Four-parameter paired response curve for serial dilution assays.
Publication
, Journal Article
Fong, Y; Permar, SR; Tomaras, GD
Published in: J Biopharm Stat
September 3, 2021
Newer immunoassay platforms offer improved signal-to-noise ratio but are more expensive. Thus, it is more cost efficient to perform these assays at a few selected, rather than a full series of, sample dilutions. We propose a new four-parameter paired response curve to model the relationship between assay outcomes from two sample dilutions and study likelihood-based inference. Given a fitted paired response curve, we can predict assay outcomes for de novo dilutions of samples, which enables cross-protocol comparison of immune response biomarkers even when different protocols use different sample dilutions. Numerical studies on both simulated and real data are presented.
Duke Scholars
Published In
J Biopharm Stat
DOI
EISSN
1520-5711
Publication Date
September 3, 2021
Volume
31
Issue
5
Start / End Page
634 / 649
Location
England
Related Subject Headings
- Statistics & Probability
- Likelihood Functions
- Immunoassay
- Humans
- Biological Assay
- 4905 Statistics
- 3214 Pharmacology and pharmaceutical sciences
- 1115 Pharmacology and Pharmaceutical Sciences
Citation
APA
Chicago
ICMJE
MLA
NLM
Fong, Y., Permar, S. R., & Tomaras, G. D. (2021). Four-parameter paired response curve for serial dilution assays. J Biopharm Stat, 31(5), 634–649. https://doi.org/10.1080/10543406.2021.1931271
Fong, Youyi, Sallie R. Permar, and Georgia D. Tomaras. “Four-parameter paired response curve for serial dilution assays.” J Biopharm Stat 31, no. 5 (September 3, 2021): 634–49. https://doi.org/10.1080/10543406.2021.1931271.
Fong Y, Permar SR, Tomaras GD. Four-parameter paired response curve for serial dilution assays. J Biopharm Stat. 2021 Sep 3;31(5):634–49.
Fong, Youyi, et al. “Four-parameter paired response curve for serial dilution assays.” J Biopharm Stat, vol. 31, no. 5, Sept. 2021, pp. 634–49. Pubmed, doi:10.1080/10543406.2021.1931271.
Fong Y, Permar SR, Tomaras GD. Four-parameter paired response curve for serial dilution assays. J Biopharm Stat. 2021 Sep 3;31(5):634–649.
Published In
J Biopharm Stat
DOI
EISSN
1520-5711
Publication Date
September 3, 2021
Volume
31
Issue
5
Start / End Page
634 / 649
Location
England
Related Subject Headings
- Statistics & Probability
- Likelihood Functions
- Immunoassay
- Humans
- Biological Assay
- 4905 Statistics
- 3214 Pharmacology and pharmaceutical sciences
- 1115 Pharmacology and Pharmaceutical Sciences