Skip to main content

Jay Alan Baker

Professor of Radiology
Radiology, Breast Imaging
Box 3808 Med Ctr, Durham, NC
Dept of Radiology, Durham, NC

Featured Works


Novel tumor sampling strategies to enable microarray gene expression signatures in breast cancer: a study to determine feasibility and reproducibility in the context of clinical care.

Journal article Breast Cancer Res Treat · December 2009 Featured Work Feasibility and reproducibility of microarray biomarkers in clinical settings are doubted because of reliance on fresh frozen tissue. We sought to develop and validate a paradigm of frozen tissue collection from early breast tumors to enable use of microar ... Full text Link to item Cite

Can compression be reduced for breast tomosynthesis? Monte carlo study on mass and microcalcification conspicuity in tomosynthesis.

Journal article Radiology · June 2009 Featured Work PURPOSE: To assess, in a voxelized anthropomorphic breast phantom, how the conspicuity of breast masses and microcalcifications may be affected by applying reduced breast compression in tomosynthesis. MATERIALS AND METHODS: A breast tomosynthesis system wa ... Full text Link to item Cite

Automated breast mass detection in 3D reconstructed tomosynthesis volumes: a featureless approach.

Journal article Med Phys · August 2008 Featured Work The purpose of this study was to propose and implement a computer aided detection (CADe) tool for breast tomosynthesis. This task was accomplished in two stages-a highly sensitive mass detector followed by a false positive (FP) reduction stage. Breast tomo ... Full text Link to item Cite

A mathematical model platform for optimizing a multiprojection breast imaging system.

Journal article Med Phys · April 2008 Featured Work Multiprojection imaging is a technique in which a plurality of digital radiographic images of the same patient are acquired within a short interval of time from slightly different angles. Information from each image is combined to determine the final diagn ... Full text Link to item Cite

Training neural network classifiers for medical decision making: the effects of imbalanced datasets on classification performance.

Journal article Neural Netw · 2008 Featured Work This study investigates the effect of class imbalance in training data when developing neural network classifiers for computer-aided medical diagnosis. The investigation is performed in the presence of other characteristics that are typical among medical d ... Full text Link to item Cite

Breast mass lesions: computer-aided diagnosis models with mammographic and sonographic descriptors.

Journal article Radiology · August 2007 Featured Work PURPOSE: To retrospectively develop and evaluate computer-aided diagnosis (CAD) models that include both mammographic and sonographic descriptors. MATERIALS AND METHODS: Institutional review board approval was obtained for this HIPAA-compliant study. A wai ... Full text Link to item Cite

Digital mammography: effects of reduced radiation dose on diagnostic performance.

Journal article Radiology · May 2007 Featured Work PURPOSE: To experimentally determine the relationship between radiation dose and observer accuracy in the detection and discrimination of simulated lesions for digital mammography. MATERIALS AND METHODS: This HIPAA-compliant study received institutional re ... Full text Link to item Cite

Optimized approach to decision fusion of heterogeneous data for breast cancer diagnosis.

Journal article Med Phys · August 2006 Featured Work As more diagnostic testing options become available to physicians, it becomes more difficult to combine various types of medical information together in order to optimize the overall diagnosis. To improve diagnostic performance, here we introduce an approa ... Full text Link to item Cite

MRI-guided vacuum-assisted breast biopsy with a handheld portable biopsy system.

Journal article AJR Am J Roentgenol · June 2006 Featured Work OBJECTIVE: The purpose of this study was to evaluate a compact portable 10-gauge handheld battery-operated vacuum-assisted biopsy system for MRI-guided breast biopsy. CONCLUSION: The compact portable battery-operated biopsy system can be used successfully ... Full text Link to item Cite

Streaming detection for evaluation of indeterminate sonographic breast masses: a pilot study.

Journal article AJR Am J Roentgenol · May 2006 Featured Work OBJECTIVE: Streaming detection is a novel sonography technique that uses ultrasonic energy to induce movement in cyst fluid that is detected on Doppler sonography. This pilot study evaluates the utility of streaming detection for differentiating cysts from ... Full text Link to item Cite

Computer aid for decision to biopsy breast masses on mammography: validation on new cases.

Journal article Acad Radiol · June 2005 Featured Work RATIONALE AND OBJECTIVES: The purpose of this study was to validate the performance of a previously developed computer aid for breast mass classification for mammography on a new, independent database of cases not used for algorithm development. MATERIALS ... Full text Link to item Cite

Accuracy of segmentation of a commercial computer-aided detection system for mammography.

Journal article Radiology · May 2005 Featured Work PURPOSE: To assess the accuracy of segmentation in a commercially available computer-aided detection (CAD) system. MATERIALS AND METHODS: Approval for this study was obtained from the authors' institutional review board. Informed consent was not required b ... Full text Link to item Cite

Comparison of recall and cancer detection rates for immediate versus batch interpretation of screening mammograms.

Journal article Radiology · April 2005 Featured Work PURPOSE: To retrospectively compare recall and cancer detection rates between immediate and subsequent batch methods for interpretation of screening mammograms. MATERIALS AND METHODS: Institutional review board approval was obtained, and informed consent w ... Full text Link to item Cite

BI-RADS for sonography: positive and negative predictive values of sonographic features.

Journal article AJR Am J Roentgenol · April 2005 Featured Work OBJECTIVE: The purpose of this study was to assess the positive predictive value (PPV) and negative predictive value (NPV) of features described in the new sonographic BI-RADS lexicon for evaluating solid masses with known histologic diagnoses. MATERIALS A ... Full text Link to item Cite

Computer-aided detection of amorphous calcifications.

Journal article AJR Am J Roentgenol · March 2005 Featured Work OBJECTIVE: Computer-aided detection (CAD) systems have been used successfully to detect malignant calcifications on mammography, with sensitivities ranging from 86% to 99%. Amorphous calcifications are a subset of small indistinct calcifications of interme ... Full text Link to item Cite

Detection of primary breast carcinoma with a dedicated, large-field-of-view FDG PET mammography device: initial experience.

Journal article Radiology · February 2005 Featured Work PURPOSE: To prospectively assess a dedicated, large field of view positron emission tomography (PET) mammographic device for imaging primary breast carcinoma. MATERIALS AND METHODS: Institutional review board approval was obtained for this study, and all p ... Full text Link to item Cite

Computer-aided detection in screening mammography: variability in cues.

Journal article Radiology · November 2004 Featured Work PURPOSE: To evaluate the variability of true-positive and false-positive cues by using a commercially available computer-aided detection (CAD) system for analysis of 50 malignancies in a screening population. MATERIALS AND METHODS: Fifty breast cancers det ... Full text Link to item Cite

Accuracy of a collagen-plug biopsy site marking device deployed after stereotactic core needle breast biopsy.

Journal article AJR Am J Roentgenol · November 2003 Featured Work OBJECTIVE: The goal of this study was to compare the accuracy of clip placement of a collagen-plug biopsy marking device with that of the more conventional, previously evaluated metallic tissue-marking clips. SUBJECTS AND METHODS. The placement accuracy of ... Full text Link to item Cite

Accuracy of MRI in the detection of residual breast cancer after neoadjuvant chemotherapy.

Journal article AJR Am J Roentgenol · November 2003 Featured Work OBJECTIVE: This study was undertaken to evaluate the ability of MRI to accurately show residual primary breast malignancy in women treated with neoadjuvant chemotherapy. MATERIALS AND METHODS: Twenty-one patients with locally advanced primary breast carcin ... Full text Link to item Cite

Computer-aided detection (CAD) in screening mammography: sensitivity of commercial CAD systems for detecting architectural distortion.

Journal article AJR Am J Roentgenol · October 2003 Featured Work OBJECTIVE: Computer-aided detection (CAD) algorithms have successfully revealed breast masses and microcalcifications on screening mammography. The purpose of our study was to evaluate the sensitivity of commercially available CAD systems for revealing arc ... Full text Link to item Cite

Sonographic detection and sonographically guided biopsy of breast microcalcifications.

Journal article AJR Am J Roentgenol · April 2003 Featured Work OBJECTIVE: The purpose of this study was to evaluate the ability of sonography to depict and guide biopsies of mammographically suspicious microcalcifications and to reveal the mammographic features and histologic outcomes of lesions amenable to sonographi ... Full text Link to item Cite

Imaging-guided core needle biopsy of papillary lesions of the breast.

Journal article AJR Am J Roentgenol · November 2002 Featured Work OBJECTIVE: Our objective was to assess the incidence of papillary lesions of the breast diagnosed at imaging-guided core needle biopsy and the need for surgical excision after a benign diagnosis. MATERIALS AND METHODS: This retrospective study included 137 ... Full text Link to item Cite

Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film display.

Journal article Radiology · May 2002 Featured Work PURPOSE: To compare the speed and accuracy of the interpretations of digital mammograms by radiologists by using printed-film versus soft-copy display. MATERIALS AND METHODS: After being trained in interpretation of digital mammograms, eight radiologists i ... Full text Link to item Cite

Malignant lesions initially subjected to short-term mammographic follow-up.

Journal article Radiology · April 2002 Featured Work PURPOSE: To determine whether systematically evaluated criteria for probably benign lesions were actually applied to lesions placed into that category. MATERIALS AND METHODS: A search of the mammography database yielded 295 cases that were initially follow ... Full text Link to item Cite

Sonographically guided biopsy of suspicious microcalcifications of the breast: a pilot study.

Journal article AJR Am J Roentgenol · April 2002 Featured Work OBJECTIVE: The purpose of this study is to evaluate the use of sonographic guidance for biopsy of mammographically detected suspicious microcalcifications. SUBJECTS AND METHODS: Twenty-three patients with suspicious microcalcifications detected on mammogra ... Full text Link to item Cite

Breast US: assessment of technical quality and image interpretation.

Journal article Radiology · April 2002 Featured Work PURPOSE: To determine whether ultrasonography (US) of the breast performed at a wide range of clinical practices conforms to the American College of Radiology (ACR) standards for quality and to assess the interpretations of breast sonograms. MATERIALS AND ... Full text Link to item Cite

Cross-institutional evaluation of BI-RADS predictive model for mammographic diagnosis of breast cancer.

Journal article AJR Am J Roentgenol · February 2002 Featured Work OBJECTIVE: Given a predictive model for identifying very likely benign breast lesions on the basis of Breast Imaging Reporting and Data System (BI-RADS) mammographic findings, this study evaluated the model's ability to generalize to a patient data set fro ... Full text Link to item Cite

Negative predictive value of sonography with mammography in patients with palpable breast lesions.

Journal article AJR Am J Roentgenol · November 2001 Featured Work OBJECTIVE: This study was performed to determine the negative predictive value of sonography with mammography in evaluating palpable breast lesions. MATERIALS AND METHODS: Four hundred twenty patients with 455 palpable breast lesions were retrospectively i ... Full text Link to item Cite

Artifacts and pitfalls in sonographic imaging of the breast.

Journal article AJR Am J Roentgenol · May 2001 Featured Work Full text Link to item Cite

The evolving role of sonography in evaluating solid breast masses.

Journal article Semin Ultrasound CT MR · August 2000 Featured Work Many investigators have attempted to use ultrasound imaging to differentiate benign from malignant solid breast masses. Studies have evaluated several generations of gray-scale imaging, Doppler, color Doppler, and power Doppler imaging, and several unconve ... Full text Link to item Cite

Sonography of solid breast lesions: observer variability of lesion description and assessment.

Journal article AJR Am J Roentgenol · June 1999 Featured Work OBJECTIVE: The purpose of this study was to measure the level of inter- and intraobserver agreement and to evaluate the causes of variability in radiologists' descriptions and assessments of sonograms of solid breast masses. MATERIALS AND METHODS: Sixty so ... Full text Link to item Cite

Effect of patient history data on the prediction of breast cancer from mammographic findings with artificial neural networks.

Journal article Acad Radiol · January 1999 Featured Work RATIONALE AND OBJECTIVES: The authors evaluated the contribution of medical history data to the prediction of breast cancer with artificial neural network (ANN) models based on mammographic findings. MATERIALS AND METHODS: Three ANNs were developed: The fi ... Full text Link to item Cite

Predictive model for the diagnosis of intraabdominal abscess.

Journal article Acad Radiol · July 1998 Featured Work RATIONALE AND OBJECTIVES: The authors investigated the use of an artificial neural network (ANN) to aid in the diagnosis of intraabdominal abscess. MATERIALS AND METHODS: An ANN was constructed based on data from 140 patients who underwent abdominal and pe ... Full text Link to item Cite

Predicting breast cancer invasion with artificial neural networks on the basis of mammographic features.

Journal article Radiology · April 1997 Featured Work PURPOSE: To evaluate whether an artificial neural network (ANN) can predict breast cancer invasion on the basis of readily available medical findings (ie, mammographic findings classified according to the American College of Radiology Breast Imaging Report ... Full text Link to item Cite

Fractal texture analysis in computer-aided diagnosis of solitary pulmonary nodules.

Journal article Acad Radiol · February 1997 Featured Work RATIONALE AND OBJECTIVES: The authors investigated the use of fractal texture characterization to improve the accuracy of solitary pulmonary nodule computer-aided diagnosis (CAD) systems. METHODS: Thirty chest radiographs were acquired from patients who ha ... Full text Link to item Cite

Breast imaging reporting and data system standardized mammography lexicon: observer variability in lesion description.

Journal article AJR Am J Roentgenol · April 1996 Featured Work OBJECTIVE: The American College of Radiology has recommended the Breast Imaging Reporting and Data System (BI-RADS) as a standardized scheme for describing mammographic lesions. The objective of this study was to measure inter- and intraobserver variabilit ... Full text Link to item Cite

Artificial neural network: improving the quality of breast biopsy recommendations.

Journal article Radiology · January 1996 Featured Work PURPOSE: To evaluate the performance and inter- and intraobserver variability of an artificial neural network (ANN) for predicting breast biopsy outcome. MATERIALS AND METHODS: Five radiologists described 60 mammographically detected lesions with the Ameri ... Full text Link to item Cite

Selenium-based digital radiography of the chest: radiologists' preference compared with film-screen radiographs.

Journal article AJR Am J Roentgenol · December 1995 Featured Work OBJECTIVE: A new digital thoracic radiography system (Thoravision; Philips Medical Systems, Hamburg, Germany), which uses selenium as a detector material, was evaluated for observer preference. The system has been shown to have higher detection efficiency ... Full text Link to item Cite

Computer-aided diagnosis of breast cancer: artificial neural network approach for optimized merging of mammographic features.

Journal article Acad Radiol · October 1995 Featured Work RATIONALE AND OBJECTIVES: An artificial neural network (ANN) approach was developed for the computer-aided diagnosis of mammography using an optimally minimized number of input features. METHODS: A backpropagation ANN merged nine input features (age plus e ... Full text Link to item Cite

Breast cancer: prediction with artificial neural network based on BI-RADS standardized lexicon.

Journal article Radiology · September 1995 Featured Work PURPOSE: To determine if an artificial neural network (ANN) to categorize benign and malignant breast lesions can be standardized for use by all radiologists. MATERIALS AND METHODS: An ANN was constructed based on the standardized lexicon of the Breast Ima ... Full text Link to item Cite

Scatter compensation in digital chest radiography using the posterior beam stop technique.

Journal article Med Phys · March 1994 Featured Work A new scatter compensation technique for computed radiography based on posterior beam stop (PBS) sampled scatter measurements and the bicubic spline interpolation technique was proposed. Using only a single exposure, both the clinical image and an array of ... Full text Link to item Cite

Observer evaluation of scatter subtraction for digital portable chest radiographs.

Journal article Invest Radiol · August 1993 Featured Work RATIONALE AND OBJECTIVES: The authors compared standard digital portable chest radiographs (DPCXR) to scatter-subtracted DPCXR: METHODS: Thirty DPCXR were obtained using a photostimulable phosphor digital imaging system and a posterior beam stop (PBS) tech ... Full text Link to item Cite

Human pathologic correlation with PET in ischemic and nonischemic cardiomyopathy.

Journal article J Nucl Med · January 1993 Featured Work To assess the correlation between myocardial perfusion, metabolism and histologic findings in patients with cardiomyopathy, we evaluated myocardial perfusion and metabolism using positron emission tomography (PET) with 13NH3 (ammonia) and 18FDG (fluoro-2-d ... Link to item Cite

An artificial neural network for estimating scatter exposures in portable chest radiography.

Journal article Med Phys · 1993 Featured Work An adaptive linear element (Adaline) was developed to estimate the two-dimensional scatter exposure distribution in digital portable chest radiographs (DPCXR). DPCXRs and quantitative scatter exposure measurements at 64 locations throughout the chest were ... Full text Link to item Cite

Measurement of scatter fractions in clinical bedside radiography.

Journal article Radiology · June 1992 Featured Work The authors present measurements of scatter fraction (SF), the ratio of scattered to total imaged photons, from clinical bedside radiographs of 102 patients. These measurements were obtained by using a new posterior beam-stop technique that does not alter ... Full text Link to item Cite

Posterior beam-stop method for scatter fraction measurement in digital radiography.

Journal article Invest Radiol · February 1992 Featured Work The authors presented a new posterior beam-stop (PBS) technique for measuring the ratio of scattered to total-detected photon flux (scatter fraction) in a radiographic examination while preserving the diagnostic quality of the image. The scatter measuremen ... Full text Link to item Cite

The effect of metabolic milieu on cardiac PET imaging using fluorine-18-deoxyglucose and nitrogen-13-ammonia in normal volunteers.

Journal article J Nucl Med · August 1991 Featured Work Cardiac PET imaging using 13N-ammonia and 18FDG was performed on 17 normal volunteers in the glucose-loaded and fasted states. PET images (glucose-loaded and fasted) were subjected to qualitative visual analysis using the descriptors: image quality, FDG bl ... Link to item Cite