Physical phantom evaluation of EM-IntraSPECT (EMIS) algorithm for non-uniform attenuation correction in cardiac imaging
Publication
, Journal Article
Krol, A; Bowsher, JE; Feiglin, DH; Gagne, GM; Hellwig, BJ; Tornai, MP; Thomas, FD
Published in: Proceedings of SPIE-The International Society for Optical Engineering
January 1, 2001
The purpose of this study was to evaluate performance of the EM-IntraSPECT (EMIS) algorithm for non-uniform attenuation correction in the chest EMIS is a maximum-likelihood expectation maximization (MLEM) algorithm for simultaneously estimating SPECT emission and attenuation parameters from emission data alone. EMIS uses the activity within the patient as transmission tomography sources, with which attenuation coefficients can be estimated. A thorax phantom with a normal heart was used. The activity images reconstructed by EMIS were compared to images reconstructed using a conventional MLEM with a fixed uniform attenuation map. Uniformity of normal heart was improved with EMIS as compared to a conventional MLEM.
Published In
Proceedings of SPIE-The International Society for Optical Engineering
DOI
ISSN
0277-786X
Publication Date
January 1, 2001
Volume
4322
Issue
2
Start / End Page
934 / 938
Related Subject Headings
- 5102 Atomic, molecular and optical physics
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering
Citation
APA
Chicago
ICMJE
MLA
NLM
Krol, A., Bowsher, J. E., Feiglin, D. H., Gagne, G. M., Hellwig, B. J., Tornai, M. P., & Thomas, F. D. (2001). Physical phantom evaluation of EM-IntraSPECT (EMIS) algorithm for non-uniform attenuation correction in cardiac imaging. Proceedings of SPIE-The International Society for Optical Engineering, 4322(2), 934–938. https://doi.org/10.1117/12.430966
Krol, A., J. E. Bowsher, D. H. Feiglin, G. M. Gagne, B. J. Hellwig, M. P. Tornai, and F. D. Thomas. “Physical phantom evaluation of EM-IntraSPECT (EMIS) algorithm for non-uniform attenuation correction in cardiac imaging.” Proceedings of SPIE-The International Society for Optical Engineering 4322, no. 2 (January 1, 2001): 934–38. https://doi.org/10.1117/12.430966.
Krol A, Bowsher JE, Feiglin DH, Gagne GM, Hellwig BJ, Tornai MP, et al. Physical phantom evaluation of EM-IntraSPECT (EMIS) algorithm for non-uniform attenuation correction in cardiac imaging. Proceedings of SPIE-The International Society for Optical Engineering. 2001 Jan 1;4322(2):934–8.
Krol, A., et al. “Physical phantom evaluation of EM-IntraSPECT (EMIS) algorithm for non-uniform attenuation correction in cardiac imaging.” Proceedings of SPIE-The International Society for Optical Engineering, vol. 4322, no. 2, Jan. 2001, pp. 934–38. Scopus, doi:10.1117/12.430966.
Krol A, Bowsher JE, Feiglin DH, Gagne GM, Hellwig BJ, Tornai MP, Thomas FD. Physical phantom evaluation of EM-IntraSPECT (EMIS) algorithm for non-uniform attenuation correction in cardiac imaging. Proceedings of SPIE-The International Society for Optical Engineering. 2001 Jan 1;4322(2):934–938.
Published In
Proceedings of SPIE-The International Society for Optical Engineering
DOI
ISSN
0277-786X
Publication Date
January 1, 2001
Volume
4322
Issue
2
Start / End Page
934 / 938
Related Subject Headings
- 5102 Atomic, molecular and optical physics
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering