Skip to main content
Journal cover image

Sensitive troponin assays in patients with suspected acute coronary syndrome: Results from the multicenter rule out myocardial infarction using computer assisted tomography II trial.

Journal articles  - Journal Article, Multicenter Study
Januzzi, JL; Sharma, U; Zakroysky, P; Truong, QA; Woodard, PK; Pope, JH; Hauser, T; Mayrhofer, T; Nagurney, JT; Schoenfeld, D; Peacock, WF ...
Published in: Am Heart J
April 2015

BACKGROUND: Sensitive troponin (Tn) assays have been developed for the evaluation of patients with suspected acute coronary syndrome (ACS). We sought to compare the performance of a commercially available sensitive Tn I (sTnI) and precommercial highly sTnI (hsTnI) method to conventional Tn (cTn) assays. METHODS: Among patients with acute chest pain but normal cTn in the emergency department of 6 centers, sTnI and hsTnI were measured at baseline, 2 and 4 hours after presentation. Diagnostic accuracy of sTnI and hsTnI relative to cTn for diagnosis during index hospitalization as well as their associations with coronary artery disease in patients randomized to coronary computed tomographic angiography (CTA) was assessed. RESULTS: Overall, 322 patients were enrolled, of whom 161 had a CTA; 28 had ACS (8.7%), including 21 with unstable angina pectoris (UAP). Both sTnI and hsTnI values at baseline and second draw had significantly higher sensitivity for ACS and UAP than cTn and had significantly greater area under the receiver operator characteristic curve than cTn at first and second draws. Compared with cTn, 29% of ACS cases previously categorized as UAP were reclassified to acute myocardial infarction with sTnI or hsTnI. An hsTnI below limit of detection had 100% negative predictive value for ACS or significant coronary artery stenosis in those randomized to CTA. CONCLUSIONS: In patients with acute chest discomfort, use of sTnI and hsTnI methods led to significant improvement in the early diagnostic accuracy for ACS, reclassifying one-third of UAP to myocardial infarction. Very low values for hsTnI excluded underlying coronary artery disease.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Am Heart J

DOI

EISSN

1097-6744

Publication Date

April 2015

Volume

169

Issue

4

Start / End Page

572 / 8.e1

Location

United States

Related Subject Headings

  • Troponin T
  • Tomography, X-Ray Computed
  • Reproducibility of Results
  • ROC Curve
  • Prospective Studies
  • Myocardial Infarction
  • Middle Aged
  • Male
  • Humans
  • Follow-Up Studies
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Januzzi, J. L., Sharma, U., Zakroysky, P., Truong, Q. A., Woodard, P. K., Pope, J. H., … Hoffmann, U. (2015). Sensitive troponin assays in patients with suspected acute coronary syndrome: Results from the multicenter rule out myocardial infarction using computer assisted tomography II trial. Am Heart J, 169(4), 572-8.e1. https://doi.org/10.1016/j.ahj.2014.12.023
Januzzi, James L., Umesh Sharma, Pearl Zakroysky, Quynh A. Truong, Pamela K. Woodard, J Hector Pope, Thomas Hauser, et al. “Sensitive troponin assays in patients with suspected acute coronary syndrome: Results from the multicenter rule out myocardial infarction using computer assisted tomography II trial.Am Heart J 169, no. 4 (April 2015): 572-8.e1. https://doi.org/10.1016/j.ahj.2014.12.023.
Januzzi, James L., et al. “Sensitive troponin assays in patients with suspected acute coronary syndrome: Results from the multicenter rule out myocardial infarction using computer assisted tomography II trial.Am Heart J, vol. 169, no. 4, Apr. 2015, pp. 572-8.e1. Pubmed, doi:10.1016/j.ahj.2014.12.023.
Januzzi JL, Sharma U, Zakroysky P, Truong QA, Woodard PK, Pope JH, Hauser T, Mayrhofer T, Nagurney JT, Schoenfeld D, Peacock WF, Fleg JL, Wiviott S, Pang PS, Udelson J, Hoffmann U. Sensitive troponin assays in patients with suspected acute coronary syndrome: Results from the multicenter rule out myocardial infarction using computer assisted tomography II trial. Am Heart J. 2015 Apr;169(4):572–8.e1.
Journal cover image

Published In

Am Heart J

DOI

EISSN

1097-6744

Publication Date

April 2015

Volume

169

Issue

4

Start / End Page

572 / 8.e1

Location

United States

Related Subject Headings

  • Troponin T
  • Tomography, X-Ray Computed
  • Reproducibility of Results
  • ROC Curve
  • Prospective Studies
  • Myocardial Infarction
  • Middle Aged
  • Male
  • Humans
  • Follow-Up Studies