Journal articleRadiother Oncol · May 2012
Featured Work
PURPOSE: To investigate (1) dosimetric differences between plans calculated using the anisotropic analytical algorithm (AAA) and pencil beam convolution (PBC) algorithm, (2) the plan quality achieved using AAA compared to PBC based on dosimetric parameters ...
Full textLink to itemCite
Journal articleMed Phys · April 2012
Featured Work
PURPOSE: Commercial CT-based image-guided radiotherapy (IGRT) systems allow widespread management of geometric variations in patient setup and internal organ motion. This document provides consensus recommendations for quality assurance protocols that ensu ...
Full textLink to itemCite
Journal articleInt J Radiat Oncol Biol Phys · January 1, 2012
Featured Work
PURPOSE: Several recent series evaluating external beam accelerated partial breast irradiation (PBI) have reported adverse cosmetic outcomes, possibly related to large volumes of normal tissue receiving near-prescription doses. We hypothesized that deliver ...
Full textLink to itemCite
Journal articleJournal of Applied Clinical Medical Physics · January 1, 2012
Featured Work
American Association of Physicists in Medicine (AAPM) task group (TG) 142 has recently published a report to update recommendations of the AAPM TG 40 report and add new recommendations concerning medical accelerators in the era of image-guided radiation th ...
Full textCite
Journal articleInt J Radiat Oncol Biol Phys · September 1, 2010
Featured Work
PURPOSE: To investigate the technical feasibility of volumetric modulated arc therapy (V-MAT) in the delivery of partial breast irradiation (PBI). METHODS AND MATERIALS: V-MAT and the standard, three-dimensional conformal radiotherapy (3D-CRT), were compar ...
Full textLink to itemCite
Journal articleInt J Radiat Oncol Biol Phys · March 1, 2010
Featured Work
PURPOSE: Dosimetric results and treatment delivery efficiency of RapidArc plans to those of conventional intensity-modulated radiotherapy (IMRT) plans were compared using the Eclipse treatment planning system for high-risk prostate cancer. MATERIALS AND ME ...
Full textLink to itemCite
Journal articleInt J Radiat Oncol Biol Phys · January 1, 2009
Featured Work
PURPOSE: To evaluate on-board digital tomosynthesis (DTS) for patient positioning vs. two-dimensional (2D) radiography and three-dimensional cone beam (CBCT). METHODS AND MATERIALS: A total of 92 image sessions from 9 prostate cancer patients were analyzed ...
Full textLink to itemCite
Journal articleInt J Radiat Oncol Biol Phys · March 15, 2008
Featured Work
PURPOSE: On-board cone-beam computed tomography (CBCT) provides soft tissue information that may improve setup accuracy in patients undergoing accelerated partial breast irradiation (APBI). We used CBCT to assess the residual error in soft tissue after two ...
Full textLink to itemCite
Journal articleInt J Radiat Oncol Biol Phys · December 1, 2006
Featured Work
PURPOSE: Cone-beam computed tomography (CBCT) images are currently used for positioning verification. However, it is yet unknown whether CBCT could be used in dose calculation for replanning in adaptive radiation therapy. This study investigates the dosime ...
Full textLink to itemCite
Journal articleMed Phys · November 2006
Featured Work
To develop a quality assurance (QA) program for the On-Board Imager (OBI) system and to summarize the results of these QA tests over extended periods from multiple institutions. Both the radiographic and cone-beam computed tomography (CBCT) mode of operati ...