Journal articleMed Phys · September 2020
Featured Work
PURPOSE: The purpose of this study was to investigate the feasibility of using fused deposition modeling (FDM) three-dimensional (3D) printer to generate radiation compensators for high-resolution (~1 mm) intensity-modulated radiation therapy (IMRT) for sm ...
Full textLink to itemCite
Journal articleInt J Radiat Oncol Biol Phys · April 1, 2019
Featured Work
PURPOSE: To demonstrate proof of principle of visualizing delivered 3-dimensional (3D) dose distribution using kilovoltage (kv) cone beam computed tomography (CBCT) mounted onboard a linear accelerator. We apply this technique as a unique end-to-end verifi ...
Full textLink to itemCite
Journal articleJ Appl Clin Med Phys · September 2018
Featured Work
The charge of AAPM Task Group 113 is to provide guidance for the physics aspects of clinical trials to minimize variability in planning and dose delivery for external beam trials involving photons and electrons. Several studies have demonstrated the import ...
Full textLink to itemCite
Journal articleMed Phys · November 2017
Featured Work
PURPOSE: To develop a novel remote 3D dosimetry protocol to verify Magnetic Resonance-guided Radiation Therapy (MRgRT) treatments. The protocol was applied to investigate the accuracy of TG-119 IMRT irradiations delivered by the MRIdian® system (ViewRay® , ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · December 7, 2010
Featured Work
The RadBall dosimeter is a novel device for providing 3-D information on the magnitude and distribution of contaminant sources of unknown radiation in a given hot cell, glovebox, or contaminated room. The device is presently under evaluation by the Nationa ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · December 7, 2010
Featured Work
Achieving adequate verification and quality-assurance (QA) for radiosurgery treatment of trigeminal-neuralgia (TGN) is particularly challenging because of the combination of very small fields, very high doses, and complex irradiation geometries (multiple g ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · December 7, 2010
Featured Work
Three-dimensional dose distributions from liquid brachytherapy were measured using PRESAGE(®) dosimeters. The dosimeters were exposed to Y-90 for 5.75 days and read by optical tomography. The distributions are consistent with estimates from beta dose kerne ...
Full textLink to itemCite
Journal articlePhys Med Biol · July 21, 2010
Featured Work
Optical-computed tomography (CT) and optical-emission computed tomography (ECT) are recent techniques with potential for high-resolution multi-faceted 3D imaging of the structure and function in unsectioned tissue samples up to 1-4 cc. Quantitative imaging ...
Full textLink to itemCite
Journal articlePhys Med Biol · April 21, 2010
Featured Work
This work presents an investigation into the use of PRESAGE dosimeters with an optical-CT scanner as a 3D dosimetry system for quantitative verification of respiratory-gated treatments. The CIRS dynamic thorax phantom was modified to incorporate a moving P ...
Full textLink to itemCite
Journal articlePhys Med Biol · March 7, 2010
Featured Work
Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-d ...
Full textLink to itemCite
Journal articlePhys Med Biol · March 7, 2010
Featured Work
Achieving accurate small field dosimetry is challenging. This study investigates the utility of a radiochromic plastic PRESAGE read with optical-CT for the acquisition of radiosurgery field commissioning data from a Novalis Tx system with a high-definition ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · 2010
Featured Work
A midsized broad beam Optical-CT scanner is being developed for collaborative research between Duke and the Radiological Physics Center (RPC). The Duke Midsized Optical-CT Scanner (DMOS-RPC) is designed to be compatible with several of the RPC phantoms, in ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · January 1, 2010
Featured Work
PURPOSE: To investigate the dosimetric properties of a new Presage formulation which exhibits a reversible color change on exposure to radiation. Presage(REU) offers the intriguing possibility of the first re-useable 3D dosimetry material. METHOD AND MATER ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · January 1, 2010
Featured Work
We describe initial experiences with an in-house, fast, large field-of-view optical-CT telecentric scanner (the Duke Large field of view Optical-CT Scanner (DLOS)). The DLOS system is designed to enable telecentric optical-CT imaging of dosimeters up to 24 ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · 2010
Featured Work
Optical-CT performed with a broad spectrum light source can lead to inaccurate reconstructed attenuation coefficients (and hence dose) due to 'spectral warping' as the beam passes through the dosimeter. Some wavelengths will be attenuated more strongly tha ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · 2010
Featured Work
INTRODUCTION: To develop and characterize the accuracy and reproducibility of a quad-phantom dosimeter which will serve as an independent verification tool during commissioning of a PRESAGE/optical-CT 3D dosimetry system. METHODS: A 16cm × 12cm cylindrical ...
Full textLink to itemCite
Journal articleMed Phys · July 2009
Featured Work
This study presents the application of the Presage/optical-CT 3D dosimetry system for relative dosimetry in the Radiologic Physics Center (RPC) Head and Neck (H&N) IMRT phantom. Performance of the system was evaluated by comparison with the "gold-standard" ...
Full textLink to itemCite
Journal articleMed Phys · January 2009
Featured Work
This work presents extensive investigations to evaluate the robustness (intradosimeter consistency and temporal stability of response), reproducibility, precision, and accuracy of a relatively new 3D dosimetry system comprising a leuco-dye doped plastic 3D ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · 2009
Featured Work
An urgent requirement for 3D dosimetry has been recognized because of high failure rate (~25%) in RPC credentialing, which relies on point and 2D dose measurements. Comprehensive 3D dosimetry is likely to resolve more errors and improve IMRT quality assura ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · January 1, 2009
Featured Work
The potential of the PRESAGE™/Optical-CT system as a comprehensive 3D dosimetry tool has been demonstrated. The current study focused on detailed characterization of robustness (intra-dosimeter uniformity and temporal stability) and reproducibility (inter- ...
Full textLink to itemCite
Journal articlePhys Med Biol · October 7, 2008
Featured Work
Optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT) are new techniques for imaging the 3D structure and function (including gene expression) of whole unsectioned tissue samples. This work presents a method of imp ...
Full textLink to itemCite
Journal articleMed Phys · May 2008
Featured Work
Complex dose delivery techniques like intensity-modulated radiation therapy (IMRT) require dose measurement in three dimensions for comprehensive validation. Previously, we demonstrated the feasibility of the "PRESAGE/optical-computed tomography (CT)" syst ...
Full textLink to itemCite
Journal articleMed Phys · January 2008
Featured Work
This study introduces a charge coupled device (CCD) area detector based optical-computed tomography (optical-CT) scanner for comprehensive verification of radiation dose distributions recorded in nonscattering radiochromic dosimeters. Defining characterist ...
Full textLink to itemCite
Journal articleJ Biomed Opt · 2008
Featured Work
Optical computed tomography (optical-CT) and optical emission computed tomography (optical-ECT) are new techniques that enable unprecedented high-resolution 3-D multimodal imaging of tissue structure and function. Applications include imaging macroscopic g ...
Full textLink to itemCite
Journal articleMed Phys · August 2007
Featured Work
Digital tomosynthesis (DTS) is a fast, low-dose three-dimensional (3D) imaging approach which yields slice images with excellent in-plane resolution, though low plane-to-plane resolution. A stack of DTS slices can be reconstructed from a single limited-ang ...
Full textLink to itemCite
Journal articlePhys Med Biol · April 21, 2007
Featured Work
Optical emission computed tomography (optical-ECT) is a technique for imaging the three-dimensional (3D) distribution of fluorescent probes in biological tissue specimens with high contrast and spatial resolution. In optical-ECT, functional information can ...
Full textLink to itemCite
Journal articleJ Biomed Opt · 2007
Featured Work
We explore the potential of optical computed tomography (optical-CT) and optical emission computed tomography (optical-ECT) in a new area-whole organ imaging. The techniques are implemented on an in-house prototype benchtop system with improved image quali ...
Full textLink to itemCite
Journal articleMed Phys · October 2006
Featured Work
There is a pressing need for a practical three-dimensional (3D) dosimetry system, convenient for clinical use, and with the accuracy and resolution to enable comprehensive verification of the complex dose distributions typical of modern radiation therapy. ...
Full textLink to itemCite
Journal articleMed Phys · September 2006
Featured Work
The physical basis and preliminary applications of optical computed tomography (optical-CT) and optical emission computed tomography (optical-ECT) are introduced, as new techniques with potential to provide unique 3D information on a variety of aspects of ...
Full textLink to itemCite
Journal articleMed Phys · May 2006
Featured Work
The development of intensity-modulated radiotherapy (IMRT) has created a clear need for a dosimeter that can accurately and conveniently measure dose distributions in three dimensions to assure treatment quality. PRESAGE is a new three dimensional (3D) dos ...
Full textLink to itemCite
Journal articleInt J Radiat Oncol Biol Phys · May 1, 2006
Featured Work
PURPOSE: To generate on-board digital tomosynthesis (DTS) and reference DTS images for three-dimensional image-guided radiation therapy (IGRT) as an alternative to conventional portal imaging or on-board cone-beam computed tomography (CBCT). METHODS AND MA ...
Full textLink to itemCite
Journal articleSemin Radiat Oncol · April 2006
Featured Work
Oligometastases refer to metastases that are limited in number and location and are amenable to regional treatment. The majority of these metastases appear in the brain, lung, liver, and bone. Although the focus of interest in the past within radiation onc ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · 2006
Featured Work
The need for an accurate, practical, low-cost 3D dosimetry system is becoming ever more critical as modern dose delivery techniques increase in complexity and sophistication. A recent report from the Radiological Physics Center (RPC) (1), revealed that 38% ...
Full textLink to itemCite
Journal articleRadiother Oncol · June 2005
Featured Work
BACKGROUND AND PURPOSE: X-ray volumetric imaging system (XVI) mounted on a linear accelerator is available for image guidance applications. In preparation for clinical implementation, phantom and patient imaging studies were conducted to determine the irra ...
Full textLink to itemCite
Journal articleRadiother Oncol · June 2005
Featured Work
BACKGROUND AND PURPOSE: This paper presents efficient and generalized processes for the clinical application of on-line X-ray volumetric cone-beam CT imaging (XVI) to improve the accuracy of patient set-up in radiation therapy. XVI image-guided therapy is ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · April 2005
Featured Work
The limitations of conventional dosimeters restrict the comprehensiveness of verification that can be performed for advanced radiation treatments presenting an immediate and substantial problem for clinics attempting to implement these techniques. In essen ...
Full textLink to itemCite
Journal articleMed Phys · January 2005
Featured Work
The purpose of this work is to compare the efficacy of mathematical models in predicting the occurrence of radiotherapy-induced left ventricular perfusion defects assessed using single-photon emission computed tomography (SPECT). The basis of this study is ...
Full textLink to itemCite
Journal articleMed Phys · May 2004
Featured Work
There is a clear need for technology that enables accurate, high-resolution, three-dimensional (3D) measurement of intricate dose distributions associated with modern radiation treatments. A potential candidate has emerged in the form of water-equivalent " ...
Full textLink to itemCite
Journal articleRadiother Oncol · February 2004
Featured Work
BACKGROUND AND PURPOSE: The QA of intensity modulated radiotherapy (IMRT) dosimetry is a laborious task. The goal of this work is to evaluate the dosimetric characteristics of a new 2D diode array (MapCheck from Sun Nuclear Corporation, Melbourne, Florida) ...
Full textLink to itemCite
Journal articleJ Phys Conf Ser · 2004
Featured Work
The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to ...
Full textLink to itemCite
Journal articleMed Phys · April 2003
Featured Work
Comprehensive verification of the intricate dose distributions associated with advanced radiation treatments is now an immediate and substantial problem. The task is challenging using traditional dosimeters because of restrictions to point measurements (io ...
Full textLink to itemCite
Journal articleMed Phys · August 2001
Featured Work
We report investigations into the feasibility of generating radioactive oxygen (15O, a positron emitter, with half-life 2.05 min) using a tuned Elekta SL25 accelerator, for the end purpose of imaging tumor perfusion. 15O is produced by the "gamma, neutron, ...
Full textLink to itemCite
Journal articleMed Phys · July 2001
Featured Work
The increased intricacy of Intensity-Modulated-Radiation-Therapy (IMRT) delivery has created the need for a high-resolution 3D-dosimetry (three-dimensional) system capable of measuring and verifying the complex delivery. Present clinical methods are inadeq ...
Full textLink to itemCite
Journal articleBr J Radiol · September 2000
Featured Work
New, complex radiotherapy delivery techniques require dosimeters that are able to measure complex three-dimensional dose distributions accurately and with good spatial resolution. Polymer gel is an emerging new dosimeter being applied to these challenges. ...
Full textLink to itemCite
Journal articleMed Phys · August 2000
Featured Work
With the development of conformal radiotherapy, particularly intensity modulated radiation therapy (IMRT), there is a clear need for multidimensional dosimeters. A commercial polymerizing gel, BANG-2 gel (MGS Research, Inc., Guilford, CT), has recently bee ...
Full textLink to itemCite
Journal articlePhys Med Biol · April 2000
Featured Work
Polyacrylamide gels are a powerful tool to measure radiation dose by quantifying the NMR T2 relaxation times of the irradiated gel. The exploitation of these radiation sensitive gels in clinical radiotherapy requires accurate mapping of T2 values. This pap ...
Full textLink to itemCite
Journal articlePhys Med Biol · October 1999
Featured Work
It is well known that the experimental dosimetry of brachytherapy sources presents a challenge. Depending on the particular-dosimeter used, measurements can suffer from poor spatial resolution (ion chambers), lack of 3D information (film) or errors due to ...
Full textLink to itemCite
Journal articleInt J Radiat Oncol Biol Phys · September 1, 1999
Featured Work
PURPOSE: Intensity-modulated radiotherapy (IMRT) offers the potential to more closely conform dose distributions to the target, and spare organs at risk (OAR). Its clinical value is still being defined. The present study aims to compare IMRT with stereotac ...
Full textLink to itemCite
Journal articlePhys Med Biol · September 1999
Featured Work
A methodology for the constrained customization of coplanar beam orientations in radiotherapy treatment planning using an artificial neural network (ANN) has been developed. The geometry of the patients, with cancer of the prostate, was modelled by reducin ...
Full textLink to itemCite
Journal articlePhys Med Biol · August 1999
Featured Work
Few quantitative data are available on the kinetics of polymerization reactions in polymer gel (PAG) dosimeters and their long-term stability. Post-irradiation polymerization reactions have been found to continue for several weeks, posing questions regardi ...
Full textLink to itemCite
Journal articleRadiother Oncol · June 1999
Featured Work
BACKGROUND AND PURPOSE: Conformal radiotherapy of the prostate is an increasingly common technique, but the optimal choice of beam configuration remains unclear. This study systematically compares a number of coplanar treatment plans for four-field irradia ...
Full textLink to itemCite
Journal articlePhys Med Biol · February 1999
Featured Work
A methodology for the constrained customization of non-coplanar beam orientations in radiotherapy treatment planning has been developed and tested on a cohort of five patients with tumours of the brain. The methodology employed a combination of single and ...
Full textLink to itemCite
Journal articleBr J Radiol · October 1998
Featured Work
A retrospective treatment planning study was carried out in five patients to assess the effectiveness of conformal radiotherapy of the oesophagus. A two-phase conventional treatment plan was created for each patient, with a prescribed dose of 55 Gy. This p ...
Full textLink to itemCite
Journal articlePhys Med Biol · October 1998
Featured Work
A new method of calibrating gel dosimeters (applicable to both Fricke and polyacrylamide gels) is presented which has intrinsically higher accuracy than current methods, and requires less gel. Two test-tubes of gel (inner diameter 2.5 cm, length 20 cm) are ...
Full textLink to itemCite
Journal articlePhys Med Biol · August 1998
Featured Work
A treatment-planning case study has been performed on a patient with a medium-sized, convex brain tumour. The study involved the application of advanced treatment-plan optimization techniques to improve on the dose distribution of the 'standard plan' used ...
Full textLink to itemCite
Journal articleMed Phys · July 1998
Featured Work
A methodology for optimizing the beam directions in radiotherapy treatment planning has been developed and tested on a cohort of twelve prostate patients. An optimization algorithm employing a an objective cost function was used, based on beam's-eye-view v ...
Full textLink to itemCite
Journal articlePhys Med Biol · May 1998
Featured Work
BANG-gel dosimetry offers the potential for measuring the dose delivered by a radiotherapy treatment technique, in three dimensions, with high spatial resolution and good accuracy. The ability to measure comprehensively a 3D dose distribution is a major ad ...
Full textLink to itemCite
Journal articleBr J Radiol · July 1997
Featured Work
The effectiveness of conformal radiotherapy can ultimately only be assessed by the use of clinical trials. As large multicentre clinical trials become more widespread, methods of transferring patient and plan data between radiotherapy treatment planning sy ...
Full textLink to itemCite
Journal articleMed Phys · June 1997
Featured Work
There is currently much research interest in developing, evaluating, and verifying intensity-modulation techniques. Of particular interest is how well the delivery of intensity-modulated profiles can be simulated by planning algorithms, and how accurately ...
Full textLink to itemCite
Journal articlePhys Med Biol · October 1996
Featured Work
Highly conformal dose distributions can be created by the superposition of many radiation fields from different directions, each with its intensity spatially modulated by the method known as tomotherapy. At the planning stage, the intensity of radiation of ...
Full textLink to itemCite
Journal articleRadiother Oncol · December 1995
Featured Work
A treatment plan optimisation algorithm has been applied to 12 patients with early prostate cancer in order to determine the optimum beam-weights and wedge angles for a standard conformal three-field treatment technique. The optimisation algorithm was base ...
Full textLink to itemCite
Journal articleRadiother Oncol · October 1995
Featured Work
The aim of this study was to evaluate the relative merits of the coplanar field arrangements most frequently used for conformal radiotherapy of the prostate using dose-volume histograms and normal tissue complication probabilities (NTCPs). Twelve patients ...
Full textLink to itemCite
Journal articleBr J Radiol · August 1995
Featured Work
This paper describes the applications of an inverse planning optimization algorithm to the real clinical problem of prostate cancer. The algorithm has been designed to compute optimized beam-weights taking full account of three-dimensional spatial informat ...
Full textLink to itemCite
Journal articleRadiother Oncol · June 1995
Featured Work
A radiotherapy treatment plan optimisation algorithm has been applied to 48 prostate plans and the results compared with those of an experienced human planner. Twelve patients were used in the study, and 3-, 4-, 6- and 8-field plans (with standard coplanar ...
Full textLink to itemCite