Filling the Gaps: Generating 4D Dense Cardiac Anatomy from Sparse CMR for Enhanced Tetralogy of Fallot Assessment.

Journal articles  - Journal Article
Mauger, C; Deng, Y; Xu, Y; Williams, MC; Williams, SE; Newby, DE; Campbell, MJ; Fadl, S; Simonetti, O; McCulloch, AD; Omens, J; Pushparajah, K ...
Published in: J Cardiovasc Magn Reson
June 16, 2026

BACKGROUND: Accurate assessment of 3D four chamber cardiac anatomy is essential for managing repaired Tetralogy of Fallot (rToF), yet standard cardiac magnetic resonance (CMR) protocols acquire sparse 2D slices with anisotropic resolution, inter-slice inconsistencies, and motion artifacts from patient movement and incomplete acquisitions. As CT provides isotropic 3D whole-heart segmentations, it can be used to train deep learning models to reconstruct dense 3D anatomies from sparse CMR-like slices simulated from these volumes, bridging the gap between CMR's clinical accessibility and CT's spatial resolution. We aimed to develop and validate such a deep learning pipeline for comprehensive 3D whole-heart reconstruction from routine 2D cine short and long axis CMR images in rToF patients. METHODS: A two-stage deep learning pipeline was developed to reconstruct cardiac anatomy from sparse two-dimensional cine (2D+time) CMR images. A UNet segmentation network was trained on 152 and tested on 19 held-out rToF patients from multiple centres. A label completion network reconstructed dense 3D geometries from sparse segmentations using 1,715 CT segmentations augmented with synthetic right ventricle (RV) myocardium and simulated ToF-specific views. The approach was validated using simulated slices from 18 3D non-contrast enhanced magnetic resonance angiography scans and clinical CMR scans. To simulate incomplete acquisitions encountered in paediatric clinical practice - where scans are frequently abandoned prematurely or individual views are missing due to patient motion or non-compliance - reconstruction performance was evaluated by randomly removing 50-70% of short-axis slices prior to 3D geometry reconstruction. RESULTS: With 50-70% of short-axis slices randomly removed, reconstruction achieved 3D Dice similarity coefficient (DSC) of 0.95 (left ventricle (LV)), 0.93 (right ventricle (RV)), 0.89 (LV myocardium), 0.89 (left atrium), 0.79 (right atrium), and 0.74 (RV myocardium). Chamber volumes and masses were accurately recovered: LV volume -0.27±1.60mL, RV volume 3.91±4.98mL, LA volume -2.32±3.33mL, LV mass -1.87±2.08g, RV mass 2.47±5.6g. On test CMR cases (n=19) with motion artifacts, 2D-DSC were 0.95±0.02 (LV cavity), 0.91±0.02 (RV cavity), 0.95±0.06 (LA cavity), 0.91±0.09 (RA cavity), 0.70±0.06 (RV myocardium) and 0.88±0.03 (LV myocardium), meeting or exceeding inter-observer variability. The network accurately reconstructed geometries throughout the cardiac cycle despite training only on diastasis hearts. CONCLUSIONS: This pipeline enables anatomically accurate cardiac anatomy from sparse CMR data, potentially reducing scan times while maintaining diagnostic accuracy.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Cardiovasc Magn Reson

DOI

EISSN

1532-429X

Publication Date

June 16, 2026

Start / End Page

102765

Location

England

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 3201 Cardiovascular medicine and haematology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mauger, C., Deng, Y., Xu, Y., Williams, M. C., Williams, S. E., Newby, D. E., … Young, A. (2026). Filling the Gaps: Generating 4D Dense Cardiac Anatomy from Sparse CMR for Enhanced Tetralogy of Fallot Assessment. J Cardiovasc Magn Reson, 102765. https://doi.org/10.1016/j.jocmr.2026.102765
Mauger, Charlène, Yu Deng, Yiyang Xu, Michelle C. Williams, Steven E. Williams, David E. Newby, M Jay Campbell, et al. “Filling the Gaps: Generating 4D Dense Cardiac Anatomy from Sparse CMR for Enhanced Tetralogy of Fallot Assessment.J Cardiovasc Magn Reson, June 16, 2026, 102765. https://doi.org/10.1016/j.jocmr.2026.102765.
Mauger C, Deng Y, Xu Y, Williams MC, Williams SE, Newby DE, et al. Filling the Gaps: Generating 4D Dense Cardiac Anatomy from Sparse CMR for Enhanced Tetralogy of Fallot Assessment. J Cardiovasc Magn Reson. 2026 Jun 16;102765.
Mauger, Charlène, et al. “Filling the Gaps: Generating 4D Dense Cardiac Anatomy from Sparse CMR for Enhanced Tetralogy of Fallot Assessment.J Cardiovasc Magn Reson, June 2026, p. 102765. Pubmed, doi:10.1016/j.jocmr.2026.102765.
Mauger C, Deng Y, Xu Y, Williams MC, Williams SE, Newby DE, Campbell MJ, Fadl S, Simonetti O, McCulloch AD, Omens J, Pushparajah K, Young A. Filling the Gaps: Generating 4D Dense Cardiac Anatomy from Sparse CMR for Enhanced Tetralogy of Fallot Assessment. J Cardiovasc Magn Reson. 2026 Jun 16;102765.
Journal cover image

Published In

J Cardiovasc Magn Reson

DOI

EISSN

1532-429X

Publication Date

June 16, 2026

Start / End Page

102765

Location

England

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 3201 Cardiovascular medicine and haematology