Use of a microvascular clip for iris fixation of an intraocular lens: a laboratory model.
Journal articles
- Journal Article
Tzu, JH; Desai, NR; Akpek, EK
Published in: Arch Ophthalmol
January 2010
Here we present a potential novel surgical technique consisting of fixation of a posterior-chamber intraocular lens to the iris that may be used in the treatment of aphakia or the management of intraocular lens complications when capsular support has been compromised. The technique was performed in a laboratory model using cadaveric human eyes. A commercially available neurovascular clip was used to securely fasten the intraocular lens to the iris with minimal trauma. The use of a metal clip has the advantage of avoiding potential risks of suture fixation such as suture breakage. Also, this technique is easier than suturing and may potentially serve as another tool in a cornea surgeon's armamentarium.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
Arch Ophthalmol
DOI
EISSN
1538-3601
Publication Date
January 2010
Volume
128
Issue
1
Start / End Page
114 / 116
Location
United States
Related Subject Headings
- Surgical Instruments
- Ophthalmology & Optometry
- Models, Biological
- Lenses, Intraocular
- Lens Implantation, Intraocular
- Iris
- Humans
Citation
APA
Chicago
ICMJE
MLA
NLM
Tzu, J. H., Desai, N. R., & Akpek, E. K. (2010). Use of a microvascular clip for iris fixation of an intraocular lens: a laboratory model. Arch Ophthalmol, 128(1), 114–116. https://doi.org/10.1001/archophthalmol.2009.351
Tzu, Jonathan H., Neel R. Desai, and Esen K. Akpek. “Use of a microvascular clip for iris fixation of an intraocular lens: a laboratory model.” Arch Ophthalmol 128, no. 1 (January 2010): 114–16. https://doi.org/10.1001/archophthalmol.2009.351.
Tzu JH, Desai NR, Akpek EK. Use of a microvascular clip for iris fixation of an intraocular lens: a laboratory model. Arch Ophthalmol. 2010 Jan;128(1):114–6.
Tzu, Jonathan H., et al. “Use of a microvascular clip for iris fixation of an intraocular lens: a laboratory model.” Arch Ophthalmol, vol. 128, no. 1, Jan. 2010, pp. 114–16. Pubmed, doi:10.1001/archophthalmol.2009.351.
Tzu JH, Desai NR, Akpek EK. Use of a microvascular clip for iris fixation of an intraocular lens: a laboratory model. Arch Ophthalmol. 2010 Jan;128(1):114–116.
Published In
Arch Ophthalmol
DOI
EISSN
1538-3601
Publication Date
January 2010
Volume
128
Issue
1
Start / End Page
114 / 116
Location
United States
Related Subject Headings
- Surgical Instruments
- Ophthalmology & Optometry
- Models, Biological
- Lenses, Intraocular
- Lens Implantation, Intraocular
- Iris
- Humans