Skip to main content
Journal cover image

Boston Type 1 Keratoprosthesis versus Repeat Donor Keratoplasty for Corneal Graft Failure: A Systematic Review and Meta-analysis.

Journal articles  - Journal Article, Systematic Review
Ahmad, S; Mathews, PM; Lindsley, K; Alkharashi, M; Hwang, FS; Ng, SM; Aldave, AJ; Akpek, EK
Published in: Ophthalmology
January 2016

PURPOSE: To compare repeat penetrating keratoplasty (PK) with Boston type I keratoprosthesis (KPro) implantation for full-thickness donor corneal graft failure. DESIGN: Previous donor graft failure is a common indication for both PK and KPro implantation. Selection of the surgical procedure is entirely dependent on the surgeon because there are no studies available for guidance. Therefore, a systematic review was undertaken to examine vision, device retention, graft clarity, and postoperative glaucoma and infection outcomes after repeat PK versus KPro implantation. METHODS: Articles with data regarding repeat PK published between 1990 and 2014 were identified in PubMed, EMBASE, the Latin American and Caribbean Health Sciences Literature Database, and the Cochrane Central Register of Controlled Trials and were reviewed. Results were compared with a retrospective review of consecutive, nonrandomized, longitudinal case series of KPro implantations performed at 5 tertiary care centers in the United States. Visual acuity at 2 years was the primary outcome measure. The proportion of clear grafts in the repeat PK group, device retention in the KPro group, and the development of postoperative glaucoma and infection were secondary outcome measures. RESULTS: The search strategy identified 17 128 articles in the PK analysis. After screening, 26 studies (21 case series and 5 cohort studies) were included in the review. Pooled analysis of the 26 unique studies demonstrated a 42% (95% confidence interval [CI], 30%-56%) likelihood of maintaining 20/200 or better at 2 years after repeat PK, compared with an 80% (95% CI, 68%-88%) probability with KPro implantation. The probability of maintaining a clear graft at 5 years was 47% (95% CI, 40%-54%) after repeat PK, whereas the probability of retention of the KPro at 5 years was 75% (95% CI, 64%-84%). The rate of progression of glaucoma at 3 years was 25% (95% CI, 10%-44%) after repeat PK and 30% in the KPro cohort. CONCLUSIONS: These results demonstrate favorable outcomes of KPro surgery for donor corneal graft failure with a greater likelihood of maintaining visual improvement without higher risk of postoperative glaucoma compared with repeat donor PK.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Ophthalmology

DOI

EISSN

1549-4713

Publication Date

January 2016

Volume

123

Issue

1

Start / End Page

165 / 177

Location

United States

Related Subject Headings

  • Visual Acuity
  • Reoperation
  • Prostheses and Implants
  • Ophthalmology & Optometry
  • Keratoplasty, Penetrating
  • Humans
  • Graft Survival
  • Graft Rejection
  • Corneal Diseases
  • Artificial Organs
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ahmad, S., Mathews, P. M., Lindsley, K., Alkharashi, M., Hwang, F. S., Ng, S. M., … Akpek, E. K. (2016). Boston Type 1 Keratoprosthesis versus Repeat Donor Keratoplasty for Corneal Graft Failure: A Systematic Review and Meta-analysis. Ophthalmology, 123(1), 165–177. https://doi.org/10.1016/j.ophtha.2015.09.028
Ahmad, Sumayya, Priya M. Mathews, Kristina Lindsley, Majed Alkharashi, Frank S. Hwang, Sueko M. Ng, Anthony J. Aldave, and Esen Karamursel Akpek. “Boston Type 1 Keratoprosthesis versus Repeat Donor Keratoplasty for Corneal Graft Failure: A Systematic Review and Meta-analysis.Ophthalmology 123, no. 1 (January 2016): 165–77. https://doi.org/10.1016/j.ophtha.2015.09.028.
Ahmad S, Mathews PM, Lindsley K, Alkharashi M, Hwang FS, Ng SM, et al. Boston Type 1 Keratoprosthesis versus Repeat Donor Keratoplasty for Corneal Graft Failure: A Systematic Review and Meta-analysis. Ophthalmology. 2016 Jan;123(1):165–77.
Ahmad, Sumayya, et al. “Boston Type 1 Keratoprosthesis versus Repeat Donor Keratoplasty for Corneal Graft Failure: A Systematic Review and Meta-analysis.Ophthalmology, vol. 123, no. 1, Jan. 2016, pp. 165–77. Pubmed, doi:10.1016/j.ophtha.2015.09.028.
Ahmad S, Mathews PM, Lindsley K, Alkharashi M, Hwang FS, Ng SM, Aldave AJ, Akpek EK. Boston Type 1 Keratoprosthesis versus Repeat Donor Keratoplasty for Corneal Graft Failure: A Systematic Review and Meta-analysis. Ophthalmology. 2016 Jan;123(1):165–177.
Journal cover image

Published In

Ophthalmology

DOI

EISSN

1549-4713

Publication Date

January 2016

Volume

123

Issue

1

Start / End Page

165 / 177

Location

United States

Related Subject Headings

  • Visual Acuity
  • Reoperation
  • Prostheses and Implants
  • Ophthalmology & Optometry
  • Keratoplasty, Penetrating
  • Humans
  • Graft Survival
  • Graft Rejection
  • Corneal Diseases
  • Artificial Organs