full textOpen AccessCite
Journal articleJournal of medical imaging (Bellingham, Wash.) · April 2016
Ultrasonography is a widely used imaging modality to visualize anatomical structures due to its low cost and ease of use; however, it is challenging to acquire acceptable image quality in deep tissue. Synthetic aperture (SA) is a technique used to increase ...
Full textCite
Journal articleIEEE Trans Med Imaging · November 2015
Measurements of plaque stiffness may provide important prognostic and diagnostic information to help clinicians distinguish vulnerable plaques containing soft lipid pools from more stable, stiffer plaques. In this preliminary study, we compare in vivo ultr ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · November 2015
The transverse oscillation method enables lateral displacement tracking by generating an oscillation orthogonal to the conventional RF signal. The widely varying methods used in the field to create such oscillations and perform displacement estimation make ...
Full textCite
Journal articleJournal of cardiovascular electrophysiology · September 2015
IntroductionElastography imaging can provide radiofrequency ablation (RFA) lesion assessment due to tissue stiffening at the ablation site. An important aspect of assessment is the spatial and temporal stability of the region of stiffness increase ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · August 2015
Shear wave imaging techniques build maps of local elasticity estimating the local group velocity of induced mechanical waves. Velocity estimates are formed using the time delay in the motion profile of the medium at two or more points offset from the shear ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · July 2015
We previously described a novel beamforming method that images the spatial correlation of an echo wave field with demonstrated applications to clutter reduction in high-noise environments. In this paper, several characteristics of the resolution and bright ...
Full textCite
Journal articleUltrason Imaging · April 2015
Fetal scanning is one of the most common applications of ultrasound imaging and serves as a source of vital information about maternal and fetal health. Visualization of clinically relevant structures, however, can be severely compromised in difficult-to-i ...
Full textLink to itemCite
Journal articleUltrasound in medicine & biology · April 2015
Acoustic radiation force impulse imaging and shear wave elasticity imaging (SWEI) use the dynamic response of tissue to impulsive mechanical stimulus to characterize local elasticity. A variant of conventional, multiple-track-location SWEI, denoted single- ...
Full textCite
Journal articleIEEE transactions on medical imaging · February 2015
Diastolic heart failure (DHF) is a major source of cardiac related morbidity and mortality in the world today. A major contributor to, or indicator of DHF is a change in cardiac compliance. Currently, there is no accepted clinical method to evaluate the co ...
Full textCite
Journal articleThe Journal of the Acoustical Society of America · January 2015
Ultrasonic echoes backscattered from diffuse media, recorded by an array transducer and appropriately focused, demonstrate coherence predicted by the van Cittert-Zernike theorem. Additive noise signals from off-axis scattering, reverberation, phase aberrat ...
Full textCite
Journal articleJ Cardiovasc Electrophysiol · December 2014
BACKGROUND: Visual confirmation of radiofrequency ablation (RFA) lesions during clinical cardiac ablation procedures could improve procedure efficacy, safety, and efficiency. It was previously shown that acoustic radiation force impulse (ARFI) imaging can ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · December 2014
The spatial coherence properties of the signal backscattered by human tissue and measured by an ultrasound transducer array are investigated. Fourier acoustics are used to describe the propagation of ultrasound through a model of tissue that includes rever ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · July 2014
Short-lag spatial coherence (SLSC) imaging is a beamforming technique that has demonstrated improved imaging performance compared with conventional B-mode imaging in previous studies. Thus far, the use of 1-D arrays has limited coherence measurements and S ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · July 2014
In Part I of the paper, we demonstrated through simulation the potential of volumetric short-lag spatial coherence (SLSC) imaging to improve visualization of hypoechoic targets in three dimensions. Here, we demonstrate the application of volumetric SLSC im ...
Full textCite
Journal articleUltrasound Med Biol · June 2014
The most common mechanical measure of the heart integrates ventricular strain between end-diastole and end-systole in order to provide a measure of contraction. Here an approach is described for estimating a correlate to local passive mechanical properties ...
Full textLink to itemCite
Journal articleUltrason Imaging · April 2014
We have previously shown that intracardiac acoustic radiation force impulse (ARFI) imaging visualizes tissue stiffness changes caused by radiofrequency ablation (RFA). The objectives of this in vivo study were to (1) quantify measured ARFI-induced displace ...
Full textOpen AccessLink to itemCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2013
Acoustic Radiation Force Impulse (ARFI) imaging has shown improved visualization of arterial structures that may provide for a more reliable assessment of atherosclerotic risk than conventional B-mode imaging. Existing ARFI imaging methods, however, are li ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2013
In an attempt to characterize the signals on the blocked elements and to assess the image degradation they cause we collected the individual-channel signals from a clinical matrix array on a phantom through a layer of absorbing rubber and on the human live ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2013
We extended the concept of Short-lag Spatial Coherence imaging to matrix arrays and used it to improve the quality of vessel images. Specifically, we collected signals from the individual channels of a clinical matrix array while imaging a flow phantom and ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2013
This paper describes the spatial coherence properties of the signal backscattered by human tissue and measured by an ultrasound transducer. Fourier acoustics are used to describe the propagation of ultrasound through a model of tissue that includes multipl ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2013
SLSC imaging is an advanced ultrasound beamforming technique that generates images of the coherence in the backscattered echo and has been shown to suppress image degradation due to clutter. However, the computational demand and the need for access to chan ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2013
Short-lag spatial coherence (SLSC) imaging has been used to reduce clutter in ultrasound imaging by using echo coherence instead of signal magnitude as a contrast mechanism. Apodization strategies used to reduce off-axis scattering in conventional B-mode i ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2013
This paper describes the spatial coherence properties of the signal backscattered by human tissue and measured by an ultrasound transducer. Fourier acoustics are used to describe the propagation of ultrasound through a model of tissue that includes multipl ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2013
Radiofrequency ablation (RFA) is commonly used to treat cardiac arrhythmias, by generating a contiguous series of discrete radiofrequency ablation (RFA) lesions in the myocardium to destroy or isolate arrhythmogenic conduction pathways. The size of each le ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2013
We have previously shown that the passive ventricular stretch induced during the active filling phase of the heart can be used to make images correlated to the passive mechanical stiffness of the ventricles. In the initial feasibility study chronic infarct ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2013
Electroanatomical Mapping (EAM) provides electrophysiologists with a three-dimensional visualization of endocardial geometry and electrical activity, used to guide transcatheter ablation (TCA) treatment of arrhythmia. Acoustic Radiation Force Impulse (ARFI ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · November 2013
Ultrasound-based elasticity imaging methods rely upon accurate estimates of tissue deformation to characterize the mechanical properties of soft tissues. These methods are corrupted by clutter, which can bias and/or increase variance in displacement estima ...
Full textCite
Journal articleUltrasound Med Biol · October 2013
Short-lag spatial coherence (SLSC) imaging is a novel beamforming technique that reduces acoustic clutter in ultrasound images. A clinical study was conducted to investigate clutter reduction and endocardial border detection in cardiac SLSC images. Individ ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · September 2013
It has been demonstrated that short-lag spatial coherence (SLSC) ultrasound imaging can provide improved speckle SNR and lesion CNR compared with conventional Bmode images, especially in the presence of noise and clutter. Application of the van Cittert-Zer ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · August 2013
Four pigs, three with focal infarctions in the apical intraventricular septum (IVS) and/or left ventricular free wall (LVFW), were imaged with an intracardiac echocardiography (ICE) transducer. Custom beam sequences were used to excite the myocardium with ...
Full textOpen AccessCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · June 5, 2013
Advanced ultrasonic beamforming techniques are often computationally intensive and difficult to implement in real-time. GPU computing has become a vital tool for software beamforming because of its massive parallel computing capabilities. However, GPU-base ...
Full textCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · June 5, 2013
Conventional wisdom in ultrasonic array design drives development towards larger arrays because of the inverse relationship between aperture size and resolution. We propose a method using synthetic aperture beamforming to study image quality as a function ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · April 2013
The development of ultrasound-based elasticity imaging methods has been the focus of intense research activity since the mid-1990s. In characterizing the mechanical properties of soft tissues, these techniques image an entirely new subset of tissue propert ...
Full textCite
Journal articleUltrasound Med Biol · March 2013
We present the results of a patient study conducted to assess the performance of two novel imaging methods, namely short-lag spatial coherence (SLSC) and harmonic spatial coherence imaging (HSCI), in an in vivo liver environment. Similar in appearance to t ...
Full textLink to itemCite
Journal articleJournal of biomechanics · January 2013
Plaque rupture is the most common cause of complications such as stroke and coronary heart failure. Recent histopathological evidence suggests that several plaque features, including a large lipid core and a thin fibrous cap, are associated with plaques mo ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 2013
Accurate and precise displacement estimation has been a hallmark of clinical ultrasound. Displacement estimation accuracy has largely been considered to be limited by the Cramer-Rao lower bound (CRLB). However, the CRLB only describes the minimum variance ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 2013
Ultrasonic displacement estimates have numerous clinical uses, including blood flow estimation, elastography, therapeutic guidance, and acoustic radiation force imaging (ARFI). These clinical tasks could be improved with better ultrasonic displacement esti ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2012
It has been demonstrated that short-lag spatial coherence (SLSC) ultrasound imaging can provide improved SNR and CNR compared to conventional B-mode images, especially in the presence of noise and clutter. Application of the van Cittert-Zernike theorem pre ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2012
To improve image quality in 3D ultrasound we extended a coherence-based imaging method named Short-lag Spatial Coherence (SLSC) imaging to 2D arrays. Specifically, we collected partially beamformed channel signals from a clinical matrix array and 3D ultras ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2012
Ultrasound-based elasticity imaging methods, such as Acoustic Radiation Force Impulse (ARFI) imaging, rely upon the accurate estimation of displacements to characterize the mechanical response of soft tissues. Sources of clutter, such as off-axis scatterin ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2012
Endocardial border visualization, a common task in echochardiography, is typically challenged by the presence of acoustic clutter. This study investigates endocardial border visibility in co-registered fundamental and harmonic data when utilizing the Short ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2012
Short-lag spatial coherence (SLSC) imaging has recently been introduced as a clutter reducing imaging technique. Thus far, SLSC has been implemented solely on one-dimensional (1D) array transducers, and the present definition is not readily applicable to t ...
Full textCite
Journal articleHeart Rhythm · November 2012
BACKGROUND: Arrhythmia recurrence after cardiac radiofrequency ablation (RFA) for atrial fibrillation has been linked to conduction through discontinuous lesion lines. Intraprocedural visualization and corrective ablation of lesion line discontinuities cou ...
Full textOpen AccessLink to itemCite
Journal articleUltrasound in medicine & biology · July 2012
Acoustic radiation force (ARF)-based methods have been demonstrated to be a viable tool for noninvasively estimating tissue elastic properties, and shear wave velocimetry has been used to measure quantitatively the stiffening and relaxation of myocardial t ...
Full textCite
Journal articleUltrasonic imaging · July 2012
Accurate sound speed estimates are desirable in a number of fields. In an effort to increase the spatial resolution of sound speed estimates, a new method is proposed for direct measurement of sound speed between arbitrary spatial locations. The method use ...
Full textCite
Journal articleUltrasonic imaging · July 2012
Acoustic radiation force impulse (ARFI) imaging has been shown to be capable of imaging local myocardial stiffness changes throughout the cardiac cycle. Expanding on these results, the authors present experiments using cardiac ARFI imaging to visualize and ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · April 2012
We introduce a harmonic version of the short-lag spatial coherence (SLSC) imaging technique, called harmonic spatial coherence imaging (HSCI). The method is based on the coherence of the second-harmonic backscatter. Because the same signals that are used t ...
Full textCite
Journal articleUltrasonic imaging · April 2012
When properly constructed, biased estimators are known to produce lower mean-square errors than unbiased estimators. A biased estimator for the problem of ultrasound time-delay estimation was recently proposed. The proposed estimator incorporates knowledge ...
Full textCite
Journal articleProceedings International Symposium on Biomedical Imaging · January 1, 2012
Clutter, a problematic noise artifact in echocardiography, appears as a diffuse haze that obscures endocardial borders and inhibits accurate diagnoses. Several approaches are available to reduce clutter in cardiac images, yet difficult-to-image patients st ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2011
The ability of an ultrasound system to differentiate signals in the presence of clutter is of key clinical importance. There are several sources of clutter but assessing their relative importance and developing methods of reducing them remain areas of acti ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2011
Short-lag spatial coherence (SLSC) imaging is a novel imaging technique based on measurements of the spatial coherence of backscattered ultrasound waves received by individual transducer elements. SLSC images are formed by integrating spatial coherence mea ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2011
Acoustic Radiation Force Impulse (ARFI) imaging techniques can be used to non-invasively evaluate the relative stiffness of tissue; potentially aiding in the identification of stiff cancerous lesions or vulnerable soft lipid filled plaques in vasculature. ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2011
There are a number of mechanisms that contribute to poor image quality in ultrasonic imaging. Numerous algorithms have been designed to compensate for phase aberrations, but recently it was shown that reverberation clutter plays a significant role in degra ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2011
Clutter is acoustic noise that significantly degrades ultrasound image quality, and often results from multiple reflections between tissue layers. There is currently little characterization of this complex phenomenon and how it depends on tissue structure. ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2011
Biased estimators with mean square error surpassing that described by the Cramer-Rao lower bound are implemented using Bayes' Theorem. In order to use Bayes' Theorem a new likelihood function was developed specifically for the ultrasound time-delay estimat ...
Full textCite
Journal articleIEEE International Ultrasonics Symposium Ius · December 1, 2011
Acoustic Radiation Force (ARF)-driven shear wave velocimetry is a validated way of quantitatively measuring tissue elasticity. Open-chest velocimetry experiments have been able to measure regional myocardial contractility, a potentially useful diagnostic p ...
Full textCite
Journal articleVascular medicine (London, England) · August 2011
Stroke is the third leading cause of death and long-term disability in the USA. Currently, surgical intervention decisions in asymptomatic patients are based upon the degree of carotid artery stenosis. While there is a clear benefit of endarterectomy for p ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · July 2011
Conventional ultrasound images are formed by delay-and-sum beamforming of the backscattered echoes received by individual elements of the transducer aperture. Although the delay-and-sum beamformer is well suited for ultrasound image formation, it is corrup ...
Full textCite
Journal articleUltrasound in medicine & biology · July 2011
A noninvasive method of characterizing myocardial stiffness could have significant implications in diagnosing cardiac disease. Acoustic radiation force (ARF)-driven techniques have demonstrated their ability to discern elastic properties of soft tissue. Fo ...
Full textCite
Journal articleUltrasonic imaging · July 2011
The progression of atherosclerotic disease is a complex process believed to be a function of the localized mechanical properties and hemodynamic loading associated with the arterial wall. It is hypothesized that measurements of cardiovascular stiffness and ...
Full textCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · June 8, 2011
In the last 20 years, the number of suboptimal and inadequate ultrasound exams has increased. This trend has been linked to the increasing population of overweight and obese individuals. The primary causes of image degradation in these individuals are ofte ...
Full textCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · June 8, 2011
The ability of an ultrasound system to differentiate signals in the presence of clutter is of key clinical importance. There are several sources of clutter but assessing their relative importance and developing methods of reducing them remain areas of acti ...
Full textCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · June 8, 2011
Acoustic radiation force impulse (ARFI) imaging has been previously described for the visualization of the cardiovascular system, including assessment of cerebral and lower-limb vascular disease, myocardial function, and cardiac RF ablation monitoring. Giv ...
Full textCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · June 8, 2011
The progression of atherosclerotic disease, caused by the formation of plaques within arteries, is a complex process believed to be a function of the localized mechanical properties and hemodynamic loading associated with the arterial wall. It is hypothesi ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · June 2011
A full-wave equation that describes nonlinear propagation in a heterogeneous attenuating medium is solved numerically with finite differences in the time domain. This numerical method is used to simulate propagation of a diagnostic ultrasound pulse through ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · April 2011
A full-wave equation that describes nonlinear propagation in a heterogeneous attenuating medium is solved numerically with finite differences in the time domain (FDTD). This numerical method is used to simulate propagation of a diagnostic ultrasound pulse ...
Full textCite
Journal articleUltrasonic imaging · April 2011
We demonstrate a novel imaging technique, named short-lag spatial coherence (SLSC) imaging, which uses short distance (or lag) values of the coherence function of backscattered ultrasound to create images. Simulations using Field II are used to demonstrate ...
Full textCite
Journal articleUltrasonic imaging · April 2011
Acoustic radiation force impulse (ARFI) imaging is being utilized to investigate mechanical properties ofcardiac tissue. The underlying physiological motion, however, presents a major challenge. This paper aims to investigate the effectiveness of various p ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2010
Conventional ultrasound images are formed by delay-and-sum beamforming ofthe backscattered echoes received by the transducer aperture. Although thedelay-and-sum beamformer is well suited for ultrasound image formation, it ischallenged under non-ideal circu ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2010
Acoustic Radiation Force Impulse (ARFI) methods have been validated formeasuring tissue elastic properties, with shear wave velocimetry emerging as aquantitative way to measure stiffness. Using ultrasound to interrogate cardiacelasticity holds promise for ...
Full textCite
Journal articleJ Cardiovasc Electrophysiol · May 2010
INTRODUCTION: Lesion placement and transmurality are critical factors in the success of cardiac transcatheter radiofrequency ablation (RFA) treatments for supraventricular arrhythmias. This study investigated the capabilities of catheter transducer based a ...
Full textLink to itemCite
Journal articleUltrasound in medicine & biology · May 2010
A method for reliable, noninvasive estimation of abdominal aortic aneurysms (AAA) wall mechanics may be a useful clinical tool for rupture prediction. An in vitro AAA model was developed from an excised porcine aorta with elastase treatment. The AAA model ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · April 2010
Cardiac motion has been tracked using various methods, which vary in their invasiveness and dimensionality. One such noninvasive modality for cardiac motion tracking is ultrasound. Three-dimensional ultrasound motion tracking has been demonstrated using de ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · January 1, 2010
High-intensity focused ultrasound (HIFU) has recently found a wide range ofapplications. In the case of ultrasound-guided HIFU, clutter andphase-aberration can degrade the image quality such that visualization of thetarget can be significantly diminished. ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · November 2009
In ultrasound images, clutter is a noise artifact most easily observed in anechoic or hypoechoic regions. It appears as diffuse echoes overlying anatomical structures of diagnostic importance, obscuring tissue borders and reducing image contrast. A novel c ...
Full textCite
Journal articleThe Journal of the Acoustical Society of America · November 2009
Optical tracking was utilized to investigate the acoustic radiation force impulse (ARFI)-induced response, generated by a 5-MHz piston transducer, in a translucent tissue-mimicking phantom. Suspended 10-microm microspheres were tracked axially and laterall ...
Full textCite
Journal articleUltrasonic imaging · July 2009
Shear wave elasticity imaging (SWEI) was employed to track acoustic radiation force impulse (ARFI)-induced shear waves in the mid-myocardium of the left ventricular free wall (LVFW) of a beating canine heart. Shear waves were generated and tracked with a l ...
Full textCite
Journal articleUltrasonic imaging · July 2009
Acoustic radiation force impulse (ARFI) imaging has been demonstrated to be capable of visualizing changes in local myocardial stiffness through a normal cardiac cycle. As a beating heart involves rapidly-moving tissue with cyclically-varying myocardial st ...
Full textCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · June 19, 2009
Harmonic imaging has been shown to yield significant improvements in image quality over conventional ultrasound imaging. It has been proposed that harmonic imaging generates these improvements by the reduction in clutter from reverberation in the tissue la ...
Full textCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · June 19, 2009
Shear wave elasticity imaging (SWEI) was employed to track acoustic radiation force (ARF)-induced shear waves in the myocardium of a beating heart. Shear waves were generated in and tracked through the myocardium of the left ventricular free wall (LVFW) in ...
Full textCite
Journal articleUltrasound In Medicine And Biology · May 2009
Atherosclerotic disease in the carotid artery is a risk factor for stroke. The susceptibility of atherosclerotic plaque to rupture, however, is challenging to determine by any imaging method. In this study, acoustic radiation force impulse (ARFI) imaging i ...
Cite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · May 2009
Acoustic radiation force impulse (ARFI) imaging characterizes the mechanical properties of tissue by measuring displacement resulting from applied ultrasonic radiation force. In this paper, we describe the current status of ARFI imaging for lower-limb vasc ...
Full textCite
Journal articleIeee Transactions On Ultrasonics Ferroelectrics And Frequency Control · March 2009
A full-wave equation that describes nonlinear propagation in a heterogeneous attenuating medium is solved numerically with finite differences in the time domain (FDTD). Three-dimensional solutions of the equation are verified with water tank measurements o ...
Cite
Journal articleUltrasonic imaging · January 2009
Acoustic radiation force (ARF) has become a common excitation mechanism in elasticity imaging. The high acoustic intensities and subsequent generation of harmonics, however, hamper the effectiveness of using conventional radiofrequency (rf) tracking to inv ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 2009
The real-time application of acoustic radiation force impulse (ARFI) imaging requires both short acquisition times for a single ARFI image and repeated acquisition of these frames. Due to the high energy of pulses required to generate appreciable radiation ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · January 1, 2009
Although harmonic imaging is used extensively, the mechanisms for image quality improvement are still poorly understood. In the simplified case of a homogeneous medium the improvements in harmonic imaging can be linked to reductions in the main lobe width ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · January 1, 2009
Cardiovascular disease remains the most likely cause of death in developed countries, accounting for approximately 870,000 deaths in the United States alone in 2004. Virtually every form of cardiovascular disease involves modifications in tissue stiffness. ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · January 1, 2009
In echocardiography, clutter is one of the most problematic image artifacts, often obscuring ventricular borders and introducing stationary noise in blood flow measurements. Clutter in transthoracic cardiac images is widely understood to originate from rev ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · January 1, 2009
Extensive research has been dedicated to investigating the assessment of left ventricular (LV) function via myocardial elasticity. Previous research has demonstrated acoustic radiation force impulse (ARFI) imaging to be capable of visualizing variations in ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · January 1, 2009
Three dimensional ultrasound motion tracking has been previously demonstrated using detected data at low volume rates. However, the effects of volume rate, kernel size and data type (raw and detected) have not been sufficiently explored. First comparisons ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2008
Clutter is a noise artifact in ultrasound images, from multiple sources. Experiments were conducted urine-filled in vivo bladders to differentiate among various sources. Successive-frame image acquisitions with varying PRFs were used to determine the clutt ...
Full textCite
Journal articleUltrasound Med Biol · October 2008
The initial results from clinical trials investigating the utility of acoustic radiation force impulse (ARFI) imaging for use with radio-frequency ablation (RFA) procedures in the liver are presented. To date, data have been collected from 6 RFA procedures ...
Full textOpen AccessLink to itemCite
Journal articleUltrasonic imaging · July 2008
Clutter is anoise artifact in ultrasound images that appears as diffuse echoes overlying signals of interest. It is most easily observed in anechoic or hypoechoic regions, such as in cysts, blood vessels, amniotic fluid, and urine-filled bladders. Clutter ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · May 2008
A novel method of physiological motion compensation for use with radiation force elasticity imaging has been developed. The method utilizes a priori information from finite element method models of the response of soft tissue to impulsive radiation force t ...
Full textCite
Journal articleUltrasonic imaging · April 2008
Intracardiac echocardiography (ICE) has demonstrated utility in providing high-resolution cardiac ultrasound images for guidance of numerous catheter-based interventions, including radiofrequency ablations (RFA). However, the training of interventionalists ...
Full textCite
Journal articleIeee Transactions On Ultrasonics Ferroelectrics And Frequency Control · March 2008
A study of numerical solutions to the linear wave equation and the parabolic wave equation is presented. Finite-difference, time-domain methods are used to calculate the acoustic field emitted from a phased diagnostic ultrasound transducer in a non-attenua ...
Cite
Journal articlePhys Med Biol · January 7, 2008
The utility of acoustic radiation force impulse (ARFI) imaging for real-time visualization of abdominal malignancies was investigated. Nine patients presenting with suspicious masses in the liver (n = 7) or kidney (n = 2) underwent combined sonography/ARFI ...
Full textOpen AccessLink to itemCite
Journal articleUltrasonic Imaging · January 2008
The Rankine-Hugoniot relation for shock wave propagation describes the shock speed of a nonlinear wave. This paper investigates time-domain numerical methods that solve the nonlinear parabolic wave equation, or the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equ ...
Cite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2007
Aberration, clutter, and reverberation degrade the quality of ultrasonic images. When an acoustic pulse propagates through tissue these effects occur simultaneously and it is difficult to obtain independent estimates for the precise source of the point spr ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2007
Acoustic radiation force impulse (ARFI) imaging has been shown to be capable of imaging the local myocardial stiffness changes of heart throughout the cardiac cycle. Expanding on these results, we have experimentally assessed cardiac ARFI imaging to be a s ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2007
A full-wave equation that describes nonlinear propagation in a heterogeneous attenuating medium is solved numerically with finite differences in the time domain (FDTD). Three dimensional solutions of the equation are verified with water tank measurements o ...
Full textCite
Journal articleUltrasound in medicine & biology · November 2007
Acoustic radiation force impulse (ARFI) imaging has been demonstrated to be capable of visualizing variations in local stiffness within soft tissue. Recent advances in ARFI beam sequencing and parallel imaging have shortened acquisition times and lessened ...
Full textCite
Journal articleUltrasound in medicine & biology · July 2007
The effect of physiological motion on the quality of radiation force elasticity images has been investigated. Experimental studies and simulated images were used to investigate the impact of motion effects on image quality metrics over a range of clinicall ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · May 2007
Intracardiac echocardiography (ICE) has been demonstrated to be an effective imaging modality for the guidance of several cardiac procedures, including radiofrequency ablation (RFA). However, assessing lesion size during the ablation with conventional ultr ...
Full textCite
Journal articleIEEE Trans. Ultrason. Ferroelectr. Freq. Control (USA) · 2007
Radiation force-based techniques have been developed by several groups for imaging the mechanical properties of tissue. Acoustic radiation force impulse (ARFI) imaging is one such method that uses commercially available scanners to generate localized radia ...
Cite
Journal article2007 4th IEEE International Symposium on Biomedical Imaging from Nano to Macro Proceedings · January 1, 2007
Acoustic radiation force imaging methods utilize acoustic radiation force to mechanically excite tissue, and the tissue response is monitored with conventional imaging methods. Radiation force based methods comprise a subset of elasticity imaging, in which ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2006
Acoustic Radiation Force Impulse (ARFI) imaging is a useful method for characterizing the local mechanical properties of tissue. ARFI imaging uses high energy, focused ultrasound pulses to generate small displacements (1-10 um) in tissue. The response of t ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2006
Acoustic Radiation Force Impulse (ARFI) imaging is a useful method for characterizing the local mechanical properties of tissue. Relevant issues in creating a real-time ARFI imaging system include patient exposure, oberservation time per image location, fi ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2006
In 1992, Zhao et al. described a variation of the speckle-brightness algorithm for phase correction on moving targets [1, 2]. By subtracting two beam-summed consecutive interrogations of a region of interest, they were able to remove effects of reverberati ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2006
Acoustic radiation force impulse (ARFI) imaging with an intra-cardiac probe has been demonstrated to be a suitable modality to monitor the progress of radiofre-quency ablation (RFA) procedures. In order to continue studies while allowing increased control ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2006
Numerical methods that solve the nonlinear parabolic wave (KZK) equation and satisfy the Rankine-Hugoniot relation for shock wave propagation at all attenuation strengths are described and characterized. By comparison with a known planar solution, it is de ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2006
Delay estimation is used in ultrasonic imaging to estimate blood flow, determine phase aberration corrections, and to calculate elastographic images. The accuracy of delay estimation methods depends on noise, bandwidth, and delay range. In most cases a sub ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2006
In vivo ARFI images of an exposed canine heart were acquired through multiple cardiac cycles. The matched eletrocardiogram (ECG) was also recorded. Sequences with the radiation force pulse amplitude set to zero were also acquired to measure potential artif ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2006
The utility and accuracy of volume visualization using 3D ARFI image data was investigated. Volumes of ARFI data were collected of custom tissue-mimicking phantoms by using a translation stage to increment the position of the imaging transducer through the ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · November 2006
Acoustic radiation force impulse imaging has been used clinically to study the dynamic response of lesions relative to their background material to focused, impulsive acoustic radiation force excitations through the generation of dynamic displacement field ...
Full textCite
Journal articleIEEE Trans Ultrason Ferroelectr Freq Control · October 2006
Constructing an ultrasonic imaging system capable of compensating for phase errors in real-time is a significant challenge in adaptive imaging. We present a versatile adaptive imaging system capable of updating arrival time profiles at frame rates of appro ...
Full textLink to itemCite
Journal articleUltrasonic imaging · October 2006
With the advent of real-time Acoustic Radiation Force Impulse (ARFI) imaging, elevated frame rates are both desirable and relevant from a clinical perspective. However, fundamental limitations on frame rates are imposed by thermal safety concerns related t ...
Full textCite
Journal articlePhys Med Biol · August 7, 2006
Previous studies have established the feasibility of monitoring radiofrequency (RF) ablation procedures with acoustic radiation force impulse (ARFI) imaging. However, questions remained regarding the utility of the technique in clinically realistic scenari ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · August 2006
We tested the feasibility of using adaptive imaging, namely phase-aberration correction, with two-dimensional (2-D) arrays and real-time, 3-D ultrasound. Because of the high spatial frequency content of aberrators, 2-D arrays, which generally have smaller ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · July 2006
The use of ultrasonic methods to track the tissue deformation generated by acoustic radiation force is subject to jitter and displacement underestimation errors, with displacement underestimation being primarily caused by lateral and elevation shearing wit ...
Full textCite
Journal articleIEEE Trans. Ultrason. Ferroelectr. Freq. Control (USA) · 2006
Delay estimation is used in ultrasonic imaging to estimate blood flow, determine phase aberration corrections, and to calculate elastographic images. Several algorithms have been developed to determine these delays. The accuracy of these methods depends in ...
Cite
Journal articleIEEE Trans. Ultrason. Ferroelectr. Freq. Control (USA) · 2006
Time-delay estimators, such as normalized cross correlation and phase-shift estimation, form the computational basis for elastography, blood flow measurements, and acoustic radiation force impulse (ARFI) imaging. This paper examines the performance of thes ...
Full textLink to itemCite
Journal articleUltrasound in medicine & biology · January 2006
Several mechanical imaging methods are under investigation that use focused ultrasound (US) as a source of mechanical excitation. Images are then generated of the tissue response to this localized excitation. One such method, acoustic radiation force impul ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2005
Non-invasive characterization of focal and diffuse atherosclerosis is difficult with existing techniques, but clinically important in guiding the selection of drug, surgical and other treatments. We describe new non-invasive techniques for monitoring vascu ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2005
Wavefront distortion induced by the skull severely impacts transcranial ultrasound. In particular, the skull reduces the ability to monitor flow in the cerebral vasculature. We present B-scan and color flow images, aberratred with polymer casts of skull bo ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2005
Time delay estimators, such as normalized cross correlation and phase shift estimation, form the computational basis for elastography, blood flow measurements and Acoustic Radiation Force Impulse (ARFI) imaging. This paper examines the performance of these ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2005
Time domain algorithms that solve the Khokhlov-Zabolotzskaya-Kuznetsov (KZK) equation are described and implemented. This equation represents the propagation of finite amplitude sound beams in a homogenous thermoviscous fluid for axisymmetric and fully thr ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2005
Radiofrequency ablation (RFA) has been demonstrated to be an effective procedure for the treatment of rapid or irregular heartbeats such as atrial fibrillation. Assessing lesion size and growth with ultrasound has been limited, as the changes within conven ...
Full textCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · September 19, 2005
Acoustic radiation force impulse (ARFI) imaging has been demonstrated to provide insight into the mechanical properties of tissue. The quality of ARFI images is dependent on the amount of acoustic energy from the radiation force pulse reaching the focus. I ...
Full textCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · September 19, 2005
Time domain algorithms that solve the Khokhlov-Zabolotzskaya-Kuznetsov (KZK) equation are described and implemented. This equation represents the propagation of finite amplitude sound beams in a homogenous thermoviscous fluid for axisymmetric and fully thr ...
Full textCite
Journal articleIEEE Trans Ultrason Ferroelectr Freq Control · September 2005
Reported real-time adaptive imaging systems use near-field phase correction techniques, which are desired because of their simple implementation and their compatibility with current system architectures. Aberrator stability is important to adaptive imaging ...
Full textLink to itemCite
Journal articleUltrasound Med Biol · September 2005
The feasibility of utilizing acoustic radiation force impulse (ARFI) imaging to assess the mechanical properties of abdominal tissues was investigated. The thermal safety of the technique was also evaluated through the use of finite element method models. ...
Full textLink to itemCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · August 16, 2005
When performing radiofrequency ablation (RFA) procedures, physicians currently have little or no feedback concerning the success of the treatment until follow-up assessments are made days to weeks later. To be successful, RFA must induce a thermal lesion o ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · July 2005
Spatial compounding reduces speckle and increases image contrast by incoherently averaging images acquired at different viewing angles. Adaptive imaging improves contrast and resolution by compensating for tissue-induced phase errors. Aberrator strength an ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · April 2005
Acoustic radiation force impulse (ARFI) imaging techniques were used to monitor radiofrequency (RF) ablation of ovine cardiac tissue in vivo. Additionally, ARFI M-mode imaging methods were used to interrogate both healthy and ablated regions of myocardial ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2004
We tested the feasibility of real time three dimensional ultrasound imaging in the brain with a 2.5MHz 2D array using a Volumetrics Model 1 scanner. In a human subject, the real time 3D scans produced simultaneous transcranial axial, coronal and saggital i ...
Cite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2004
Ten patients with suspected microcalcifications receiving treatment at the Duke University Medical Center were scanned with a 9MHz, 8x96 1.75D array transducer and Siemens Antares scanner. Aberration profiles were estimated by cross correlation of individu ...
Cite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2004
Real-time adaptive imaging systems employ near-field phase correction techniques, which are desired because of their computational simplicity and compatibility with current imaging system architectures. Aberrator stability is essential to adaptive imaging ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2004
Complex blind source separation (CBSS) is presented in application to adaptive clutter filtering for Acoustic Radiation Force Impulse (ARFI) imaging in the peripheral vasculature, in vivo. In addition to the conventional challenges of wall filtering for Do ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2004
The ability of Acoustic Radiation Force Impulse (ARFI) imaging to interrogate deep-lying abdominal tissues was investigated. Challenges involved in using ARFI imaging at depth include generating sufficient radiation force to measurably displace deep-lying ...
Cite
Journal articleUltrason Imaging · October 2004
When spatial compounding is applied to targets with significant acoustic velocity inhomogeneities, the correlation between speckle patterns of the images to be averaged decreases, thereby increasing the speckle reduction nominally obtained. Phase correctio ...
Full textLink to itemCite
Journal articleUltrasound Med Biol · September 2004
We present results of a pilot study of ex vivo and in vivo acoustic radiation force impulse (ARFI) imaging demonstrating measurements of the mechanical properties of the carotid and popliteal arteries. The results were obtained on a modified commercial sca ...
Full textLink to itemCite
Journal articleUltrasound in medicine & biology · March 2004
The ability of acoustic radiation force impulse (ARFI) imaging to visualize thermally- and chemically-induced lesions in soft tissues was investigated. Lesions were induced in freshly excised bovine liver samples. Chemical lesions were induced via the inje ...
Full textCite
Journal article2004 2nd IEEE International Symposium on Biomedical Imaging Macro to Nano · January 1, 2004
Acoustic Radiation Force Impulse (ARFI) imaging utilizes brief, high energy, focused acoustic pulses to generate radiation force in tissue, and conventional diagnostic ultrasound methods to detect the resulting tissue displacements in order to image the re ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
Spatial compounding reduces speckle and increases image contrast by incoherently averaging images acquired at different viewing angles. Adaptive imaging improves contrast and resolution by compensating for tissue induced phase errors. Aberrator strength an ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
We have created a system for real-time phase aberration correction functional with a 7.5 MHz, 1×192 element 1D linear array (Siemens) and a 9.5 MHz, 8×96 element, 1.75D linear array (Tetrad), using a Siemens Antares scanner. Aberration profiles are estimat ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
Successful adaptive imaging requires accurate measurements of the aberration profile across the array surface. A spatial filter is proposed in this work to obtain more accurate aberration measurements by suppressing wavefronts from off-axis scatterers. App ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
Successful adaptive imaging requires accurate measurements of the aberration profile across the array surface. A spatial filter is proposed in this work to obtain more accurate aberration measurements by suppressing wavefronts from off-axis scatterers. App ...
Cite
Journal articleUltrasound in medicine & biology · December 2003
Acoustic radiation force impulse (ARFI) imaging involves the mechanical excitation of tissue using localized, impulsive radiation force. This results in shear-wave propagation away from the region of excitation. Using a single diagnostic transducer on a mo ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
Acoustic Radiation Force Impulse (ARFI) imaging utilizes brief, high energy, focused acoustic pulses to generate radiation force in tissue, and conventional diagnostic ultrasound methods to detect the resulting tissue displacements in order to image the me ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
We present results of a pilot study of ex vivo and in vivo acoustic radiation force impulse (ARFI) imaging demonstrating measurements of the mechanical properties of the medial and adventitial layers in the carotid, and popliteal arteries. The data was obt ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
We present a novel, two-dimensional tissue motion estimation method using Blind Source Separation (BSS), which accurately measures both axial and lateral blood velocity components in the common carotid artery. Ensembles (packet length = 20) of raw RF data ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2003
Ultrasound phase aberration resulting from tissue velocity inhomogeneities reduce the focusing ability of ultrasound waves and degrade image quality. Two-dimensional phase aberration measurements and correction with higher-order 1.75D arrays are expected t ...
Cite
Journal articleUltrasound in medicine & biology · November 2003
Blind source separation (BSS) for adaptive filtering is presented in application to imaging both physiological and acoustic radiation force impulse (ARFI)-induced tissue and blood motion in the common carotid artery. The collected raw radiofrequency (RF) d ...
Full textCite
Journal articleProceedings of SPIE the International Society for Optical Engineering · September 12, 2003
Spatial compounding has been used for years to reduce speckle in ultrasonic images and to resolve anatomical features hidden behind the grainy appearance of speckle. Adaptive imaging restores image contrast and resolution by compensating for beamforming er ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · June 2003
Acoustic radiation force impulse (ARFI) imaging is a novel imaging modality in which pulses from a diagnostic ultrasound scanner are used to displace tissue and track its motion. The region displaced has lateral and elevational dimensions of similar scale ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 2003
Ultrasound imaging can be improved with higher order arrays through elevation dynamic focusing in future, higher channel count systems. However, modifications to current system hardware could yield increased imaging depth-of-field with 1.75D arrays (arrays ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2002
We have previously reported a technique for identifying modified prostate brachytherapy seeds. In this method, an alternating magnetic field is used to vibrate the seeds in situ with micron amplitudes. These vibrations are detected with Power Doppler or ot ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2002
Under a contract with the National Cancer Institute, we have developed an ultrasound research interface on a commercial scanner. The user can access and control a variety of scanner parameters which are not directly accessible through the clinical user int ...
Cite
Journal articleUltrasonic imaging · October 2002
A method for adaptive clutter rejection via blind source separation (BSS) using principal and independent component analyses is presented in application to blood velocity measurement in the carotid artery. In particular, the filtering method's efficacy for ...
Full textCite
Journal articleUltrason Imaging · July 2002
Acoustic Radiation Force Impulse (ARFI) imaging is a method for characterizing local variations in tissue mechanical properties. In this method, a single ultrasonic transducer array is used to both apply temporally short localized radiation forces within t ...
Full textLink to itemCite
Journal articleUltrasonic imaging · April 2002
Acoustic Radiation Force Impulse (ARFI) imaging is a method for characterizing local variations in tissue mechanical properties. In this method, a single ultrasonic transducer array is used to both apply temporally short localized radiation forces within t ...
Full textCite
Journal articleUltrasound Med Biol · February 2002
The clinical viability of a method of acoustic remote palpation, capable of imaging local variations in the mechanical properties of soft tissue using acoustic radiation force impulse (ARFI) imaging, is investigated in vivo. In this method, focused ultraso ...
Full textLink to itemCite
Journal articleProceedings of SPIE the International Society for Optical Engineering · January 1, 2002
Accurate measurement of tissue aberrations is necessary for effective adaptive ultrasound imaging. Higher order arrays provide more elements and a larger array footprint over which echo signals can be acquired. This allows for better sampling of the aberra ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · 2002
An overview is given of the Acoustic Radiation Force Impulse (ARFI) imaging. It discusses the derivation of radiation force, the response of tissue to radiation force, and the potential for this imaging method to evaluate the mechanical properties of tissu ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · January 1, 2002
A method for adaptive clutter rejection via blind signal separation (BSS) is presented in application to angle-independent blood velocity measurement in the carotid artery. Clutter filtering via frequency domain-based approaches is ineffective given short ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2001
Accurate measurement of tissue induced aberrations is necessary for effective adaptive ultrasound imaging. We acquired single channel RF data on a 6.7 MHz, 8 × 128 array (Tetrad Co.) operating at F/1.0 in azimuth and F/2.89 in elevation. This array was int ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2001
Acoustic Radiation Force Impulse (ARFI) imaging is a method for characterizing local variations in tissue mechanical response. In this method, a single ultrasonic transducer array is used to both apply temporally short localized radiation forces within tis ...
Cite
Journal articleComptes Rendus De L Academie Des Sciences Series IV Physics Astrophysics · October 1, 2001
Medical ultrasonic imaging systems assume a constant, fixed acoustic propagation velocity in tissue. This assumption allows the focusing of ultrasonic pulses in a simple way with transducer arrays with electronic delay lines. However, soft tissue acoustic ...
Full textCite
Journal articleThe Journal of the Acoustical Society of America · July 2001
A method of acoustic remote palpation, capable of imaging local variations in the mechanical properties of tissue, is under investigation. In this method, focused ultrasound is used to apply localized (on the order of 2 mm3) radiation force within tissue. ...
Full textCite
Journal articleProceedings of SPIE the International Society for Optical Engineering · January 1, 2001
We acquired conventional and harmonic channel r.f. ultrasound echo data using a 3×80 element, 8.5 MHz multirow array from the breasts of eight volunteers. The data acquisition was interleaved to allow direct comparison normal and harmonic echo wavefronts. ...
Full textCite
Journal articleUltrasound Med Biol · January 2001
Measurements of the ultrasound (US) backscatter coefficient (BSC) of fibroglandular and fatty breast tissues in vivo from 5.25 through 13 MHz, using the reference phantom method, are presented. Radiofrequency echo data were collected at a series of locatio ...
Full textLink to itemCite
Journal articleIEEE Trans. Ultrason. Ferroelectr. Freq. Control (USA) · 2001
We describe a method for estimating 2-D target motion using ultrasound. The method is based on previous ensemble tracking techniques, which required at least four parallel receive beams and 2-D pattern matching. In contrast, the method described requires o ...
Full textLink to itemCite
Journal articleProceedings of SPIE the International Society for Optical Engineering · January 1, 2001
We are investigating a novel ultrasonic method for remote palpation, which provides images of local variations in tissue stiffness. Acoustic radiation force is applied to small volumes of tissue, and the resulting displacement patterns are imaged using ult ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · 2001
Acoustic Radiation Force Impulse (ARFI) imaging is proposed as a method for characterizing local variations in tissue mechanical response. In this method, a single ultrasonic transducer array is used to both apply localized radiation forces within tissue a ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · January 1, 2001
A method for measurement of lateral blood velocity in the carotid artery is presented. Conventional Doppler methods are not capable of measuring lateral velocities since they quantify only the axial component of blood flow. 2D Speckle Tracking methods meas ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2000
Harmonic imaging has been shown to provide superior image quality in clinical studies, but few quantitative analyses of image quality have been performed. To better understand the improvements in image quality attained in vivo using harmonic imaging, we ha ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 2000
Adaptive imaging using an 8×128 array is analyzed. The array consists of switches in the handle that enables any combination of 8 rows to be selected for transmit and a different set of rows is selected for receive. The elevation aperture is changed for ea ...
Cite
Journal articleJ. Acoust. Soc. Am. (USA) · 2000
The results of a quantitative study of the impact of sound speed errors on the spatial resolution and amplitude sensitivity of a commercial medical ultrasound scanner are presented in the context of their clinical significance. The beamforming parameters o ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 2000
Streaming detection is an ultrasonic technique that can be used to distinguish fluid-filled lesions, or cysts, from solid lesions. With this technique, high intensity ultrasound pulses are used to induce acoustic streaming in cyst fluid, and this motion is ...
Full textCite
Journal articleUltrasonics (Netherlands) · 2000
Speckle tracking methods overcome the major limitations of current Doppler methods for flow imaging and quantification: angle dependence and aliasing. In this paper, we review the development of speckle tracking, with particular attention to the advantages ...
Full textLink to itemCite
Journal articlePhys. Med. Biol. (UK) · 2000
Multidimensional, high-resolution ultrasonic imaging of rapidly moving tissue is primarily limited by sparse sampling in the lateral dimension. In order to achieve acceptable spatial resolution and velocity quantization, interpolation of laterally sampled ...
Full textLink to itemCite
Journal articleUltrasonic imaging · January 2000
The early detection of breast cancer reduces patient mortality. The most common method of breast cancer detection is palpation. However, lesions that lie deep within the breast are difficult to palpate when they are small. Thus, a method of remote palpatio ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · January 1, 2000
We combine our results from a series of clinical, experimental, and analytical studies to present comprehensive recommendations for the improved visualization of breast microcalcifications with ultrasound. Such improved visualization would extend the utili ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1999
Various adaptive imaging methods have been proposed to compensate for the image degradation caused by the non-uniform acoustic velocity in soft tissues. Most adaptive imaging methods employ measurements of echo arrival times at the receive array to modify ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1999
An on-going study of the backscatter coefficient (BSC) of fibroglandular breast tissue in vivo from 5-13 MHz is discussed. Initial results of the study are compared to published values for this tissue. The implications of these findings for the ultrasound ...
Cite
Journal articleUltrasound in medicine & biology · January 1999
Results from a clinical study are presented, in which ultrasonically-induced acoustic streaming was successfully used to differentiate fluid-filled lesions (cysts) from solid lesions in the breast. In this study, high-intensity ultrasound pulses from a mod ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · January 1, 1999
Normal (9 MHz) and harmonic (9 MHz) element r.f. data were obtained for a 3×80 element array from the thyroids of ten subjects. The obtained data suggest that phase aberration is very mild in the thyroid, and that harmonic imaging reduces the effects of of ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1998
The application of a pulse-echo sound speed estimation technique to multi-layered and biological media is discussed and demonstrated in simulation, phantom, and clinical experiments. We have recently described and demonstrated a technique which estimates t ...
Cite
Journal articleIEEE Trans Ultrason Ferroelectr Freq Control · 1998
One of the fundamental limitations of medical ultrasound in the imaging of the breast is the inability of current practice to reliably visualize microcalcifications in the size range of clinical interest. Microcalcifications (MCs) are small crystals of cal ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 1998
K-space is a frequency domain description of imaging systems and targets that can be used to gain insight into image formation. Although originally proposed in ultrasound for the analysis of experiments involving anisotropic scattering and for the design o ...
Full textCite
Journal articleJ. Acoust. Soc. Am. (USA) · 1998
A method for the direct estimation of the longitudinal speed of sound in a medium is presented. This estimator derives the speed of sound through analysis of pulse-echo data received across a single transducer array following a single transmission, and is ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 1998
The performance of ultrasonic velocity estimation methods is degraded by speckle decorrelation, the change in received echoes over time. Because ultrasonic speckle is formed by the complex sum of echoes from subresolution scatterers, it is sensitive to the ...
Full textCite
Journal articleIEEE Trans. Ultrason. Ferroelectr. Freq. Control (USA) · 1998
We describe a new method, called ensemble tracking, for estimating two-dimensional velocities with ultrasound. Compared to previous speckle tracking techniques, ensemble tracking measures motion over smaller times and distances, increasing maximum velociti ...
Full textLink to itemCite
Journal articleIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · December 1, 1997
Tissue speed of sound inhomogeneities cause significant degradation of medical ultrasound images. In some cases these inhomogeneities may be modeled as a thin time delay screen located at the face of the transducer. The effects of such near-field aberratio ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1997
Published wavefront distortion (phase aberration) measurements for the human breast ranged from mild phase aberrations (8 ns r.m.s) to severe phase aberrations (67 ns r.m.s.). These measurements are required to specify arrays and assess the potentials of a ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1997
We have previously described Ensemble Tracking, a speckle tracking method that uses parallel receive processing and 2D pattern matching to generate a vector velocity map with high spatial and temporal resolution. Due to the mismatch in axial and lateral sp ...
Cite
Journal articleThe Journal of the Acoustical Society of America · April 1997
Tissue speed of sound inhomogeneities cause significant degradation of medical ultrasound images. In certain cases these inhomogeneities can be modeled as a thin, spatially varying time delay screen located at the face of the transducer. Correction of such ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 1997
Acoustic velocity inhomogeneities in tissue result in aberration of ultrasound images. These aberrations can be modeled as a near field thin phase screen or as a distributed aberrator. The effect of a near field thin phase screen is to time shift the recei ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 1997
The speckle brightness adaptive algorithm has previously been implemented in approximately real-time on low frequency, one-dimensional arrays. To increase the speed of this technique, a temporally parallel algorithm and a spatially parallel algorithm are d ...
Full textCite
Journal articleJ Acoust Soc Am · January 1997
Microcalcifications are small crystals of calcium apatites which form in human tissue through a number of mechanisms. The size, morphology, and distribution of microcalcifications are important indicators in the mammographic screening for and diagnosis of ...
Full textLink to itemCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1996
We have previously described a time-domain speckle tracking method, called Ensemble Tracking, for two dimensional vector velocity measurement. Ensemble Tracking involves parallel receive processing, 2D pattern matching, and interpolation of the resulting t ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1996
Phase aberration correction techniques require highly correlated signals at different receiver positions in order to estimate and correct for the time shifts imposed by the aberrator. The translating transmit aperture algorithm is a technique for improving ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · 1996
Microcalcifications are small crystals of calcium phosphates which form in human tissue through a number of mechanisms. The size, morphology, and distribution of microcalcifications (MCs) are important indicators in the mammographic screening for and diagn ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1995
We present computer simulations that compare the performance of three two-dimensional block-matching algorithms as applied to ultrasonic speckle. The three algorithms, normalized correlation, non-normalized correlation and Sum Absolute Difference (SAD), we ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1995
We described a new method, called ensemble tracking, for quantifying two dimensional velocities. Compared to previous two-dimensional speckle tracking techniques, ensemble tracking measures motion over smaller translations, thereby reducing errors due to s ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1995
Speed of sound inhomogeneities cause significant degradation of ultrasonic images. In some parts of the body inhomogeneities can be modeled as a thin time delay screen at the surface of the skin. Such aberrators may be compensated for by adjusting time del ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1995
Acoustic velocity inhomogeneitis in tissue result in aberration of ultrasonic images. These aberrations can be modelled as a near field thin phase screen or as a distributed aberrator. Current techniques for the correction of distributed aberrators are lim ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1995
K-Space is a frequency domain description of ultrasonic imaging systems and targets which can be used to gain insight into their interaction during image formation. Although originally proposed as a technique for the analysis of imaging problems involving ...
Cite
Journal articleIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · January 1, 1995
Delay estimation is used in ultrasonic imaging to estimate blood or soft tissue motion, to measure echo arrival time differences for phase aberration correction, and to estimate displacement for tissue elasticity measurements. In each of these applications ...
Full textCite
Journal articleUltrasound in medicine & biology · January 1995
The feasibility of a new ultrasonic technique to distinguish cysts from solid lesions is explored. High intensity pulses are used to induce acoustic streaming in cyst fluid, and this motion is detected using Doppler techniques. Acoustic streaming cannot be ...
Full textCite
Journal articleUltrasound in medicine & biology · January 1995
The performance of a two-dimensional speckle tracking system in measuring in vitro laminar flow is evaluated. The system uses a pattern matching algorithm to track subresolution-sized speckle regions between successive ultrasonic 2D pulse-echo acquisitions ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · 1995
Microcalcifications are small crystals of calcium apatites which form in human tissue through a number of mechanisms. The size, morphology, and distribution of microcalcifications are important indicators in the mammographic screening for and diagnosis of ...
Cite
Journal articleJ Am Soc Echocardiogr · 1995
A method for constructing three-dimensional images of flow is described. The technique involves the acquisition of numerous closely spaced planes, each comprised of a map of the two-dimensional velocities measured in that plane. Each such vector velocity m ...
Full textLink to itemCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1994
Improvements in medical ultrasonic image resolution are typically accompanied by significant increases in the number of piezoelectric array elements and beamformer channels. The synthetic receive aperture (SRA) imaging technique achieves dramatic improveme ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1994
Signal alignment is performed in phase aberration correction and measurement, tissue elasticity estimation, and tissue and blood velocity estimation. The performance of all these techniques is limited by errors in the alignment of signals received from spe ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1994
A two-dimensional speckle tracking system was used to measure volumetric flow rates in a free laminar jet in vitro. The system utilized the Sum-Absolute-Difference (SAD) pattern matching algorithm to track small speckle regions between successive pulse-ech ...
Cite
Journal articleIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · September 1, 1994
Cross correlation and similar operations are used in ultrasonic imaging to estimate blood or soft tissue motion in one or more dimensions and to measure echo arrival time differences for phase aberration correction. These estimates are subject to large err ...
Cite
Journal articleIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · January 1, 1994
Cross correlation and similar operations are used in ultrasonic imaging to estimate blood or soft tissue motion in one or more dimensions and to measure echo arrival time differences for phase aberration correction. These estimates are subject to large err ...
Full textCite
Journal articleIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · January 1, 1994
A common framework is presented to classify several phase correction techniques. A subset of these techniques are evaluated through simulations which utilize 2-D phase aberration profiles measured in the breast. The techniques are compared based on their a ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · January 1, 1994
Results from both a pilot clinical study and phantom studies performed to evaluate a new ultrasonic technique to distinguish cysts from solid lesions are presented. High intensity pulses are used to induce acoustic streaming in cyst fluid, and this motion ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1993
Cross correlation and similar operations are used for displacement (delay) estimation in medical ultrasound. We apply the Cramer-Rao Lower Bound to derive analytical expressions to predict the magnitude of errors in displacement estimation using radio freq ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1993
The speckle brightness phase aberration correction technique has been modified to use data from only selected elements. Simulations have demonstrated that this modification improves phase extraction performance. Initial results indicate that it performs we ...
Cite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1993
Tumors in soft tissues are often detected because of their higher stiffness relative to surrounding tissues. A number of groups have constructed systems which attempt to estimate stiffness by imaging the propagation of low frequency (<1 KHz) mechanical wav ...
Cite
Journal articleUltrasound in medicine & biology · January 1993
This paper describes a system that has been developed for measuring two-dimensional velocities in real time using ultrasound. The instrument tracks interframe speckle pattern motion using a Sum-Absolute-Difference (SAD) algorithm in order to produce a vect ...
Full textCite
Journal articleRadiology · January 1993
The authors developed an ultrasound system that enables the speckle patterns produced by echoes from moving blood to be tracked in real time. Unlike current color Doppler flow imagers, this system allows the measurement of blood velocities in any direction ...
Full textCite
Journal articleUltrason Imaging · October 1992
Two dimensional arrival time data was obtained for the propagation of ultrasound across the breasts of 7 female volunteers. These profiles were extracted through the use of cross-correlation measurements and a simulated annealing process that maintained ph ...
Full textLink to itemCite
Journal articleUltrasonic imaging · July 1992
The design, fabrication and evaluation of two-dimensional transducer arrays are described for medical ultrasound imaging. A 4 x 32, 2.8 MHz array was developed to use new signal processing techniques for improved B-scan imaging including elevation focusing ...
Full textCite
Journal articleUltrasonic imaging · April 1992
A method for correcting errors due to near-field tissue inhomogeneities in phased array ultrasound images is evaluated experimentally. The method uses the brightness of a moving speckle-generating target, such as blood, as a quality factor to correct for u ...
Full textCite
Journal articleUltrasonic imaging · April 1992
Inhomogeneous acoustic velocity in human tissue introduces phase aberration in ultrasonic imaging systems and degrades image quality. A novel technique that employs echo signals from moving diffuse targets, such as flowing blood, as an image quality factor ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 1992
For Pt.I see ibid., vol.39, p.489 (1992). The effects of tissue/transducer motion and artifacts from adaptive focusing on synthetic receive aperture (SRA) imaging are explored using experiment, simulation, and theory. The impact of these issues on the sele ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 1992
The use of a synthetic receive aperture (SRA) system to increase the resolution, of a phased-array imaging system severalfold, by utilizing the available number of parallel receiver channels to address a larger number of transducer elements through a multi ...
Full textCite
Journal articleIEEE transactions on medical imaging · January 1992
A fundamental analysis of phase aberration correction techniques which use speckle brightness-based image equality factors (QFs) to iteratively reduce phase errors is presented. Phase aberration arises from the spatial inhomogeneity of acoustic velocity in ...
Full textCite
Journal articleProceedings of the Annual Conference on Engineering in Medicine and Biology · December 1, 1991
The authors have designed and performed simulations of a synthetic receive aperture system (SRA) which can be used to address a large number of phased array channels with a relatively small number of parallel receive channels in the formation of high-resol ...
Cite
Journal articleInvest Radiol · September 1991
Experimentally obtained ultrasonic phase aberration profiles in the breast were used to investigate the impact of acoustic velocity variations on images of simulated breast lesions. The imaging properties of several phased-array transducers with varying fr ...
Full textLink to itemCite
Journal articleUltrasonic imaging · July 1991
New techniques to estimate local blood and tissue velocities have been developed by several groups, including our own. The performance of these techniques is ultimately limited by the characteristics of ultrasonic imaging systems that determine the second- ...
Full textCite
Journal articleIEEE transactions on bio-medical engineering · March 1991
Tracking the speckle patterns produced by moving targets has been shown effective for angle independent imaging of blood flow and tissue motion. While speckle tracking overcomes major limitations of Doppler-based flow imaging, the computational complexity ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 1991
The use of several alternative image-brightness-based quality factors for phase aberration correction with diffuse and point targets in coherent ultrasonic imaging systems is explored. The factors are similar to the sharpness functions proposed by R.A. Mul ...
Full textCite
Journal articleUltrason Imaging · January 1991
The phase aberrations encountered by ultrasonic pulses propagating through breast tissue in twenty-two female volunteers were measured. The experiments were designed to assess the impact of these aberrations on clinical ultrasonic image quality for a varie ...
Full textLink to itemCite
Journal articleundefined · December 1, 1990
Spatial inhomogeneities in the acoustic velocity of tissues degrade the performance of medical ultrasonic imaging systems. Two algorithms which can correct the phase aberration induced by the inhomogeneities are presented. The first algorithm adjusts the p ...
Cite
Journal articleUltrasonics Symposium Proceedings · December 1, 1990
The authors state that a synthetic receive aperture (SRA) system of a relatively simple design could increase the resolution of a phased-array imaging system several-fold, by utilizing a given number of parallel receive channels to address a larger number ...
Cite
Journal articleUltrasonics Symposium Proceedings · December 1, 1990
Inhomogeneity in acoustic velocity in tissue can introduce phase errors to diagnostic ultrasonic imaging systems and therefore degrade image quality. A novel technique for phase correction, based on the mean difference of specific brightness, that employs ...
Cite
Journal articleProceedings of the Annual Conference on Engineering in Medicine and Biology · December 1, 1990
The research program of Unit 2.1B, Real-Time Ultrasonic Flow Imaging, of the National Science Foundation/Engineering Research Center (NSF/ERC) is described. The objective of the unit's research is to develop effective techniques and prototype instrumentati ...
Cite
Journal articleInvestigative radiology · September 1990
The performance of an experimental, adaptive, phased array imaging system in improving the quality of abdominal organ images in healthy volunteers was assessed. Trials were conducted under usual clinical imaging conditions and when phase aberrators of know ...
Cite
Journal articleProceedings of SPIE the International Society for Optical Engineering · July 1, 1990
Spatial inhomogeneities in the acoustic velocity of tissues degrade the contrast and resolution of diagnostic ultrasonic images. A system which iteratively adjusts the phases of signals transmitted and received from individual elements in a phased array sc ...
Full textCite
Journal articleInvestigative Radiology · January 1, 1990
The performance of an experimental, adaptive, phased array imaging system in improving the quality of abdominal organ images in healthy volunteers was assessed. Trials were conducted under usual clinical imaging conditions and when phase aberrators of know ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 1990
An online adaptive phased-array ultrasonic imaging system capable of markedly improving the detectability of targets viewed through inhomogeneous media is described. An online adaptive phase correction technique implemented on a research phased-array scann ...
Full textCite
Journal articleUltrasonics Symposium Proceedings · December 1, 1989
A real-time adaptive ultrasonic imaging system capable of markedly and quickly improving the quality of images degraded by aberrating media is described. The system employs one of several possible functions of regional image brightness as a quality factor. ...
Cite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 1989
An apparatus to measure time-of-flight profiles in living tissues and an experimental phased-array imaging system capable of correcting unknown phase errors induced by inhomogeneities in the acoustic velocities in tissue are presented. The procedure utiliz ...
Cite
Journal articleThe Journal of the Acoustical Society of America · May 1989
Medical ultrasonic images are degraded by tissues with inhomogeneous acoustic velocities. The resulting phase aberration raises the off-peak response of the imaging system's point spread function (PSF), decreasing dynamic range. In extreme cases, multiple ...
Full textCite
Journal articleUltrasonics · September 1988
We have previously reported initial clinical results of a novel blood velocity imaging technique utilizing a two-dimensional correlation search applied to consecutively acquired echoes. In this paper, we describe both the physical principles underlying thi ...
Full textCite
Journal articleUltrasonic imaging · January 1988
In recent years, analysis of the second order statistics of ultrasound speckle has led to accurate prediction and measurements of the average speckle size in the transducer focal zone. In this paper, that work has been extended to the average speckle size ...
Full textCite
Journal articleUltrasonic imaging · January 1988
The first order statistical properties of acoustical speckle patterns are studied as a function of several types of random and structured phase error. Such errors may arise from tissue velocity inhomogeneities or limitations in the acoustical imaging syste ...
Full textCite
Journal articleUltrasonics Symposium Proceedings · December 1, 1987
A velocity imaging technique is described which operates on the envelope-detected echo signal and uses a two-dimensional correlation search method. Several experiments were performed to define the potentials and limitations of this technique. The results i ...
Cite
Journal articleProceedings of SPIE the International Society for Optical Engineering · September 10, 1987
The degree of speckle reduction achievable by spatial and frequency compounding is a function of the rates of speckle pattern change induced by varying the imaging system’s illumination angle and acoustic frequency, respectively. We have measured these rat ...
Full textCite
Journal articleIEEE Trans. Biomed. Eng. (USA) · 1987
A technique for blood velocity imaging based on tracking the motion of the speckle pattern produced by blood is presented. Unlike Doppler velocity determinations, these are angle-independent. Initial in vivo experiments yield promising results ...
Cite
Journal articleUltrasonics Symposium Proceedings · December 1, 1986
The rates of ultrasonic B-mode speckle pattern changes are measured as a function of changes in the imaging angle under a variety of experimental conditions. The results of these experiments were used to design an imaging system that optimizes speckle redu ...
Cite
Journal articleUltrasonic imaging · July 1986
Coherent speckle is a source of image noise in ultrasonic B-mode imaging. The use of multiple imaging frequencies has been suggested as a technique for speckle contrast reduction. This technique involves the averaging of images whose speckle patterns have ...
Full textCite
Journal articleUltrasound in medicine & biology · March 1986
Conventional ultrasound imaging devices are designed based on the assumption of a homogeneous tissue medium of constant acoustic velocity = 1540 m/sec. However, the body consists of tissue layers of varying thicknesses and velocities which range from 1470 ...
Full textCite
Journal articleProc. SPIE - Int. Soc. Opt. Eng. (USA) · 1986
In order to design improved spatial compounding ultrasound scanning systems it is necessary to determine the correlation of speckle patterns as a function of aperture translation. The authors have conducted experiments measuring the speckle correlation as ...
Cite
Journal articleUltrasonics Symposium Proceedings · January 1, 1986
The authors have measured the rates of ultrasonic B-mode speckle pattern changes as a function of the change in center frequency of the transmitted acoustical pulse under a variety of experimental conditions. Experimental results agree with a previous theo ...
Full textCite