Skip to main content

Characterization of fluor concentration and geometry in organic scintillators for in situ beta imaging

Publication ,  Journal Article
Tornai, MP; Huffman, EJ
Published in: IEEE Transactions on Nuclear Science
January 1, 1996

Development of a small area (1-2 cm2 ) in situ beta imaging device includes optimization of the front end scintillation detector, which is fiber optically coupled to a remote photon detector. Thin plastic scintillation detectors, which are sensitive to charged particles, are the ideal detectors due to the low sensitivity to ambient gamma backgrounds. The light output of a new binary plastic scintillator was investigated with respect to increasing concentrations of the fluor (0.5-2.0% by weight) and varying thickness cylindrical configurations of the intended imaging detector. The fluor had an emission maximum increasing from 431 to 436 nm with increasing fluor concentration. The decay time(s) had two components (0.38 and 1.74 ns). There was an ~20% increase in light output with increasing fluor concentration, measured with both 204T1 betas and conversion electrons from 207Bi. The highest light output of this new scintillator was measured to be ~30% lower than BC404. Simulations predicted the 1.5 mm scintillator thickness at which light output and energy absorption for ~700 keV electrons (e.g., from 204T1, 18F) were maximized, which corresponded with measurements. As beta continua are relatively featureless, energy calibration for the thin scintillators was investigated using Landau distributions, which appear as distinct peaks in the spectra. As the scintillators were made thinner, gamma backgrounds were shown to linearly decrease. © 1996 IEEE.

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

January 1, 1996

Volume

43

Issue

6 PART 2

Start / End Page

3342 / 3347

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tornai, M. P., & Huffman, E. J. (1996). Characterization of fluor concentration and geometry in organic scintillators for in situ beta imaging. IEEE Transactions on Nuclear Science, 43(6 PART 2), 3342–3347. https://doi.org/10.1109/23.552749
Tornai, M. P., and E. J. Huffman. “Characterization of fluor concentration and geometry in organic scintillators for in situ beta imaging.” IEEE Transactions on Nuclear Science 43, no. 6 PART 2 (January 1, 1996): 3342–47. https://doi.org/10.1109/23.552749.
Tornai MP, Huffman EJ. Characterization of fluor concentration and geometry in organic scintillators for in situ beta imaging. IEEE Transactions on Nuclear Science. 1996 Jan 1;43(6 PART 2):3342–7.
Tornai, M. P., and E. J. Huffman. “Characterization of fluor concentration and geometry in organic scintillators for in situ beta imaging.” IEEE Transactions on Nuclear Science, vol. 43, no. 6 PART 2, Jan. 1996, pp. 3342–47. Scopus, doi:10.1109/23.552749.
Tornai MP, Huffman EJ. Characterization of fluor concentration and geometry in organic scintillators for in situ beta imaging. IEEE Transactions on Nuclear Science. 1996 Jan 1;43(6 PART 2):3342–3347.

Published In

IEEE Transactions on Nuclear Science

DOI

ISSN

0018-9499

Publication Date

January 1, 1996

Volume

43

Issue

6 PART 2

Start / End Page

3342 / 3347

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics