Journal articleUltrasound Med Biol · June 2023
OBJECTIVE: A new visualization and recording method used to assess and quantitate autogenic high-velocity motions in myocardial walls to provide a new description of cardiac function is described. METHODS: The regional motion display (RMD) is based on high ...
Full textLink to itemCite
Journal articleUltrasound Med Biol · September 2020
The real time high frame rate (HFR) 2-dimensional ultrasound system, T5, at Duke University is capable of imaging at up to 1000 images per second for adult cardiac imaging. A method for detecting and visualizing the mechanical contraction fronts using HFR ...
Full textLink to itemCite
Journal articleUltrasound Med Biol · May 2019
Recently, we developed a high-frame-rate echocardiographic imaging system capable of acquiring images at rates up to 2500 per second. High imaging rates were used to quantify longitudinal strain parameters in patients with echocardiographically normal func ...
Full textLink to itemCite
Journal articleUltrasound Med Biol · November 2016
The study describes a novel algorithm for deriving myocardial strain from an entire cardiac cycle using high-frame-rate ultrasound images. Validation of the tracking algorithm was conducted in vitro prior to the application to patient images. High-frame-ra ...
Full textLink to itemCite
Journal articleIEEE Trans Ultrason Ferroelectr Freq Control · October 2015
We describe an advanced real-time high-speed echocardiographic system with live display while scanning. Images are acquired at rates up to 1000 per second for adult cardiac applications and are stored in computer memory. Images may be played back in slow m ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · October 2014
Piezoelectric micromachined ultrasound transducer (PMUT) matrix arrays were fabricated containing novel through-silicon interconnects and integrated into intracardiac catheters for in vivo real-time 3-D imaging. PMUT arrays with rectangular apertures conta ...
Full textCite
Journal articleCardiovascular revascularization medicine : including molecular interventions · May 2013
The Live Volumetric Imaging (LVI) catheter is capable of real-time 3D intracardiac echo (ICE) imaging, uniquely providing full volume sectors with deep penetration depth and high volume frame rate. The key enabling technology in this catheter is an integra ...
Full textCite
Journal articleThe Journal of the Acoustical Society of America · January 2011
A method is proposed which uses a lower-frequency transmit to create a known harmonic acoustical source in tissue suitable for wavefront correction without a priori assumptions of the target or requiring a transponder. The measurement and imaging steps of ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2010
Piezoelectric micromachined ultrasound transducers (pMUTs) are potentialcandidates for catheter-based ultrasound phased arrays. pMUTs consist of leadzirconate titanate (PZT) thin film membranes formed on silicon substrates andare operated in flexure mode b ...
Full textCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · September 24, 2010
Tissue velocity and attenuation inhomogeneities reduce ultrasound image quality in many patients. Over the years a number of methods have been developed to estimate the corrective delays necessary for phase aberration correction. Past methods were based on ...
Full textCite
Journal articleProgress in Biomedical Optics and Imaging Proceedings of SPIE · June 19, 2009
It is demonstrated that distortion of a non-linearly generated first harmonic transmit beam due to a near-field aberrator is reduced as transmit pressure is increased. The first harmonic transmit beam is then used as a source for correction of aberration. ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · November 2008
Piezoelectric micromachined ultrasound transducers (pMUTs) are a new approach for the construction of 2-D arrays for forward-looking 3-D intravascular (IVUS) and intracardiac (ICE) imaging. Two-dimensional pMUT test arrays containing 25 elements (5 x 5 arr ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · April 2008
Feature tracking was developed to efficiently compute motion measurements from volumetric ultrasound images. Prior studies have demonstrated the motion magnitude accuracy and computation speed of feature tracking. However, the previous feature tracking imp ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2007
We report on the performance characteristics of 2D pMUT arrays. 2D arrays suitable for diagnostic ultrasound imaging containing 81 elements were bulk micromachined in silicon substrates. The devices consisted of suspended PZT thin film membranes formed by ...
Full textCite
Journal articleJournal of biomedical optics · March 2007
Atherosclerotic and normal rabbit aorta samples show a marked difference in chemical composition governed by the water, lipid, and protein content. The strongly overlapping infrared absorption features of the different constituents, and the complexity of t ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · February 2007
Real-time, three-dimensional (RT3D) ultrasound allows video frame rate volumetric imaging. The ability to acquire full three-dimensional (3-D) image data in real-time is particularly helpful for applications such as cardiac imaging, which require visualiza ...
Full textCite
Journal articleProceedings IEEE Ultrasonics Symposium · December 1, 2006
Piezoelectric micromachined ultrasound transducers (pMUTs) have been fabricated and characterized in this work as a new approach for manufacture of 2D arrays for forward-looking 3D intravascular (IVUS) and intracardiac (ICE) imaging. Two-dimensional pMUT a ...
Full textCite
Journal articleAcademic radiology · May 2005
Rationale and objectivesReal-time tomographic reflection (RTTR) permits in situ visualization of tomographic images so that natural hand-eye coordination can be used directly during invasive procedures. The method uses a half-silvered mirror to me ...
Full textCite
Journal articleUltrasound in medicine & biology · February 2005
This study tested the ability of real-time 3-D (RT 3-D) echocardiography to detect and delineate regions of abnormal contraction (akinesia or dyskinesia) in a canine model of regional myocardial injury and to develop methods to simplify injury assessments. ...
Full textCite
Journal articleJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · August 2004
ObjectiveThe purpose of our study was to test the applicability of calculating the difference between left ventricular (LV) and right ventricular (RV) stroke volume (SV) for assessing the severity of aortic (Ao) regurgitation (AR) using a real-tim ...
Full textCite
Journal article2004 2nd IEEE International Symposium on Biomedical Imaging Macro to Nano · January 1, 2004
Volumetric ultrasound imaging opens the door to a variety of diagnostic and interventional investigations. A key to the utility of volumetric ultrasound imaging is the ability to produce high quality displays of the target in real time as data is acquired. ...
Full textCite
Journal articleJ Am Soc Echocardiogr · September 2003
BACKGROUND: Real-time 3-dimensional echocardiography (RT3DE) reliably determines intracardiac chamber volumes without left ventricular (LV) geometric assumptions, yet clinical assessment of contractile performance is often on the basis of potentially inacc ...
Full textLink to itemCite
Journal articleAm J Physiol Heart Circ Physiol · January 2003
We describe a novel functional imaging approach for quantitative analysis of right ventricular (RV) blood flow patterns in specific experimental animals (or humans) using real-time, three-dimensional (3-D) echocardiography (RT3D). The method is independent ...
Full textLink to itemCite
Journal articleLecture Notes in Computer Science · January 1, 2003
Real Time Tomographic Reflection (RTTR), permits in situ visualization of tomographic images, so that natural hand-eye coordination can be employed directly during invasive procedures. The method merges the visual outer surface of the patient with a simult ...
Full textCite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 2002
The process of designing an ultrasonic phased array benefits from the ability to quickly view the effects of transducer modifications. This is particularly important for sparse arrays, where small changes in element placement or symmetry can have large eff ...
Cite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 2002
Conventional B-mode echocardiography is commonly used to assess ventricular function, but it is inherently limited by its tomographic nature and operator dependence for obtaining standard views. Use of real-time three-dimensional ultrasound (RT3D) overcome ...
Cite
Journal articleNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · November 21, 2001
Removing atherosclerotic material without transecting the vessel wall is a common problem for vascular surgeons and interventional cardiologists. The goal of this project is to design and construct a device that uses evanescent optical waves for precise, c ...
Full textCite
Journal articleJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · November 2001
BackgroundThe accuracy of conventional 2-dimensional echocardiographic and Doppler techniques for the quantification of valvular regurgitation remains controversial. In this study, we examined the ability of real-time 3-dimensional (RT3D) echocard ...
Full textCite
Journal articleJ Cardiol · 2001
BACKGROUND: A novel imaging system has been introduced which uses a dedicated two-dimensional echo probe for rapid beam forming to scan a pyramidal volume in real time. Real-time volumetric echocardiography has the potential to determine accurate cardiovas ...
Link to itemCite
Journal articleJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · January 2001
Assessment of left ventricular (LV) volumes and mass is a critical element in the evaluation of patients with cardiovascular disease. However, most non-invasive methods used for the quantitative measurements of LV volume and mass have important intrinsic l ...
Full textCite
Journal articleEchocardiography · November 2000
The heart is a dynamic organ with complexities in its shape. As such, it places special demands on three-dimensional techniques for reconstruction. Real-time volumetric echocardiography, which is based on phased array and parallel processing principles to ...
Full textLink to itemCite
Journal articleThe Journal of the Acoustical Society of America · October 2000
A bistatic ultrasound imaging system is demonstrated that uses two 32-element linear phased array transducers oriented at an angle of 40 degrees to one another. The system simultaneously acquires and displays in real time one conventional backscatter image ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 2000
A novel ultrasound imaging system has been implemented using two 32-element linear phased array transducers oriented at an angle of 40 degrees to one another. The system simultaneously acquires and displays, in real time, a conventional backscatter image a ...
Full textCite
Journal articleThe American journal of cardiology · December 1999
Left ventricular (LV) volumes are important prognostic indexes in patients with heart disease. Although several methods can evaluate LV volumes, most have important intrinsic limitations. Real-time 3-dimensional echocardiography (RT3D echo) is a novel tech ...
Full textCite
Journal articleAm Heart J · May 1999
BACKGROUND: The asymmetry and complex shape of the right ventricle have made it difficult to determine right ventricular (RV) volume with 2-dimensional echocardiography. Three-dimensional cardiac imaging improves visualization of cardiac anatomy but is als ...
Full textLink to itemCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 1999
We report a new method for tracking tissue motion and blood flow in three dimensions (3-D) using successive volumetric ultrasound scans. The method is based on combining the concepts of feature tracking and 3-D correlation search to achieve a compromise be ...
Full textCite
Journal articleUltrasonic imaging · July 1998
Several methods for ultrasound tissue motion tracking and blood velocity estimation have been proposed and clinically applied. While providing valuable information to the clinician that was not obtainable from B-mode anatomical imaging, these methods still ...
Full textCite
Journal articleCirculation · May 19, 1998
BACKGROUND: The lack of a suitable noninvasive method for assessing right ventricular (RV) volume and function has been a major deficiency of two-dimensional (2D) echocardiography. The aim of our animal study was to test a new real-time three-dimensional ( ...
Full textLink to itemCite
Journal articleJournal of Cardiovascular Diagnosis and Procedures · January 1, 1998
Matrix array ultrasound is a medical imaging modality in which a 3D volume is scanned electronically without physically moving the transducer, permitting rapid continuous 3D scanning of the heart. Unlike reconstructive 3D ultrasound, which relies on physic ...
Cite
Journal articleProceedings of SPIE - The International Society for Optical Engineering · 1997
We present a new method for detecting and tracking tissue motion in 3D. The method is based on the concept of tracking speckle patterns in 3D using the sum absolute difference (SAD) technique. One potential application of this method is to study the 3D mot ...
Full textLink to itemCite
Journal articleIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · December 1, 1996
This article describes a new angle-independent method suitable for three-dimensional (3-D) blood flow velocity measurement that tracks features of the ultrasonic speckle produced by a pulse echo system. In this method, a feature is identified and followed ...
Full textCite
Journal articleProceedings of the IEEE Ultrasonics Symposium · December 1, 1996
A real time angular scatter imaging system has been implemented on the Duke phased array scanner. One 32 element linear phased array transducer is used as the transmit aperture, and a second 32 element array is used as the receiver. The receive array is po ...
Cite
Journal articleProceedings of SPIE the International Society for Optical Engineering · December 1, 1995
Matrix-array ultrasound is a new medical imaging modality that steers an ultrasound beam electronically in three dimensions. It is the first imaging modality that can view the heart in 3D in real time, making possible the `volumetricardiogram,' i.e., conti ...
Cite
Journal articleProceedings of SPIE the International Society for Optical Engineering · December 1, 1995
Matrix-array ultrasound produces real-time 3D images of the heart, by employing a square array of transducers to steer the ultrasound beam in three dimensions electronically with no moving parts. Other 3D modalities such as MR, MUGA, and CT require the use ...
Cite
Journal articleThe Journal of the Acoustical Society of America · July 1995
Ultrasound speckle has long been recognized as a noise source in diagnostic imaging. The advent of three-dimensional imaging and flow detection requires the characterization of the three-dimensional acoustical speckle pattern. Ultrasound data were acquired ...
Full textCite
Journal articleUltrasound in medicine & biology · January 1995
A receive beam-tracking technique is introduced for simultaneously measuring more than one dimension of an existing velocity vector in medical ultrasound. By using flexible beamforming and a conventional linear-array transducer, vectors can be measured at ...
Full textCite
Journal articleIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · January 1, 1994
A new type of real-time ultrasound imaging system has been developed. In contrast to conventional systems, which process only echoes scattered directly back from tissue to form an image, this system images tissue by displaying energy scattered at other ang ...
Full textCite
Journal articleThe Journal of the Acoustical Society of America · February 1993
A new optical transducer for the detection of acoustic pressure in the diagnostic ultrasound frequency range is described. This transducer is based on the modulation of an evanescent light field by the incident acoustic energy. Theoretical design considera ...
Full textCite
Journal articleProceedings of the IEEE · 1993
The mission of the National Science Foundation/Engineering Research Center for Emerging Cardiovascular Technologies is to lead discovery and innovation in custom-integrated electronics, sensors, systems design, and simulation to develop a new generation of ...
Full textCite
Journal articleUltrasonic imaging · July 1992
The design, fabrication and evaluation of two-dimensional transducer arrays are described for medical ultrasound imaging. A 4 x 32, 2.8 MHz array was developed to use new signal processing techniques for improved B-scan imaging including elevation focusing ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 1991
For pt.I see ibid., vol.38, no.2, p.100-8 (1991). The authors describe the design, application, and evaluation of parallel processing to the high-speed volumetric ultrasound imaging system. The scanner produces images analogous to an optical camera or the ...
Full textCite
Journal articleIEEE transactions on ultrasonics, ferroelectrics, and frequency control · January 1991
Transducer design and phased array beam steering are developed for a volumetric ultrasound scanner that enables the 3-D visualization of dynamic structures in real time. The authors describe the design considerations and preliminary evaluation of a high-sp ...
Full textCite
Journal articleProceedings of SPIE the International Society for Optical Engineering · January 1, 1991
A real time volumetric ultrasonic imaging system has been improved through the use of parallel processing in two dimensions. The imaging system uses pulse-echo phased array principles to steer a two-dimensional transducer array in a pyramidal scan format. ...
Cite
Journal articleEchocardiography · January 1991
The purpose of this article is to review new approaches to three-dimensional acquisition and presentation of echocardiographic data. New three-dimensional phased-array devices hold great promise for the development and application of new descriptors for le ...
Full textLink to itemCite
Journal articleProceedings of the Annual Conference on Engineering in Medicine and Biology · December 1, 1990
The research program of Unit 2.1A, Real-Time 3-D Ultrasonic Data Acquisition, of the National Science Foundation/Engineering Research Center (NSF/ERC) is described. The unit's overall objective is to develop noninvasive ultrasonic means to study and assess ...
Cite
Journal articleJournal of digital imaging · November 1990
A real time volumetric ultrasound imaging system has been developed for medical diagnosis. The scanner produces images analogous to an optical camera and supplies more information than conventional sonograms. Potential medical applications include improved ...
Full textCite
Journal articleProceedings of SPIE the International Society for Optical Engineering · July 1, 1990
A real time volumetric ultrasound imaging system has been developed for medical diagnosis. The scanner produces images analogous to an optical camera or the human eye and supplies more information than conventional sonograms. Potential medical applications ...
Full textCite
Journal articleUltrasonics Symposium Proceedings · December 1, 1989
An online signal-processing technique to reduce speckle noise in ultrasound images is described. In the imaging system, a focused piston transducer is divided into 32 sectors. In the receive mode, parallel signal processing arranges the sectors into eight ...
Cite
Journal articleUltrasonics · September 1988
We have previously reported initial clinical results of a novel blood velocity imaging technique utilizing a two-dimensional correlation search applied to consecutively acquired echoes. In this paper, we describe both the physical principles underlying thi ...
Full textCite
Journal articleUltrasonic imaging · July 1988
A new online signal processing technique is described to reduce speckle noise in ultrasound images. In the imaging system, a focused piston transducer is divided into thirty-two sectors. In the receive mode, parallel signal processing arranges the sectors ...
Full textCite
Journal articleJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · May 1988Full textCite
Journal articleUltrasound Quarterly · January 1, 1988
Development of “Duplex” Doppler systems has spurred an increasing interest in ultrasound analysis of vessel anatomy, pathology, and flow physiology. Numerous systems are available, utilizing a variety of different approaches in providing flow velocity and ...
Full textCite
Journal articleUltrasonics Symposium Proceedings · December 1, 1987
A velocity imaging technique is described which operates on the envelope-detected echo signal and uses a two-dimensional correlation search method. Several experiments were performed to define the potentials and limitations of this technique. The results i ...
Cite
Journal articleProceedings of SPIE the International Society for Optical Engineering · September 10, 1987
The degree of speckle reduction achievable by spatial and frequency compounding is a function of the rates of speckle pattern change induced by varying the imaging system’s illumination angle and acoustic frequency, respectively. We have measured these rat ...
Full textCite
Journal articleUltrasonics Symposium Proceedings · December 1, 1986
The rates of ultrasonic B-mode speckle pattern changes are measured as a function of changes in the imaging angle under a variety of experimental conditions. The results of these experiments were used to design an imaging system that optimizes speckle redu ...
Cite
Journal articleUltrasonic imaging · July 1986
Coherent speckle is a source of image noise in ultrasonic B-mode imaging. The use of multiple imaging frequencies has been suggested as a technique for speckle contrast reduction. This technique involves the averaging of images whose speckle patterns have ...
Full textCite
Journal articleJ Am Coll Cardiol · June 1986
A necessary percursor to real-time three-dimensional echocardiographic imaging is the ability to obtain multiple planes of acoustic data simultaneously. A new ultrasound imaging technique facilitates the display of two real-time orthogonal B-mode images (O ...
Full textLink to itemCite
Journal articleUltrasound in medicine & biology · March 1986
Conventional ultrasound imaging devices are designed based on the assumption of a homogeneous tissue medium of constant acoustic velocity = 1540 m/sec. However, the body consists of tissue layers of varying thicknesses and velocities which range from 1470 ...
Full textCite
Journal articleProc. SPIE - Int. Soc. Opt. Eng. (USA) · 1986
In order to design improved spatial compounding ultrasound scanning systems it is necessary to determine the correlation of speckle patterns as a function of aperture translation. The authors have conducted experiments measuring the speckle correlation as ...
Cite
Journal articleUltrasonics Symposium Proceedings · January 1, 1986
The authors have measured the rates of ultrasonic B-mode speckle pattern changes as a function of the change in center frequency of the transmitted acoustical pulse under a variety of experimental conditions. Experimental results agree with a previous theo ...
Full textCite
Journal articleProceedings of SPIE the International Society for Optical Engineering · June 11, 1985
The data acquisition rate in medical ultrasonic imaging devices is limited by the acoustic propagation velocity in the tissues. Typically in such machines the image lines are produced sequentially one line per transmitted pulse. A parallel processing schem ...
Full textCite
Journal articleThe Journal of the Acoustical Society of America · April 1984
The data acquisition rate in medical ultrasonic imaging devices is limited by the acoustic propagation velocity in the tissues. Typically in such machines the image lines are produced sequentially one line per transmitted pulse. A parallel processing schem ...
Full textCite
Journal articleUltrasound Med Biol · 1984
To test the hypothesis that pulsed Doppler ultrasound spectral properties of bounded fluid jets related to orifice size, in vitro examinations were performed using a hydraulic simulator (standpipe, compliant receiving chamber, and variable round orifice). ...
Full textLink to itemCite
Journal articleIEEE Trans. Biomed. Eng. (USA) · 1983
The principles and techniques of real-time imaging with phased array ultrasound scanners are reviewed. Topics include (1) the geometric optics of beam steering and focusing with a linear array in the transmit and receive modes; (2) limitations on image dat ...
Cite
Journal articleCirculation · February 1981
The capability of a pulsed Doppler flowmeter combined with a phased-array imaging system to measure volume flow was tested in vitro and in patients undergoing cardiac catheterization. The Doppler-phased-array system (DPA) was used to determine vessel diame ...
Full textLink to itemCite
Journal articleIEEE Transactions on Sonics and Ultrasonics · January 1, 1981
Time quantization errors in phased array systems can cause increased sidelobe amplitude, thereby limiting the dynamic range of the ultrasound system. A simulation program predicting the position and amplitude of these anomalous quantization error grating l ...
Full textCite
Journal articleIEEE transactions on sonics and ultrasonics · 1981
Time quantization errors in phased array systems can cause increased sidelobe amplitude, thereby limiting the dynamic range of the ultrasound system. A simulation program predicting the position and amplitude of these anomalous quantization error grating l ...
Cite
Journal articleClinical radiology · May 1980
Abdominal and obstetric applications of a dynamically focused phased array real time ultrasonic system are described. This work was performed utilising both the Thaumascan (two-dimensional, high resolution, actual time, ultrasound, multi-element array scan ...
Full textCite
Journal articleProceedings of SPIE the International Society for Optical Engineering · December 26, 1979
The current state of medical diagnostic ultrasound imaging is analyzed including discussions of present limitations and possible solutions of these problems. Ultrasound is unique in that tomographic images are formed from mechanical energy reflected from t ...
Full textCite
Journal articleIEEE Transactions on Sonics and Ultrasonics · 1979
In the design of phased linear array sector scanners for medical applications, it is important to preserve uniform response at each angle throughout the sector scan of plus or minus 45 degree . Examination of linear array transducers showed reduced transmi ...
Cite
Journal articleIEEE Transactions on Sonics and Ultrasonics · January 1, 1979
In the design of phased linear array sector scanners for medical applications, it is important to preserve uniform response at each angle throughout the sector scan of ± 45°. Examination of linear array transducers showed reduced transmit pressure and rece ...
Full textCite
Journal articleJournal of clinical ultrasound : JCU · December 1978
The physical principles and clinical applications of a high-resolution, dynamically focused phased-array real time ultrasound are described. Advantages of the real time technique include rapid survey capability, efficient selection of an appropriate tomogr ...
Full textCite
Journal articleStroke · 1978
Initial clinical results are reported from a new real time, 2-dimensional ultrasound scanner modified for adult cephalic applications. An optimized transducer design and the use of the dynamically focused phased array imaging system have resulted in ultras ...
Full textLink to itemCite
Journal articleIEEE Transactions on Sonics and Ultrasonics · January 1, 1978
Cost and complexity of phased array diagnostic ultrasound imaging systems is related to the number of parallel channels during both transmit and receive. If the total number of active elements within a given aperture is reduced so that fewer parallel chann ...
Full textCite
Journal articleAm J Med · July 1977
A two-dimensional ultrasound imaging system capable of producing high resolution, cross-sectional images of the heart in real-time has been developed. This system relies upon phased-array principles to rapidly steer and focus the ultrasound beam through th ...
Full textLink to itemCite
Journal articleCirculation · January 1977
Left ventricular wall motion was assessed in 105 consecutive patients both invasively, using biplane cineangiography, and noninvasively, by a real-time, phased-array, two-dimensional echocardiography system. Ventricular wall motion in five anatomic areas o ...
Full textLink to itemCite
Journal articleYale J Biol Med · 1977
This report describes the operating characteristics and initial clinical results of a new echocardiographic system that produces real-time, high resolution, cross-sectional images of the heart. This system relies upon phased-array principles to rapidly ste ...
Link to itemCite
Journal articleCirculation · November 1976
In order to define baseline descriptive criteria for the diagnosis of mitral valve prolapse with cross-sectional echocardiography, 49 patients undergoing catheterization were examined by a real-time, two-dimensional phased array echocardiographic imaging s ...
Full textLink to itemCite
Journal articleAm J Cardiol · October 1976
Standard M mode echocardiography and a new real time two dimensional echocardiographic imaging system were utilized to follow the progressive anatomic destruction of the tricuspid valve in a patient with bacterial endocarditis. The initial two dimensional ...
Full textLink to itemCite
Journal articleProceedings of SPIE the International Society for Optical Engineering · March 25, 1976
Ultrasound imaging of soft tissues places severe demands on the design of imaging systems because of the large range of echo amplitudes which may be encountered at any point in the body. Simple TGC curves are often inadequate in producing optimum gray scal ...
Full textCite
Journal articleCirculation · February 1976
A new two-dimensional ultrasound imaging system capable of producing high resolution tomographic images of the heart in real time has been developed. This system relies on phased array principles to rapidly steer the ultrasound beam through the structures ...
Full textLink to itemCite
Journal articleCirculation · February 1976
A new two-dimensional, real-time, high resolution ultrasound imaging system is described. This system uses a linear array of ultrasound transducers to generate tomographic images of the heart in a circular sector format. Phased array techniques allow rapid ...
Full textCite
Journal articleundefined · January 1, 1975
The relation of imaging speed and sensitivity to the nature of image processing and the degree to which parallel processing is employed are considered. The limitations imposed on image resolution and ambiguity by the use of a discretely sampled aperture ar ...
Full textCite
Journal articleExcerpta Medica Ics no 363 · January 1, 1975
This report describes the design considerations, performance characteristics and initial clinical results of a new, high-resolution, real-time, two-dimensional ultrasound sector scanner designed specifically for cardiac use. Such a system is unique as it r ...
Cite
Journal articleAcoust Hologr · January 1, 1975
Real-time imaaging system is described that relies on phased array principles to steer and focus the ultrasound beam in the near field of a linear array of ultrasound transducers. Underlying the development of this system were several design considerations ...
Full textCite
Journal articleSPIE Semin Proc · January 1, 1975
This report describes the design considerations, performance characteristics and initial clinical results of a new, high-resolution, real-time, two-dimensional ultrasound sector scanner designed specifically for cardiac use. Such a system is unique as it r ...
Cite
Journal articleAcoust Hologr · January 1, 1975
An electronically steered and focused multielement transducer array is used in an attempt to minimize acoustic aberrations caused by skull thickness variations. Aberrations like this have thus far limited practical utilization of B-mode scanners in clinica ...
Full textCite
Journal article · December 1, 1974
A new ultrasound imaging system which removes or substantially reduces many previous limitations has been developed. This imaging system is based on phased array principles rather than the usual mechanical positioning to scan the ultrasound beam through th ...
Cite
Journal article · January 1, 1974
A new ultrasound imaging system which removes or substantially reduces many previous limitations has been developed. This imaging system is based on phased array principles rather than the usual mechanical positioning to scan the ultrasound beam through th ...
Cite
Journal articleSPIE Semin Proc · January 1, 1974
A description is given of an ultrasound imaging system which permits visualization of two-dimensional cardiac anatomy in real time. This system relies on phased array principles rather than mechanical means to rapidly steer the ultrasound beam through the ...
Cite
Journal articleAcoust Hologr · January 1, 1972
Following is the continuation of the list of titles and authors: Experimental Holographic Acoustic Imaging System. By N. Booth and B. Saltzer. First-Arrival Seismic Holograms. By G. L. Fitspatrick. Analysis of Varius Ultrasonic Holographic Imaging Methods ...
Cite