Correction of Patient-Ventilator Discordance.

Journal articles  - Journal Article, Review
Davies, J; Pratt, E; Rackley, CR
Published in: Respir Care
June 2026

Optimizing the interaction between the patient and the ventilator should be a cornerstone for clinicians to pursue. Disruptions in these interactions can lead to what is called patient-ventilator discordance. Patient-ventilator discordance is a mismatch between what the patient desires in a breath and what the ventilator provides. Asynchrony is also a common term used to describe these unhealthy interactions. Different types of asynchronies make up the more global term of patient-ventilator discordance. Asynchronies can occur at the onset of a breath (trigger asynchrony), during breath delivery (flow asynchrony), or at the end of a breath (cycle asynchrony). Prompt identification and correction of these asynchronies is pivotal to prevent overuse of sedation, extended duration of mechanical ventilation, and perhaps an increased mortality risk. Clinicians must also take into consideration the phenomenon of ventilator-related dyspnea. Dyspnea is defined as a subjective feeling of breathing discomfort. In a ventilated patient dyspnea often goes unrecognized, as there is a communication barrier. Similar to the sensation of pain, recognizing and managing dyspnea is vital in mechanically ventilated patients.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Respir Care

DOI

EISSN

1943-3654

Publication Date

June 2026

Volume

71

Issue

6

Start / End Page

670 / 686

Location

United States

Related Subject Headings

  • Respiratory System
  • Respiration, Artificial
  • Patient-Ventilator Asynchrony
  • Humans
  • Dyspnea
  • 3202 Clinical sciences
  • 3201 Cardiovascular medicine and haematology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Davies, J., Pratt, E., & Rackley, C. R. (2026). Correction of Patient-Ventilator Discordance. Respir Care, 71(6), 670–686. https://doi.org/10.1177/19433654261425215
Davies, John, Elias Pratt, and Craig R. Rackley. “Correction of Patient-Ventilator Discordance.Respir Care 71, no. 6 (June 2026): 670–86. https://doi.org/10.1177/19433654261425215.
Davies J, Pratt E, Rackley CR. Correction of Patient-Ventilator Discordance. Respir Care. 2026 Jun;71(6):670–86.
Davies, John, et al. “Correction of Patient-Ventilator Discordance.Respir Care, vol. 71, no. 6, June 2026, pp. 670–86. Pubmed, doi:10.1177/19433654261425215.
Davies J, Pratt E, Rackley CR. Correction of Patient-Ventilator Discordance. Respir Care. 2026 Jun;71(6):670–686.

Published In

Respir Care

DOI

EISSN

1943-3654

Publication Date

June 2026

Volume

71

Issue

6

Start / End Page

670 / 686

Location

United States

Related Subject Headings

  • Respiratory System
  • Respiration, Artificial
  • Patient-Ventilator Asynchrony
  • Humans
  • Dyspnea
  • 3202 Clinical sciences
  • 3201 Cardiovascular medicine and haematology