Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings.
Publication
, Journal Article
Woodard, PK; Patz, EF; Sostman, HD
Published in: Journal of computer assisted tomography
November 1992
Pseudoaneurysm at the aortic cannulation site is a rare but potentially fatal complication of coronary artery bypass surgery. We present two cases in which MRI provided significant information regarding the anatomy and extent of a pseudoaneurysm. In one case both spin-echo imaging and cine MRI with and without gradient moment nulling (flow compensation) were used. The absence of gradient moment nulling in cine MRI provides additional contrast between flowing and static blood. This contrast may complement conventional cine images with gradient moment nulling, providing further information.
Published In
Journal of computer assisted tomography
DOI
EISSN
1532-3145
ISSN
0363-8715
Publication Date
November 1992
Volume
16
Issue
6
Start / End Page
883 / 887
Related Subject Headings
- Thrombosis
- Regional Blood Flow
- Nuclear Medicine & Medical Imaging
- Motion Pictures
- Male
- Magnetic Resonance Imaging
- Humans
- Coronary Artery Bypass
- Catheterization
- Blood Flow Velocity
Citation
APA
Chicago
ICMJE
MLA
NLM
Woodard, P. K., Patz, E. F., & Sostman, H. D. (1992). Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings. Journal of Computer Assisted Tomography, 16(6), 883–887. https://doi.org/10.1097/00004728-199211000-00010
Woodard, P. K., E. F. Patz, and H. D. Sostman. “Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings.” Journal of Computer Assisted Tomography 16, no. 6 (November 1992): 883–87. https://doi.org/10.1097/00004728-199211000-00010.
Woodard PK, Patz EF, Sostman HD. Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings. Journal of computer assisted tomography. 1992 Nov;16(6):883–7.
Woodard, P. K., et al. “Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings.” Journal of Computer Assisted Tomography, vol. 16, no. 6, Nov. 1992, pp. 883–87. Epmc, doi:10.1097/00004728-199211000-00010.
Woodard PK, Patz EF, Sostman HD. Pseudoaneurysms at aortic cannulation site after coronary artery bypass graft: MR findings. Journal of computer assisted tomography. 1992 Nov;16(6):883–887.
Published In
Journal of computer assisted tomography
DOI
EISSN
1532-3145
ISSN
0363-8715
Publication Date
November 1992
Volume
16
Issue
6
Start / End Page
883 / 887
Related Subject Headings
- Thrombosis
- Regional Blood Flow
- Nuclear Medicine & Medical Imaging
- Motion Pictures
- Male
- Magnetic Resonance Imaging
- Humans
- Coronary Artery Bypass
- Catheterization
- Blood Flow Velocity