Recommendations for the use of mechanical circulatory support: device strategies and patient selection: a scientific statement from the American Heart Association.

Publication ,  Journal Article
Peura, JL; Colvin-Adams, M; Francis, GS; Grady, KL; Hoffman, TM; Jessup, M; John, R; Kiernan, MS; Mitchell, JE; O'Connell, JB; Pagani, FD ...
Published in: Circulation
November 27, 2012

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

November 27, 2012

Volume

126

Issue

22

Start / End Page

2648 / 2667

Location

United States

Related Subject Headings

  • United States
  • Patient Selection
  • Intra-Aortic Balloon Pumping
  • Humans
  • Heart, Artificial
  • Heart Failure
  • Extracorporeal Membrane Oxygenation
  • Cardiovascular System & Hematology
  • Cardiology
  • American Heart Association
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Peura, J. L., Colvin-Adams, M., Francis, G. S., Grady, K. L., Hoffman, T. M., Jessup, M., … Council on Cardiovascular Radiology and Intervention, and Council on Cardiovascular Surgery and Anesthesia, . (2012). Recommendations for the use of mechanical circulatory support: device strategies and patient selection: a scientific statement from the American Heart Association. Circulation, 126(22), 2648–2667. https://doi.org/10.1161/CIR.0b013e3182769a54
Peura, Jennifer L., Monica Colvin-Adams, Gary S. Francis, Kathleen L. Grady, Timothy M. Hoffman, Mariell Jessup, Ranjit John, et al. “Recommendations for the use of mechanical circulatory support: device strategies and patient selection: a scientific statement from the American Heart Association.Circulation 126, no. 22 (November 27, 2012): 2648–67. https://doi.org/10.1161/CIR.0b013e3182769a54.
Peura JL, Colvin-Adams M, Francis GS, Grady KL, Hoffman TM, Jessup M, et al. Recommendations for the use of mechanical circulatory support: device strategies and patient selection: a scientific statement from the American Heart Association. Circulation. 2012 Nov 27;126(22):2648–67.
Peura, Jennifer L., et al. “Recommendations for the use of mechanical circulatory support: device strategies and patient selection: a scientific statement from the American Heart Association.Circulation, vol. 126, no. 22, Nov. 2012, pp. 2648–67. Pubmed, doi:10.1161/CIR.0b013e3182769a54.
Peura JL, Colvin-Adams M, Francis GS, Grady KL, Hoffman TM, Jessup M, John R, Kiernan MS, Mitchell JE, O’Connell JB, Pagani FD, Petty M, Ravichandran P, Rogers JG, Semigran MJ, Toole JM, American Heart Association Heart Failure and Transplantation Committee of the Council on Clinical Cardiology, Council on Cardiopulmonary, Critical Care, Perioperative and Resuscitation, Council on Cardiovascular Disease in the Young, Council on Cardiovascular Nursing, Council on Cardiovascular Radiology and Intervention, and Council on Cardiovascular Surgery and Anesthesia. Recommendations for the use of mechanical circulatory support: device strategies and patient selection: a scientific statement from the American Heart Association. Circulation. 2012 Nov 27;126(22):2648–2667.

Published In

Circulation

DOI

EISSN

1524-4539

Publication Date

November 27, 2012

Volume

126

Issue

22

Start / End Page

2648 / 2667

Location

United States

Related Subject Headings

  • United States
  • Patient Selection
  • Intra-Aortic Balloon Pumping
  • Humans
  • Heart, Artificial
  • Heart Failure
  • Extracorporeal Membrane Oxygenation
  • Cardiovascular System & Hematology
  • Cardiology
  • American Heart Association