Skip to main content

Jennifer Colleen O'Daniel

Associate Professor of Radiation Oncology
Radiation Oncology
3643 North Roxboro Street, Durham, NC 27704
00567 Duke South Red Zone Base, Box 3295 DUMC, Durham, NC 27710

Scholarly Works - Conferences


Impact of Target Volume and Image Guidance on Post-Prostatectomy Patients Treated With Intensity Modulated Radiation Therapy.

Conference International journal of radiation oncology, biology, physics · November 2021 Purpose/objective(s)Post-operative radiotherapy (PORT) is utilized in select prostate cancer patients. IMRT has been associated with improved dosimetry and acute toxicity. Smaller treatment margins for PORT have been recommended when using image g ... Full text Cite

TU‐C‐108‐07: Transmission Detector Array System for RT Delivery Monitoring: Validation Testing

Conference Medical Physics · January 1, 2013 Purpose: To quantify the influence of the gantry‐mounted Delta4‐AT detector array on beam quality, and the detection sensitivity to machine output and MLC position deviations. Methods: A Delta4‐AT prototype was attached to the accessory holder mount of a V ... Full text Cite

Comprehensive quality assurance for base of skull IMRT.

Conference J Phys Conf Ser · 2013 Six base of skull IMRT treatment plans were delivered to Presage dosimeters within the RPC Head and Neck Phantom for quality assurance (QA) verification. Isotropic 2mm 3D data were acquired by optical-CT scanning with the DLOS system (Duke Large Optical-CT ... Full text Link to item Cite

SU‐E‐T‐98: VMAT Quality Assurance: Improving the Angular Correction Factors for Ion Chamber Arrays

Conference Medical Physics · January 1, 2011 Purpose: Two‐dimensional (2D) detector arrays for QA of volumetric‐modulated‐arc‐therapy (VMAT) plans show angular dependence. An angular correction‐factor‐table (CFs) minimize this effect, but assumes: (1) the response of all ion chambers (IC) is identica ... Full text Cite

TU‐E‐BRC‐08: Investigation of Anatomical Surrogate for 4DCT Imaging

Conference Medical Physics · January 1, 2011 Purpose: Respiratory signal for 4DCT is typically extracted using an external respiratory positioning management device (RPM) which is often inconvenient and time consuming. The efficiency of 4DCT imaging could be substantially improved if anatomical body ... Full text Cite

Intensity Modulated Arc Therapy: Effective and Efficient End-to-end Patient Specific Quality Assurance

Conference International Journal of Radiation Oncology*Biology*Physics · November 2010 Full text Cite

SU‐GG‐T‐225: Gantry‐Angle Dependence of a 2D Ion Chamber Array for IMAT QA

Conference Medical Physics · January 1, 2010 Purpose: Gantry‐angle dependence of dose measurement for intensity‐modulated arc therapy (IMAT) quality assurance (QA) using a two‐dimensional ion chamber array may be significant. A new device, the gantry angle sensor, has been provided to compensate for ... Full text Cite

SU‐GG‐T‐583: Dosimetric Comparison of Anisotropic Analytical and Pencil Beam Convolution Algorithms in Breast Cancer Radiation Treatment Planning

Conference Medical Physics · January 1, 2010 Purpose: The anisotropic analytical algorithm (AAA) has been shown to provide more accurate dose calculation due to 3D scatter and inhomogeneity corrections than the pencil beam convolution algorithm (PBC) for inhomogeneous anatomical regions such as lung ... Full text Cite

SU‐FF‐T‐545: Feasibility Study for Treatment of Intracranial Multi‐Focal Stereotactic Radiosurgery with Multiple Intensity Modulated Arc Technique

Conference Medical Physics · January 1, 2009 Objectives: To investigate the feasibility of using an intensity modulated arc technique for multi‐focal intracranial stereotactic radiosurgery with a single isocenter setup to significantly decrease the treatment time. Methods: A Novalis Tx linear acceler ... Full text Cite

SU‐FF‐T‐301: Clinical Implementation and Commission of Volumetric Modulated Arc Therapy

Conference Medical Physics · January 1, 2009 Purpose Volumetric modulated arc therapy (VMAT) is a rotational IMRT modality that combines dose rate modulation with gantry and MLC motion, thereby increasing the complexity of IMRT delivery. Effective implementation of this technology is still quite new ... Full text Cite

SU‐FF‐T‐314: Patient‐Specific Quality Assurance Techniques for RapidArc Radiotherapy

Conference Medical Physics · January 1, 2009 Purpose: To develop a patient‐specific quality assurance protocol for RapidArc™ radiotherapy. Method and Materials: Following the commissioning of RapidArc™ treatment delivery, we tested several methods of patient‐specific quality assurance (QA). Ion chamb ... Full text Cite

SU‐FF‐J‐56: Integrating Real‐Time Tracking Into Image Guided Radiation Therapy for Prostate Cancer Treatment

Conference Medical Physics · January 1, 2009 Purpose: To investigate how a real‐time tracking technique, based on implanted transponders, could be effectively integrated into the current process for image‐guided radiation treatment of prostate cancer. Method and Materials: Current prostate IGRT proce ... Full text Cite

SU‐FF‐J‐55: Acceptance Testing and Quality‐Assurance Protocols for the Calypso® 4D Localization System™ and Q‐Fix®/Calypso® Couchtop

Conference Medical Physics · January 1, 2009 Purpose: To develop quality‐assurance (QA) protocols for the Calypso® 4D Localization System including acceptance testing, commissioning, daily QA, monthly QA, and annual QA. Method and Materials: The following acceptance testing/commissioning/QA protocols ... Full text Cite

TU‐E‐304A‐06: A 3D Solution for Advanced Photon Arc Therapy Quality Assurance

Conference Medical Physics · January 1, 2009 Purpose: Recently, radiation treatment technology has out‐paced the advances in QA technology, and a critical gap has been created within the arc motion delivery systems such as Rapid Arc®, High Art®, and VMAT®. Gantry position, speed and MU rate create ex ... Full text Cite

SU‐GG‐T‐72: A New Technique to Prevent Target Underdosage in Anal Cancer IMRT

Conference Medical Physics · January 1, 2008 Purpose: Target coverage is of outmost importance for curative radiation treatment of anal cancers. When the tumor is close to the skin surface, inferior patient displacements could cause significant dosimetric losses. Moreover, the PTV may extend beyond t ... Full text Cite

SU‐AA‐350‐01: Student Meeting

Conference Medical Physics · January 1, 2008 The annual AAPM student meeting welcomes current and prospective trainees in medical physics. Speakers will address issues of importance to trainees, including the impact of the 2012/2014 residency requirement for the ABR, and what the AAPM is doing to inc ... Full text Cite

SU‐EE‐A3‐02: Image‐Guided Planning Margin Determination for Concomitant Boost Treatment of 3D‐Conformal, IMRT, and Stereotactic Lung Cancer Radiotherapy

Conference Medical Physics · January 1, 2008 Purpose: To determine appropriate planning margins around the GTV for concomitant boost image‐guided lung cancer treatments where the GTV is prescribed a higher dose than the CTV. Method and Materials: The dosimetric impact of the GTV planning margin (pGTV ... Full text Cite

Daily Bone Alignment With Limited Repeat CT Correction Rivals Daily Ultrasound Alignment for Prostate Radiotherapy

Conference International Journal of Radiation Oncology*Biology*Physics · November 2007 Full text Cite

TU‐C‐ValB‐08: Modeling Dose Delivery Accuracy of IMRT Head‐And‐Neck Cancer Treatment

Conference Medical Physics · January 1, 2006 Purpose: To evaluate the impact of internal organ variations on IMRT treatments of head‐and‐neck cancers using different daily alignment techniques. Method and Materials: Eleven head‐and‐neck cancer patients were imaged twice weekly during their course of ... Full text Cite

WE‐E‐ValA‐02: Dosimetric Comparison of the No Action Level Alignment Protocol with Daily Alignment Techniques for Prostate Cancer

Conference Medical Physics · January 1, 2006 Purpose: To compare the effectiveness of two off‐line “No‐Action‐Level” (NAL) correction protocols with daily image‐guided alignments using bony registration (simulating electronic portal image alignment), ultrasound, and CT for direct prostate target loca ... Full text Cite

TU‐C‐ValB‐03: The Dosimetric Impact of Intrafractional Motion On IMRT Treatment of Prostate Cancer

Conference Medical Physics · January 1, 2006 Purpose: To quantify the dosimetric impact of intrafractional motion on reduced‐margin IMRT treatments of prostate cancer. Methods and Materials: CT images were acquired immediately before and after a daily treatment for 46 prostate cancer patients. These ... Full text Cite

Inter-observer Contouring Variations of Head-and-Neck Anatomy

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

Dosimetric Assessment of Daily Skin, Bone, Ultrasound and CT Alignment for Prostate Cancer IMRT

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

Dosimetric comparison of daily prostate alignment utilizing skin marks, ultrasound, and in-room CT

Conference INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS · January 1, 2004 Link to item Cite