ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · April 2, 2026
The simultaneous multi-energy capability of photon-counting detectors (PCDs) enables CT imaging with multiple contrast agents, which is particularly valuable for preclinical cancer studies such as photon-counting CT (PCCT) imaging of mouse models of head a ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · April 2, 2026
Respiratory motion remains a significant challenge in computed tomography (CT), especially in thoracic imaging. Realistic motion modeling is essential to reduce artifacts and facilitate accurate diagnostics; however, acquiring the high-quality 4DCT data ne ...
Full textCite
ConferenceLecture Notes in Computer Science · January 1, 2026
Accurate 3D modeling of human organs is critical for constructing digital phantoms in virtual imaging trials. However, organs such as the large intestine remain particularly challenging due to their complex geometry and shape variability. We propose CLAP, ...
Full textCite
ConferenceLecture Notes in Computer Science · January 1, 2026
We present a multimodal approach to open-vocabulary segmentation in medical imaging by training five modality-specific models using a unified architecture based on the SAT model. Each model is tailored to a specific imaging modality—CT, MRI, Ultrasound, Mi ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2025
Micro-CT imaging studies in mouse cancer models are vital for developing therapeutics. Multi-energy CT imaging with a photon-counting detector (PCD) improves material separation in cancer studies involving nanoparticle-based contrast agents and combination ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2025
Finite Element (FE) simulation has been extensively used in cardiac modeling due to its ability to replicate normal cardiac physiology and adapt to simulate various cardiac pathologies. As such, different FE cardiac models have been developed, but represen ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2025
Medical imaging simulation studies benefit from the use of virtual phantoms since they present a defined ground-truth to evaluate and optimize imaging devices and techniques. Currently, these phantoms are primarily morphologically focused, surface-based re ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2025
Positron emission tomography-computed tomography (PET-CT) is a frequently used multimodality imaging technique. PET scans utilize a radioactive tracer to record metabolic activity, and CT scans provide anatomical information through x-ray attenuation. The ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2025
Virtual imaging trials (VITs) are a crucial tool that have surfaced as an alternative to traditional clinical trials for the evaluation and optimization of medical imaging technologies. In VITs, a computational phantom is sent through software to simulate ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2025
Efforts have been made to perform quantitative perfusion assessment in interventional suites. It is a challenging goal, as there is no equipment for tomography such as x-ray computed tomography (CT) in the room. We develop a method called IPEN for intra-in ...
Full textCite
ConferenceProc SPIE Int Soc Opt Eng · February 2024
Parametric response mapping (PRM) is a voxel-based quantitative CT imaging biomarker that measures the severity of chronic obstructive pulmonary disease (COPD) by analyzing both inspiratory and expiratory CT scans. Although PRM-derived measurements have be ...
Full textLink to itemCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2024
Virtual Imaging Trials, known as VITs, provide a computational substitute for clinical trials. These traditional trials tend to be sluggish, costly, and frequently deficient in definitive evidence, all the while subjecting participants to ionizing radiatio ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2024
Virtual imaging trials of malignancies require realistic models of lesions. The purpose of this study was to create hybrid lesion models and associated tool incorporating morphological and textural realism. The developed tool creates a lesion morphology ba ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2024
Dynamic chest radiography (DCR) enables the evaluation of lung function based on changes in lung density, lung area, and diaphragm level due to respiration. The need for lung segmentation techniques for sequential chest images is growing. Thus, this study ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2024
Photon-counting CT (PCCT) is an emerging x-ray spectral imaging technology. There are several PCCT prototypes available for clinical and experimental applications. Despite many published results, objective quantitative evaluation of PCCT systems remains ch ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2024
Real-time brain perfusion would be highly beneficial to fully leverage interventional procedures such as endovascular thrombectomy in treating ischemic stroke. However, the existing standard of care is constrained due to the absence of intra-operative real ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2024
We develop the XCAT series of phantoms for medical imaging research. The phantoms model different individuals over various ages, heights, and weights, but a current drawback is they do not include small intestine variability. Each phantom has a small intes ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2023
Prediction of pleural invasion in lung cancer is crucial in planning appropriate operating procedures and can be assessed using dynamic chest radiography (DCR). However, this assessment is negatively affected by rib shadows in conventional images. The purp ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2023
Deep learning methods have performed superiorly to segment organs of interest from Computed Tomography images than traditional methods. However, the trained models do not generalize well at the inference phase, and manual validation and correction are not ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Organ segmentation of medical images is a key step in virtual imaging trials. However, organ segmentation datasets are limited in in terms of quality (because labels cover only a few organs) and quantity (since case numbers are limited). In this study, we ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Photon-counting CT (PCCT) is an emerging CT technology that uses photon-counting detectors (PCDs) to offer better spatial resolution, higher contrast, lower noise, and material-specific imaging as compared to conventional energy-integrating CT. To study th ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Cardiac CT imaging is invaluable in a variety of applications including non-invasive assessment of coronary artery calcifications, the ruling out of acute coronary artery syndrome, and the planning of valve replacement procedures. Newer applications includ ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Ventilatory impairment is detected as decreased changes in lung density during respiration in dynamic chest radiography (DCR). The purpose of this study was to determine optimum imaging conditions in pediatric DCR through a virtual imaging trial (VIT). An ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Many published studies use deep learning models to predict COVID-19 from chest x-ray (CXR) images, often reporting high performances. However, the models do not generalize well on independent external testing. Common limitations include the lack of medical ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
Research studies of artificial intelligence models in medical imaging have been hampered by poor generalization. This problem has been especially concerning over the last year with numerous applications of deep learning for COVID-19 diagnosis. Virtual imag ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2022
The aim of this study was to evaluate and optimize the imaging parameters of a new dual-source photon-counting CT (PCCT) scanner (NAEOTOM Alpha, Siemens Healthineers) for lung lesion radiomics using virtual imaging trials. Virtual patients (XCAT phantoms) ...
Full textCite
Conference2022 IEEE NSS Mic Rtsd IEEE Nuclear Science Symposium Medical Imaging Conference and Room Temperature Semiconductor Detector Conference · January 1, 2022
PEDIATRICS have increased tissue radio-sensitivity and longer potential lifespan when compared to adults. Therefore, their risk of developing health problems such as cancer per unit administered activity (AA) is significantly higher than adults [1] , empha ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
Tube current modulation (TCM) is routinely implemented in clinical CT imaging. By modifying the x-ray tube current as a function of patient attenuation, image quality can be made more consistent and radiation dose can be better managed. Optimal TCM setting ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
Radiomic features extracted from CT imaging can be used to quantitively assess COVID-19. The objective of this work was to extract and analyze radiomics features in RT-PRC confirmed COVID-19 cases to identify relevant characteristics for COVID-19 diagnosis ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
Medical images can vary due to differences in imaging equipment and conditions. This variability negatively can impact the consistency and accuracy of diagnostic processes. Hence, it is critical to decrease the variability in image acquisition to achieve c ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
COPD is the fourth leading cause of death in the United States. The structural and functional attributes of this disease can be assessed in vivo using computed tomography (CT). The value of quantitative CT has been demonstrated towards characterization and ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
TWe aimed to estimate respiratory changes in lung volumes (i"lung volume) using frontal and lateral dynamic chest radiography (DCR) by employing a convolutional neural network (CNN) learning approach trained and tested using the four-dimensional (4D) exten ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
Cardiovascular disease is a leading cause of death worldwide. Among all cardiovascular diseases, coronary artery disease (CAD) is a major contributor to mortality, accounting for approximately 10% of deaths per annum. Imaging techniques such as computed to ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
The accuracy and variability of quantifications in Computed Tomography Angiography (CTA) are affected by imaging parameters and patient attributes. While patient attributes cannot usually be altered for a scan, imaging parameters can be optimized to improv ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
Pulmonary impairments are observed as decreased changes in lung density during respiration on dynamic chest radiographs (DCR). To facilitate pulmonary function evaluation based on DCR, the present study was conducted to correlate respiratory changes in pix ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2021
We propose an automated framework to generate 3D detailed person-specific computational phantoms directly from patient medical images. We investigate the feasibility of this framework in terms of accurately generating patient-specific phantoms and the clin ...
Full textCite
Conference · December 2, 2020
Purpose. Radiologic procedures are recommended based on benefit-to-risk justification. In X-ray imaging, while the benefit is often immediate for the patient, the associated radiation burden risk is a longer-term effect. Such a temporal gap can bias the ju ...
Open AccessCite
Conference · December 2, 2020
PURPOSE
Virtual imaging trial is a unique framework that can greatly facilitate the assessment and optimization of imaging, by emulating the experiments using representative models of patients and scanners. This study aimed to impalement and demonstrate a ...
Cite
ConferenceJournal of Medical Physics · June 30, 2020
Purpose
The Medical Physics 3.0 initiative aims to enhance direct physicist involvement in clinical decision making to improve patient care. In this involvement, it is crucial to achieve effective and patient-specific radiation risk assessment. CT risk cha ...
Full textOpen AccessCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2020
In photon-counting CT, detector energy thresholds directly affect image quality attributes such as contrast and noise. The purpose of this study was to identify optimum energy thresholds using a comprehensive virtual clinical trial platform. The virtual tr ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2020
As medical imaging technologies continue to accelerate in complexity, application, and multiplicity of design choices and use features, they should ideally be evaluated and optimized through human clinical trials. However, such trials are often impossible ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2020
We aimed to investigate the feasibility of predicting pleural invasion or adhesion of lung cancers with dynamic chest radiography (DCR), using a four-dimensional (4D) extended cardiac-torso (XCAT) computational phantom. An XCAT phantom of an adult man (50< ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2019
This study modeled a framework for virtual human liver phantoms, focusing primarily on the intricate vascular networks that comprise the liver. Large vasculature was segmented from clinical liver perfusion images to ascertain a general starting point for t ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2019
Purpose To accurately segment organs from 3D CT image volumes using a 2D, multi-channel SegNet model consisting of a deep Convolutional Neural Network (CNN) encoder-decoder architecture. Method We trained a SegNet model on the extended cardiac-Torso (XCAT) ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2019
The Living Heart Model (LHM) was developed as part of the Living Heart Project by Dassault Systemes to provide a numerical finite element (FE) model of the human heart that accurately reproduces the normal cardiac physiology. We previously incorporated the ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2019
This study was performed to investigate the detection performance of trapped air in dynamic chest radiography using 4D extended cardiac-torso (XCAT) phantom with a user-defined ground truth. An XCAT phantom of an adult male (50th percentile in height and w ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2019
Estimating parameters of clinical significance, like coronary stenosis, accurately and precisely from cardiac CT images remains a difficult task as image noise and cardiac motion can degrade image quality and distort underlying anatomic information. The pu ...
Full textCite
Conference · November 27, 2018
PURPOSE
Ascertaining radiological procedure radiation burden is essential for justification, optimization, and personalization of the procedure. While the exact radiation risk for an individual exam is unknowable, various risk-related figures have been use ...
Cite
Conference · November 27, 2018
PURPOSE
Effective dose can efficiently integrate multiple organ dose values into a singular scalar value of radiation dose. The effective dose can also be calculated using dose length product (DLP) to effective dose conversion coefficients. The purpose of ...
Cite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2018
Although non-linear CT systems offer improved image quality over conventional linear systems, they disrupt certain assumptions of the dependency of noise and resolution on radiation dose that are true of linear systems. As such, simplistic phantoms do not ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2018
This study aimed to develop a simulation framework to synthesize accurate and scanner-specific Computed Tomography (CT) images of voxel-based computational phantoms. Two phantoms were used in the simulations, a geometry-based Mercury phantom and a "texture ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2018
In previous work, we generated computational breast phantoms by using a principal component analysis (PCA) or "Eigenbreast" technique. For this study, we sought to address resolution limitations in the previous synthesized breast phantoms by analyzing new ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2018
Despite much advancement, quantitative optimization of cardiac CT has remained an elusive challenge. The purpose of this study was to quantify the stenosis measurement variability introduced by the relative motion of coronary vessels in cardiac CT. Even wi ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2017
The purpose of this study was to provide patient-specific organ dose estimation based on an atlas of human models for twenty tomosynthesis and radiography protocols. The study utilized a library of 54 adult computational phantoms (age: 18-78 years, weight ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2017
This study aimed to estimate the organ dose reduction potential for organ-dose-based tube current modulated (ODM) thoracic CT with wide dose reduction arc. Twenty-one computational anthropomorphic phantoms (XCAT, age range: 27- 75 years, weight range: 52.0 ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2017
This study aimed to model virtual human lung phantoms including both non-parenchymal and parenchymal structures. Initial branches of the non-parenchymal structures (airways, arteries, and veins) were segmented from anatomical data in each lobe separately. ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2017
This work seeks to utilize a cohort of computational, patient-based breast phantoms and anthropomorphic lesions inserted therein to determine trends in breast lesion detectability as a function of several clinically relevant variables. One of the measures ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2017
To facilitate studies of measurement uncertainty in computed tomography angiography (CTA), we investigated the cardiac motion profile and resulting coronary artery motion utilizing innovative dynamic virtual and physical phantoms. The four-chamber cardiac ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2016
To facilitate rigorous virtual clinical trials using model observers for breast imaging optimization and evaluation, we demonstrated a method of defining statistical models, based on 177 sets of breast CT patient data, in order to generate tens of thousand ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2016
In computed tomography (CT), patient-specific organ dose can be estimated using pre-calculated organ dose conversion coefficients (organ dose normalized by CTDIvol, h factor) database, taking into account patient size and scan coverage. The conv ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2016
Currently computed tomography (CT) dosimetry relies on CT dose index (CTDI) and size specific dose estimates (SSDE). Organ dose is a better metric of radiation burden. However, organ dose estimation requires precise knowledge of organ locations. Regional i ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2016
In thoracic CT, organ-based tube current modulation (OTCM) reduces breast dose by lowering the tube current in the 120° anterior dose reduction zone of patients. However, in practice the breasts usually expand to an angle larger than the dose reduction zon ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2016
A realistic model of the anatomical texture from the pulmonary interstitium was developed with the goal of extending the capability of anthropomorphic computational phantoms (e.g., XCAT, Duke University), allowing for more accurate image quality assessment ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2016
Physicians rely on CT Perfusion (CTP) images and quantitative image data, including cerebral blood flow, cerebral blood volume, and bolus arrival delay, to diagnose and treat stroke patients. However, the quantification of these metrics may vary depending ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2015
Virtual clinical trials (VCT) can be carefully designed to inform, orient, or potentially replace clinical trials. The focus of this study was to demonstrate the capability of the sophisticated tools that can be used in the design, implementation, and perf ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2015
Contrast enhancement is a key component of CT imaging and offer opportunities for optimization. The design and optimization of new techniques however requires orchestration with the scan parameters and further a methodology to relate contrast enhancement a ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2015
Among the various metrics that quantify radiation dose in computed tomography (CT), organ dose is one of the most representative quantities reflecting patient-specific radiation burden.1 Accurate estimation of organ dose requires one to effectively model t ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2015
In Monte Carlo simulation of organ dose for a chest CT scan, many input parameters are required (e.g., half-value layer of the x-ray energy spectrum, effective beam width, and anatomical coverage of the scan). The input parameter values are provided by the ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2015
Portable x-ray examinations often account for a large percentage of all radiographic examinations. Currently, portable examinations do not employ automatic exposure control (AEC). To aid in the design of a size-specific technique chart, acrylic slabs of va ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2015
This work compares the visibility of spheres and simulated masses in 2D-mammography and tomosynthesis systems using human observer studies. Performing comparison studies between breast imaging systems poses a number of practical challenges within a clinica ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2014
Breast imaging is an important area of research with many new Techniques being investigated To further reduce The morbidity and mortality of breast cancer Through early detection. Computerized phantoms can provide an essential Tool To quantitatively compar ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · January 1, 2014
Previous fabrication of anthropomorphic breast phantoms has demonstrated Their viability as a model for 2D (mammography) and 3D (tomosynthesis) breast imaging systems. Further development of These models will be essential for The evaluation of breast x-ray ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · June 3, 2013
While great advances are made toward making highly realistic, surface models of the human anatomy, very little has been done to fill these bounded surfaces with models of anatomical texture. We propose a method whereby realistic anatomically-based computed ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging - Proceedings of SPIE · 2013
Physical phantoms are essential for the development, optimization, and clinical evaluation of x-ray systems. These phantoms are used for various tests such as quality assurance testing, system characterization, reconstruction evaluation, and dosimetry. The ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · May 4, 2012
Mammography is currently the most widely accepted tool for detection and diagnosis of breast cancer. However, the sensitivity of mammography is reduced in women with dense breast tissue due to tissue overlap, which may obscure lesions. Digital breast tomos ...
Full textCite
ConferenceMedical Physics · January 1, 2012
Purpose: To modify the digital XCAT phantom to include patient‐specific 3D lung tumor trajectories and demonstrate potential applications. Methods: An algorithm is developed to program the existing XCAT phantom to move according to recorded patient 3D lung ...
Full textCite
ConferenceMedical Physics · January 1, 2011
Purpose: To compare organ dose, effective dose, and dose conversion coefficients in adult CT estimated using three types of reference phantoms: (1) hermaphrodite mathematical phantom employed by the imPACT CT dose calculator, (2) reference male and female ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · December 1, 2010
Radiation-dose awareness and optimization in CT can greatly benefit from a dose- reporting system that provides radiation dose and cancer risk estimates specific to each patient and each CT examination. Recently, we reported a method for estimating patient ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · December 1, 2010
This paper describes an initial investigation into means for producing lower-cost CT scanners for resource limited regions of the world. In regions such as sub-Saharan Africa, intermediate level medical facilities serving millions have no CT machines, and ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · June 15, 2009
We previously proposed a three-dimensional computerized breast phantom that combines empirical data with the flexibility of mathematical models1. The goal of this project is to enhance the breast phantom to include a more detailed anatomy than currently vi ...
Full textCite
ConferenceProgress in Biomedical Optics and Imaging Proceedings of SPIE · May 14, 2008
The goal of this work is to create a detailed three-dimensional (3D) digital breast phantom based on empirical data and to incorporate it into the four-dimensional (4D) NCAT phantom, a computerized model of the human anatomy widely used in imaging research ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: We propose a simulation study to examine the feasibility of incorporating dual energy (DE) subtraction with digital tomosynthesis (DTS) to help reduce DTS reconstruction artifacts. Method and Materials: We have previously investigated the incorpor ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Modern IMRT plans have necessitated improved image localization techniques. In the lungs, internal target volumes (ITVs) are often generated from 4DCT images; however, the patient must be properly localized daily for this to work effectively. In t ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Radiotherapy treatment planning studies often require the use of large patient CT datasets to extract conclusions of statistical significance. However, due to various reasons such as difficulties in acquiring a larger set of CT scans and in segmen ...
Full textCite
ConferenceIEEE Nuclear Science Symposium Conference Record · January 1, 1999
Respiratory motion can cause artifacts in myocardial SPECT. We incorporate respiratory mechanics into the current 4D MCAT and into the next generation spline-based MCAT phantoms. In order to simulate respiratory motion in the current MCAT phantom, the geom ...
Full textCite
ConferenceIEEE Nuclear Science Symposium Conference Record · January 1, 1999
We study similarities between proposed methods for noise control in 4D gated myocardial perfusion SPECT reconstruction. Three methods have been proposed: Fourier filtering in four dimensions, space-time Gibbs priors in 4D MAP reconstruction, and Karhunen-L ...
Full textCite