Skip to main content

Optimizing light collection from thin scintillators used in a beta-ray camera for surgical use

Publication ,  Journal Article
Levin, CS; MacDonald, LR; Tornai, MP; Hoffman, EJ; Park, J
Published in: IEEE Transactions on Nuclear Science
December 1, 1996

We are developing a 1-2 cm2 area camera for imaging the distribution of beta-emitting radiopharmaceuticals at the surface of tissue exposed during surgery. The front end consists of a very thin continuous or segmented scintillator sensitive to betas (positrons or electrons) of a few hundred keV, yet insensitive to gamma rays. The light from the scintillator is piped through clear fibers to the photon detector (PD). This approach requires that a sufficient number of scintillation photons be transported from the scintillator, through the fibers to the PD. The scintillator. reflector, surface treatments, geometry, fiber light guides, and optical couplings must be optimized. We report here on efforts made to optimize the light collection from < 3 mm thick plastic and CaF2(Eu) scintillators into clear fibers using experimental measurements and computer simulations. We measured that with a 1.25 cm diameter, 0.5 mm thick optimized CaF2(Eu) disk coupled to a 5 cm long bundle of clear optical fibers, on average, ∼250 photoelectrons are produced at a PMT photocathode for a 204Tl beta flood source (Emax = 763 keV). This corresponds to a sufficient number of photoelectrons for ∼ 1 mm resolution imaging capabilities for the proposed camera. © 1996 IEEE.

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

December 1, 1996

Volume

43

Issue

3 PART 2

Start / End Page

2053 / 2060

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Levin, C. S., MacDonald, L. R., Tornai, M. P., Hoffman, E. J., & Park, J. (1996). Optimizing light collection from thin scintillators used in a beta-ray camera for surgical use. IEEE Transactions on Nuclear Science, 43(3 PART 2), 2053–2060. https://doi.org/10.1109/23.507268
Levin, C. S., L. R. MacDonald, M. P. Tornai, E. J. Hoffman, and J. Park. “Optimizing light collection from thin scintillators used in a beta-ray camera for surgical use.” IEEE Transactions on Nuclear Science 43, no. 3 PART 2 (December 1, 1996): 2053–60. https://doi.org/10.1109/23.507268.
Levin CS, MacDonald LR, Tornai MP, Hoffman EJ, Park J. Optimizing light collection from thin scintillators used in a beta-ray camera for surgical use. IEEE Transactions on Nuclear Science. 1996 Dec 1;43(3 PART 2):2053–60.
Levin, C. S., et al. “Optimizing light collection from thin scintillators used in a beta-ray camera for surgical use.” IEEE Transactions on Nuclear Science, vol. 43, no. 3 PART 2, Dec. 1996, pp. 2053–60. Scopus, doi:10.1109/23.507268.
Levin CS, MacDonald LR, Tornai MP, Hoffman EJ, Park J. Optimizing light collection from thin scintillators used in a beta-ray camera for surgical use. IEEE Transactions on Nuclear Science. 1996 Dec 1;43(3 PART 2):2053–2060.

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

December 1, 1996

Volume

43

Issue

3 PART 2

Start / End Page

2053 / 2060

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics