Skip to main content
Journal cover image

Subluxation of suture-fixated posterior chamber intraocular lenses a clinicopathologic study.

Journal articles  - Journal Article
Parekh, P; Green, WR; Stark, WJ; Akpek, EK
Published in: Ophthalmology
February 2007

PURPOSE: To report the occurrence of subluxation of suture-fixated posterior chamber (PC) intraocular lenses (IOL) and elucidate the mechanisms involved. DESIGN: Prospective clinicopathologic study. PARTICIPANTS: A single 10-0 Prolene suture explanted from a patient who experienced subluxation of his PC-IOL, 11.5 years after placement. Furthermore, multiple 10-0 Prolene sutures and PC-IOLs used for iris fixation were studied as controls. METHODS: Scanning electron microscopy (SEM) was used to analyze the surface of the explanted suture. In addition, randomly selected 10-0 Prolene sutures cut with Vannas scissors and cut with the positioning holes of a randomly selected PC-IOL identical to that implanted in the patient's eye were examined as controls. Finally, the positioning holes of several randomly selected, iris-fixated PC-IOLs were studied using SEM with particular attention to surface quality and edge finish. MAIN OUTCOME MEASURES: Presence of any signs of suture degradation, the character of the cut edge of the suture, as well as the characteristics of the positioning holes of the PC-IOLs. RESULTS: Scanning electron microscopy of the explanted suture revealed sharply cut edges, without significant degradation of the suture, and no intact loop. Scanning electron microscopy of the control suture cut with a PC-IOL demonstrated a similarly cut edge. The positioning holes of the examined PC-IOLs had a sharp edge, and some also had an imperfect finish. CONCLUSION: We conclude that the surface properties of the positioning holes lead to cutting of the suture, and subsequent subluxation of the PC-IOL.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Ophthalmology

DOI

EISSN

1549-4713

Publication Date

February 2007

Volume

114

Issue

2

Start / End Page

232 / 237

Location

United States

Related Subject Headings

  • Sutures
  • Suture Techniques
  • Prosthesis Failure
  • Prospective Studies
  • Polypropylenes
  • Ophthalmology & Optometry
  • Middle Aged
  • Microscopy, Electron, Scanning
  • Male
  • Lenses, Intraocular
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Parekh, P., Green, W. R., Stark, W. J., & Akpek, E. K. (2007). Subluxation of suture-fixated posterior chamber intraocular lenses a clinicopathologic study. Ophthalmology, 114(2), 232–237. https://doi.org/10.1016/j.ophtha.2006.10.037
Parekh, Parag, W Richard Green, Walter J. Stark, and Esen Karamursel Akpek. “Subluxation of suture-fixated posterior chamber intraocular lenses a clinicopathologic study.Ophthalmology 114, no. 2 (February 2007): 232–37. https://doi.org/10.1016/j.ophtha.2006.10.037.
Parekh P, Green WR, Stark WJ, Akpek EK. Subluxation of suture-fixated posterior chamber intraocular lenses a clinicopathologic study. Ophthalmology. 2007 Feb;114(2):232–7.
Parekh, Parag, et al. “Subluxation of suture-fixated posterior chamber intraocular lenses a clinicopathologic study.Ophthalmology, vol. 114, no. 2, Feb. 2007, pp. 232–37. Pubmed, doi:10.1016/j.ophtha.2006.10.037.
Parekh P, Green WR, Stark WJ, Akpek EK. Subluxation of suture-fixated posterior chamber intraocular lenses a clinicopathologic study. Ophthalmology. 2007 Feb;114(2):232–237.
Journal cover image

Published In

Ophthalmology

DOI

EISSN

1549-4713

Publication Date

February 2007

Volume

114

Issue

2

Start / End Page

232 / 237

Location

United States

Related Subject Headings

  • Sutures
  • Suture Techniques
  • Prosthesis Failure
  • Prospective Studies
  • Polypropylenes
  • Ophthalmology & Optometry
  • Middle Aged
  • Microscopy, Electron, Scanning
  • Male
  • Lenses, Intraocular