Frequency content analysis and filter class selection for the small female instrumented upper extremity
Publication
, Journal Article
Stitzel, J; Duma, S; Boggess, B; Bass, C; Crandall, J
Published in: SAE Technical Papers
January 1, 2002
Although filter class specifications have been defined for most anthropomorphic test devices, no recommendation exists for the instrumented upper extremity. A three-part study was performed to determine the best channel filter class (CFC) to use for the instrumented upper extremity. By analyzing frequency content of signals from accelerometers and load cells, filtering data through three of the four possible CFC's to compare effects on the signals, and performing an injury comparison between cadaver data and the filtered load cell data, CFC 600 was chosen and recommended as the optimum filter class to use for upper extremity testing. Copyright © 2002 Society of Automotive Engineers, Inc.
Duke Scholars
Published In
SAE Technical Papers
DOI
EISSN
2688-3627
ISSN
0148-7191
Publication Date
January 1, 2002
Related Subject Headings
- 4014 Manufacturing engineering
- 4002 Automotive engineering
- 0910 Manufacturing Engineering
- 0902 Automotive Engineering
Citation
APA
Chicago
ICMJE
MLA
NLM
Stitzel, J., Duma, S., Boggess, B., Bass, C., & Crandall, J. (2002). Frequency content analysis and filter class selection for the small female instrumented upper extremity. SAE Technical Papers. https://doi.org/10.4271/2002-01-0806
Stitzel, J., S. Duma, B. Boggess, C. Bass, and J. Crandall. “Frequency content analysis and filter class selection for the small female instrumented upper extremity.” SAE Technical Papers, January 1, 2002. https://doi.org/10.4271/2002-01-0806.
Stitzel J, Duma S, Boggess B, Bass C, Crandall J. Frequency content analysis and filter class selection for the small female instrumented upper extremity. SAE Technical Papers. 2002 Jan 1;
Stitzel, J., et al. “Frequency content analysis and filter class selection for the small female instrumented upper extremity.” SAE Technical Papers, Jan. 2002. Scopus, doi:10.4271/2002-01-0806.
Stitzel J, Duma S, Boggess B, Bass C, Crandall J. Frequency content analysis and filter class selection for the small female instrumented upper extremity. SAE Technical Papers. 2002 Jan 1;
Published In
SAE Technical Papers
DOI
EISSN
2688-3627
ISSN
0148-7191
Publication Date
January 1, 2002
Related Subject Headings
- 4014 Manufacturing engineering
- 4002 Automotive engineering
- 0910 Manufacturing Engineering
- 0902 Automotive Engineering