ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2025
Medical imaging simulation studies benefit from the use of virtual phantoms since they present a defined ground-truth to evaluate and optimize imaging devices and techniques. Currently, these phantoms are primarily morphologically focused, surface-based re ...
Full textCite
ConferenceProceedings 22nd IEEE International Conference on Machine Learning and Applications Icmla 2023 · January 1, 2023
Proton beam therapy is an advanced form of cancer radiotherapy that uses high-energy proton beams to deliver precise and targeted radiation to tumors. This helps to mit-igate unnecessary radiation exposure in healthy tissues. Real-time imaging of prompt ga ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2020
The application of MRI significantly improves the accuracy and reliability of target delineation for many disease sites in radiotherapy due to its superior soft tissue contrast as compared to CT. However, MRI data do not contain the electron density inform ...
Full textCite
ConferenceMed Phys · June 2016
PURPOSE: To develop a data-mining methodology based on quantum clustering and machine learning to predict expected dosimetric endpoints for lung SBRT applications based on patient-specific anatomic features. METHODS: Ninety-three patients who received lung ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: To investigate the feasibility of a novel marker-less motion-modeling based method for automatic 4D-CBCT projection phase sorting. METHODS: Patient on-board image volume at any instant is considered as a deformation of one phase of the prior plann ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. METHODS: A previous metho ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: To develop a methodology based on digitally-reconstructed-fluoroscopy (DRF) to quantitatively assess target localization accuracy of lung SBRT, and to evaluate using both a dynamic digital phantom and a patient dataset. METHODS: For each treatment ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: To develop a technique generating ultrafast on-board VC-MRI using prior 4D-MRI and on-board phase-skipped encoding k-space acquisition for real-time 3D target tracking of liver and lung radiotherapy. METHODS: The end-of-expiration (EOE) volume in ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: To develop an adaptive prior knowledge based image estimation method to reduce the scan angle needed in the LIVE system to reconstruct 4D-CBCT for intrafraction verification. METHODS: The LIVE system has been previously proposed to reconstructs 4D ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: Respiratory-gated radiotherapy and dynamic tracking employ real-time imaging and surrogate motion-monitoring methods with tumor motion prediction in advance of real-time. This study investigated respiratory motion data length on prediction accurac ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: In order to track the tumor movement for patient positioning verification during arc treatment delivery or in between 3D/IMRT beams for stereotactic body radiation therapy (SBRT), the limited-angle kV projections acquisition simultaneously during ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: To investigate the feasibility of using structure-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potentia ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
The delivery techniques for SRS/SBRT have been under rapid developments in recent years, which pose new challenges to medical physicists ranging from planning and quality assurance to imaging and motion management. This educational course will provide a ge ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: To enable efficient and consistent registrationbetween source and target images, related bynonlinear but periodic deformation, with particular focus on 4D CTimages. METHODS: We present a non-iterative method for inverting forward (or backward) def ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
The delivery techniques for SRS/SBRT have been under rapid developments in recent years, which pose new challenges to medical physicists ranging from planning and quality assurance to imaging and motion management. This educational course will provide a ge ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: To facilitate adaptive image filtering operations, addressing spatial variations in both noise and signal. Such issues are prevalent in cone-beam projections, where physical effects such as X-ray scattering result in spatially variant noise, viola ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: To circumvent the ill-posedness in the problem to estimate inhomogeneous motion or deformation field without resorting to global regularization conditions. METHODS: We present a novel method for deformable registration. First, we estimate the defo ...
Full textLink to itemCite
ConferenceMed Phys · June 2016
PURPOSE: To address and lift the limited degree of freedom (DoF) of globally bilinear motion components such as those based on principal components analysis (PCA), for encoding and modeling volumetric deformation motion. METHODS: We provide a systematic ap ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To develop a technique to generate on-board VC-MRI using patient prior 4D-MRI, motion modeling and on-board 2D-cine MRI for real-time 3D target verification of liver and lung radiotherapy. METHODS: The end-expiration phase images of a 4D-MRI acqui ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: Delta4 dosimetric software can be used to calculate DVH-based metrics for patient-specific quality assurance from measurements made by a Delta4 QA device. This study investigates the effectiveness of a novel transform method that transposes measur ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
UNLABELLED: Radiotherapy of moving targets, such as lung, liver or prostate tumors, is prone to treatment errors due to the uncertainties in the target position. Minimizing such error is critical for radiotherapy treatments, especially hypofractionated SBR ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To investigate the feasibility of using region-based principal component analysis (PCA) for motion modeling to estimate on-board 4D-CBCT using prior information and limited angle projections for potential 4D target verification of lung radiotherap ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: Target tracking or gating the radiation beam using real-time imaging and surrogate motion monitoring methods are employed for dynamic tracking treatment or respiratory-gated radiotherapy. This method requires tumor motion prediction far enough in ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: A synchronized moving grid (SMOG) has been proposed to reduce scatter and lag artifacts in cone beam computed tomography (CBCT). However, information is missing in each projection because certain areas are blocked by the grid. A previous solution ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To present a cone beam computed tomography (CBCT) system, which uses a synchronized moving grid (SMOG) to reduce and correct scatter, an inter-projection sensor fusion (IPSF) algorithm to estimate the missing information blocked by the grid, and a ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To investigate the dosimetric accuracy of CBCTs estimated by a motion modeling and free-form deformation(MM-FD) technique for radiotherapy of lung cancer. METHODS: Various inter-fractional variations featuring patient motion pattern change, tumor ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: Adaptive denoising and encoding of 4D deformation-vector-field (DVF) extracted from 4D planning CT, for modeling patient dominant motion features across coupled trajectory dimensions and respiratory phases. METHODS: We propose a multi-layer spectr ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To develop a dual-detector phase-matched DTS technique for continuous and fast intra-treatment lung tumor localization. METHODS: Tumor localization accuracy of limited-angle DTS imaging is affected by low inter-slice resolution. The dual-detector ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To facilitate fast and accurate iterative volumetric image reconstruction from limited-angle on-board projections. METHODS: Intrafraction motion hinders the clinical applicability of modern radiotherapy techniques, such as lung stereotactic body r ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To evaluate the dosimetry of microscopic disease (MD) region of lung cancer in stereotactic body radiation therapy (SBRT). METHODS: For simplicity, we assume organ moves along one dimension. The probability distribution function of tumor position ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To develop an automatic markerless 4D-CBCT projection sorting technique by using a patient respiratory motion model extracted from the planning 4D-CT images. METHODS: Each phase of onboard 4D-CBCT is considered as a deformation of one phase of the ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: To evaluate the quality of monochromatic images at the same virtual monochromatic energy using dual cone-beam computed tomography (CBCT) with either kV/kV or MV/kV or MV/MV energy sets. METHODS: CT images of Catphan 504 phantom were acquired using ...
Full textLink to itemCite
ConferenceComput Model Objects Present Images (2014) · September 2014
Cone beam computed tomography (CBCT) imaging is a key step in image guided radiation therapy (IGRT) to improve tumor targeting. The quality and imaging dose of CBCT are two important factors. However, X-ray scatter in the large cone beam field usually indu ...
Full textLink to itemCite
ConferenceMed Phys · June 2014
PURPOSE: to implement the newly developed synchronized moving grid (SMOG) system on a prototype dual-source CBCT system to evaluate its efficacy for scatter reduction and correction under various settings, including different phantom size, grid ratio and i ...
Full textLink to itemCite
ConferenceMed Phys · June 2014
PURPOSE: To quantitatively evaluate a 3D patient specific QA tool using 2D film and 3D Presage dosimetry. METHODS: A brain IMRT case was delivered to Delta4, EBT2 film and Presage plastic dosimeter. The film was inserted in the solid water slabs at 7.5cm d ...
Full textLink to itemCite
ConferenceMed Phys · June 2014
PURPOSE: To develop a novel adaptive reconstruction strategy to further reduce the scanning angle required by the limited-angle intrafraction verification (LIVE) system for intrafraction verification. METHODS: LIVE acquires limited angle MV projections fro ...
Full textLink to itemCite
ConferenceMed Phys · June 2014
PURPOSE: To develop a quasi-cine CBCT reconstruction technique that uses extremely-small angle (∼3°) projections to generate real-time high-quality lung CBCT images. METHOD: 4D-CBCT is obtained at the beginning and used as prior images. This study uses ext ...
Full textLink to itemCite
ConferenceMed Phys · June 2014
PURPOSE: Synchronized moving grid (SMOG) is a promising technique to reduce scatter and ghost artifacts in cone beam computed tomography (CBCT). However, the grid blocks part of image information in each projection, and multiple projections at the same gan ...
Full textLink to itemCite
ConferenceMed Phys · June 2014
PURPOSE: To evaluate a 4D-CBCT reconstruction technique both geometrically and dosimetrically METHODS: A prior-knowledge guided 4DC-BCT reconstruction method named the motion-modeling and free-form deformation (MM-FD) has been developed. MM-FD views each p ...
Full textLink to itemCite
ConferenceMed Phys · June 2014
PURPOSE: To expedite on-board volumetric image reconstruction from limited-angle kV-MV projections for intrafraction verification. METHODS: A limited-angle intrafraction verification (LIVE) system has recently been developed for real-time volumetric verifi ...
Full textLink to itemCite
ConferenceMed Phys · June 2014
PURPOSE: Synchronized moving grid is a promising technique to reduce scatter and ghost artifacts in cone beam computed tomography (CBCT). However, it requires 2 projections in the same gantry angle to obtain full information due to signal blockage by the g ...
Full textLink to itemCite
ConferenceMed Phys · June 2014
PURPOSE: To investigate the feasibility of using nanoparticle markers to validate liver tumor motion together with a deformation field map-based four dimensional (4D) cone-beam computed tomography (CBCT) reconstruction method. METHODS: A technique for lung ...
Full textLink to itemCite
ConferenceMed Phys · June 2014
PURPOSE: To evaluate the accuracy of a 3D patient specific QA tool by analysis of the results produced from associated software in homogenous phantom and heterogonous patient CT. METHODS: IMRT and VMAT plans of five test suites introduced by TG119 were cre ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: To evaluate the accuracy and sensitivity of a patient clinical objective IMRT QA tool using a 3D diode array. METHODS: A 3D QA device (Delta4, Scandidos Inc.) with 2 orthogonal diode array planes was used for IMRT QA. The diode spacing is 5mm in c ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: To study the feasibility of using a grid, shown previously to mitigate the scatter problem, to detect and correct geometric variations in flat-panel-based cone beam CT (CBCT) imaging. METHODS: The study was performed on the CBCT system of a Varian ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: To evaluate breathing irregularity induced error in CBCT-based patient positioning in lung SBRT and correlate the error with a measure of breathing variability. METHODS: The 4D extended cardiac-torso (XCAT) digital phantom was used to generate 10- ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: Correct MLC modeling is essential to the accurate IMRT delivery. Most TPSs use simplified models with parameters of leaf transmission (LT) and dynamic leaf gap (DLG). The common way to determine them is through extrapolation from measurements. In ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: To develop a respiration-phase-matched DTS technique to monitor moving targets, and to evaluate its accuracy for various imaging parameters and anatomical characteristics Methods: Conventional methods, registering on-board DTS(OB-DTS, reconstructe ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: To develop an on-board 4D-CBCT(OB-4D-CBCT) reconstruction technique using prior information and limited-angle projections for 4D inter/intra-fractional target verificationMethods: The OB-4D-CBCT at each phase is considered as a deformation of plan ...
Full textLink to itemCite
ConferenceMed Phys · June 2012
PURPOSE: To investigate the treatment of multiple brain metastases using stereotactic radiosurgery with single-isocenter volumetric modulated arc therapy (VMAT) compared with conventional multi-isocenter dynamic conformal arc therapy (DCAT) and three-dimen ...
Full textLink to itemCite
ConferenceMedical Physics · January 1, 2011
Purpose: To evaluate the dosimetric accuracy of a novel CBCT estimation method using prior information for use in adaptive radiotherapy (ART)‐based treatment of lung cancer patients. Methods: Patient planning CT or previous day's CBCT images are used as th ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Cone beam computed tomography (CBCT) provides wide scan coverage per rotation; however, its image quality is compromised due to large amounts of scatter. In this study, we performed detailed Monte Carlo (MC) simulations of a CBCT flat panel detect ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Recently we demonstrated the use of a 1‐D grid placed between the source and patient to directly reduce scatter, and correct the remaining scatter in cone‐beam computed tomography (CBCT). However, that technique required two 360° gantry rotations ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Current commercially available planning systems which utilize MC algorithm‐based final dose calculation in IMRT planning employ pencil‐beam algorithms in the optimization process. Consequently, dose coverage for SBRT lung plans can be quite non‐un ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: Graphics processing units (GPUs) can shorten cone‐beam volume reconstruction time significantly in comparison to CPUs. We evaluated Flat3D texture techniques to further enhance calculation efficiency. Methods: Typical reconstruction involves proce ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Introduction: We have demonstrated that cone beam CT (CBCT) image quality was substantially improved in terms of eliminating scatter related artifacts and enhancing contrast‐to‐noise ratio, using a 1D grid placed between the x‐ray source and the imaging ob ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To assess the accuracy and dosimetric implications of multi‐modality, online image‐guided localization methods, including intra‐modality 3D prostate ultrasound, cone beam CT (CBCT), implanted prostate markers and Calypso 4D localization for patien ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To develop a novel scatter reduction and correction method to improve the CBCT image quality for IGRT applications. Method and Materials: A one‐dimensional grid composed of lead with equal interspacing was positioned between the x‐ray source and t ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To investigate the clinical issues associated with the use of Monte Carlo‐based prospective planning for lung SBRT and spine SRS patients. Methods: Experimental verification of the iPlan v.4.1 MC photon beam algorithm (BrainLab) was performed usin ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To investigate limited‐angle imaging using orthogonal x‐ray systems, with regard to use for target positioning onboard external beam radiation therapy (EBRT) machines. Method and Materials: Image reconstruction was performed using projection data ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Any deviation between treated and planned volumes for 3‐D conformal therapy, such as IMRT, may cause an adverse clinical outcome. It is therefore critical to minimize all potential deviations using an on‐board (or real‐time) imaging procedure immediately p ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To investigate a method to convert the pixel values of DTS images to HU values with reference HU values from CT images. Method and Materials: This study included CT and DTS images of two phantoms (Catphan and a chest phantom) and three patients (p ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purposes: A research platform was developed for target verification using digital tomosynthesis (DTS). To verify its accuracy, a phantom study was conducted and several clinical cases were investigated. Method and Materials: customer‐developed reconstructi ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To assess the impact of scan angles on the visibility of anatomy in on‐board digital tomosynthesis (DTS) images as a means to optimize this technique. Method and Materials: Head and neck cancer patients undergoing intensity‐modulated radiotherapy ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Digital Tomosynthesis (DTS) is a quasi‐3D imaging technique which reconstructs images from a limited angle of on‐board projections with significantly lower dose and shorter acquisition time than full cone‐beam CT (CBCT). However, DTS images recons ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To develop a new CT reconstruction algorithm based on Total‐Variation (TV) minimization. The new algorithm is specifically designed for limited angle reconstruction to alleviate volume information loss caused by incomplete projections. Method and ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: Automatic registration between reference and on‐board digital tomosynthesis (DTS) is a critical step for target localization using DTS. We previously developed an approximate method for automatic registration between reference and on‐board DTS, in ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To develop a workstation for clinical application of digital tomosynthesis (DTS) for real‐time target localization. Specifically, to accelerate the reconstruction both digitally‐reconstructed radiograph (DRR) and DTS using ultra‐fast interpolation ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Digital tomosynthesis (DTS) is a fast, low‐dose method for reconstructing 3‐D slices from 2‐D cone‐beam x‐ray projection data acquired with limited source angulation (e.g., 40°). We previously developed a method for reconstructing reference DTS (R ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Digital tomosynthesis (DTS) is a method for reconstructing 3D images from cone‐beam projection data acquired with limited angulation (e.g., 40°) of an x‐ray source, and is much faster and lower dose than full cone‐beam CT (CBCT). We previously dev ...
Full textCite