Noninvasive volumetric quality evaluation of post-surgical clear corneal incision via high-resolution Fourier-domain optical coherence tomography
Journal articles
- Journal Article
Zhang, K; Akpek, EK; Weiblinger, RP; Kim, DH; Kang, JU; Ilev, IK
Published in: Electronics Letters
October 28, 2010
A novel approach for post-surgical evaluation of clear corneal incision quality is presented. The complete volumetric information of an ex-vivo bovine cornea with incision and suture is obtained by high-resolution Fourier-domain optical coherence tomography and illustrated by various computer graphics technologies. This method provides more comprehensive information to evaluate surgery quality and monitor the healing process. © 2010 The Institution of Engineering and Technology.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
Electronics Letters
DOI
ISSN
0013-5194
Publication Date
October 28, 2010
Volume
46
Issue
22
Start / End Page
1482 / 1483
Related Subject Headings
- Electrical & Electronic Engineering
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering
Citation
APA
Chicago
ICMJE
MLA
NLM
Zhang, K., Akpek, E. K., Weiblinger, R. P., Kim, D. H., Kang, J. U., & Ilev, I. K. (2010). Noninvasive volumetric quality evaluation of post-surgical clear corneal incision via high-resolution Fourier-domain optical coherence tomography. Electronics Letters, 46(22), 1482–1483. https://doi.org/10.1049/el.2010.8667
Zhang, K., E. K. Akpek, R. P. Weiblinger, D. H. Kim, J. U. Kang, and I. K. Ilev. “Noninvasive volumetric quality evaluation of post-surgical clear corneal incision via high-resolution Fourier-domain optical coherence tomography.” Electronics Letters 46, no. 22 (October 28, 2010): 1482–83. https://doi.org/10.1049/el.2010.8667.
Zhang K, Akpek EK, Weiblinger RP, Kim DH, Kang JU, Ilev IK. Noninvasive volumetric quality evaluation of post-surgical clear corneal incision via high-resolution Fourier-domain optical coherence tomography. Electronics Letters. 2010 Oct 28;46(22):1482–3.
Zhang, K., et al. “Noninvasive volumetric quality evaluation of post-surgical clear corneal incision via high-resolution Fourier-domain optical coherence tomography.” Electronics Letters, vol. 46, no. 22, Oct. 2010, pp. 1482–83. Scopus, doi:10.1049/el.2010.8667.
Zhang K, Akpek EK, Weiblinger RP, Kim DH, Kang JU, Ilev IK. Noninvasive volumetric quality evaluation of post-surgical clear corneal incision via high-resolution Fourier-domain optical coherence tomography. Electronics Letters. 2010 Oct 28;46(22):1482–1483.
Published In
Electronics Letters
DOI
ISSN
0013-5194
Publication Date
October 28, 2010
Volume
46
Issue
22
Start / End Page
1482 / 1483
Related Subject Headings
- Electrical & Electronic Engineering
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering