Clinical Applications and Monte Carlo Validation of a fully integrated 3D dosimetry system

Conference Journal of Physics Conference Series · January 1, 2024 A comprehensive 3D dosimetry system consisting of the ClearView™ 3D dosimeter, VistaScan™ optical CT scanner, and VistaAce™ analysis software is commercially available and has the potential to be a strong verification tool with widespread applications. The ... Full text Cite

Feasibility of a Novel 3D Dosimetry System for Commissioning of Single Isocenter Multitarget SRS Treatment

Conference INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS · November 1, 2022 Link to item Cite

Development of a practical clinical application of NIPAM kV-CBCT dosimetry

Conference Journal of Physics Conference Series · January 24, 2022 We report our progress towards developing a clinical application of NIPAM kV-CBCT dosimetry. The goal is to develop a practical kV-MV isocenter verification test for which the measurement and analysis can be carried out quickly (within an hour), and that e ... Full text Cite

Preface

Conference Journal of Physics Conference Series · January 24, 2022 Full text Cite

End to End (E2E) Testing in Radiation Therapy

Conference MEDICAL PHYSICS · June 2020 Link to item Cite

Feasibility of radiosurgery dosimetry using NIPAM 3D dosimeters and x-ray CT

Conference Journal of Physics Conference Series · August 29, 2019 We investigated the feasibility of using N-isopropylacrylamide (NIPAM) dosimeters with x-ray CT to verify radiosurgery dose. Dosimeters were prepared at one facility and shipped to a second facility for irradiation. A simulation CT was acquired and plans p ... Full text Cite

Preface

Conference Journal of Physics Conference Series · August 29, 2019 Full text Cite

Welcome Message

Conference Journal of Physics Conference Series · August 29, 2019 Full text Cite

Preliminary characterization of the Duke Integrated-Lens Optical-CT scanner (DIOS)

Conference Journal of Physics Conference Series · August 29, 2019 The present study investigates a cost effective and practical non-telecentric optical-CT scanner developed for 3D dosimetry, the Duke Integrated-Lens Optical-CT scanner (DIOS). The DIOS system includes an upgraded light-collimating tank (the LC-tank) made ... Full text Cite

Preliminary investigation of a reusable radiochromic sheet for radiation dosimetry

Conference Journal of Physics Conference Series · August 29, 2019 This work investigates a novel reusable radiochromic sheet developed as an economic film substitute or as a radiochromic bolus. The radiation-induced optical density (OD) change of the sheet is read-out with a commercial flat-bed optical scanner. An optimi ... Full text Cite

SRS and SBRT and advanced dosimetry: Duke experiences

Conference Journal of Physics Conference Series · August 29, 2019 Stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) are among the most demanding of radiation therapy techniques in terms of requirements for high accuracy and conformality of treatment delivery. Compared to conventional treatmen ... Full text Cite

Enhancing Radiation Therapy Through Cherenkov Light-Activated Phototherapy from Clinical Megavoltage Treatment Beams

Conference International Journal of Radiation Oncology*Biology*Physics · October 2017 Full text Cite

A prototype optical-CT system for PRESAGE 3D dosimeter readout

Conference Journal of Physics Conference Series · June 5, 2017 This work introduces the Duke Integrated-lens Optical Scanner (DIOS), a prototype optical-CT system designed for convenient and low-cost readout of PRESAGE 3D dosimeters. A key novelty of the DIOS is the incorporation of a multi-purpose light-collimating t ... Full text Cite

Characterization of novel preclinical dose distributions for micro irradiator

Conference Journal of Physics Conference Series · June 5, 2017 This work explores and demonstrates the feasibility of utilizing new 3D printing techniques to implement advanced micro radiation therapy for pre-clinical small animal studies. 3D printed blocks and compensators were designed and printed from a strong x-ra ... Full text Cite

Treatment planning and 3D dose verification of whole brain radiation therapy with hippocampal avoidance in rats

Conference Journal of Physics Conference Series · June 5, 2017 Despite increasing use of stereotactic radiosurgery, whole brain radiotherapy (WBRT) continues to have a therapeutic role in a selected subset of patients. Selectively avoiding the hippocampus during such treatment (HA-WBRT) emerged as a strategy to reduce ... Full text Cite

How feasible is remote 3D dosimetry for MR guided Radiation Therapy (MRgRT)?

Conference Journal of Physics Conference Series · June 5, 2017 To develop and apply a remote dosimetry protocol with PRESAGE® radiochromic plastic and optical-CT readout in the validation of MRI guided radiation therapy (MRgRT) treatments (MRIdian® by ViewRay®). Through multi-institutional collaboration we performed P ... Full text Cite

Innovation and the future of advanced dosimetry: 2D to 5D

Conference Journal of Physics Conference Series · June 5, 2017 Recent years have witnessed a remarkable evolution in the techniques, capabilities and applications of 3D dosimetry. Initially the goal was simple: to innovate new techniques capable of comprehensively measuring and verifying exquisitely intricate dose dis ... Full text Cite

SU-F-T-10: Validation of ELP Dosimetry Using PRESAGE Dosimeter: Feasibility Test and Practical Considerations.

Conference Med Phys · June 2016 PURPOSE: To validate the use of a PRESAGE dosimeter as a method to quantitatively measure dose distributions of injectable brachytherapy based on elastin-like polypeptide (ELP) nanoparticles. PRESAGE is a solid, transparent polyurethane-based dosimeter who ... Full text Link to item Cite

SU-E-T-341: DVH-Based Comparison of True 3D Measurements to a Delta4 System.

Conference Med Phys · June 2015 PURPOSE: Delta4 dosimetric software can be used to calculate DVH-based metrics for patient-specific quality assurance from measurements made by a Delta4 QA device. This study investigates the effectiveness of a novel transform method that transposes measur ... Full text Link to item Cite

Verification of micro-beam irradiation

Conference Journal of Physics Conference Series · January 1, 2015 Micro-beam Radiation Therapy (MRT) is an experimental radiation therapy with provocative experimental data indicating potential for improved efficacy in some diseases. Here we demonstrated a comprehensive micro-beam verification method utilizing high resol ... Full text Cite

Radiochromic 3D Detectors

Conference Journal of Physics Conference Series · January 1, 2015 Radiochromic materials exhibit a colour change when exposed to ionising radiation. Radiochromic film has been used for clinical dosimetry for many years and increasingly so recently, as films of higher sensitivities have become available. The two principle ... Full text Cite

Characterization of a reusable PRESAGE® 3D dosimeter

Conference Journal of Physics Conference Series · January 1, 2015 This study investigates a reusable PRESAGE® 3D dosimeter (Presage-RU), which would improve cost-effectiveness and facilitate wider implementation of comprehensive, high resolution 3D dosimetry. Small (1x1x4.5 cm) and large (8 cm diameter, 4.5 cm length) sa ... Full text Cite

Investigation of a low-cost optical-CT system with minimal refractive index-matching fluid

Conference Journal of Physics Conference Series · January 1, 2015 Optical computed tomography (optical-CT) is a method for visualizing 3dimensional dose distributions in radiochromic dosimeters. Projection images are acquired by collimating a visible light point source into parallel-beam geometry and imaging differential ... Full text Cite

Deformable Dose Reconstruction With Biomechanical Registration: Validation in Low-Contrast Images

Conference International Journal of Radiation Oncology*Biology*Physics · September 2014 Full text Cite

SU-E-T-472: A Multi-Dimensional Measurements Comparison to Analyze a 3D Patient Specific QA Tool.

Conference Med Phys · June 2014 PURPOSE: To quantitatively evaluate a 3D patient specific QA tool using 2D film and 3D Presage dosimetry. METHODS: A brain IMRT case was delivered to Delta4, EBT2 film and Presage plastic dosimeter. The film was inserted in the solid water slabs at 7.5cm d ... Full text Link to item Cite

Evaluation of a New Reusable 3D Dosimeter

Conference MEDICAL PHYSICS · June 1, 2014 Link to item Cite

Towards comprehensive characterization of Cs-137 Seeds using PRESAGE® dosimetry with optical tomography.

Conference J Phys Conf Ser · 2013 We describe a method to directly measure the radial dose and anisotropy functions of brachytherapy sources using polyurethane based dosimeters read out with optical CT. We measured the radial dose and anisotropy functions for a Cs-137 source using a PRESAG ... Full text Link to item Cite

Comprehensive quality assurance for base of skull IMRT.

Conference J Phys Conf Ser · 2013 Six base of skull IMRT treatment plans were delivered to Presage dosimeters within the RPC Head and Neck Phantom for quality assurance (QA) verification. Isotropic 2mm 3D data were acquired by optical-CT scanning with the DLOS system (Duke Large Optical-CT ... Full text Link to item Cite

Preliminary investigation and application of a novel deformable PRESAGE® dosimeter.

Conference J Phys Conf Ser · 2013 Deformable 3D dosimeters have potential applications in validating deformable dose mapping algorithms. This study evaluates a novel deformable PRESAGE® dosimeter and its application toward validating the deformable algorithm employed by VelocityAI. The def ... Full text Link to item Cite

Customising PRESAGE® for diverse applications.

Conference J Phys Conf Ser · 2013 PRESAGE® is a solid radiochromic dosimeter consisting of a polyurethane matrix, a triarylmethane leuco dye, and a trihalomethane initiator. Varying the composition and/or relative amounts of these constituents can affect the dose sensitivity, post-irradiat ... Full text Link to item Cite

Evaluation of a clinically intuitive quality assurance method.

Conference J Phys Conf Ser · 2013 There is a pressing need for clinically intuitive quality assurance methods that report metrics of relevance to the likely impact on tumor control of normal tissue injury. This paper presents a preliminary investigation into the accuracy of a novel "transf ... Full text Link to item Cite

How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator?

Conference J Phys Conf Ser · 2013 There is significant interest in delivering precisely targeted small-volume radiation treatments, in the pre-clinical setting, to study dose-volume relationships with tumor control and normal tissue damage. In this work we investigate the IGRT targeting ac ... Full text Link to item Cite

The effect of motion on IMRT - looking at interplay with 3D measurements.

Conference J Phys Conf Ser · 2013 Six base of skull IMRT treatment plans were delivered to 3D dosimeters within the RPC Head and Neck Phantom for QA verification. Isotropic 2mm 3D data was obtained using the DLOS-PRESAGE system and compared to an Eclipse (Varian) treatment plan. Normalized ... Full text Link to item Cite

Investigating the reproducibility of a complex multifocal radiosurgery treatment.

Conference J Phys Conf Ser · 2013 Stereotactic radiosurgery has become a widely used technique to treat solid tumors and secondary metastases of the brain. Multiple targets can be simultaneously treated with a single isocenter in order to reduce the set-up time to improve patient comfort a ... Full text Link to item Cite

MO‐G‐BRB‐02: Commissioning a Small Animal Irradiator Using 2D and 3D Dosimetry Techniques

Conference Medical Physics · January 1, 2011 Purpose: To commission and characterize a novel small animal irradiator, the XRad225cx from Precision X‐Ray Inc. This system is capable of delivering both square and circular fields ranging in size from 1mm to 40mm. The combination of very small field size ... Full text Cite

SU‐E‐T‐133: A Method to Improve the Accuracy of Optical‐CT 3D Dosimetry by Correcting for Stray Light

Conference Medical Physics · January 1, 2011 Purpose: Radiochromic plastics have recently emerged which can yield 3D dose information over clinical volumes in high resolution. These dosimeters require a fast, accurate read‐out, and broad beam optical‐Computed‐Tomography (optical‐CT) systems have show ... Full text Cite

TU‐E‐BRA‐02: How Should We Verify Complex Radiation Therapy Treatments ?

Conference Medical Physics · January 1, 2011 The critical importance of comprehensive treatment verification to patient safety is a topic of major current interest. The increase in complexity of modern treatments has created a direct need for correspondingly more sophisticated and comprehensive verif ... Full text Cite

WE‐E‐BRB‐08: Commissioning and Benchmarking a 3D Dosimetry System for Clinical Use

Conference Medical Physics · January 1, 2011 Purpose: To commission and benchmark a 3D dosimetry system for clinical use, in particular, for verification and commissioning of complex radiation treatments like VMAT, IMRT and gated treatments. The system is composed of two parts: a radiochromic plastic ... Full text Cite

TU‐C‐BRB‐01: A Method to Determine Measured Dose‐Volume‐Histograms (DVH) in Patient from 3D Dose Measurement in Phantom

Conference Medical Physics · January 1, 2011 Purpose: Three‐dimensional (3D) dosimetry systems are rapidly improving, and provide vastly more data and comprehensive QA than can be achieved with conventional dosimetry systems. New challenges emerge including how best to utilize this data. Here we pres ... Full text Cite

SU‐E‐T‐88: 3D Dosimetry for Small Irregular Proton Fields Using a New PRESAGE® Dosimeter

Conference Medical Physics · January 1, 2011 Purpose: Small field dosimetry is challenging that impacts patient specific QA in proton beam therapy due to detector size, aperture scattering and disequilibrium. Therefore, it is urgent to develop an accurate and efficient method to quantify the uncertai ... Full text Cite

SU‐E‐T‐363: Investigation of PRESAGE® Dosimeters for Proton Therapy

Conference Medical Physics · January 1, 2011 Purpose: To evaluate a formulation of PRESAGE® intended for proton therapy and to use it to compare measurements with calculations for a spot scanning pencil proton beam and a passively scattered proton beam.Methods: Two 7.5 cm high by 9.5 cm diameter cyli ... Full text Cite

SU‐E‐T‐99: A Patient Specific QA Protocol for Verification of 4D Dosimetry

Conference Medical Physics · January 1, 2011 Purpose: Presently, there is no patient specific dosimetric QA for radiation treatment of moving targets. Here we present a patient specific QA protocol for verification of 4D dosimetry delivered to a moving target in SBRT of lung and liver tumors. Methods ... Full text Cite

TU‐E‐201C‐08: A Comprehensive Method for Optical ‐ Emission Computed Tomography

Conference Medical Physics · January 1, 2010 Purpose: Optical‐CT and optical‐ECT are techniques with unique capability for high‐resolution 3D imaging of structure and function in tissue samples up to 4cc. In particular, 3D vasculature structure and distribution of fluorescent bio‐markers (e.g. green‐ ... Full text Cite

TU‐E‐201C‐06: Imaging the Biological Structure and Characteristics of Model Tumors Using Optical Computed Transmission and Emission Tomography

Conference Medical Physics · January 1, 2010 Purpose: To obtain the first co‐registered high resolution 3D images of an intact xenograft tumor showing (i) the vasculature network labeled with an absorbing vasculature contrast agent, and imaged with optical‐CT (ii) the distribution of red‐fluorescent‐ ... Full text Cite

SU‐GG‐T‐363: 3D Dosimetric Verification of Ir‐192 HDR Brachytherapy Source Irradiation

Conference Medical Physics · January 1, 2010 Purpose: Experimental verification of brachytherapy dose distributions, especially closer than 1 cm from the source, is very difficult with current dosimetry tools. PRESAGE, a 3D radio‐chromic plastic, has already shown promise in the realm of high energy ... Full text Cite

TU‐C‐BRA‐01: Memorial to Lester Skaggs

Conference Medical Physics · January 1, 2010 Memorial to Lester Skaggs. © 2010, American Association of Physicists in Medicine. All rights reserved. ... Full text Cite

SU‐GG‐T‐371: Measurement of Dose to Pacemakers and Other Implantable Medical Devices

Conference Medical Physics · January 1, 2010 Purpose: Radiotherapy can adversely impair the function of implantable devices such as pacemakers and implantable cardioverter‐defibrillators. Tolerable dose limits are manufacturer dependent, complicating protocol standardization for radiotherapy clinics. ... Full text Cite

SU‐GG‐T‐362: Is Distance‐Dependent Energy Correction Needed for Dosimetric Measurements Surrounding Brachytherapy Sources?

Conference Medical Physics · January 1, 2010 Purpose: The answer depends on both the dosimeter's energy response and energy spectrum at distance (point of measurement) from the source. The latter is object of this study. Method and Materials: The spectra in water were calculated with Monte Carlo code ... Full text Cite

Normal Tissue Sparing with Patient-specific Margins in IMRT Boost Plans for Cervical Cancer

Conference International Journal of Radiation Oncology*Biology*Physics · November 2009 Full text Cite

SU‐FF‐J‐103: Concepts for Normal Tissue Sparing with Patient‐Specific Margins in IMRT Boost Treatments for Cervix

Conference Medical Physics · January 1, 2009 Purpose: This concept study quantifies the potential for normal tissue sparing in IMRT boost plans for cervical cancer by employing patient‐specific margins. Various PTV expansion margins are evaluated, including best‐case and standard‐case scenarios, whic ... Full text Cite

TU‐E‐304A‐06: A 3D Solution for Advanced Photon Arc Therapy Quality Assurance

Conference Medical Physics · January 1, 2009 Purpose: Recently, radiation treatment technology has out‐paced the advances in QA technology, and a critical gap has been created within the arc motion delivery systems such as Rapid Arc®, High Art®, and VMAT®. Gantry position, speed and MU rate create ex ... Full text Cite

TH‐D‐BRB‐03: The Application of a Novel Three Dimensional Dosimetry System to the Acquisition of Commissioning Data of Small Photon Fields

Conference Medical Physics · January 1, 2009 Purpose: To investigate the application of a radiochromic plastic 3D dosimeter to the measurement of commissioning data in radiosurgery fields. Method and Materials: In order to measure total scatter factors, a single cylinder of a radiochromic plastic (PR ... Full text Cite

SU‐FF‐I‐153: First Experience of High Resolution 3D Optical‐CT Scanning of An Anthropomorphic, Leuco‐Dye Doped, Radiochromic Plastic Dosimeter

Conference Medical Physics · January 1, 2009 Purpose: To investigate feasibility of high‐resolution three dimensional (3D) optical‐CT scanning of an anthropomorphic leuco‐dye doped radiochromic plastic dosimeter. Method and Materials: An anthropomorphic head phantom made out of PRESAGE™ (a leuco‐dye‐ ... Full text Cite

SU‐FF‐T‐482: Extension of An Informatics Architecture to Compare and Analyze 3D Dosimetric Data

Conference Medical Physics · January 1, 2009 Purpose: Novel 3D dosimetry techniques illustrate the urgent clinical need for tools for the comparison and visualization of dose data from various dosimeters. We present results from a collaborative effort to develop clinically useful methods to view, com ... Full text Cite

TU‐FF‐A4‐03: Improving the Accuracy of Optical‐Emission‐CT Imaging Through Application of a Non‐Uniform Attenuation Correction

Conference Medical Physics · January 1, 2008 Purpose: Optical computed tomography (optical‐CT) and emission tomography (optical‐ECT) are new techniques with demonstrated potential for imaging structure and function (including gene expression) in unsectioned tissue samples. This work presents the firs ... Full text Cite

SU‐GG‐T‐438: Rind Radiosurgery: Investigation of a Novel Radiation Therapy Technique for the Treatment of Intracranial Lesions

Conference Medical Physics · January 1, 2008 Purpose: Rind radiosurgery is a highly modulated technique that aims to treat the proliferative disease of ring‐enhancing intracranial lesions, and to reduce the dose to normal brain tissue when compared with conventional radiosurgery. This study aims to q ... Full text Cite

TU‐D‐AUD C‐02: An Investigation of the Consistency and Robustness of the PRESAGE/optical‐CT 3D Dosimetry System

Conference Medical Physics · January 1, 2008 Purpose: The potential of the PRESAGE™/Optical‐CT system as a comprehensive 3D dosimetry tool has been demonstrated. Detailed characterization of intra‐dosimeter uniformity, temporal stability, inter‐dosimeter reproducibility and robustness have yet to be ... Full text Cite

SU‐GG‐J‐28: An Investigation of Intra and Inter‐Fraction Motion in Cervical Cancer Patients

Conference Medical Physics · January 1, 2008 Purpose: To quantify the intra‐fraction motion of the cervix at various time points during a course of external beam radiation therapy. Also to develop patient‐specific PTV margins that can account for the observed intra‐fraction motion for cervix patients ... Full text Cite

TU‐FF‐A2‐06: The Verification of Respiratory‐Gated Radiation Treatments Using 3D Dosimetry Techniques

Conference Medical Physics · January 1, 2008 Purpose: This work investigates the feasibility of verifying respiratory gated treatments using a new 3D dosimetry system consisting of a radiochromic plastic (PRESAGE™) with optical‐CT readout. Method and Materials: Three identical PRESAGE™ dosimeters (5c ... Full text Cite

SU‐GG‐T‐153: Scaling the Prescription Dose: How Accurate Is the Varian Delivery System?

Conference Medical Physics · January 1, 2008 Purpose: The prescribed dose of an IMRT treatment plan may need to be scaled without changing any other parameters of the plan (e.g. relative fluence‐maps). Examples include changing the prescription as ordered by the physician, or rescaling the dose to av ... Full text Cite

SU‐GG‐T‐135: Evaluation of PRESAGE/optical‐CT 3D Dosimetry for Commissioning a Linac for IMRT

Conference Medical Physics · January 1, 2008 Purpose: PRESAGE is a novel radiochromic plastic which, in combination with optical‐CT imaging, has been shown to have outstanding potential for high‐resolution three‐dimensional (3D) dosimetry. Here, the first application of PRESAGE/optical‐CT to commissi ... Full text Cite

SU‐FF‐T‐98: Characterization of Buildup Effects in OneDosePlus MOSFET‐Based Dosimeters

Conference Medical Physics · January 1, 2007 Purpose: Evaluate the buildup cap used on OneDosePlus™ MOSFET dosimeters and study the field size, angular, and SSD dependency. Method and Materials: OneDosePlus (ODP) dosimeters are single use, pre‐calibrated MOSFETs used to measure entrance patient dose. ... Full text Cite

WE‐E‐AUD‐03: Characterization of a Novel, Fast, In‐House, CCD‐Based Optical‐CT Scanner for 3D Dosimetry in Radiochromic Dosimeters

Conference Medical Physics · January 1, 2007 Purpose: Practical tools for comprehensive three‐dimensional (3D) dosimetry are urgently needed. Here we evaluate a novel, in‐house, second‐generation optical‐computed tomography (optical‐CT) scanner for 3D‐dosimetry in PRESAGE™ dosimeters. Primary advanta ... Full text Cite

SU‐FF‐T‐208: Evaluation of a New Radiochromic Film/Flatbed Scanner System for Planar Clinical Dosimetry

Conference Medical Physics · January 1, 2007 Purpose: To assess the accuracy and practicality of using GAFCHROMIC® EBT Film in combination with an Epson flat‐bed scanner for the verification of advanced treatment techniques in radiation therapy. The combination of EBT with flat‐bed scanner may repres ... Full text Cite

WE‐E‐AUD‐04: Radiation Characteristics and Hypo‐Fractionation Dose Response for the DVS Implantable MOSFET Dosimeter

Conference Medical Physics · January 1, 2007 Purpose: Evaluation of the radiation characteristics and performance of the DVS® implantable MOSFET dosimeter for typical and hypo‐fractionated protocols. Method and Materials: The commercially available DVS is calibrated for use in the range of 150–250 cG ... Full text Cite

2726

Conference International Journal of Radiation Oncology*Biology*Physics · November 2006 Full text Cite

2875

Conference International Journal of Radiation Oncology*Biology*Physics · November 2006 Full text Cite

2885

Conference International Journal of Radiation Oncology*Biology*Physics · November 2006 Full text Cite

32

Conference International Journal of Radiation Oncology*Biology*Physics · November 2006 Full text Cite

TH‐C‐ValB‐04: Evaluation of the Quality of 3D‐3D Mutual Information (MI) Shared Between Reference and On‐Board DTS Images

Conference Medical Physics · January 1, 2006 Purpose: Digital tomosynthesis (DTS) is a fast, low‐dose method for reconstructing 3‐D slices from 2‐D cone‐beam x‐ray projection data acquired with limited source angulation (e.g., 40°). We previously developed a method for reconstructing reference DTS (R ... Full text Cite

SU‐FF‐T‐230: Evaluation of the Performance of An Optical CT Scanner

Conference Medical Physics · January 1, 2006 Purpose: Optical CT technology has received much attention recently in the areas of 3D gel dosimetry and biological imaging, owing to its uniqueness in offering high contrast 3D images for optically transparent objects. In this work we evaluate the perform ... Full text Cite

WE‐D‐330A‐02: Optical‐Computed‐and Emmission Tomography: Applications in Cancer Research

Conference Medical Physics · January 1, 2006 Purpose: This work explores the potential of optical‐computed and emission‐tomography (OCT/OET), when coupled with optical clearing techniques, for imaging aspects of biological structure and function for cancer research. OCT/OET are the optical analogues ... Full text Cite

SU‐FF‐T‐89: An Exploration of New Formulations for PRESAGETM 3D Dosimetry

Conference Medical Physics · January 1, 2006 Purpose: Presage is a new radiochromic material with substantial promise as a practical and convenient 3D dosimeter. Here we investigate new formulations of PRESAGETM to determine formulations that have high sensitivity, high stability, and/or a ... Full text Cite

SU‐FF‐T‐219: Evaluation of a Practical and Low Cost Gafchromic Film/flat‐Bed Scanner Combination for Planar Dosimetry

Conference Medical Physics · January 1, 2006 Purpose: To assess the accuracy and practicality of using GAFCHROMIC® EBT Film in combination with an Epson flat‐bed scanner for the verification of advanced treatment techniques in radiation therapy. EBT is a new type of Gafchromic film with high sensitiv ... Full text Cite

WE‐D‐330A‐01: 3D Optical Imaging of Tumor Microvasculature and Viable Cell Distribution

Conference Medical Physics · January 1, 2006 Purpose: The ability to image 3D global structure (e.g. microvasculature) and function (e.g. gene expression) in whole unsectioned tumors, in high‐resolution and with high‐contrast, is of significant present interest in cancer research. We have developed n ... Full text Cite

TU‐C‐224C‐02: A Practical and Accurate 3D Dosimetry System for Radiation Therapy

Conference Medical Physics · January 1, 2006 Purpose: At present, clinical dosimeters are limited to point or planar measurement, and hence do not provide the comprehensive 3D information ideal for verification of advanced delivery techniques. In this work we present a clinically viable 3D dosimetry ... Full text Cite

Assessment of Setup Accuracy for Prostate Radiotherapy using On-board Imaging and Cone Beam Computed Tomography

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

Online Digital Tomosynthesis (DTS): A Novel Technique for Improving Target Localization in Radiation Therapy

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

Intrafraction Organ Motion of the Normal Cervix

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

A Novel Method of Imaging Unperturbed Tumor Vasculature in 3D

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

PRESAGE - A Promising New Material for 3D Dosimetry

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

Combining Cardiac/Respiratory Gating to Minimize the Organ Motion Effect

Conference International Journal of Radiation Oncology*Biology*Physics · October 2005 Full text Cite

WE‐D‐T‐617‐01: Characterization of a New 3D Dosimetric Material “PRESAGE” TM

Conference Medical Physics · January 1, 2005 Purpose: A pressing goal of modern radiation dosimetry is the development of effective and convenient three‐dimensional (3D) dosimetry systems that can measure and verify complex dose distributions. 3D dosimetry materials do exist but improvements would be ... Full text Cite

SU‐FF‐T‐257: The Study of the Dosimetric Properties of ‘RadGel’, a New Dosimeter for Three‐Dimensional Gel Dosimetry

Conference Medical Physics · January 1, 2005 Purpose: The development of advanced radiation treatment techniques such as IMRT has prompted an immediate need for a dosimetry system that can provide accurate and convenient measurement of complex three‐dimensional (3D) dose distributions. Gel dosimetry ... Full text Cite

SU‐FF‐J‐30: Quantification of Normal Organ Motion Due to the Respiratory and Cardiac Cycles

Conference Medical Physics · January 1, 2005 Purpose: To quantify the degree of normal organ motion due to the respiratory and cardiac cycles. Better definition of such motion may be useful in defining field margins and in assessing the utility of gating technologies. Method and Materials: Four healt ... Full text Cite

WE‐E‐T‐6E‐01: Multidimensional Dosimetry Without Film Processors

Conference Medical Physics · January 1, 2005 Introduction: Radiographic film has been a mainstay for quality assurance procedures within radiation oncology departments. Prior to 3D conformal therapy, treatments were planned using kilovoltage portal films (simulator films). After the introduction of 3 ... Full text Cite

WE‐E‐J‐6C‐01: TOMAS, a Tool for Organ Motion AnalysiS

Conference Medical Physics · January 1, 2005 Purpose: On line cone‐beam x‐ray CT is a promising technique for image‐guided‐radiation‐therapy (IGRT) by virtue of its ability to provide soft tissue contrast in 3D. IGRT enables correction for inter‐fraction set‐up error and organ motion, which can impro ... Full text Cite

SU‐FF‐J‐57: Digital Tomosynthesis for Verification of Radiation Therapy Positioning: Preliminary Results From a Kilovoltage On‐Board Imaging System

Conference Medical Physics · January 1, 2005 Purpose: This study introduces a new radiation therapy target localization technique using online digital tomosynthesis (DTS), a method for reconstructing 3‐D slices from 2‐D projection data acquired with limited source motion. By separating the visualizat ... Full text Cite

WE‐D‐I‐609‐05: Optical Imaging of Tumor Microvasculature in 3D

Conference Medical Physics · January 1, 2005 Purpose: Great interest exists at present in determining methods to image and understand tumor micro‐vasculature structure and how it can be perturbed by a variety of agents, including radiation and anti‐angiogenic drug therapies. Present methods including ... Full text Cite