Comparison of Retrospective Motion Compensation Techniques for Pulmonary Dynamic Ultrashort Time to Echo MRI in Suspected Idiopathic Pulmonary Fibrosis.

Journal articles  - Journal Article
Kizhakke Puliyakote, AS; Torres, LA; AlAtoum, A; AlArab, N; Johnson, KM; Bello, RM; O'Sullivan-Murphy, B; Mammarappallil, JG; Hahn, AD; Fain, SB
Published in: J Magn Reson Imaging
September 2026

BACKGROUND: Motion can degrade image quality during Ultrashort Time-to-Echo (UTE) pulmonary MRI and is particularly prevalent in patients with lung disease. Comprehensive assessment of the impact of motion compensation techniques on image quality and clinical interpretation is needed. PURPOSE/HYPOTHESIS: To compare the impact of retrospective motion compensation schemes on image quality and clinical interpretation of pulmonary UTE MRI in idiopathic pulmonary fibrosis (IPF). STUDY TYPE: Prospective. POPULATION: 21 (male = 18; mean age, 69.9 ± 8.1 years) participants with suspected IPF. FIELD STRENGTH/SEQUENCE: 1.5 T/3 T, 3D center-out radial (gradient-echo) UTE sequence with 2× radial oversampling, while free-breathing. ASSESSMENT: Images were reconstructed to 1.25 mm isotropic resolution using five retrospective schemes: no gating, hard-gating, soft-gating, motion-resolved (XD-GRASP), and an iterative approach (iMoCo). Signal-to-noise ratios (SNR) were estimated within the lung parenchyma, airways, aorta, muscles, and liver. Contrast-to-noise ratios (CNR) were estimated using the mean airway signal as reference. Image sharpness was estimated using the maximum derivative of a line profile across the diaphragm and a wavelet-based autofocus measure. Three radiologists evaluated image quality, motion artifacts on a 5-point Likert scale, and diagnostic classification of usual interstitial pneumonia (UIP). STATISTICAL TESTS: The Kruskal-Wallis non-parametric test was used for qualitative reader scores and one-way ANOVA for the quantitative metrics, with p < 0.05 as the threshold for significance. RESULTS: CNR was highest using the iMoCo reconstructions (lung parenchyma: 1.64 ± 1.41 vs. 0.88 ± 0.81 via XD-GRASP). Image sharpness was significantly improved using compressed sensing (CS)-based techniques (XD-GRASP and iMoCo), compared to the other methods, using both diaphragm profile (CS: 6.28 ± 3.70 vs. non-CS: 3.73 ± 2.06) and wavelet metrics (CS: 2.33 ± 0.42 vs. non-CS: 2.05 ± 0.35). CS methods also demonstrated greatest image quality based on reader scores. CONCLUSION: Motion compensation using compressed sensing methods can improve image quality and clinical utility of UTE-MRI in the identification and diagnostic classification of typical parenchymal fibrotic patterns. EVIDENCE LEVEL: Level 2-Prospective study, with a reference standard determined during the course of the study (CT imaging). TECHNICAL EFFICACY: Stage 1.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Magn Reson Imaging

DOI

EISSN

1522-2586

Publication Date

September 2026

Volume

64

Issue

3

Start / End Page

644 / 654

Location

United States

Related Subject Headings

  • Signal-To-Noise Ratio
  • Retrospective Studies
  • Respiration
  • Reproducibility of Results
  • Prospective Studies
  • Nuclear Medicine & Medical Imaging
  • Motion
  • Middle Aged
  • Male
  • Magnetic Resonance Imaging
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kizhakke Puliyakote, A. S., Torres, L. A., AlAtoum, A., AlArab, N., Johnson, K. M., Bello, R. M., … Fain, S. B. (2026). Comparison of Retrospective Motion Compensation Techniques for Pulmonary Dynamic Ultrashort Time to Echo MRI in Suspected Idiopathic Pulmonary Fibrosis. J Magn Reson Imaging, 64(3), 644–654. https://doi.org/10.1002/jmri.70350
Kizhakke Puliyakote, Abhilash S., Luis A. Torres, Aiah AlAtoum, Natally AlArab, Kevin M. Johnson, Rodrigo M. Bello, Bryan O’Sullivan-Murphy, Joseph G. Mammarappallil, Andrew D. Hahn, and Sean B. Fain. “Comparison of Retrospective Motion Compensation Techniques for Pulmonary Dynamic Ultrashort Time to Echo MRI in Suspected Idiopathic Pulmonary Fibrosis.” J Magn Reson Imaging 64, no. 3 (September 2026): 644–54. https://doi.org/10.1002/jmri.70350.
Kizhakke Puliyakote AS, Torres LA, AlAtoum A, AlArab N, Johnson KM, Bello RM, et al. Comparison of Retrospective Motion Compensation Techniques for Pulmonary Dynamic Ultrashort Time to Echo MRI in Suspected Idiopathic Pulmonary Fibrosis. J Magn Reson Imaging. 2026 Sep;64(3):644–54.
Kizhakke Puliyakote, Abhilash S., et al. “Comparison of Retrospective Motion Compensation Techniques for Pulmonary Dynamic Ultrashort Time to Echo MRI in Suspected Idiopathic Pulmonary Fibrosis.” J Magn Reson Imaging, vol. 64, no. 3, Sept. 2026, pp. 644–54. Pubmed, doi:10.1002/jmri.70350.
Kizhakke Puliyakote AS, Torres LA, AlAtoum A, AlArab N, Johnson KM, Bello RM, O’Sullivan-Murphy B, Mammarappallil JG, Hahn AD, Fain SB. Comparison of Retrospective Motion Compensation Techniques for Pulmonary Dynamic Ultrashort Time to Echo MRI in Suspected Idiopathic Pulmonary Fibrosis. J Magn Reson Imaging. 2026 Sep;64(3):644–654.
Journal cover image

Published In

J Magn Reson Imaging

DOI

EISSN

1522-2586

Publication Date

September 2026

Volume

64

Issue

3

Start / End Page

644 / 654

Location

United States

Related Subject Headings

  • Signal-To-Noise Ratio
  • Retrospective Studies
  • Respiration
  • Reproducibility of Results
  • Prospective Studies
  • Nuclear Medicine & Medical Imaging
  • Motion
  • Middle Aged
  • Male
  • Magnetic Resonance Imaging