Skip to main content
Journal cover image

Pediatric keratoprosthesis.

Journal articles  - Journal Article
Aquavella, JV; Gearinger, MD; Akpek, EK; McCormick, GJ
Published in: Ophthalmology
May 2007

OBJECTIVE: To describe the authors' experience using keratoprosthesis to treat pediatric corneal opacity. DESIGN: Nonrandomized, consecutive, retrospective interventional series. PARTICIPANTS: Twenty-two eyes of 17 children with opaque corneas as a result of primary congenital disease and or previous failed keratoplasty. METHODS: A retrospective review of pediatric patients with a history of corneal opacification treated with keratoprosthesis surgery. MAIN OUTCOME MEASURES: Intraocular pressure, inflammation, clarity of the visual axis, visual acuity, refraction, complications, and retention of the prosthesis. RESULTS: Twenty-two eyes of 17 patients 1.5 to 136 months of age underwent 23 keratoprosthesis procedures. The follow-up period was 220 patient months (range, 1-37 months; mean, 9.7 months). In both cases implanted with the AlphaCor (Argus Biomedical Pty. Ltd., Perth, Australia), the keratoprosthesis was not retained. In one instance, the prosthesis sustained traumatic dislocation and was replaced with a cadaver cornea. In the second instance, the intralamellar implant began to extrude and was replaced with a Boston keratoprosthesis. In all 21 Boston cases, the prosthesis was retained without dislocation or extrusion. The visual axis remained clear in 100% of cases, although retroprosthetic membranes were removed in 5 eyes. Reoperation was necessitated for management of concurrent glaucoma (n = 3) or retinopathy (n = 2). There were no instances of surface infection or endophthalmitis. In 7 instances where patient age was 4 years or more, visual acuity ranged from counting fingers to 20/30. In the remaining cases, all infants were able to follow light, fingers, and objects. Intraocular pressure was controlled in all cases. CONCLUSIONS: Implantation of the Boston keratoprosthesis rapidly establishes and maintains a clear optical pathway and does not prejudice management of concurrent glaucoma or retinopathy. The device is retained without extrusion or rejection and is appropriate for the management of pediatric corneal opacity.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Ophthalmology

DOI

EISSN

1549-4713

Publication Date

May 2007

Volume

114

Issue

5

Start / End Page

989 / 994

Location

United States

Related Subject Headings

  • Visual Acuity
  • Retrospective Studies
  • Refraction, Ocular
  • Prosthesis Implantation
  • Prostheses and Implants
  • Postoperative Complications
  • Ophthalmology & Optometry
  • Male
  • Intraoperative Complications
  • Intraocular Pressure
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Aquavella, J. V., Gearinger, M. D., Akpek, E. K., & McCormick, G. J. (2007). Pediatric keratoprosthesis. Ophthalmology, 114(5), 989–994. https://doi.org/10.1016/j.ophtha.2007.01.027
Aquavella, James V., Matthew D. Gearinger, Esen K. Akpek, and Gregory J. McCormick. “Pediatric keratoprosthesis.Ophthalmology 114, no. 5 (May 2007): 989–94. https://doi.org/10.1016/j.ophtha.2007.01.027.
Aquavella JV, Gearinger MD, Akpek EK, McCormick GJ. Pediatric keratoprosthesis. Ophthalmology. 2007 May;114(5):989–94.
Aquavella, James V., et al. “Pediatric keratoprosthesis.Ophthalmology, vol. 114, no. 5, May 2007, pp. 989–94. Pubmed, doi:10.1016/j.ophtha.2007.01.027.
Aquavella JV, Gearinger MD, Akpek EK, McCormick GJ. Pediatric keratoprosthesis. Ophthalmology. 2007 May;114(5):989–994.
Journal cover image

Published In

Ophthalmology

DOI

EISSN

1549-4713

Publication Date

May 2007

Volume

114

Issue

5

Start / End Page

989 / 994

Location

United States

Related Subject Headings

  • Visual Acuity
  • Retrospective Studies
  • Refraction, Ocular
  • Prosthesis Implantation
  • Prostheses and Implants
  • Postoperative Complications
  • Ophthalmology & Optometry
  • Male
  • Intraoperative Complications
  • Intraocular Pressure