Skip to main content

Sua Yoo

Associate Professor of Radiation Oncology
Radiation Oncology
Box 3295 Med Ctr, Durham, NC
Duke South Physics, Durham, NC

Featured Works


Comparison of 3D conformal breast radiation treatment plans using the anisotropic analytical algorithm and pencil beam convolution algorithm.

Journal article Radiother Oncol · May 2012 Featured Work PURPOSE: To investigate (1) dosimetric differences between plans calculated using the anisotropic analytical algorithm (AAA) and pencil beam convolution (PBC) algorithm, (2) the plan quality achieved using AAA compared to PBC based on dosimetric parameters ... Full text Link to item Cite

Quality assurance for image-guided radiation therapy utilizing CT-based technologies: a report of the AAPM TG-179.

Journal article Med Phys · April 2012 Featured Work PURPOSE: Commercial CT-based image-guided radiotherapy (IGRT) systems allow widespread management of geometric variations in patient setup and internal organ motion. This document provides consensus recommendations for quality assurance protocols that ensu ... Full text Link to item Cite

Preoperative single fraction partial breast radiotherapy for early-stage breast cancer.

Journal article Int J Radiat Oncol Biol Phys · January 1, 2012 Featured Work PURPOSE: Several recent series evaluating external beam accelerated partial breast irradiation (PBI) have reported adverse cosmetic outcomes, possibly related to large volumes of normal tissue receiving near-prescription doses. We hypothesized that deliver ... Full text Link to item Cite

Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: Our 1 year experience

Journal article Journal of Applied Clinical Medical Physics · January 1, 2012 Featured Work American Association of Physicists in Medicine (AAPM) task group (TG) 142 has recently published a report to update recommendations of the AAPM TG 40 report and add new recommendations concerning medical accelerators in the era of image-guided radiation th ... Full text Cite

Impact of volumetric modulated arc therapy technique on treatment with partial breast irradiation.

Journal article Int J Radiat Oncol Biol Phys · September 1, 2010 Featured Work PURPOSE: To investigate the technical feasibility of volumetric modulated arc therapy (V-MAT) in the delivery of partial breast irradiation (PBI). METHODS AND MATERIALS: V-MAT and the standard, three-dimensional conformal radiotherapy (3D-CRT), were compar ... Full text Link to item Cite

Radiotherapy treatment plans with RapidArc for prostate cancer involving seminal vesicles and lymph nodes.

Journal article Int J Radiat Oncol Biol Phys · March 1, 2010 Featured Work PURPOSE: Dosimetric results and treatment delivery efficiency of RapidArc plans to those of conventional intensity-modulated radiotherapy (IMRT) plans were compared using the Eclipse treatment planning system for high-risk prostate cancer. MATERIALS AND ME ... Full text Link to item Cite

Clinical evaluation of positioning verification using digital tomosynthesis and bony anatomy and soft tissues for prostate image-guided radiotherapy.

Journal article Int J Radiat Oncol Biol Phys · January 1, 2009 Featured Work PURPOSE: To evaluate on-board digital tomosynthesis (DTS) for patient positioning vs. two-dimensional (2D) radiography and three-dimensional cone beam (CBCT). METHODS AND MATERIALS: A total of 92 image sessions from 9 prostate cancer patients were analyzed ... Full text Link to item Cite

Assessment of the residual error in soft tissue setup in patients undergoing partial breast irradiation: results of a prospective study using cone-beam computed tomography.

Journal article Int J Radiat Oncol Biol Phys · March 15, 2008 Featured Work PURPOSE: On-board cone-beam computed tomography (CBCT) provides soft tissue information that may improve setup accuracy in patients undergoing accelerated partial breast irradiation (APBI). We used CBCT to assess the residual error in soft tissue after two ... Full text Link to item Cite

Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning.

Journal article Int J Radiat Oncol Biol Phys · December 1, 2006 Featured Work PURPOSE: Cone-beam computed tomography (CBCT) images are currently used for positioning verification. However, it is yet unknown whether CBCT could be used in dose calculation for replanning in adaptive radiation therapy. This study investigates the dosime ... Full text Link to item Cite

A quality assurance program for the on-board imagerĀ®.

Journal article Med Phys · November 2006 Featured Work To develop a quality assurance (QA) program for the On-Board Imager (OBI) system and to summarize the results of these QA tests over extended periods from multiple institutions. Both the radiographic and cone-beam computed tomography (CBCT) mode of operati ... Full text Link to item Cite