Skip to main content

Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task.

Journal articles  - Journal Article
Downs, ME; Buch, A; Sierra, C; Karakatsani, ME; Teichert, T; Chen, S; Konofagou, EE; Ferrera, VP
Published in: PloS one
January 2015

Focused Ultrasound (FUS) coupled with intravenous administration of microbubbles (MB) is a non-invasive technique that has been shown to reliably open (increase the permeability of) the blood-brain barrier (BBB) in multiple in vivo models including non-human primates (NHP). This procedure has shown promise for clinical and basic science applications, yet the safety and potential neurological effects of long term application in NHP requires further investigation under parameters shown to be efficacious in that species (500 kHz, 200-400 kPa, 4-5 μm MB, 2 minute sonication). In this study, we repeatedly opened the BBB in the caudate and putamen regions of the basal ganglia of 4 NHP using FUS with systemically-administered MB over 4-20 months. We assessed the safety of the FUS with MB procedure using MRI to detect edema or hemorrhaging in the brain. Contrast enhanced T1-weighted MRI sequences showed a 98% success rate for openings in the targeted regions. T2-weighted and SWI sequences indicated a lack edema in the majority of the cases. We investigated potential neurological effects of the FUS with MB procedure through quantitative cognitive testing of' visual, cognitive, motivational, and motor function using a random dot motion task with reward magnitude bias presented on a touchpanel display. Reaction times during the task significantly increased on the day of the FUS with MB procedure. This increase returned to baseline within 4-5 days after the procedure. Visual motion discrimination thresholds were unaffected. Our results indicate FUS with MB can be a safe method for repeated opening of the BBB at the basal ganglia in NHP for up to 20 months without any long-term negative physiological or neurological effects with the parameters used.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

PloS one

DOI

EISSN

1932-6203

ISSN

1932-6203

Publication Date

January 2015

Volume

10

Issue

5

Start / End Page

e0125911

Related Subject Headings

  • Task Performance and Analysis
  • Sonication
  • Safety
  • Microbubbles
  • Male
  • Magnetic Resonance Imaging
  • Macaca mulatta
  • Macaca fascicularis
  • General Science & Technology
  • Echoencephalography
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Downs, M. E., Buch, A., Sierra, C., Karakatsani, M. E., Teichert, T., Chen, S., … Ferrera, V. P. (2015). Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task. PloS One, 10(5), e0125911. https://doi.org/10.1371/journal.pone.0125911
Downs, Matthew E., Amanda Buch, Carlos Sierra, Maria Eleni Karakatsani, Tobias Teichert, Shangshang Chen, Elisa E. Konofagou, and Vincent P. Ferrera. “Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task.” PloS One 10, no. 5 (January 2015): e0125911. https://doi.org/10.1371/journal.pone.0125911.
Downs ME, Buch A, Sierra C, Karakatsani ME, Teichert T, Chen S, et al. Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task. PloS one. 2015 Jan;10(5):e0125911.
Downs, Matthew E., et al. “Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task.” PloS One, vol. 10, no. 5, Jan. 2015, p. e0125911. Epmc, doi:10.1371/journal.pone.0125911.
Downs ME, Buch A, Sierra C, Karakatsani ME, Teichert T, Chen S, Konofagou EE, Ferrera VP. Long-Term Safety of Repeated Blood-Brain Barrier Opening via Focused Ultrasound with Microbubbles in Non-Human Primates Performing a Cognitive Task. PloS one. 2015 Jan;10(5):e0125911.

Published In

PloS one

DOI

EISSN

1932-6203

ISSN

1932-6203

Publication Date

January 2015

Volume

10

Issue

5

Start / End Page

e0125911

Related Subject Headings

  • Task Performance and Analysis
  • Sonication
  • Safety
  • Microbubbles
  • Male
  • Magnetic Resonance Imaging
  • Macaca mulatta
  • Macaca fascicularis
  • General Science & Technology
  • Echoencephalography