Journal articlePhys Med · August 2025
PURPOSE: To develop and characterize individualized dose and quality measures at organ level compared to their generic counterparts across a clinical CT dataset. MATERIALS AND METHODS: The study included 9801 chest-abdomen-pelvis and abdomen-pelvis CT exam ...
Full textOpen AccessLink to itemCite
Journal articleEur Radiol · April 2021
OBJECTIVE: The purpose of this study was to determine how well radiologists could visually detect a change in lung nodule size on the basis of visual image perception alone. SUBJECTS AND METHODS: Under IRB approval, 109 standard chest CT image series were ...
Full textLink to itemCite
Journal articleAcad Radiol · May 2019
RATIONALE AND OBJECTIVES: To assess if a liquid tissue surrogate for the liver (LTSL) can emulate contrast-enhanced liver parenchyma and lesions and quantify the impact of reduced-kV imaging as a function of lesion contrast, phase of enhancement, and phant ...
Full textLink to itemCite
Journal articleEur Radiol · April 2019
OBJECTIVES: To assess the impact of scan- and patient-related factors on the error and the minimum detectable difference in iodine concentration among different generations of single-source (SS) fast kV-switching and dual-source (DS) dual-energy CT (DECT). ...
Full textLink to itemCite
Journal articleMed Phys · April 2019
PURPOSE: To make available to the medical imaging community a computed tomography (CT) image database composed of hybrid datasets (patient CT images with digitally inserted anthropomorphic lesions) where lesion ground truth is known a priori. It is envisio ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · March 2019
OBJECTIVE: The purpose of this study was to assess the impact of high pitch values on image noise, spatial resolution, and iodine quantification in single-source wide-coverage fast-kilovoltage-switching dual-energy CT (DECT). MATERIALS AND METHODS: Two pha ...
Full textLink to itemCite
Journal articleJ Med Imaging (Bellingham) · January 2019
We propose to characterize the bias and variability of quantitative morphology features of lung lesions across a range of computed tomography (CT) imaging conditions. A total of 15 lung lesions were simulated (five in each of three spiculation classes: low ...
Full textLink to itemCite
Journal articleMed Phys · November 2018
PURPOSE: The purpose of this study was to investigate how accurately the task-transfer function (TTF) models the signal transfer properties of low-contrast features in a non-linear commercial CT system. METHODS: A cylindrical phantom containing 24 anthropo ...
Full textLink to itemCite
Journal articleJ Med Imaging (Bellingham) · October 2018
The purpose of this study is to (1) develop metrics to characterize the regional anatomical complexity of the lungs, and (2) relate these metrics with lung nodule detection in chest CT. A free-scrolling reader-study with virtually inserted nodules (13 radi ...
Full textLink to itemCite
Journal articleJ Med Imaging (Bellingham) · July 2018
This study's purpose was to develop and validate a method to estimate patient-specific detectability indices directly from patients' CT images (i.e., in vivo). The method extracts noise power spectrum (NPS) and modulation transfer function (MTF) resolution ...
Full textLink to itemCite
Journal articleMed Phys · July 2018
PURPOSE: The task-based assessment of image quality using model observers is increasingly used for the assessment of different imaging modalities. However, the performance computation of model observers needs standardization as well as a well-established t ...
Full textLink to itemCite
Journal articleJ Med Imaging (Bellingham) · July 2018
Using hybrid datasets consisting of patient-derived computed tomography (CT) images with digitally inserted computational tumors, we establish volumetric interchangeability between real and computational lung tumors in CT. Pathologically-confirmed malignan ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · June 2018
OBJECTIVE: The purpose of this study was to assess image noise, spatial resolution, lesion detectability, and the dose reduction potential of a proprietary third-generation adaptive statistical iterative reconstruction (ASIR-V) technique. MATERIALS AND MET ...
Full textLink to itemCite
Journal articleMed Phys · November 2017
PURPOSE: Dual-energy computed tomography virtual monoenergetic imaging (VMI) at 40 keV exhibits superior contrast-to-noise ratio (CNR), although practicing radiologists do not consistently prefer it over VMI at 70 keV due to high perceivable noise. We hypo ...
Full textLink to itemCite
Journal articleRadiology · September 2017
Purpose To determine the effect of radiation dose and iterative reconstruction (IR) on noise, contrast, resolution, and observer-based detectability of subtle hypoattenuating liver lesions and to estimate the dose reduction potential of the IR algorithm in ...
Full textLink to itemCite
Journal articlePhys Med Biol · August 22, 2017
Virtual nodule insertion paves the way towards the development of standardized databases of hybrid CT images with known lesions. The purpose of this study was to assess three methods (an established and two newly developed techniques) for inserting virtual ...
Full textLink to itemCite
Journal articleRadiology · May 2017
Purpose To develop, in a phantom environment, a method to obtain multidetector computed tomographic (CT) data sets at multiple radiation exposure levels within the same patient and to validate its use for potential dose reduction by using different image r ...
Full textLink to itemCite
Journal articleMed Phys · December 2016
PURPOSE: To use novel voxel-based 3D printed textured phantoms in order to compare low-contrast detectability between two reconstruction algorithms, FBP (filtered-backprojection) and SAFIRE (sinogram affirmed iterative reconstruction) and determine what im ...
Full textLink to itemCite
Journal articleJ Med Imaging (Bellingham) · July 2016
This study aims to characterize the effect of background tissue density and heterogeneity on the detection of irregular masses in breast tomosynthesis, while demonstrating the capability of the sophisticated tools that can be used in the design, implementa ...
Full textLink to itemCite
Journal articleJ Med Imaging (Bellingham) · July 2016
The purpose of this study was to compare computed tomography (CT) low-contrast detectability from human readers with observer model-based surrogates of image quality. A phantom with a range of low-contrast signals (five contrasts, three sizes) was imaged o ...
Full textLink to itemCite
Journal articleRadiology · April 2016
PURPOSE: To determine if radiation dose and reconstruction algorithm affect the computer-based extraction and analysis of quantitative imaging features in lung nodules, liver lesions, and renal stones at multi-detector row computed tomography (CT). MATERIA ...
Full textLink to itemCite
Journal articleMed Phys · August 2015
PURPOSE: The purpose of this work was to assess the inherent image quality characteristics of a new multidetector computed tomography system in terms of noise, resolution, and detectability index as a function of image acquisition and reconstruction for a ...
Full textLink to itemCite
Journal articleRadiology · June 2015
PURPOSE: To assess the effect of radiation dose reduction on low-contrast detectability by using an advanced modeled iterative reconstruction (ADMIRE; Siemens Healthcare, Forchheim, Germany) algorithm in a contrast-detail phantom with a third-generation du ...
Full textLink to itemCite
Journal articleMed Phys · December 2014
PURPOSE: Iterative reconstruction (IR) offers notable advantages in computed tomography (CT). However, its performance characterization is complicated by its potentially nonlinear behavior, impacting performance in terms of specific tasks. This study aimed ...
Full textLink to itemCite
Journal articlePhys Med Biol · November 7, 2014
Realistic three-dimensional (3D) mathematical models of subtle lesions are essential for many computed tomography (CT) studies focused on performance evaluation and optimization. In this paper, we develop a generic mathematical framework that describes the ...
Full textLink to itemCite
Journal articleMed Phys · September 2014
PURPOSE: Quantum noise properties of CT images are generally assessed using simple geometric phantoms with uniform backgrounds. Such phantoms may be inadequate when assessing nonlinear reconstruction or postprocessing algorithms. The purpose of this study ...
Full textLink to itemCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2014
Commercially available computed Tomography (CT) Technologies such as iterative reconstruction (IR) have The potential To enable reduced patient doses while maintaining diagnostic image quality. However, systematically determining safe dose reduction levels ...
Full textCite
Journal articleMed Phys · June 2013
PURPOSE: Daily image quality assessment is an essential part of a rigorous quality control program. Time constraints; however, make it difficult to fully analyze image quality daily. Therefore, the goal of this work was to develop a robust automated CT qua ...
Full textLink to itemCite
Journal articleAJR Am J Roentgenol · March 2013
OBJECTIVE: Modern CT systems use surrogates of noise-noise index (NI) and quality reference effective tube current-time product (Q)-to infer the quality of images acquired using tube current modulation. This study aimed to determine the relationship betwee ...
Full textLink to itemCite
Journal articleMed Phys · October 2012
PURPOSE: To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). METHODS: The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Midd ...
Full textLink to itemCite