Skip to main content

Pulse contour cardiac output analysis in a piglet model of severe hemorrhagic shock.

Journal articles  - Journal Article
Piehl, MD; Manning, JE; McCurdy, SL; Rhue, TS; Kocis, KC; Cairns, CB; Cairns, BA
Published in: Crit Care Med
April 2008

OBJECTIVE: Pulse contour cardiac output (PCCO) analysis is a technique for continuous cardiac output (CO) monitoring through an arterial catheter after calibration by transpulmonary thermodilution (TPTD). Studies in adults show good correlation with pulmonary artery thermodilution (PATD) CO. Data are limited in children and patients with hemodynamic instability. The objective was to determine whether TPTD CO and PCCO analysis correlate with PATD CO in a piglet model of severe hemorrhagic shock. Mixed venous oxygen saturation (SVO2) was also compared with PATD CO. DESIGN: Prospective animal study. SETTING: University animal research laboratory. SUBJECTS: Domesticated piglets, 24-37 kg. INTERVENTIONS: Hemorrhagic shock was created by graded hemorrhage in anesthetized piglets. Hemorrhage was initiated to achieve mean arterial pressure plateaus of 60, 50, 40, 30, and 20 mm Hg. MEASUREMENTS AND MAIN RESULTS: CO was measured by PATD and simultaneously with two femoral artery PCCO catheters. At each mean arterial pressure plateau, one PCCO catheter was recalibrated by TPTD; the other catheter was not recalibrated during hemorrhage. TPTD CO, PCCO measurements from each catheter, and SVO2 were compared with PATD CO at each mean arterial pressure level. TPTD CO and recalibrated PCCO showed excellent correlation (r2 = .96 and .97) and small bias (+0.11 and +0.14 L/min), respectively, compared with PATD. Without recalibration, PCCO measurements were not accurate during rapid hemorrhage (r2 = .22). SVO2 decline did not correlate as well with PATD CO (r2 = .69). CONCLUSIONS: TPTD CO and recalibrated PCCO analysis correlate well with PATD CO in this severe hemorrhagic shock model. The mean difference is small (<0.15 L/min) and is not clinically significant. With rapid changes in blood pressure or intravascular volume, PCCO is not accurate unless recalibrated by TPTD CO. SVO2 did not correlate well with CO in this model.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Crit Care Med

DOI

EISSN

1530-0293

Publication Date

April 2008

Volume

36

Issue

4

Start / End Page

1189 / 1195

Location

United States

Related Subject Headings

  • Thermodilution
  • Swine
  • Shock, Hemorrhagic
  • Pulse
  • Monitoring, Physiologic
  • Linear Models
  • Emergency & Critical Care Medicine
  • Disease Models, Animal
  • Cardiac Output
  • Blood Pressure
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Piehl, M. D., Manning, J. E., McCurdy, S. L., Rhue, T. S., Kocis, K. C., Cairns, C. B., & Cairns, B. A. (2008). Pulse contour cardiac output analysis in a piglet model of severe hemorrhagic shock. Crit Care Med, 36(4), 1189–1195. https://doi.org/10.1097/CCM.0B013E31816592A3
Piehl, Mark D., James E. Manning, Shane L. McCurdy, Tim S. Rhue, Keith C. Kocis, Charles B. Cairns, and Bruce A. Cairns. “Pulse contour cardiac output analysis in a piglet model of severe hemorrhagic shock.Crit Care Med 36, no. 4 (April 2008): 1189–95. https://doi.org/10.1097/CCM.0B013E31816592A3.
Piehl MD, Manning JE, McCurdy SL, Rhue TS, Kocis KC, Cairns CB, et al. Pulse contour cardiac output analysis in a piglet model of severe hemorrhagic shock. Crit Care Med. 2008 Apr;36(4):1189–95.
Piehl, Mark D., et al. “Pulse contour cardiac output analysis in a piglet model of severe hemorrhagic shock.Crit Care Med, vol. 36, no. 4, Apr. 2008, pp. 1189–95. Pubmed, doi:10.1097/CCM.0B013E31816592A3.
Piehl MD, Manning JE, McCurdy SL, Rhue TS, Kocis KC, Cairns CB, Cairns BA. Pulse contour cardiac output analysis in a piglet model of severe hemorrhagic shock. Crit Care Med. 2008 Apr;36(4):1189–1195.

Published In

Crit Care Med

DOI

EISSN

1530-0293

Publication Date

April 2008

Volume

36

Issue

4

Start / End Page

1189 / 1195

Location

United States

Related Subject Headings

  • Thermodilution
  • Swine
  • Shock, Hemorrhagic
  • Pulse
  • Monitoring, Physiologic
  • Linear Models
  • Emergency & Critical Care Medicine
  • Disease Models, Animal
  • Cardiac Output
  • Blood Pressure