Skip to main content
Journal cover image

Endoscopic Proximal Hamstring Repairs Remain Safe and Beneficial With High Patient Satisfaction at a Minimum of 6-Year Follow-Up.

Journal articles  - Journal Article
Greenwood, SN; Adebayo, T; Reinke, EK; Fletcher, AN; Lewis, BD; Scott, EJ; Mather, RC
Published in: Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
September 2026

To evaluate midterm outcomes of endoscopic proximal hamstring repair in a previously established cohort.A retrospective study design was used for a midterm (minimum 6 years) follow-up time. Patients completed the questionnaires over the phone or electronically on REDCap after consent. The questionnaires included the modified Harris Hip Score, the Hip Outcome (HOS), the Sports Subscale (HOS-SSS), the Single Assessment Numeric Evaluation, the International Hip Outcome Tool-12, VAS pain scale, and queried on satisfaction with the surgery. Descriptive statistics including mean and variance were used to analyze the results and compare values preoperatively and at the midterm time point.Twenty two of 29 individuals participated (75.8%). Minimum follow-up time was 6.2 years with a maximum follow-up time of 10.6 years (mean 7.6, SD 1.08). Subjects reported a mean modified Harris Hip Score of 82.6 (SD 17.1, range 46.2-100.1), mean HOS of 83.2 (SD 19.9, range 33.8-100), mean HOS-SSS of 89.2 (SD 15, range 50-100, n = 12), mean Single Assessment Numeric Evaluation of 80.2% (SD 20.6, range 30-100%), mean the International Hip Outcome Tool-12 of 79.5 (SD 22.7, range 32.5-100), mean pain score of 1.7 (SD 2.4, range 0-7), and 86.4% satisfaction with the surgery.Endoscopic hamstring repair remains beneficial with high patient satisfaction (86.4%, n = 22) and patient-reported outcome scores (85.7% reaching acceptable symptom state, n = 21) at midterm follow-up.Level IV, retrospective case series.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

DOI

EISSN

1526-3231

ISSN

0749-8063

Publication Date

September 2026

Volume

42

Issue

9

Start / End Page

1644 / 1650

Related Subject Headings

  • Young Adult
  • Treatment Outcome
  • Tendon Injuries
  • Surveys and Questionnaires
  • Retrospective Studies
  • Patient Satisfaction
  • Orthopedics
  • Middle Aged
  • Male
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Greenwood, S. N., Adebayo, T., Reinke, E. K., Fletcher, A. N., Lewis, B. D., Scott, E. J., & Mather, R. C. (2026). Endoscopic Proximal Hamstring Repairs Remain Safe and Beneficial With High Patient Satisfaction at a Minimum of 6-Year Follow-Up. Arthroscopy : The Journal of Arthroscopic & Related Surgery : Official Publication of the Arthroscopy Association of North America and the International Arthroscopy Association, 42(9), 1644–1650. https://doi.org/10.1002/arj.70209
Greenwood, Shannon N., Temitope Adebayo, Emily K. Reinke, Amanda N. Fletcher, Brian D. Lewis, Elizabeth J. Scott, and Richard Charles Mather. “Endoscopic Proximal Hamstring Repairs Remain Safe and Beneficial With High Patient Satisfaction at a Minimum of 6-Year Follow-Up.” Arthroscopy : The Journal of Arthroscopic & Related Surgery : Official Publication of the Arthroscopy Association of North America and the International Arthroscopy Association 42, no. 9 (September 2026): 1644–50. https://doi.org/10.1002/arj.70209.
Greenwood SN, Adebayo T, Reinke EK, Fletcher AN, Lewis BD, Scott EJ, et al. Endoscopic Proximal Hamstring Repairs Remain Safe and Beneficial With High Patient Satisfaction at a Minimum of 6-Year Follow-Up. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2026 Sep;42(9):1644–50.
Greenwood, Shannon N., et al. “Endoscopic Proximal Hamstring Repairs Remain Safe and Beneficial With High Patient Satisfaction at a Minimum of 6-Year Follow-Up.” Arthroscopy : The Journal of Arthroscopic & Related Surgery : Official Publication of the Arthroscopy Association of North America and the International Arthroscopy Association, vol. 42, no. 9, Sept. 2026, pp. 1644–50. Epmc, doi:10.1002/arj.70209.
Greenwood SN, Adebayo T, Reinke EK, Fletcher AN, Lewis BD, Scott EJ, Mather RC. Endoscopic Proximal Hamstring Repairs Remain Safe and Beneficial With High Patient Satisfaction at a Minimum of 6-Year Follow-Up. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2026 Sep;42(9):1644–1650.
Journal cover image

Published In

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

DOI

EISSN

1526-3231

ISSN

0749-8063

Publication Date

September 2026

Volume

42

Issue

9

Start / End Page

1644 / 1650

Related Subject Headings

  • Young Adult
  • Treatment Outcome
  • Tendon Injuries
  • Surveys and Questionnaires
  • Retrospective Studies
  • Patient Satisfaction
  • Orthopedics
  • Middle Aged
  • Male
  • Humans