ConferenceJournal of Physics Conference Series · January 1, 2024
A comprehensive 3D dosimetry system consisting of the ClearView™ 3D dosimeter, VistaScan™ optical CT scanner, and VistaAce™ analysis software is commercially available and has the potential to be a strong verification tool with widespread applications. The ...
Full textCite
ConferenceJournal of Physics Conference Series · January 24, 2022
We report our progress towards developing a clinical application of NIPAM kV-CBCT dosimetry. The goal is to develop a practical kV-MV isocenter verification test for which the measurement and analysis can be carried out quickly (within an hour), and that e ...
Full textCite
ConferenceJournal of Physics Conference Series · August 29, 2019
We investigated the feasibility of using N-isopropylacrylamide (NIPAM) dosimeters with x-ray CT to verify radiosurgery dose. Dosimeters were prepared at one facility and shipped to a second facility for irradiation. A simulation CT was acquired and plans p ...
Full textCite
ConferenceJournal of Physics Conference Series · August 29, 2019
The present study investigates a cost effective and practical non-telecentric optical-CT scanner developed for 3D dosimetry, the Duke Integrated-Lens Optical-CT scanner (DIOS). The DIOS system includes an upgraded light-collimating tank (the LC-tank) made ...
Full textCite
ConferenceJournal of Physics Conference Series · August 29, 2019
This work investigates a novel reusable radiochromic sheet developed as an economic film substitute or as a radiochromic bolus. The radiation-induced optical density (OD) change of the sheet is read-out with a commercial flat-bed optical scanner. An optimi ...
Full textCite
ConferenceJournal of Physics Conference Series · August 29, 2019
Stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) are among the most demanding of radiation therapy techniques in terms of requirements for high accuracy and conformality of treatment delivery. Compared to conventional treatmen ...
Full textCite
ConferenceJournal of Physics Conference Series · June 5, 2017
This work introduces the Duke Integrated-lens Optical Scanner (DIOS), a prototype optical-CT system designed for convenient and low-cost readout of PRESAGE 3D dosimeters. A key novelty of the DIOS is the incorporation of a multi-purpose light-collimating t ...
Full textCite
ConferenceJournal of Physics Conference Series · June 5, 2017
This work explores and demonstrates the feasibility of utilizing new 3D printing techniques to implement advanced micro radiation therapy for pre-clinical small animal studies. 3D printed blocks and compensators were designed and printed from a strong x-ra ...
Full textCite
ConferenceJournal of Physics Conference Series · June 5, 2017
Despite increasing use of stereotactic radiosurgery, whole brain radiotherapy (WBRT) continues to have a therapeutic role in a selected subset of patients. Selectively avoiding the hippocampus during such treatment (HA-WBRT) emerged as a strategy to reduce ...
Full textCite
ConferenceJournal of Physics Conference Series · June 5, 2017
To develop and apply a remote dosimetry protocol with PRESAGE® radiochromic plastic and optical-CT readout in the validation of MRI guided radiation therapy (MRgRT) treatments (MRIdian® by ViewRay®). Through multi-institutional collaboration we performed P ...
Full textCite
ConferenceJournal of Physics Conference Series · June 5, 2017
Recent years have witnessed a remarkable evolution in the techniques, capabilities and applications of 3D dosimetry. Initially the goal was simple: to innovate new techniques capable of comprehensively measuring and verifying exquisitely intricate dose dis ...
Full textCite
ConferenceMed Phys · June 2016
PURPOSE: To validate the use of a PRESAGE dosimeter as a method to quantitatively measure dose distributions of injectable brachytherapy based on elastin-like polypeptide (ELP) nanoparticles. PRESAGE is a solid, transparent polyurethane-based dosimeter who ...
Full textLink to itemCite
ConferenceMed Phys · June 2015
PURPOSE: Delta4 dosimetric software can be used to calculate DVH-based metrics for patient-specific quality assurance from measurements made by a Delta4 QA device. This study investigates the effectiveness of a novel transform method that transposes measur ...
Full textLink to itemCite
ConferenceJournal of Physics Conference Series · January 1, 2015
Micro-beam Radiation Therapy (MRT) is an experimental radiation therapy with provocative experimental data indicating potential for improved efficacy in some diseases. Here we demonstrated a comprehensive micro-beam verification method utilizing high resol ...
Full textCite
ConferenceJournal of Physics Conference Series · January 1, 2015
Radiochromic materials exhibit a colour change when exposed to ionising radiation. Radiochromic film has been used for clinical dosimetry for many years and increasingly so recently, as films of higher sensitivities have become available. The two principle ...
Full textCite
ConferenceJournal of Physics Conference Series · January 1, 2015
This study investigates a reusable PRESAGE® 3D dosimeter (Presage-RU), which would improve cost-effectiveness and facilitate wider implementation of comprehensive, high resolution 3D dosimetry. Small (1x1x4.5 cm) and large (8 cm diameter, 4.5 cm length) sa ...
Full textCite
ConferenceJournal of Physics Conference Series · January 1, 2015
Optical computed tomography (optical-CT) is a method for visualizing 3dimensional dose distributions in radiochromic dosimeters. Projection images are acquired by collimating a visible light point source into parallel-beam geometry and imaging differential ...
Full textCite
ConferenceMed Phys · June 2014
PURPOSE: To quantitatively evaluate a 3D patient specific QA tool using 2D film and 3D Presage dosimetry. METHODS: A brain IMRT case was delivered to Delta4, EBT2 film and Presage plastic dosimeter. The film was inserted in the solid water slabs at 7.5cm d ...
Full textLink to itemCite
ConferenceJ Phys Conf Ser · 2013
We describe a method to directly measure the radial dose and anisotropy functions of brachytherapy sources using polyurethane based dosimeters read out with optical CT. We measured the radial dose and anisotropy functions for a Cs-137 source using a PRESAG ...
Full textLink to itemCite
ConferenceJ Phys Conf Ser · 2013
Six base of skull IMRT treatment plans were delivered to Presage dosimeters within the RPC Head and Neck Phantom for quality assurance (QA) verification. Isotropic 2mm 3D data were acquired by optical-CT scanning with the DLOS system (Duke Large Optical-CT ...
Full textLink to itemCite
ConferenceJ Phys Conf Ser · 2013
Deformable 3D dosimeters have potential applications in validating deformable dose mapping algorithms. This study evaluates a novel deformable PRESAGE® dosimeter and its application toward validating the deformable algorithm employed by VelocityAI. The def ...
Full textLink to itemCite
ConferenceJ Phys Conf Ser · 2013
PRESAGE® is a solid radiochromic dosimeter consisting of a polyurethane matrix, a triarylmethane leuco dye, and a trihalomethane initiator. Varying the composition and/or relative amounts of these constituents can affect the dose sensitivity, post-irradiat ...
Full textLink to itemCite
ConferenceJ Phys Conf Ser · 2013
There is a pressing need for clinically intuitive quality assurance methods that report metrics of relevance to the likely impact on tumor control of normal tissue injury. This paper presents a preliminary investigation into the accuracy of a novel "transf ...
Full textLink to itemCite
ConferenceJ Phys Conf Ser · 2013
There is significant interest in delivering precisely targeted small-volume radiation treatments, in the pre-clinical setting, to study dose-volume relationships with tumor control and normal tissue damage. In this work we investigate the IGRT targeting ac ...
Full textLink to itemCite
ConferenceJ Phys Conf Ser · 2013
Six base of skull IMRT treatment plans were delivered to 3D dosimeters within the RPC Head and Neck Phantom for QA verification. Isotropic 2mm 3D data was obtained using the DLOS-PRESAGE system and compared to an Eclipse (Varian) treatment plan. Normalized ...
Full textLink to itemCite
ConferenceJ Phys Conf Ser · 2013
Stereotactic radiosurgery has become a widely used technique to treat solid tumors and secondary metastases of the brain. Multiple targets can be simultaneously treated with a single isocenter in order to reduce the set-up time to improve patient comfort a ...
Full textLink to itemCite
ConferenceMedical Physics · January 1, 2011
Purpose: To commission and characterize a novel small animal irradiator, the XRad225cx from Precision X‐Ray Inc. This system is capable of delivering both square and circular fields ranging in size from 1mm to 40mm. The combination of very small field size ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Radiochromic plastics have recently emerged which can yield 3D dose information over clinical volumes in high resolution. These dosimeters require a fast, accurate read‐out, and broad beam optical‐Computed‐Tomography (optical‐CT) systems have show ...
Full textCite
ConferenceMedical Physics · January 1, 2011
The critical importance of comprehensive treatment verification to patient safety is a topic of major current interest. The increase in complexity of modern treatments has created a direct need for correspondingly more sophisticated and comprehensive verif ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: To commission and benchmark a 3D dosimetry system for clinical use, in particular, for verification and commissioning of complex radiation treatments like VMAT, IMRT and gated treatments. The system is composed of two parts: a radiochromic plastic ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Three‐dimensional (3D) dosimetry systems are rapidly improving, and provide vastly more data and comprehensive QA than can be achieved with conventional dosimetry systems. New challenges emerge including how best to utilize this data. Here we pres ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Small field dosimetry is challenging that impacts patient specific QA in proton beam therapy due to detector size, aperture scattering and disequilibrium. Therefore, it is urgent to develop an accurate and efficient method to quantify the uncertai ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: To evaluate a formulation of PRESAGE® intended for proton therapy and to use it to compare measurements with calculations for a spot scanning pencil proton beam and a passively scattered proton beam.Methods: Two 7.5 cm high by 9.5 cm diameter cyli ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: Presently, there is no patient specific dosimetric QA for radiation treatment of moving targets. Here we present a patient specific QA protocol for verification of 4D dosimetry delivered to a moving target in SBRT of lung and liver tumors. Methods ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: Optical‐CT and optical‐ECT are techniques with unique capability for high‐resolution 3D imaging of structure and function in tissue samples up to 4cc. In particular, 3D vasculature structure and distribution of fluorescent bio‐markers (e.g. green‐ ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: To obtain the first co‐registered high resolution 3D images of an intact xenograft tumor showing (i) the vasculature network labeled with an absorbing vasculature contrast agent, and imaged with optical‐CT (ii) the distribution of red‐fluorescent‐ ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: Experimental verification of brachytherapy dose distributions, especially closer than 1 cm from the source, is very difficult with current dosimetry tools. PRESAGE, a 3D radio‐chromic plastic, has already shown promise in the realm of high energy ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: Radiotherapy can adversely impair the function of implantable devices such as pacemakers and implantable cardioverter‐defibrillators. Tolerable dose limits are manufacturer dependent, complicating protocol standardization for radiotherapy clinics. ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: The answer depends on both the dosimeter's energy response and energy spectrum at distance (point of measurement) from the source. The latter is object of this study. Method and Materials: The spectra in water were calculated with Monte Carlo code ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: This concept study quantifies the potential for normal tissue sparing in IMRT boost plans for cervical cancer by employing patient‐specific margins. Various PTV expansion margins are evaluated, including best‐case and standard‐case scenarios, whic ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: Recently, radiation treatment technology has out‐paced the advances in QA technology, and a critical gap has been created within the arc motion delivery systems such as Rapid Arc®, High Art®, and VMAT®. Gantry position, speed and MU rate create ex ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To investigate the application of a radiochromic plastic 3D dosimeter to the measurement of commissioning data in radiosurgery fields. Method and Materials: In order to measure total scatter factors, a single cylinder of a radiochromic plastic (PR ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: To investigate feasibility of high‐resolution three dimensional (3D) optical‐CT scanning of an anthropomorphic leuco‐dye doped radiochromic plastic dosimeter. Method and Materials: An anthropomorphic head phantom made out of PRESAGE™ (a leuco‐dye‐ ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: Novel 3D dosimetry techniques illustrate the urgent clinical need for tools for the comparison and visualization of dose data from various dosimeters. We present results from a collaborative effort to develop clinically useful methods to view, com ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Optical computed tomography (optical‐CT) and emission tomography (optical‐ECT) are new techniques with demonstrated potential for imaging structure and function (including gene expression) in unsectioned tissue samples. This work presents the firs ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Rind radiosurgery is a highly modulated technique that aims to treat the proliferative disease of ring‐enhancing intracranial lesions, and to reduce the dose to normal brain tissue when compared with conventional radiosurgery. This study aims to q ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: The potential of the PRESAGE™/Optical‐CT system as a comprehensive 3D dosimetry tool has been demonstrated. Detailed characterization of intra‐dosimeter uniformity, temporal stability, inter‐dosimeter reproducibility and robustness have yet to be ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: To quantify the intra‐fraction motion of the cervix at various time points during a course of external beam radiation therapy. Also to develop patient‐specific PTV margins that can account for the observed intra‐fraction motion for cervix patients ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: This work investigates the feasibility of verifying respiratory gated treatments using a new 3D dosimetry system consisting of a radiochromic plastic (PRESAGE™) with optical‐CT readout. Method and Materials: Three identical PRESAGE™ dosimeters (5c ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: The prescribed dose of an IMRT treatment plan may need to be scaled without changing any other parameters of the plan (e.g. relative fluence‐maps). Examples include changing the prescription as ordered by the physician, or rescaling the dose to av ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: PRESAGE is a novel radiochromic plastic which, in combination with optical‐CT imaging, has been shown to have outstanding potential for high‐resolution three‐dimensional (3D) dosimetry. Here, the first application of PRESAGE/optical‐CT to commissi ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: Evaluate the buildup cap used on OneDosePlus™ MOSFET dosimeters and study the field size, angular, and SSD dependency. Method and Materials: OneDosePlus (ODP) dosimeters are single use, pre‐calibrated MOSFETs used to measure entrance patient dose. ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: Practical tools for comprehensive three‐dimensional (3D) dosimetry are urgently needed. Here we evaluate a novel, in‐house, second‐generation optical‐computed tomography (optical‐CT) scanner for 3D‐dosimetry in PRESAGE™ dosimeters. Primary advanta ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: To assess the accuracy and practicality of using GAFCHROMIC® EBT Film in combination with an Epson flat‐bed scanner for the verification of advanced treatment techniques in radiation therapy. The combination of EBT with flat‐bed scanner may repres ...
Full textCite
ConferenceMedical Physics · January 1, 2007
Purpose: Evaluation of the radiation characteristics and performance of the DVS® implantable MOSFET dosimeter for typical and hypo‐fractionated protocols. Method and Materials: The commercially available DVS is calibrated for use in the range of 150–250 cG ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Digital tomosynthesis (DTS) is a fast, low‐dose method for reconstructing 3‐D slices from 2‐D cone‐beam x‐ray projection data acquired with limited source angulation (e.g., 40°). We previously developed a method for reconstructing reference DTS (R ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Optical CT technology has received much attention recently in the areas of 3D gel dosimetry and biological imaging, owing to its uniqueness in offering high contrast 3D images for optically transparent objects. In this work we evaluate the perform ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: This work explores the potential of optical‐computed and emission‐tomography (OCT/OET), when coupled with optical clearing techniques, for imaging aspects of biological structure and function for cancer research. OCT/OET are the optical analogues ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: Presage is a new radiochromic material with substantial promise as a practical and convenient 3D dosimeter. Here we investigate new formulations of PRESAGETM to determine formulations that have high sensitivity, high stability, and/or a ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: To assess the accuracy and practicality of using GAFCHROMIC® EBT Film in combination with an Epson flat‐bed scanner for the verification of advanced treatment techniques in radiation therapy. EBT is a new type of Gafchromic film with high sensitiv ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: The ability to image 3D global structure (e.g. microvasculature) and function (e.g. gene expression) in whole unsectioned tumors, in high‐resolution and with high‐contrast, is of significant present interest in cancer research. We have developed n ...
Full textCite
ConferenceMedical Physics · January 1, 2006
Purpose: At present, clinical dosimeters are limited to point or planar measurement, and hence do not provide the comprehensive 3D information ideal for verification of advanced delivery techniques. In this work we present a clinically viable 3D dosimetry ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: A pressing goal of modern radiation dosimetry is the development of effective and convenient three‐dimensional (3D) dosimetry systems that can measure and verify complex dose distributions. 3D dosimetry materials do exist but improvements would be ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: The development of advanced radiation treatment techniques such as IMRT has prompted an immediate need for a dosimetry system that can provide accurate and convenient measurement of complex three‐dimensional (3D) dose distributions. Gel dosimetry ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: To quantify the degree of normal organ motion due to the respiratory and cardiac cycles. Better definition of such motion may be useful in defining field margins and in assessing the utility of gating technologies. Method and Materials: Four healt ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Introduction: Radiographic film has been a mainstay for quality assurance procedures within radiation oncology departments. Prior to 3D conformal therapy, treatments were planned using kilovoltage portal films (simulator films). After the introduction of 3 ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: On line cone‐beam x‐ray CT is a promising technique for image‐guided‐radiation‐therapy (IGRT) by virtue of its ability to provide soft tissue contrast in 3D. IGRT enables correction for inter‐fraction set‐up error and organ motion, which can impro ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: This study introduces a new radiation therapy target localization technique using online digital tomosynthesis (DTS), a method for reconstructing 3‐D slices from 2‐D projection data acquired with limited source motion. By separating the visualizat ...
Full textCite
ConferenceMedical Physics · January 1, 2005
Purpose: Great interest exists at present in determining methods to image and understand tumor micro‐vasculature structure and how it can be perturbed by a variety of agents, including radiation and anti‐angiogenic drug therapies. Present methods including ...
Full textCite