Journal articleWorld Journal of Biology Pharmacy and Health Sciences · April 30, 2024
Asians are often thought to have a poor ability to predict their future risk of diabetes. We studied perceptions of Type 2 diabetes future risk in middle school and high school students. All students watched two short videos about Body Mass Index ...
Full textCite
Journal articleJournal of asthma and allergy · January 2023
PurposeThe aim of this paper is to use easily accessible smartphones as a straightforward means for physicians to objectively check Medical Device Inhaler (MDI) technique, without the need for additional devices. Additionally, we seek to assess th ...
Full textCite
Journal articleJournal of Advances in Medicine and Medical Research · December 1, 2022
Introduction: Over 5.6 million stroke survivors in the United States experience hemiparesis of the upper limb. Assistive devices are used to help regain upper limb functionality for affected individuals; however, existing devices are bulky, costly, ...
Full textCite
Journal articleJournal of Advances in Medicine and Medical Research · December 19, 2021
Aims: We present a pilot study to illustrate how the impact of vaping can be quickly and conclusively documented in a large population and appropriate subpopulations.
Methods: It has been predicted that with longer duration and higher frequen ...
Full textCite
Journal articlePloS one · January 2021
IntroductionThe innovative Pratt pouch could optimize dispensing nevirapine prophylaxis to HIV-exposed infants in pre-measured single dose pouches to increase completion of the full 6 week infant nevirapine regimen.Materials and methodsNi ...
Full textOpen AccessCite
Journal articleHealth and Technology · September 1, 2018
Engineering World Health (EWH) developed and executed a unique model to train biomedical technicians (BMET) in Rwanda, Honduras, and Cambodia. This model significantly decreased out-of-service equipment, one to two years after the training’s initiation, wh ...
Full textCite
Journal articleHealth and Technology · May 1, 2018
A substantial amount of equipment is out-of-service in the developing world. Out-of-service equipment limits access to important medical procedures. We measured the amount of out-of-service donated, purchased and loaned medical equipment and documented the ...
Full textCite
Journal articlePediatr Infect Dis J · September 2016
BACKGROUND: In developing countries, antiretroviral therapy provides life-saving treatment to HIV-positive women and their children before, during and after birth. However, supply chain challenges such as long distances, medication shortages and nonfacilit ...
Full textLink to itemCite
Journal articleThe open biomedical engineering journal · January 2016
IntroductionModern day antiretroviral therapy allows HIV+ pregnant women to lower the likelihood of viral transmission to their infants before, during, and after birth from 20-45% to less than 5%. In developing countries, where non-facility births ...
Full textOpen AccessCite
Journal articleMedicine · June 2015
Mother-to-child HIV transmission rates remain elevated in countries with high home birth rates. This risk can be dramatically reduced if infants receive antiretroviral (ARV) medication within 24 hours after birth. However, many barriers prevent access to t ...
Full textCite
Journal article · October 1, 2014
Medical imaging equipment can have tremendous clinical value, and is in great need in the developing world. Like all equipment, the most basic X-ray imaging systems require complex considerations to maintain quality, most notably maintenance and repair. Th ...
Full textCite
Journal articleJournal of Clinical Engineering · January 1, 2014
This article assesses the impact of a unique evidence-based biomedical equipment technician training program on the healthcare infrastructure and the productivity of technicians in Rwanda. Matched cohorts of hospitals included 9 technicians who received no ...
Full textCite
Journal articleJournal of Clinical Engineering · January 1, 2014
A midprogram assessment was conducted to determine if a continuing education program to instruct biomedical engineers in equipment repair and management is impacting healthcare in Honduras. A matched cohort study was conducted with 12 hospitals. Collected ...
Full textCite
Journal articleAnnals of biomedical engineering · September 2013
A new product has completed clinical trials in a distant, resource poor hospital using a few dozen prototypes. The data looks great. The novel medical device solves a widely felt problem. The next goal is to integrate the device into the country's healthca ...
Full textCite
Journal articleIet Conference Publications · December 1, 2012
The Developing World Healthcare Technology Laboratory (DHTLab) at Duke University recently developed the first evidence-based approach to training technicians to repair and maintain medical equipment in resource-poor settings, the BTA program. In this pape ...
Full textCite
Journal articleIet Conference Publications · December 1, 2012
The Developing World Healthcare Technology Laboratory (DHTLab) at Duke University has developed a comprehensive, open-source biomedical equipment technician's (BMET) library. In this work we experimented with making the DHTLab BMET library and medical equi ...
Full textCite
Journal articleThe open biomedical engineering journal · January 2012
Many children become HIV+ due to mother-to-child transmission, a risk that can be largely eliminated if infants ingest antiretroviral (ARV) medications immediately after birth. As most mothers in Africa deliver at home, the ARV must be provided at their la ...
Full textOpen AccessCite
Journal articleThe open biomedical engineering journal · January 2012
Biphasic defibrillation waveforms are now accepted as being more effective at terminating ventricular fibrillation (VF) than monophasic waveforms. If two phases are better than one, this naturally leads to the hypothesis that additional phases improve effi ...
Full textCite
Journal articleASEE Annual Conference and Exposition, Conference Proceedings · August 25, 2011
The Biomedical Engineering program at Duke University offers five distinct capstone design experiences for our seniors. This approach provides flexibility to serve the needs of our diverse student population, however a one semester experience can be limiti ...
Cite
Journal articleMedical & biological engineering & computing · July 2011
It is often said that most of the medical equipment in the developing world is broken with estimates ranging up to 96% out of service. But there is little documented evidence to support these statements. We wanted to quantify the amount of medical equipmen ...
Full textCite
Journal article2011 IEEE 37th Annual Northeast Bioengineering Conference Nebec 2011 · June 16, 2011
The developing world has a number of challenges regarding healthcare, such as insufficient training and funding to properly care for patients. One problem involves neonates that are born with Respiratory Distress Syndrome (RDS), which is a lack of surfacta ...
Full textCite
Journal articlePacing and clinical electrophysiology : PACE · May 2011
BackgroundA percutaneously placed, totally intravascular defibrillator has been developed that shocks via a right ventricular (RV) single-coil and titanium electrodes in the superior vena cava (SVC) and the inferior vena cava (IVC). This study eva ...
Full textCite
Journal articleHeart rhythm · February 2011
BackgroundAn intravascular, percutaneously placed implantable defibrillator (InnerPulse percutaneous intravascular cardioverter-defibrillator [PICD]) with a right ventricular (RV) single-coil lead and titanium electrodes in the superior vena cava ...
Full textCite
Journal articleMedical & biological engineering & computing · July 2010
Much of the laboratory and medical equipment in resource-poor settings is out-of-service. The most commonly cited reasons are (1) a lack of spare parts and (2) a lack of highly trained technicians. However, there is little data to support these hypotheses, ...
Full textCite
Journal articleIEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society · March 2010
Phototherapy is the standard treatment for severe cases of hyperbilirubinemia in newborns. Phototherapy exposes the infants to light in the range of 400-500 nm to isomerize unconjugated bilirubin in the skin. Any light source that produces this wavelength ...
Full textCite
Journal articleIet Seminar Digest · December 1, 2008
The Duke University-Engineering World Health Competition for Underserved Resources and Economies (Duke-EWH CUREs) promotes the development of new healthcare technologies and non-profit businesses to help the world's least developed nations. This paper desc ...
Full textCite
Journal articleASEE Annual Conference and Exposition, Conference Proceedings · December 1, 2008
Engineering World Health is a fusion of engineers, scientists and physicians donating their time and talents to improve healthcare in disadvantaged areas around the world. The Duke University-Engineering World Health (Duke-EWH) Summer Institute is a unique ...
Cite
Journal articleProceedings Frontiers in Education Conference Fie · December 1, 2007
Engineering educators and students are at the interface between biomedical engineering technology and the developing world. Through service learning efforts and organizations like Engineers Without Borders and Engineering World Health, engineers find thems ...
Full textCite
Journal articleIEEE Trans Biomed Eng · October 2007
Unintended, weak AC stimulation (leakage currents) from medical devices can cause blood pressure collapse and ventricular fibrillation (VF), potentially even death. Yet, little is understood about AC cardiac stimulation. The objective of this paper is to e ...
Full textLink to itemCite
Journal articlePhysiological measurement · August 2007
The 'Health for All by 2000' campaign included promotion of technologies that were known to be effective and inexpensive. The selected technologies were largely a failure. Among other problems, water pumps broke and could not be repaired in remote areas an ...
Full textCite
Journal articleAnnual review of biomedical engineering · January 2007
Approximately 20 years ago, the international community embarked on a project to bring health care to everyone by the year 2000 featuring, among other things, technologies that were known to be effective and economical. It was largely a failure. In fact, h ...
Full textCite
Journal articleProceedings of the IEEE Annual Northeast Bioengineering Conference Nebec · January 1, 2007
An x-ray detector will be designed for the Engineering World Health (EWH) organization to be incorporated into an ionizing radiation meter. This meter will be distributed to hospitals of the developing world to improve patient care. The meter will be able ...
Full textCite
Journal articleIEEE transactions on bio-medical engineering · October 2006
There is considerable work on defibrillation wave form optimization. This paper determines the impedance changes during defibrillation, then uses that information to derive the optimum defibrillation wave form.Methods part iTwelve guinea pigs and ...
Full textCite
Journal articleIEEE transactions on bio-medical engineering · August 2006
The efficacy of electrical therapy at terminating ventricular fibrillation is highly dependent on the waveform used. We present experimental results which test one theory for defibrillation waveform dependence. Forty-four defibrillation waveforms (22 monop ...
Full textCite
Journal articleAmerican Journal of Physics · April 1, 2006
Time varying magnetic fields can induce eddy currents in a conductor. Electrical currents also can be induced magnetically in the human body, and there has been considerable interest in the bioeffects of this phenomenon. We present an analytical model deri ...
Full textCite
Journal articleProceedings of the IEEE Annual Northeast Bioengineering Conference Nebec · January 1, 2006
Phototherapy by bililights is the gold standard used to provide treatment for jaundiced neonates. Jaundice is the accumulation of bilirubin in the blood which, if not treated in neonates, can lead to severe retardation and physical abnormalities. Since bil ...
Cite
Journal articlePhysiological measurement · February 2005
Cardiac mapping--recording cardiac activity during electrophysiological testing--has evolved into an indispensable tool in studying the cardiac excitation process, analysing activation patterns, and identifying arrhythmogenic tissue. Cardiac mapping is a b ...
Full textCite
Journal articleJournal of cardiovascular electrophysiology · April 2004
IntroductionEmpirical studies have shown that biphasic defibrillation waveforms are more efficacious than monophasic waveforms. However, a more systematic approach to waveform development might be more productive. This study tested 147 multiphasic ...
Full textCite
Journal articleIEEE transactions on bio-medical engineering · February 2004
While there is extensive mapping of the spread of electrical activity in the heart, there have been no measurements of electrical and localized mechanical, or contractile, activity. Yet the development of effective treatments for diseases like chronic hear ...
Full textCite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 2003
The renin-angiotensin-aldosterone system contributes to the pathophysiology of chronic heart failure. In this study, chronic heart failure is gradually induced in uninephrectomized rats (n = 4) by aldosterone infusion (0.75 μg/h) and high Na and low Mg die ...
Cite
Journal articleASEE Annual Conference Proceedings · December 1, 2003
Engineering World Health has partnered with The University of Memphis to create The Engineering World Health Summer Institute. This unique study abroad program offers students an opportunity to receive hands-on technical skills in a foreign country while e ...
Cite
Journal articleMedical & biological engineering & computing · November 2003
It is still unclear what fundamental criteria influence the ability of alternating current (AC) to induce ventricular fibrillation (VF) in vivo. As the VF threshold has a bowl-shaped relationship with frequency (showing a minimum threshold at some frequenc ...
Full textCite
Journal articleCirculation research · September 2003
Fatty acid oxidation (FAO) defects are inborn errors of metabolism clinically associated with cardiomyopathy and sudden infant death syndrome (SIDS). FAO disorders often present in infancy with myocardial dysfunction and arrhythmias after exposure to stres ...
Full textCite
Journal articleJournal of cardiovascular electrophysiology · August 2003
UnlabelledDefibrillation Causes Dilation.IntroductionPrior studies in isolated heart tissue have shown both excitation and deexcitation to be the primary mechanism of defibrillation. This article presents the first evidence in man of deex ...
Full textCite
Journal articleJournal of electrocardiology · April 2003
Cardiac arrhythmias are undesirable electrical activity in the heart. Ventricular fibrillation (VF) is a fatal cardiac arrhythmia and is characterized by the breakdown of organized electrical activity in the ventricular myocardium. However, little is known ...
Full textCite
Journal articleAmerican journal of physiology. Heart and circulatory physiology · March 2003
A previous two-dimensional (2D) ultrasound study suggested that there is relaxation of the myocardium after defibrillation. The 2D study could not measure activity occurring within the first 33 ms after the shock, a period that may be critical for discrimi ...
Full textCite
Journal articlePacing and clinical electrophysiology : PACE · February 2003
There have been few basic studies of alternating current (AC) defibrillation, despite growing interest in the ability of AC to terminate or alter ongoing fibrillation. Based on fibrillation threshold testing, it has been suggested that cardiac tissue is mo ...
Full textCite
Journal articleProgress in cardiovascular nursing · January 2003
T wave alternans is an electrocardiographic marker of myocardial electrical instability considered predictive for the development of lethal ventricular rhythms. Direct observation of this phenomenon on the electrocardiogram is rare. Subtle, nonvisible alte ...
Full textCite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 2002
A previous study has shown that the cross-sectional area of the left ventricular cavity (LV) increases immediately after defibrillation, suggesting that the defibrillation shock may cause relaxation. Since a single area slice may not reflect the entire myo ...
Cite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 2002
Medical equipment can unintentionally allow the flow of power line current through the patient causing complete hemodynamic collapse without fibrillation. This study tests the hypothesis that static wall thickening accompanies AC induced collapse via an is ...
Cite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 2002
Cardiac mapping has evolved into an important tool in the study, diagnosis, and treatment of cardiac arrhythmias and other heart disorders in both research and clinical settings. Traditionally, cardiac mapping systems have been used to measure the electric ...
Cite
Journal articlePhysiological measurement · May 2002
Finite element modelling of the heart for the purpose of studying the electric fields of defibrillation shocks requires knowledge of the geometry of the heart during fibrillation. However, the standard method of measuring this geometry, MRI. cannot be used ...
Full textCite
Journal articleJournal of cardiovascular electrophysiology · April 2002
IntroductionAn unknown mechanism causes defibrillation efficacy to be sensitive to the temporal pattern (waveform) of the delivered energy. Using a guinea pig model, we tested hypotheses in 140 defibrillation waveforms.Methods and results ...
Full textCite
Journal articleComputers in Cardiology · January 1, 2002
Optical mapping is commonly used to study ventricular fibrillation (VF). Electro-contractile uncouplers like 2,3 Butanedione Monoxime (BDM) are used in these studies to stop the mechanical activity, under the assumption that they do not have an effect on t ...
Full textCite
Journal articleComputers in Cardiology · January 1, 2002
There was a difference in the standard for leakage current in the US and Europe. This difference existed largely because there was very little data on AC stimulation of the heart in situ. In this study, we examine AC stimulation of the in tact guinea pig. ...
Cite
Journal articleComputers in Cardiology · January 1, 2002
Medical equipment can unintentionally allow the flow of small amounts of AC current through the patient causing hemodynamic collapse without fibrillation. This study examines the mechanical response of the left ventricle during AC induced hemodynamic colla ...
Cite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · January 1, 2002
The Engineering World Health Summer Institute is a unique educational paradigm. EWH is a study abroad program which offers students an opportunity to receive hands-on technical training while volunteering in a developing country and earning college credit. ...
Full textCite
Journal articleJournal of Modern Applied Statistical Methods · January 1, 2002
When investigators have N pairs of binary data, a common test for an increased rate of response is McNemar's test. However, McNemar's is an approximate, conditional test. An exact, unconditional test exists, but requires restrictive assumptions. Critical v ...
Full textCite
Journal articleJournal of cardiovascular electrophysiology · October 2001
IntroductionThe first study of weak alternating current (AC) stimulation in closed chest humans showed that complete hemodynamic collapse can occur below the threshold for inducing ventricular fibrillation (VF), a heretofore unknown danger to pati ...
Full textCite
Journal articleJournal of cardiovascular electrophysiology · October 2001
IntroductionThe goal of this study was to examine the effect of AC currents on a cardiac fiber. The study is the second in a series of two articles devoted to the subject. The initial study demonstrated that low-strength sinusoidal currents can ca ...
Full textCite
Journal articlePhysiological measurement · May 2001
We present a novel measurement for studying defibrillation mechanisms: the time course of changes in the size of the left ventricular (LV) cavity within 500 ms following defibrillation. Mechanical changes can be linked to electrical mechanisms via an under ...
Full textCite
Journal articleComputers in Cardiology · January 1, 2001
In this work we focus on the measurement of heart rate variability (HRV) from the murine plethysmograph. We check whether the recently proposed heart instantaneous frequency (HIF) idea is a viable tool to assess HRV under normal and the adverse conditions ...
Full textCite
Journal articleComputers in Cardiology · January 1, 2001
Different defibrillation waveforms exhibit different efficacies. It has been proposed that a resistor-capacitor (RC) model of the myocardial membrane can explain these differences. Both the maximum capacitor voltage (charge banking) and the remaining volta ...
Cite
Journal articleComputers in Cardiology · December 1, 2000
A new equivalent circuit model is proposed to quantify the defibrillation impedance for short pulses. Six male guinea pigs (850-1050g) were used. A defibrillator delivered square voltage pulses (200V). Three electrode placements were tested randomly: Norma ...
Cite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 2000
This figure summarizes the data showing the threshold for simulation (bold line), the minimum for VF (dotted line) and the average value for collapse. With the exception of one point (80Hz), there is always a point below the strength causing VF where AC st ...
Cite
Journal articleLab animal · October 2000
The authors discuss solubilized propofol, and demonstrate its acute use in guinea pigs as an effective, less expensive, easy-to-use alternative for laboratory animal anesthesia. ...
Full textCite
Journal articleIEEE transactions on bio-medical engineering · July 2000
Multielectrode arrays used to detect cellular activation have become so dense (electrodes per square millimeter) as to jeopardize the basic assumptions of activation mapping; namely, that electrodes are points adequately separated as to not interfere with ...
Full textCite
Journal articleAm J Physiol Heart Circ Physiol · July 2000
Cellular activation mapping (specifying in time and space the electrical activation sequence of cells) is a well-established basic research tool in cardiac, neural, and gastric physiology. Much recent research in cardiac mapping has focused on large arrays ...
Link to itemCite
Journal articleJournal of electrocardiology · July 2000
There is an upper limit to the vulnerability (ULV) of the ventricles to fibrillation (VF) induced by T-wave stimuli. Across species, disease states, and pharmacological treatments, the ULV is correlated to the defibrillation threshold (DF50). However, one ...
Full textCite
Journal articleAmerican journal of physiology. Heart and circulatory physiology · July 2000
Cellular activation mapping (specifying in time and space the electrical activation sequence of cells) is a well-established basic research tool in cardiac, neural, and gastric physiology. Much recent research in cardiac mapping has focused on large arrays ...
Full textCite
Journal articleLaboratory animal science · December 1999
Background and purposeGuinea pigs are used as models for study of ventricular tachyarrhythmias (VT); however, the tachyarrhythmia often is transient and does not persist. We developed an open-thorax guinea pig model of sustained ventricular fibril ...
Cite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 1999
A stimulus in the T-wave of the heart's normal cycle can alter the heart's activity. However, there is an upper limit (ULV) to stimulus strength that can cause conversion to ventricular fibrillation (VF). Since the ULV is correlated with the defibrillation ...
Cite
Journal articleComputers in Cardiology · December 1, 1999
In 1993, the American standard for leakage current through the heart under a single-fault condition was increased from 10 μA to 50 μA rms. Both the original 10 μA standard and the new 50 μA standard were based on estimates of the ability of 60 Hz AC curren ...
Cite
Journal articleJournal of cardiovascular electrophysiology · July 1999
IntroductionNew defibrillation techniques are often compared to standard approaches using the defibrillation threshold. However, inference from thresholding data necessitates extrapolation from reactions to relatively ineffective shocks, an error ...
Full textCite
Journal articleCirculation · May 1999
BackgroundThe national standard for safe 60-Hz intracardiac leakage current under a single-fault condition is 50 microA. This standard is intended to protect patients from alternating current (AC) at levels below the threshold for sensation, but t ...
Full textCite
Journal articleJournal of electrocardiology · April 1999
Recent studies have shown sustained tachyarrhythmias in guinea pigs. We hypothesized that guinea pigs could be used as a model of ventricular fibrillation, focusing on defibrillation waveform efficacy and the upper limit of vulnerability to fibrillation. I ...
Full textCite
Journal articleAmerican Industrial Hygiene Association Journal · March 1, 1999
In response to concerns about lead-based paint (LBP) in an 85-year old high school, an evaluation was conducted to determine whether a lead exposure hazard existed for adult school staff. Deteriorating LBP was present on walls and ceilings throughout the s ...
Cite
Journal articleJournal of electrocardiology · January 1999
Despite years of intense research into the mechanisms of defibrillation, there remain many unanswered questions. In many fields, hypotheses are first tested in rodent models before confirming the results in larger animals. This work suggests the guinea pig ...
Full textCite
Journal articleComputers in Cardiology · December 1, 1998
A strong stimulus delivered in the T-wave of a normal cardiac cycle can induce ventricular fibrillation. The critical point mechanism is thought to be responsible for this phenomenon. However, rapid pacing can cause an otherwise benign strong T-wave stimul ...
Cite
Journal articleComputers in Cardiology · December 1, 1998
Fluorescent Resonance Energy Transfer [FRET] is the transfer of excitation energy from a donor fluorescent molecule to an acceptor fluorescent molecule. FRET has been developed to achieve fast, ratiometric, transmembrane potential sensitive fluorescence ch ...
Cite
Journal articleJournal of cardiovascular electrophysiology · September 1998
IntroductionOur goal in this combined modeling and experimental study was to gain insight into the transmembrane potential changes in defibrillation conditions, namely, when shocks are delivered by an implantable cardioverter defibrillator (ICD). ...
Full textCite
Journal articlePacing and clinical electrophysiology : PACE · May 1998
When testing an ICD, there are at least two techniques for inducing ventricular fibrillation: (1) high frequency (approximately equal to 50 Hz) pacing; and (2) a single T wave stimulus. It is generally assumed that these two methods yield similar results. ...
Full textCite
Journal articleLaboratory animal science · February 1998
Guinea pigs are frequently used as models for ventricular tachyarrhythmias, including polymorphic ventricular tachycardia (VT) and ventricular fibrillation. However, applications of the model for short-term therapies are limited because the arrhythmias are ...
Cite
Journal articleIEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society · January 1998Full textCite
Journal articleComputers in Cardiology · December 1, 1997
This computational study examines the dependence of defibrillation threshold on the transvenous lead location in active-can transvenous lead defibrillation systems. Finite element models of the human thorax that incorporate (i) isotropic, (ii) realistic fi ...
Cite
Journal articleComputers in Cardiology · December 1, 1997
The American standard for AC current leakage in the myocardium was recently raised from 10 microamps to 50 microamps to match European standards. A lack of fibrillation (VF) induction data from humans has made it difficult to support or reject the increase ...
Cite
Journal articleComputers in Cardiology · December 1, 1997
This study aims at predicting the spatial extent of the polarization in myocardium (surface and in-depth patterns) resulting from bipolar current injection. The three-dimensional effects resulting from transmural fiber rotation and unequal anisotropy ratio ...
Cite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 1997
Guinea pigs are frequently used as models for ventricular tachyarrhythmias, including polymorphic ventricular tachycardia and ventricular fibrillation. However, applications of the model for the development of new cardioversion and defibrillation technolog ...
Cite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 1997
When an automatic defibrillator is implanted, it is essential to accurately estimate a highly effective defibrillation dose from a minimum number of fibrillation episodes. An optimum, fixed step-size, up-down Bayesian protocol has been previously proposed ...
Cite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 1997
Both experimental and modeling studies have shown that ventricular geometry plays a role in the efficacy of defibrillation shocks. This study uses transthoracic echocardiography to measure the temporal changes in the geometry of the right ventricle (RV) du ...
Cite
Journal articleMedical & biological engineering & computing · September 1997
A model study introduces the use of statistical signal processing to analyse the signals from an intracavitary probe. A complete derivation is given for the detection of one type of arrhythmogenic substrate, myocardial infarctions (MIs). Both the use of st ...
Full textCite
Journal articleJournal of cardiovascular electrophysiology · August 1997
IntroductionA stimulus delivered in the T wave of a paced cardiac cycle can induce ventricular fibrillation (VF). If the stimulus strength is increased, the probability of inducing VF decreases. This study determines an ideal mathematical model (a ...
Full textCite
Journal articlePacing and clinical electrophysiology : PACE · May 1997
In both the clinic and the laboratory, efficacy estimators are used to estimate the shock strength required to achieve a given defibrillation success rate. In the clinic, efficacy estimators are used to estimate highly effective doses (i.e., the shock stre ...
Full textCite
Journal articleComputers in Cardiology · December 1, 1996
A stimulus given in the T-wave (a ULV stimulus) of a paced cardiac cycle can induce ventricular fibrillation (VF). However, if the ULV stimulus strength is increased, the probability of inducing VF drops in a dose-response fashion. This paper presents a hy ...
Cite
Journal articleComputers in Cardiology · December 1, 1996
In a cardiac isochronal map, myocardial dynamics are represented by activation times. Traditionally, adhoc methods (typically using the local minimum derivative of à unipolar electrogram, i.e., minimum first derivative algorithm) are used to detect myocard ...
Cite
Journal articleIEEE transactions on bio-medical engineering · January 1996
It is frequently necessary, both clinically and in the laboratory, to estimate how strong a stimulus is required to defibrillate. Current techniques for forming such estimates require the repeated induction of ventricular fibrillation (VF) and subsequent a ...
Full textCite
Journal articleProceedings Frontiers in Education Conference · December 1, 1995
At the City College of New York, a project has been started to integrate student presentations into a sequence of three advanced undergraduate classes in engineering. Every undergraduate biomedical engineering student must take two of these three classes. ...
Cite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 1995
It is common to statistically test the hypothesis that one defibrillation technique is better than another. A standard approach is to estimate the DF50 (the shock strength which defibrillates 50% of the time) on a set of subjects under test and ...
Cite
Journal articleCirculation · September 1, 1995
BACKGROUND: The critical-point and upper-limit-of-vulnerability (ULV) hypotheses predict that the ULV dose-response curve should be steeper and to the right of the defibrillation (DF) curve. Yet, some recent experimental data contradict this prediction. Tw ...
Full textLink to itemCite
Journal articleCirculation · February 1995
BackgroundAn upper limit to the strength of shocks that induce fibrillation during the vulnerable period, the upper limit of vulnerability (ULV), has been shown to exist in both humans and animals. The purpose of this study was to compare ULV and ...
Full textCite
Journal articleAnnual International Conference of the IEEE Engineering in Medicine and Biology Proceedings · December 1, 1994
An implantable cardioverter-defibrillator (ICD) can prevent sudden cardiac death. However, the ICD stimulus strength must be set appropriately for each patient. Current protocols for estimating the appropriate stimulus strength require many attempts at def ...
Cite
Journal articleComputers in Cardiology · December 1, 1993
Small myocardial infarctions (MI) may be life threatening, but cannot be easily detected using standard, body surface electrocardiography. This model study explores the use of an intracavitary probe to detect small MI's. The likelihood ratio is used for de ...
Cite
Journal articleComputers in Cardiology · December 1, 1993
The spherical shells model (SSM) is a useful tool for qualitative investigations of the electrical events in the thorax during a heart beat. This paper presents a scheme to extend the SSM to allow for general dipolar source configurations. A model is sugge ...
Cite
Journal articleIEEE Journal of Oceanic Engineering · January 1, 1993
The unique environment of the abyssal plains allows many simplifying assumptions, facilitating the acoustic classification of an animal into one of two groups. The most important assumptions are based on low population densities and available target streng ...
Full textCite
Journal articleIEEE Trans. Biomed. Eng. (USA) · 1993
Minimum-squared-error (MinSE) testing protocols and a MinSE estimator that accurately estimate the voltage that defibrillates 95% of the time (the ED95) are presented. The MinSE experimental procedures, presented in the form of lookup tables, detail the re ...
Full textLink to itemCite
Journal articleProceedings ICASSP IEEE International Conference on Acoustics Speech and Signal Processing · January 1, 1993
An implanted cardioverter/defibrillator (ICD) detects ventricular fibrillation (VF), a potentially fatal lack of electrical coordination in the heart, and then discharges a capacitor through the heart, hopefully restoring normal rhythm. One of the clinical ...
Cite
Journal articleEnvironmental research · October 1992
Questions have been raised concerning the safety of mass burn incineration and its role in solid waste management. In 1989, the New York City Office of Occupational Safety and Health examined air levels of metals in New York City incinerators and found tha ...
Full textCite
Journal articleProceedings of the Annual Conference on Engineering in Medicine and Biology · December 1, 1991
Optimum Bayesian algorithms were compared with three currently used approaches to estimating the leading edge voltage which successfully defibrillates 95% of the time (ED95). Two different design methods were used for the Bayesian techniques. Five dogs wer ...
Cite
Journal articleProceedings of the Annual Conference on Engineering in Medicine and Biology · December 1, 1990
A signal-estimation theory approach to the problem of optimizing defibrillation thresholding techniques leading to an optimum stepping algorithm is presented. The results guarantee maximum average performance by achieving the minimum average cost. It is sh ...
Cite