<p>Characterization of Bismuth-Coated Glassy Carbon Electrodes in Acidic Solvent Electrolytes for Enhanced Lead Detection</p>

Preprints
Jacobia, ER; Jones, A-AD
2026

Lead detection is needed to assess water quality risks, evaluate potential human exposure to lead, and guide effective resource allocation. Bismuth-coated electrodes have been employed for trace lead detection in drinking water samples because they can be made portable and are a safer alternative to mercury-based electrodes. Alternative electrolytes to the standard acetate buffer electrolyte can simplify the detection method and ensure the complete dissolution of particulate lead, a substantial portion of total lead, in drinking water samples. Acids are effective in dissolving particulate lead but are not common electrolytes for lead detection using bismuth-coated electrodes because it is hypothesized that they disrupt the coating. We tested this hypothesis in nitric, hydrochloric, acetate buffer, and sodium chloride electrolytes using square wave stripping voltammetry (SWSV), open circuit potential (OCP), cyclic voltammetry (CV), electrochemically active surface area calculations, and electrochemical impedance spectroscopy (EIS) to determine the electrochemical and electrical properties of bismuth-coated rotating disk electrodes in each. Nitric Acid had the lowest percent relative standard deviation (RSD) between lead peak repeated measures of the electrolytes (2.82 ± 0.947%), the highest OCP value (-0.0170 ± 0.0157 V), and moderate calculated electrochemically active surface area (0.0316 ± 0.0136 cm2) and roughness factor values (0.161 ± 0.069 cm2). Uncompensated resistance (168.82 ± 2.22 ohms) and polarization resistance (1387.41 ± 67.75 ohms) in nitric acid was low compared to the other electrolytes tested. Nitric acid had the highest EIS magnitude parameters for electrical surface distribution (5.5x10-4 ± 2.8x10-5 S•sα) and non-ideal capacitor coefficient (0.713 ± 0.006). The bismuth-coated electrode enabled a 60.3% increase in sensitivity compared to the bare electrode in nitric acid. We conclude that nitric acid is an effective alternative electrolyte for lead detection on bismuth-coated glassy carbon electrodes due to its low pH and minimal complexation with lead ions.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

DOI

Publication Date

2026
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Jacobia, E. R., & Jones, A.-A. (2026). <p>Characterization of Bismuth-Coated Glassy Carbon Electrodes in Acidic Solvent Electrolytes for Enhanced Lead Detection</p>. Elsevier BV. https://doi.org/10.2139/ssrn.7096330
Jacobia, Elizabeth R., and Akhenaton-Andrew Dhafir Jones. “<p>Characterization of Bismuth-Coated Glassy Carbon Electrodes in Acidic Solvent Electrolytes for Enhanced Lead Detection</p>.” Elsevier BV, 2026. https://doi.org/10.2139/ssrn.7096330.
Jacobia, Elizabeth R., and Akhenaton-Andrew Dhafir Jones. “<p>Characterization of Bismuth-Coated Glassy Carbon Electrodes in Acidic Solvent Electrolytes for Enhanced Lead Detection</p>.” Elsevier BV, 2026. Crossref, doi:10.2139/ssrn.7096330.