Skip to main content

Baseline QRS duration associates with cardiac recovery in patients with continuous-flow left ventricular assist device implantation.

Journal articles  - Journal Article
Khan, MS; Kyriakopoulos, CP; Taleb, I; Dranow, E; Scott, M; Ranjan, R; Yin, M; Tseliou, E; Alharethi, R; Caine, W; Shaw, RM; Selzman, CH ...
Published in: American heart journal plus : cardiology research and practice
October 2022

In chronic heart failure (HF) patients supported with continuous-flow left ventricular assist device (CF-LVAD), we aimed to assess the clinical association of pre-LVAD QRS duration (QRSd) with post-LVAD cardiac recovery, and its correlation with pre- to post-LVAD change in left ventricular ejection fraction (LVEF) and left ventricular end-diastolic diameter (LVEDD).Chronic HF patients (n = 402) undergoing CF-LVAD implantation were prospectively enrolled, at one of the centers comprising the U.T.A.H. (Utah Transplant Affiliated Hospitals) consortium. After excluding patients with acute HF etiologies, hypertrophic or infiltrative cardiomyopathy, and/or inadequate post-LVAD follow up (<3 months), 315 patients were included in the study. Cardiac recovery was defined as LVEF ≥ 40 % and LVEDD < 6 cm within 12 months post-LVAD implantation. Patients fulfilling this condition were termed as responders (R) and results were compared with non-responders (NR).Thirty-five patients (11 %) achieved 'R' criteria, and exhibited a 15 % shorter QRSd compared to 'NR' (123 ± 37 ms vs 145 ± 36 ms; p < 0.001). A univariate analysis identified association of baseline QRSd with post-LVAD cardiac recovery (OR: 0.986, 95 % CI: 0.976-0.996, p < 0.001). In a multivariate logistic regression model, after adjusting for duration of HF (OR: 0.990, 95 % CI: 0.983-0.997, p = 0.006) and gender (OR: 0.388, 95 % CI: 0.160-0.943, p = 0.037), pre-LVAD QRSd exhibited a significant association with post-LVAD cardiac structural and functional improvement (OR: 0.987, 95 % CI: 0.977-0.998, p = 0.027) and the predictive model showed a c-statistic of 0.73 with p < 0.001. The correlations for baseline QRSd with pre- to post-LVAD change in LVEF and LVEDD were also investigated in 'R' and 'NR' groups.Chronic advanced HF patients with a shorter baseline QRSd exhibit an increased potential for cardiac recovery after LVAD support.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

American heart journal plus : cardiology research and practice

DOI

EISSN

2666-6022

ISSN

2666-6022

Publication Date

October 2022

Volume

22

Start / End Page

100211
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Khan, M. S., Kyriakopoulos, C. P., Taleb, I., Dranow, E., Scott, M., Ranjan, R., … Dosdall, D. J. (2022). Baseline QRS duration associates with cardiac recovery in patients with continuous-flow left ventricular assist device implantation. American Heart Journal plus : Cardiology Research and Practice, 22, 100211. https://doi.org/10.1016/j.ahjo.2022.100211
Khan, Muhammad S., Christos P. Kyriakopoulos, Iosif Taleb, Elizabeth Dranow, Monte Scott, Ravi Ranjan, Michael Yin, et al. “Baseline QRS duration associates with cardiac recovery in patients with continuous-flow left ventricular assist device implantation.” American Heart Journal plus : Cardiology Research and Practice 22 (October 2022): 100211. https://doi.org/10.1016/j.ahjo.2022.100211.
Khan MS, Kyriakopoulos CP, Taleb I, Dranow E, Scott M, Ranjan R, et al. Baseline QRS duration associates with cardiac recovery in patients with continuous-flow left ventricular assist device implantation. American heart journal plus : cardiology research and practice. 2022 Oct;22:100211.
Khan, Muhammad S., et al. “Baseline QRS duration associates with cardiac recovery in patients with continuous-flow left ventricular assist device implantation.” American Heart Journal plus : Cardiology Research and Practice, vol. 22, Oct. 2022, p. 100211. Epmc, doi:10.1016/j.ahjo.2022.100211.
Khan MS, Kyriakopoulos CP, Taleb I, Dranow E, Scott M, Ranjan R, Yin M, Tseliou E, Alharethi R, Caine W, Shaw RM, Selzman CH, Drakos SG, Dosdall DJ. Baseline QRS duration associates with cardiac recovery in patients with continuous-flow left ventricular assist device implantation. American heart journal plus : cardiology research and practice. 2022 Oct;22:100211.

Published In

American heart journal plus : cardiology research and practice

DOI

EISSN

2666-6022

ISSN

2666-6022

Publication Date

October 2022

Volume

22

Start / End Page

100211