Skip to main content
construction release_alert
Profile editing will be unavailable for Scholars@Duke profiles from June 11-24, 2026 as manual profile data entry transitions to Elements. More information about the transition.
cancel
Journal cover image

Simultaneous acquisition of cerebral blood volume-, blood flow-, and blood oxygenation-weighted MRI signals at ultra-high magnetic field.

Publication ,  Journal Article
Krieger, SN; Huber, L; Poser, BA; Turner, R; Egan, GF
Published in: Magn Reson Med
August 2015

PURPOSE: Yang et al. proposed an MRI technique for the simultaneous acquisition of cerebral blood volume (CBV), cerebral blood flow (CBF), and blood oxygenation level-dependent (BOLD)-weighted MRI signals (9). The purpose of this study was to develop modified version of the Yang sequence, which utilizes the advantages of 7 Tesla, leading to a robust and reliable MRI sequence. METHODS: The inversion recovery-based MR pulse sequence introduced here involves slice-saturation slab-inversion vascular space occupancy (SI-SS-VASO) MRI, double echo planar imaging readouts for arterial spin labeling, and VASO in order to correct for BOLD contamination, and a separate BOLD acquisition to minimize inversion effects on the BOLD signal. A standard visual stimulus block design was used to evaluate the spatial and temporal characteristics of CBV-, CBF-, and BOLD-weighted images. RESULTS: The high signal-to-noise ratio and spatial resolution of this method leads to robust activation maps. This technique enables the investigation of the differential spatial specificity and temporal characteristics of the different modalities. CONCLUSION: The pulse sequence could be a powerful tool for studies of neurovascular coupling, hemodynamic response, or calibrated BOLD.

Duke Scholars

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

August 2015

Volume

74

Issue

2

Start / End Page

513 / 517

Location

United States

Related Subject Headings

  • Signal-To-Noise Ratio
  • Signal Processing, Computer-Assisted
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiation Dosage
  • Oxygen
  • Oximetry
  • Nuclear Medicine & Medical Imaging
  • Male
  • Magnetic Resonance Angiography
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Krieger, S. N., Huber, L., Poser, B. A., Turner, R., & Egan, G. F. (2015). Simultaneous acquisition of cerebral blood volume-, blood flow-, and blood oxygenation-weighted MRI signals at ultra-high magnetic field. Magn Reson Med, 74(2), 513–517. https://doi.org/10.1002/mrm.25431
Krieger, Steffen N., Laurentius Huber, Benedikt A. Poser, Robert Turner, and Gary F. Egan. “Simultaneous acquisition of cerebral blood volume-, blood flow-, and blood oxygenation-weighted MRI signals at ultra-high magnetic field.Magn Reson Med 74, no. 2 (August 2015): 513–17. https://doi.org/10.1002/mrm.25431.
Krieger, Steffen N., et al. “Simultaneous acquisition of cerebral blood volume-, blood flow-, and blood oxygenation-weighted MRI signals at ultra-high magnetic field.Magn Reson Med, vol. 74, no. 2, Aug. 2015, pp. 513–17. Pubmed, doi:10.1002/mrm.25431.
Krieger SN, Huber L, Poser BA, Turner R, Egan GF. Simultaneous acquisition of cerebral blood volume-, blood flow-, and blood oxygenation-weighted MRI signals at ultra-high magnetic field. Magn Reson Med. 2015 Aug;74(2):513–517.
Journal cover image

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

August 2015

Volume

74

Issue

2

Start / End Page

513 / 517

Location

United States

Related Subject Headings

  • Signal-To-Noise Ratio
  • Signal Processing, Computer-Assisted
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radiation Dosage
  • Oxygen
  • Oximetry
  • Nuclear Medicine & Medical Imaging
  • Male
  • Magnetic Resonance Angiography