G. Allan Johnson
Charles E. Putman University Distinguished Professor of Radiology
Dr. Johnson is the Charles E. Putman University Professor of Radiology, Professor of Physics, and Biomedical Engineering, and Director of the Duke Center for In Vivo Microscopy (CIVM). The CIVM is an NIH/NIBIB national Biomedical Technology Resource Center with a mission to develop novel technologies for preclinical imaging (basic sciences) and apply the technologies to critical biomedical questions. Dr. Johnson was one of the first researchers to bring Paul Lauterbur's vision of magnetic resonance (MR) microscopy to practice as described in his paper, "Nuclear magnetic resonance imaging at microscopic resolution" (J Magn Reson 68:129-137, 1986). Dr. Johnson is involved in both the engineering physics required to extend the resolution of MR imaging and in a broad range of applications in the basic sciences.
Office Hours
8:30 AM-5:00 PM and by appointment.
Current Appointments & Affiliations
- Charles E. Putman University Distinguished Professor of Radiology, Radiology, Clinical Science Departments 2002
- Professor of Radiology, Radiology, Clinical Science Departments 2018
- Professor in the Department of Physics, Physics, Trinity College of Arts & Sciences 1993
- Professor of Biomedical Engineering, Biomedical Engineering, Pratt School of Engineering 2021
- Member of the Duke Cancer Institute, Duke Cancer Institute, Institutes and Centers 1974
Contact Information
- 141D Bryan Neuroscience Bldg, Research Drive, Durham, NC 27710
- Box 3302 Med Ctr, Durham, NC 27710
-
gjohnson@duke.edu
(919) 684-7754
-
Center for In Vivo Microscopy
- Background
-
Education, Training, & Certifications
- Ph.D., Duke University 1974
-
Previous Appointments & Affiliations
- Professor of Radiology, Radiology, Clinical Science Departments 1988 - 2018
- Professor of Biomedical Engineering, Biomedical Engineering, Pratt School of Engineering 2003 - 2013
- Head, Section of Imaging Physics, Radiology, Clinical Science Departments 1979 - 2011
- Professor of Biomedical Engineering, Biomedical Engineering, Pratt School of Engineering 1995 - 1999
- Recognition
-
In the News
-
APR 17, 2023 Duke Today -
NOV 15, 2021 -
SEP 15, 2015 Duke Today
-
- Expertise
-
Subject Headings
- Age Factors
- Aging
- Alzheimer Disease
- Angiography, Digital Subtraction
- Animals
- Anisotropy
- Aorta
- Artifacts
- Atlases as Topic
- Bayes Theorem
- Biological Markers
- Blast Injuries
- Blood Flow Velocity
- Blood-Brain Barrier
- Brain
- Brain Diseases
- Brain Injuries
- Brain Mapping
- Cardiac-Gated Imaging Techniques
- Cardiovascular System
- Cell Line, Tumor
- Central Nervous System
- Cerebellar Nuclei
- Cerebral Cortex
- Computer Graphics
- Computer Simulation
- Computer Systems
- Computers
- Contrast Media
- Coronary Vessels
- Databases, Factual
- Diagnostic Imaging
- Diffusion
- Diffusion Tensor Imaging
- Disease Models, Animal
- Disease Susceptibility
- Dose-Response Relationship, Drug
- Drug Evaluation, Preclinical
- Echo-Planar Imaging
- Electromagnetic Fields
- Electromagnetic Phenomena
- Embryo, Mammalian
- Equipment Design
- Female
- Fetal Alcohol Syndrome
- Fiber Optic Technology
- Fibrosis
- Four-Dimensional Computed Tomography
- Fourier Analysis
- Gadolinium
- Gadolinium DTPA
- Genotype
- Heart
- Heart Rate
- Helium
- Histological Techniques
- Histology
- Humans
- Image Enhancement
- Image Interpretation, Computer-Assisted
- Image Processing, Computer-Assisted
- Imaging
- Imaging, Three-Dimensional
- Immunohistochemistry
- Infarction, Middle Cerebral Artery
- Informatics
- Information Dissemination
- Intubation
- Iodine
- Kidney
- Kidney Cortex
- Kidney Diseases
- Kidney Glomerulus
- Kidney Medulla
- Least-Squares Analysis
- Liposomes
- Liver
- Magnetic Resonance Angiography
- Magnetic Resonance Imaging
- Magnetic Resonance Spectroscopy
- Magnetic susceptibility
- Magnetics
- Magnetite Nanoparticles
- Manganese
- Manganese Compounds
- Methods
- Mice
- Mice, Inbred BALB C
- Mice, Inbred C57BL
- Mice, Inbred Strains
- Mice, Knockout
- Mice, Neurologic Mutants
- Mice, Nude
- Microbubbles
- Microcirculation
- Microscopy
- Microscopy, Confocal
- Microscopy, Electron, Scanning
- Models, Anatomic
- Models, Animal
- Models, Biological
- Models, Cardiovascular
- Models, Neurological
- Models, Statistical
- Molecular Imaging
- Monitoring, Physiologic
- Multiple Sclerosis
- Muser Mentor
- Myocardial Contraction
- Myocardial Infarction
- Nanoparticles
- Nervous System
- Neural Pathways
- Noble Gases
- Nuclear magnetic resonance
- Optical Imaging
- Pathology
- Perfusion
- Perfusion Imaging
- Phantoms, Imaging
- Phenotype
- Protons
- Pulmonary Artery
- Pulmonary Circulation
- Pulmonary Diffusing Capacity
- Pulmonary Fibrosis
- Pulmonary Gas Exchange
- Putamen
- Radiation Dosage
- Radiation Injuries, Experimental
- Radiographic Image Enhancement
- Radiographic Image Interpretation, Computer-Assisted
- Radiography, Thoracic
- Rats
- Rats, Inbred F344
- Rats, Sprague-Dawley
- Reference Standards
- Respiration
- Respiratory Mechanics
- Retrospective Studies
- Rubidium
- Signal Processing, Computer-Assisted
- Software
- Spatio-Temporal Analysis
- Specimen Handling
- Spectrometry, Fluorescence
- Staining and Labeling
- Stereotaxic Techniques
- Substantia Nigra
- Subtraction Technique
- Technology, Radiologic
- Tissue Fixation
- Tomography
- Tomography Scanners, X-Ray Computed
- Tomography, Emission-Computed, Single-Photon
- Tomography, Optical
- Tomography, X-Ray Computed
- Toxicology
- Tumor Burden
- Tumor Microenvironment
- Ultrasonics
- Ultrasonography, Doppler, Transcranial
- Ventilation-Perfusion Ratio
- Ventilators, Mechanical
- Ventricular Function, Left
- X-Ray Microtomography
- X-Rays
- Xenon Isotopes
- Xenon Radioisotopes
-
Global Scholarship
-
Expertise
-
- Research
-
Selected Grants
- Mapping the Autonomic Pathways across 100 Human Vagus Nerves within a Demographically Representative Sample (MAP-100VN) awarded by Case Western Reserve University 2022 - 2025
- Imaging Genetics of Brain Structure and Cognitive Aging in Murine Models of Alzheimer's Disease awarded by University of Tennessee Health Science Center 2021 - 2024
- Ultra-high Resolution Structural Connectome Atlases of the Animal Brain and their Associated Toolbox awarded by University of Pittsburgh 2022 - 2023
- A console for magnetic resonance histology awarded by North Carolina Biotechnology Center 2021 - 2023
- The Duke Pre-Clinical Research Resources for Quantitative Imaging Biomarkers awarded by National Institutes of Health 2017 - 2023
- Zeiss Lightsheet Upgrade to Expand Imaging Capabilities awarded by National Institutes of Health 2021 - 2022
- Transmission electron microscope (TEM) awarded by National Institutes of Health 2019 - 2021
- Waxholm Space for Rodent Neuroinformatics awarded by University of Pennsylvania 2016 - 2020
- Training in Medical Imaging awarded by National Institutes of Health 2003 - 2020
- Neuronal Networks in Traumatic Brain Injury of ApoE Mice awarded by Durham Veterans Affairs Medical Center 2019
- Quantitative MR Microscopy of Phenotypic Biomarkers in Alzheimer's Disease awarded by National Institutes of Health 2013 - 2018
- Integrated Center For In Vivo Microscopy awarded by National Institutes of Health 2003 - 2018
- Serial Block Face Scanning Electron Microscope awarded by National Institutes of Health 2016 - 2018
- Ultra-resolution imaging of brain circuitry and its development in mental health awarded by National Institutes of Health 2013 - 2016
- MRI Corticography (MRCoG): Micro-scale Human Cortical Imaging awarded by University of California - Berkeley 2014 - 2016
- Prevention of Temporal Lobe Epilepsy awarded by National Institutes of Health 2012 - 2015
- Whole brain multimodal microscopy of an apoptosis reporter mouse awarded by National Institutes of Health 2012 - 2014
- Time-Resolved 129Xe Ventilation-Perfusion MRI in Rat Models of Acute Lung Injury awarded by National Institutes of Health 2012 - 2014
- Agilent Direct Drive 9.4T MRS/MRI Console awarded by National Institutes of Health 2012 - 2013
- Cross-disciplinary Training in Medical Physics awarded by National Institutes of Health 2007 - 2013
- Regulation of mitochondrial biogenesis by heme oxygenase-1 awarded by National Institutes of Health 2008 - 2013
- Small Animal Imaging Resource Program awarded by National Institutes of Health 2001 - 2012
- The Role of PTEN in Endothelial Biology awarded by National Institutes of Health 2008 - 2012
- The Duke University Molecular Imaging Center awarded by National Institutes of Health 2001 - 2006
- Functional Assessment of Pulmonary Toxicity with MRM awarded by National Institutes of Health 1996 - 2006
- Supp. to P41 - A Mouse Brain Imaging Research Network awarded by National Institutes of Health 2001 - 2003
- Integrated Center for InVivo Microscopy awarded by National Institutes of Health 1998 - 2003
- Developmental correlates-membrane/contractile protein. awarded by National Institutes of Health 1997 - 2001
- Small Animal Imaging in the Basic Sciences Workshop awarded by National Institutes of Health 1999
- In Vivo Microscopy Of Environmental Lung Disease awarded by National Institutes of Health 1997 - 1999
- In Vivo Microscopy Of Enviromental Lung Disease awarded by National Institutes of Health 1996 - 1999
- Integrated Center For In Vivo Microscopy awarded by National Institutes of Health 1990 - 1998
- Effects of Spatial Inhomogeneity on Nonlinear Pattern Forming Systems awarded by National Science Foundation 1997 - 1998
- Experimental and Analytical Investigations of Flows in Porous Media awarded by National Science Foundation 1994 - 1997
- An Integrated Center For In Vivo Microscopy awarded by National Institutes of Health 1990 - 1996
- Experimental and Analytical Investigation of Flows in Porous Media awarded by National Science Foundation 1994 - 1996
- Experimental and Analytical Investigations of Flows in Porous Media awarded by Department of Energy 1990 - 1996
- In Vivo Assay Of Environmental Toxins With Mr Microscopy awarded by National Institutes of Health 1993 - 1995
- In Vivo Assay Of Environmental Toxins With Mri awarded by National Institutes of Health 1992 - 1994
- Analytical and Experimental Study of Instabilities in Buoyancy-driven Convection in Porous Media awarded by National Science Foundation 1990 - 1993
- An Integrated Image Processing/Analysis Network awarded by National Institutes of Health 1988 - 1990
- Nuclear Magnetic Resonance (Nmr) Imaging Facility awarded by National Institutes of Health 1986 - 1989
- Nuclear Magnetic Resonance Imaging Facility For Small Anim awarded by National Institutes of Health 1984 - 1986
- Publications & Artistic Works
-
Selected Publications
-
Books
-
Paxinos, G., Watson, C., Calabrese, E., Badea, A., & Johnson, G. (2015). An MRI/DTI Atlas of the Rat Brain. Elsevier, Academic Press.
-
-
Academic Articles
-
Johnson, G. A., Tian, Y., Ashbrook, D. G., Cofer, G. P., Cook, J. J., Gee, J. C., … Williams, R. W. (2023). Merged magnetic resonance and light sheet microscopy of the whole mouse brain. Proc Natl Acad Sci U S A, 120(17), e2218617120. https://doi.org/10.1073/pnas.2218617120Full Text Link to Item
-
Hornburg, K. J., Slosky, L. M., Cofer, G., Cook, J., Qi, Y., Porkka, F., … Johnson, G. A. (2023). Prenatal heroin exposure alters brain morphology and connectivity in adolescent mice. Nmr Biomed, 36(2), e4842. https://doi.org/10.1002/nbm.4842Full Text Link to Item
-
Crater, S., Maharjan, S., Qi, Y., Zhao, Q., Cofer, G., Cook, J. C., … Wang, N. (2022). Resolution and b value dependent structural connectome in ex vivo mouse brain. Neuroimage, 255, 119199. https://doi.org/10.1016/j.neuroimage.2022.119199Full Text Link to Item
-
Du, E. Y., Ortega, B. K., Ninoyu, Y., Williams, R. W., Cofer, G. P., Cook, J. J., … Friedman, R. A. (2022). Volumetric analysis of the aging auditory pathway using high resolution magnetic resonance histology. Front Aging Neurosci, 14, 1034073. https://doi.org/10.3389/fnagi.2022.1034073Full Text Link to Item
-
Nicholls, P. J., Pack, T. F., Urs, N. M., Kumar, S., Zhou, Y., Ichim, G., … Caron, M. G. (2022). Measuring Nonapoptotic Caspase Activity with a Transgenic Reporter in Mice. Eneuro, 9(5). https://doi.org/10.1523/ENEURO.0147-21.2022Full Text Link to Item
-
Shen, J., Zhao, Q., Qi, Y., Cofer, G., Johnson, G. A., & Wang, N. (2022). Tractography of Porcine Meniscus Microstructure Using High-Resolution Diffusion Magnetic Resonance Imaging. Frontiers in Endocrinology, 13, 876784. https://doi.org/10.3389/fendo.2022.876784Full Text
-
Sitek, K. R., Calabrese, E., Johnson, G. A., Ghosh, S. S., & Chandrasekaran, B. (2022). Structural Connectivity of Human Inferior Colliculus Subdivisions Using in vivo and post mortem Diffusion MRI Tractography. Front Neurosci, 16, 751595. https://doi.org/10.3389/fnins.2022.751595Full Text Link to Item
-
Tian, Y., Cook, J. J., & Johnson, G. A. (2022). Restoring morphology of light sheet microscopy data based on magnetic resonance histology. Front Neurosci, 16, 1011895. https://doi.org/10.3389/fnins.2022.1011895Full Text Link to Item
-
Xiao, J., Hornburg, K. J., Cofer, G., Cook, J. J., Pratson, F., Qi, Y., & Johnson, G. A. (2022). A time-course study of actively stained mouse brains: Diffusion tensor imaging parameters and connectomic stability over 1 year. Nmr Biomed, 35(1), e4611. https://doi.org/10.1002/nbm.4611Full Text Link to Item
-
Johnson, G. A., Laoprasert, R., Anderson, R. J., Cofer, G., Cook, J., Pratson, F., & White, L. E. (2021). A multicontrast MR atlas of the Wistar rat brain. Neuroimage, 242, 118470. https://doi.org/10.1016/j.neuroimage.2021.118470Full Text Link to Item
-
Adil, S. M., Calabrese, E., Charalambous, L. T., Cook, J. J., Rahimpour, S., Atik, A. F., … White, L. E. (2021). A high-resolution interactive atlas of the human brainstem using magnetic resonance imaging. Neuroimage, 237, 118135. https://doi.org/10.1016/j.neuroimage.2021.118135Full Text Link to Item
-
Nair, K. S., Srivastava, C., Brown, R. V., Koli, S., Choquet, H., Kang, H. S., … Jetten, A. M. (2021). GLIS1 regulates trabecular meshwork function and intraocular pressure and is associated with glaucoma in humans. Nat Commun, 12(1), 4877. https://doi.org/10.1038/s41467-021-25181-7Full Text Link to Item
-
Garrett, A., Rakhilin, N., Wang, N., McKey, J., Cofer, G., Anderson, R. B., … Shen, X. (2021). Mapping the peripheral nervous system in the whole mouse via compressed sensing tractography. J Neural Eng, 18(4). https://doi.org/10.1088/1741-2552/ac0089Full Text Link to Item
-
Blocker, S. J., Cook, J., Mowery, Y. M., Everitt, J. I., Qi, Y., Hornburg, K. J., … Johnson, G. A. (2021). Ex Vivo MR Histology and Cytometric Feature Mapping Connect Three-dimensional in Vivo MR Images to Two-dimensional Histopathologic Images of Murine Sarcomas. Radiol Imaging Cancer, 3(3), e200103. https://doi.org/10.1148/rycan.2021200103Full Text Open Access Copy Link to Item
-
Badea, A., Schmalzigaug, R., Kim, W., Bonner, P., Ahmed, U., Johnson, G. A., … Premont, R. T. (2021). Microcephaly with altered cortical layering in GIT1 deficiency revealed by quantitative neuroimaging. Magn Reson Imaging, 76, 26–38. https://doi.org/10.1016/j.mri.2020.09.023Full Text Link to Item
-
Sills, R. C., Johnson, G. A., Anderson, R. J., Johnson, C. L., Staup, M., Brown, D. L., … Little, P. B. (2020). Qualitative and Quantitative Neuropathology Approaches Using Magnetic Resonance Microscopy (Diffusion Tensor Imaging) and Stereology in a Hexachlorophene Model of Myelinopathy in Sprague-Dawley Rats. Toxicol Pathol, 48(8), 965–980. https://doi.org/10.1177/0192623320968210Full Text Link to Item
-
Wang, N., Anderson, R. J., Ashbrook, D. G., Gopalakrishnan, V., Park, Y., Priebe, C. E., … Johnson, G. A. (2020). Variability and heritability of mouse brain structure: Microscopic MRI atlases and connectomes for diverse strains. Neuroimage, 222, 117274. https://doi.org/10.1016/j.neuroimage.2020.117274Full Text Link to Item
-
Halem, H. A., Hochgeschwender, U., Rih, J. K., Nelson, R., Johnson, G. A., Thiagalingam, A., & Culler, M. D. (2020). TBR-760, a Dopamine-Somatostatin Compound, Arrests Growth of Aggressive Nonfunctioning Pituitary Adenomas in Mice. Endocrinology, 161(8). https://doi.org/10.1210/endocr/bqaa101Full Text Link to Item
-
Wang, N., Mirando, A. J., Cofer, G., Qi, Y., Hilton, M. J., & Johnson, G. A. (2020). Characterization complex collagen fiber architecture in knee joint using high-resolution diffusion imaging. Magn Reson Med, 84(2), 908–919. https://doi.org/10.1002/mrm.28181Full Text Open Access Copy Link to Item
-
Wang, N., White, L. E., Qi, Y., Cofer, G., & Johnson, G. A. (2020). Cytoarchitecture of the mouse brain by high resolution diffusion magnetic resonance imaging. Neuroimage, 216, 116876. https://doi.org/10.1016/j.neuroimage.2020.116876Full Text Link to Item
-
Anderson, R. J., Long, C. M., Calabrese, E. D., Robertson, S. H., Johnson, G. A., Cofer, G. P., … Badea, A. (2020). Optimizing Diffusion Imaging Protocols for Structural Connectomics in Mouse Models of Neurological Conditions. Front Phys, 8. https://doi.org/10.3389/fphy.2020.00088Full Text Link to Item
-
Holbrook, M. D., Blocker, S. J., Mowery, Y. M., Badea, A., Qi, Y., Xu, E. S., … Badea, C. T. (2020). MRI-Based Deep Learning Segmentation and Radiomics of Sarcoma in Mice. Tomography, 6(1), 23–33. https://doi.org/10.18383/j.tom.2019.00021Full Text Open Access Copy Link to Item
-
Rushmore, R. J., Wilson-Braun, P., Papadimitriou, G., Ng, I., Rathi, Y., Zhang, F., … Makris, N. (2020). 3D Exploration of the Brainstem in 50-Micron Resolution MRI. Front Neuroanat, 14, 40. https://doi.org/10.3389/fnana.2020.00040Full Text Link to Item
-
Allan Johnson, G., Wang, N., Anderson, R. J., Chen, M., Cofer, G. P., Gee, J. C., … White, L. E. (2019). Whole mouse brain connectomics. J Comp Neurol, 527(13), 2146–2157. https://doi.org/10.1002/cne.24560Full Text Link to Item
-
Atik, A. F., Calabrese, E., Gramer, R., Adil, S. M., Rahimpour, S., Pagadala, P., … Lad, S. P. (2019). Structural mapping with fiber tractography of the human cuneate fasciculus at microscopic resolution in cervical region. Neuroimage, 196, 200–206. https://doi.org/10.1016/j.neuroimage.2019.04.030Full Text Link to Item
-
Sitek, K. R., Gulban, O. F., Calabrese, E., Johnson, G. A., Lage-Castellanos, A., Moerel, M., … De Martino, F. (2019). Mapping the human subcortical auditory system using histology, postmortem MRI and in vivo MRI at 7T. Elife, 8. https://doi.org/10.7554/eLife.48932Full Text Link to Item
-
Anderson, R. J., Cook, J. J., Delpratt, N., Nouls, J. C., Gu, B., McNamara, J. O., … Badea, A. (2019). Small Animal Multivariate Brain Analysis (SAMBA) - a High Throughput Pipeline with a Validation Framework. Neuroinformatics, 17(3), 451–472. https://doi.org/10.1007/s12021-018-9410-0Full Text Link to Item
-
Wang, N., Mirando, A. J., Cofer, G., Qi, Y., Hilton, M. J., & Johnson, G. A. (2019). Diffusion tractography of the rat knee at microscopic resolution. Magn Reson Med, 81(6), 3775–3786. https://doi.org/10.1002/mrm.27652Full Text Link to Item
-
Wang, N., Zhang, J., Cofer, G., Qi, Y., Anderson, R. J., White, L. E., & Allan Johnson, G. (2019). Neurite orientation dispersion and density imaging of mouse brain microstructure. Brain Struct Funct, 224(5), 1797–1813. https://doi.org/10.1007/s00429-019-01877-xFull Text Link to Item
-
Privratsky, J. R., Wang, N., Qi, Y., Ren, J., Morris, B. T., Hunting, J. C., … Crowley, S. D. (2019). Dynamic contrast-enhanced MRI promotes early detection of toxin-induced acute kidney injury. Am J Physiol Renal Physiol, 316(2), F351–F359. https://doi.org/10.1152/ajprenal.00416.2018Full Text Link to Item
-
Badea, A., Wu, W., Shuff, J., Wang, M., Anderson, R. J., Qi, Y., … Dunson, D. B. (2019). Identifying Vulnerable Brain Networks in Mouse Models of Genetic Risk Factors for Late Onset Alzheimer's Disease. Front Neuroinform, 13, 72. https://doi.org/10.3389/fninf.2019.00072Full Text Link to Item
-
Blocker, S. J., Mowery, Y. M., Holbrook, M. D., Qi, Y., Kirsch, D. G., Johnson, G. A., & Badea, C. T. (2019). Bridging the translational gap: Implementation of multimodal small animal imaging strategies for tumor burden assessment in a co-clinical trial. Plos One, 14(4), e0207555. https://doi.org/10.1371/journal.pone.0207555Full Text Open Access Copy Link to Item
-
Wang, N., Cofer, G., Anderson, R. J., Qi, Y., Liu, C., & Johnson, G. A. (2018). Accelerating quantitative susceptibility imaging acquisition using compressed sensing. Phys Med Biol, 63(24), 245002. https://doi.org/10.1088/1361-6560/aaf15dFull Text Link to Item
-
Wang, N., Anderson, R. J., Badea, A., Cofer, G., Dibb, R., Qi, Y., & Johnson, G. A. (2018). Whole mouse brain structural connectomics using magnetic resonance histology. Brain Struct Funct, 223(9), 4323–4335. https://doi.org/10.1007/s00429-018-1750-xFull Text Link to Item
-
Nouls, J. C., Badea, A., Anderson, R. B. J., Cofer, G. P., & Allan Johnson, G. (2018). Diffusion tensor imaging using multiple coils for mouse brain connectomics. Nmr Biomed, 31(6), e3921. https://doi.org/10.1002/nbm.3921Full Text Link to Item
-
Calabrese, E., Adil, S. M., Cofer, G., Perone, C. S., Cohen-Adad, J., Lad, S. P., & Johnson, G. A. (2018). Postmortem diffusion MRI of the entire human spinal cord at microscopic resolution. Neuroimage Clin, 18, 963–971. https://doi.org/10.1016/j.nicl.2018.03.029Full Text Link to Item
-
Wei, H., Gibbs, E., Zhao, P., Wang, N., Cofer, G. P., Zhang, Y., … Liu, C. (2017). Susceptibility tensor imaging and tractography of collagen fibrils in the articular cartilage. Magn Reson Med, 78(5), 1683–1690. https://doi.org/10.1002/mrm.26882Full Text Link to Item
-
Vetreno, R. P., Yaxley, R., Paniagua, B., Johnson, G. A., & Crews, F. T. (2017). Adult rat cortical thickness changes across age and following adolescent intermittent ethanol treatment. Addict Biol, 22(3), 712–723. https://doi.org/10.1111/adb.12364Full Text Link to Item
-
Anderson, R. J., Cook, J. J., Delpratt, N. A., Nouls, J. C., Gu, B., McNamara, J. O., … Badea, A. (2017). An HPC Pipeline with Validation Framework for Small Animal Multivariate Brain Analysis (SAMBA). Corr, abs/1709.10483.
-
Xie, L., Bennett, K. M., Liu, C., Johnson, G. A., Zhang, J. L., & Lee, V. S. (2016). MRI tools for assessment of microstructure and nephron function of the kidney. Am J Physiol Renal Physiol, 311(6), F1109–F1124. https://doi.org/10.1152/ajprenal.00134.2016Full Text Open Access Copy Link to Item
-
Wei, H., Xie, L., Dibb, R., Li, W., Decker, K., Zhang, Y., … Liu, C. (2016). Imaging whole-brain cytoarchitecture of mouse with MRI-based quantitative susceptibility mapping. Neuroimage, 137, 107–115. https://doi.org/10.1016/j.neuroimage.2016.05.033Full Text Link to Item
-
Xie, L., Layton, A. T., Wang, N., Larson, P. E. Z., Zhang, J. L., Lee, V. S., … Johnson, G. A. (2016). Dynamic contrast-enhanced quantitative susceptibility mapping with ultrashort echo time MRI for evaluating renal function. Am J Physiol Renal Physiol, 310(2), F174–F182. https://doi.org/10.1152/ajprenal.00351.2015Full Text Link to Item
-
Subashi, E., Cordero, F. J., Halvorson, K. G., Qi, Y., Nouls, J. C., Becher, O. J., & Johnson, G. A. (2016). Tumor location, but not H3.3K27M, significantly influences the blood-brain-barrier permeability in a genetic mouse model of pediatric high-grade glioma. J Neurooncol, 126(2), 243–251. https://doi.org/10.1007/s11060-015-1969-9Full Text Link to Item
-
Calabrese, E., Badea, A., Cofer, G., Qi, Y., & Johnson, G. A. (2015). A Diffusion MRI Tractography Connectome of the Mouse Brain and Comparison with Neuronal Tracer Data. Cereb Cortex, 25(11), 4628–4637. https://doi.org/10.1093/cercor/bhv121Full Text Open Access Copy Link to Item
-
Calabrese, E., Badea, A., Coe, C. L., Lubach, G. R., Shi, Y., Styner, M. A., & Johnson, G. A. (2015). A diffusion tensor MRI atlas of the postmortem rhesus macaque brain. Neuroimage, 117, 408–416. https://doi.org/10.1016/j.neuroimage.2015.05.072Full Text Link to Item
-
Calabrese, E., Hickey, P., Hulette, C., Zhang, J., Parente, B., Lad, S. P., & Johnson, G. A. (2015). Postmortem diffusion MRI of the human brainstem and thalamus for deep brain stimulator electrode localization. Hum Brain Mapp, 36(8), 3167–3178. https://doi.org/10.1002/hbm.22836Full Text Link to Item
-
Johnson, G. A. (2015). Magnetic resonance histology. J Magn Reson Imaging, 42(1), 1–2. https://doi.org/10.1002/jmri.24774Full Text Link to Item
-
Subashi, E., Qi, Y., & Johnson, G. A. (2015). Dynamic contrast-enhanced MR microscopy identifies regions of therapeutic response in a preclinical model of colorectal adenocarcinoma. Med Phys, 42(5), 2482–2488. https://doi.org/10.1118/1.4917525Full Text Link to Item
-
Xie, L., Qi, Y., Subashi, E., Liao, G., Miller-DeGraff, L., Jetten, A. M., & Johnson, G. A. (2015). 4D MRI of polycystic kidneys from rapamycin-treated Glis3-deficient mice. Nmr Biomed, 28(5), 546–554. https://doi.org/10.1002/nbm.3281Full Text Link to Item
-
Xie, L., Dibb, R., Cofer, G. P., Li, W., Nicholls, P. J., Johnson, G. A., & Liu, C. (2015). Susceptibility tensor imaging of the kidney and its microstructural underpinnings. Magn Reson Med, 73(3), 1270–1281. https://doi.org/10.1002/mrm.25219Full Text Link to Item
-
Papp, E. A., Leergaard, T. B., Calabrese, E., Johnson, G. A., & Bjaalie, J. G. (2015). Addendum to “Waxholm Space atlas of the Sprague Dawley rat brain” [NeuroImage 97 (2014) 374-386]. Neuroimage, 105, 561–562. https://doi.org/10.1016/j.neuroimage.2014.10.017Full Text Link to Item
-
Borg, J. S., Vu, M.-A., Badea, C., Badea, A., Johnson, G. A., & Dzirasa, K. (2015). Localization of Metal Electrodes in the Intact Rat Brain Using Registration of 3D Microcomputed Tomography Images to a Magnetic Resonance Histology Atlas. Eneuro, 2(4). https://doi.org/10.1523/ENEURO.0017-15.2015Full Text Open Access Copy Link to Item
-
Cao, W., Li, W., Han, H., O’Leary-Moore, S. K., Sulik, K. K., Allan Johnson, G., & Liu, C. (2014). Prenatal alcohol exposure reduces magnetic susceptibility contrast and anisotropy in the white matter of mouse brains. Neuroimage, 102 Pt 2(0 2), 748–755. https://doi.org/10.1016/j.neuroimage.2014.08.035Full Text Link to Item
-
Calabrese, E., Badea, A., Coe, C. L., Lubach, G. R., Styner, M. A., & Johnson, G. A. (2014). Investigating the tradeoffs between spatial resolution and diffusion sampling for brain mapping with diffusion tractography: time well spent? Hum Brain Mapp, 35(11), 5667–5685. https://doi.org/10.1002/hbm.22578Full Text Link to Item
-
Angeli, S., Befera, N., Peyrat, J.-M., Calabrese, E., Johnson, G. A., & Constantinides, C. (2014). A high-resolution cardiovascular magnetic resonance diffusion tensor map from ex-vivo C57BL/6 murine hearts. J Cardiovasc Magn Reson, 16(1), 77. https://doi.org/10.1186/s12968-014-0077-xFull Text Link to Item
-
Xie, L., Subashi, E., Qi, Y., Knepper, M. A., & Johnson, G. A. (2014). Four-dimensional MRI of renal function in the developing mouse. Nmr Biomed, 27(9), 1094–1102. https://doi.org/10.1002/nbm.3162Full Text Link to Item
-
Papp, E. A., Leergaard, T. B., Calabrese, E., Johnson, G. A., & Bjaalie, J. G. (2014). Waxholm Space atlas of the Sprague Dawley rat brain. Neuroimage, 97, 374–386. https://doi.org/10.1016/j.neuroimage.2014.04.001Full Text Link to Item
-
Calabrese, E., Du, F., Garman, R. H., Johnson, G. A., Riccio, C., Tong, L. C., & Long, J. B. (2014). Diffusion tensor imaging reveals white matter injury in a rat model of repetitive blast-induced traumatic brain injury. J Neurotrauma, 31(10), 938–950. https://doi.org/10.1089/neu.2013.3144Full Text Link to Item
-
Johnson, G. A., Calabrese, E., Little, P. B., Hedlund, L., Qi, Y., & Badea, A. (2014). Quantitative mapping of trimethyltin injury in the rat brain using magnetic resonance histology. Neurotoxicology, 42, 12–23. https://doi.org/10.1016/j.neuro.2014.02.009Full Text Open Access Copy Link to Item
-
Befera, N. T., Badea, C. T., & Johnson, G. A. (2014). Comparison of 4D-microSPECT and microCT for murine cardiac function. Mol Imaging Biol, 16(2), 235–245. https://doi.org/10.1007/s11307-013-0686-zFull Text Link to Item
-
Subashi, E., Choudhury, K. R., & Johnson, G. A. (2014). An analysis of the uncertainty and bias in DCE-MRI measurements using the spoiled gradient-recalled echo pulse sequence. Med Phys, 41(3), 032301. https://doi.org/10.1118/1.4865790Full Text Link to Item
-
Argyridis, I., Li, W., Johnson, G. A., & Liu, C. (2014). Quantitative magnetic susceptibility of the developing mouse brain reveals microstructural changes in the white matter. Neuroimage, 88, 134–142. https://doi.org/10.1016/j.neuroimage.2013.11.026Full Text Link to Item
-
Gyengesi, E., Calabrese, E., Sherrier, M. C., Johnson, G. A., Paxinos, G., & Watson, C. (2014). Semi-automated 3D segmentation of major tracts in the rat brain: comparing DTI with standard histological methods. Brain Struct Funct, 219(2), 539–550. https://doi.org/10.1007/s00429-013-0516-8Full Text Link to Item
-
Lee, C.-L., Min, H., Befera, N., Clark, D., Qi, Y., Das, S., … Kirsch, D. G. (2014). Assessing cardiac injury in mice with dual energy-microCT, 4D-microCT, and microSPECT imaging after partial heart irradiation. Int J Radiat Oncol Biol Phys, 88(3), 686–693. https://doi.org/10.1016/j.ijrobp.2013.11.238Full Text Open Access Copy Link to Item
-
Cutlip, R. G., Hollander, M. S., Johnson, G. A., Johnson, B. W., Friend, S. A., & Baker, B. A. (2014). Magnetic resonance imaging of graded skeletal muscle injury in live rats. Environ Health Insights, 8(Suppl 1), 31–39. https://doi.org/10.4137/EHI.S15255Full Text Open Access Copy Link to Item
-
Ashton, J. R., Befera, N., Clark, D., Qi, Y., Mao, L., Rockman, H. A., … Badea, C. T. (2014). Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent. Contrast Media Mol Imaging, 9(2), 161–168. https://doi.org/10.1002/cmmi.1557Full Text Link to Item
-
Lipinski, R. J., Holloway, H. T., O’Leary-Moore, S. K., Ament, J. J., Pecevich, S. J., Cofer, G. P., … Sulik, K. K. (2014). Characterization of subtle brain abnormalities in a mouse model of Hedgehog pathway antagonist-induced cleft lip and palate. Plos One, 9(7), e102603. https://doi.org/10.1371/journal.pone.0102603Full Text Open Access Copy Link to Item
-
Xie, L., Sparks, M. A., Li, W., Qi, Y., Liu, C., Coffman, T. M., & Johnson, G. A. (2013). Quantitative susceptibility mapping of kidney inflammation and fibrosis in type 1 angiotensin receptor-deficient mice. Nmr Biomed, 26(12), 1853–1863. https://doi.org/10.1002/nbm.3039Full Text Link to Item
-
Calabrese, E., & Johnson, G. A. (2013). Diffusion tensor magnetic resonance histology reveals microstructural changes in the developing rat brain. Neuroimage, 79, 329–339. https://doi.org/10.1016/j.neuroimage.2013.04.101Full Text Link to Item
-
Clark, D., Badea, A., Johnson, G. A., & Badea, C. T. (2013). Constructing a 4D murine cardiac micro-CT atlas for automated segmentation and phenotyping applications. Progress in Biomedical Optics and Imaging Proceedings of Spie, 8669. https://doi.org/10.1117/12.2007043Full Text
-
Antonsen, B. T., Jiang, Y., Veraart, J., Qu, H., Nguyen, H. P., Sijbers, J., … Leergaard, T. B. (2013). Altered diffusion tensor imaging measurements in aged transgenic Huntington disease rats. Brain Struct Funct, 218(3), 767–778. https://doi.org/10.1007/s00429-012-0427-0Full Text Open Access Copy Link to Item
-
Calabrese, E., Badea, A., Watson, C., & Johnson, G. A. (2013). A quantitative magnetic resonance histology atlas of postnatal rat brain development with regional estimates of growth and variability. Neuroimage, 71, 196–206. https://doi.org/10.1016/j.neuroimage.2013.01.017Full Text Link to Item
-
Pandit, P., Johnston, S. M., Qi, Y., Story, J., Nelson, R., & Johnson, G. A. (2013). The utility of micro-CT and MRI in the assessment of longitudinal growth of liver metastases in a preclinical model of colon carcinoma. Acad Radiol, 20(4), 430–439. https://doi.org/10.1016/j.acra.2012.09.030Full Text Link to Item
-
Moding, E. J., Clark, D. P., Qi, Y., Li, Y., Ma, Y., Ghaghada, K., … Badea, C. T. (2013). Dual-energy micro-computed tomography imaging of radiation-induced vascular changes in primary mouse sarcomas. Int J Radiat Oncol Biol Phys, 85(5), 1353–1359. https://doi.org/10.1016/j.ijrobp.2012.09.027Full Text Link to Item
-
Bhavane, R., Badea, C., Ghaghada, K. B., Clark, D., Vela, D., Moturu, A., … Willerson, J. T. (2013). Dual-energy computed tomography imaging of atherosclerotic plaques in a mouse model using a liposomal-iodine nanoparticle contrast agent. Circ Cardiovasc Imaging, 6(2), 285–294. https://doi.org/10.1161/CIRCIMAGING.112.000119Full Text Link to Item
-
Calabrese, E., Johnson, G. A., & Watson, C. (2013). An ontology-based segmentation scheme for tracking postnatal changes in the developing rodent brain with MRI. Neuroimage, 67, 375–384. https://doi.org/10.1016/j.neuroimage.2012.11.037Full Text Link to Item
-
Subashi, E., Moding, E. J., Cofer, G. P., MacFall, J. R., Kirsch, D. G., Qi, Y., & Johnson, G. A. (2013). A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models. Med Phys, 40(2), 022304. https://doi.org/10.1118/1.4774050Full Text Link to Item
-
Antonsen, B. T., Jiang, Y., Veraart, J., Qu, H., Nguyen, H. P., Sijbers, J., … Leergaard, T. B. (2013). Altered diffusion tensor imaging measurements in aged transgenic Huntington disease rats. Brain Structure and Function, 218(3), 767–778. https://doi.org/10.1007/s00429-012-0427-0Full Text
-
Badea, A., & Johnson, G. A. (2013). Magnetic resonance microscopy. Stud Health Technol Inform, 185, 153–184.Link to Item
-
Badea, C. T., Hedlund, L. W., & Johnson, G. A. (2013). A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT. J Med Eng, 2013, 581617. https://doi.org/10.1155/2013/581617Full Text Open Access Copy Link to Item
-
Johnson, G. A., Badea, A., Calabrese, E., Liu, C., & Xie, L. (2013). Magnetic resonance histology: cool images- but who cares? Toxicology Letters, 221, S50–S50. https://doi.org/10.1016/j.toxlet.2013.06.183Full Text Link to Item
-
O’Leary-Moore, S. K., Budin, F., Paniagua, B., Oguz, I., Johnson, G. A., & Sulik, K. K. (2013). HIGH-RESOLUTION NEUROIMAGING REVEALS A RANGE OF CORPUS CALLOSUM INSULT INDUCED BY ETHANOL ON GESTATIONAL DAY 7 INMICE. Alcoholism Clinical and Experimental Research, 37, 167A-167A.Link to Item
-
Parnell, S. E., Holloway, H. T., O’Leary-Moore, S. K., Dehart, D. B., Paniaqua, B., Oguz, I., … Sulik, K. K. (2013). Magnetic resonance microscopy-based analyses of the neuroanatomical effects of gestational day 9 ethanol exposure in mice. Neurotoxicol Teratol, 39, 77–83. https://doi.org/10.1016/j.ntt.2013.07.009Full Text Link to Item
-
Badea, A., Gewalt, S., Avants, B. B., Cook, J. J., & Johnson, G. A. (2012). Quantitative mouse brain phenotyping based on single and multispectral MR protocols. Neuroimage, 63(3), 1633–1645. https://doi.org/10.1016/j.neuroimage.2012.07.021Full Text Link to Item
-
Howles, G. P., Qi, Y., Rosenzweig, S. J., Nightingale, K. R., & Johnson, G. A. (2012). Functional neuroimaging using ultrasonic blood-brain barrier disruption and manganese-enhanced MRI. Journal of Visualized Experiments : Jove, (65).
-
Clark, D., Badea, A., Liu, Y., Johnson, G. A., & Badea, C. T. (2012). Registration-based segmentation of murine 4D cardiac micro-CT data using symmetric normalization. Phys Med Biol, 57(19), 6125–6145. https://doi.org/10.1088/0031-9155/57/19/6125Full Text Link to Item
-
Johnson, G. A., Calabrese, E., Badea, A., Paxinos, G., & Watson, C. (2012). A multidimensional magnetic resonance histology atlas of the Wistar rat brain. Neuroimage, 62(3), 1848–1856. https://doi.org/10.1016/j.neuroimage.2012.05.041Full Text Link to Item
-
Johnston, S. M., Johnson, G. A., & Badea, C. T. (2012). Temporal and spectral imaging with micro-CT. Med Phys, 39(8), 4943–4958. https://doi.org/10.1118/1.4736809Full Text Link to Item
-
Howles, G. P., Qi, Y., Rosenzweig, S. J., Nightingale, K. R., & Johnson, G. A. (2012). Functional neuroimaging using ultrasonic blood-brain barrier disruption and manganese-enhanced MRI. J Vis Exp, (65), e4055. https://doi.org/10.3791/4055Full Text Link to Item
-
Xie, L., Cianciolo, R. E., Hulette, B., Lee, H. W., Qi, Y., Cofer, G., & Johnson, G. A. (2012). Magnetic resonance histology of age-related nephropathy in the Sprague Dawley rat. Toxicol Pathol, 40(5), 764–778. https://doi.org/10.1177/0192623312441408Full Text Link to Item
-
Perperidis, D., Bucholz, E., Johnson, G. A., & Constantinides, C. (2012). Morphological studies of the murine heart based on probabilistic and statistical atlases. Comput Med Imaging Graph, 36(2), 119–129. https://doi.org/10.1016/j.compmedimag.2011.07.001Full Text Link to Item
-
Liu, C., Li, W., Wu, B., Jiang, Y., & Johnson, G. A. (2012). 3D fiber tractography with susceptibility tensor imaging. Neuroimage, 59(2), 1290–1298. https://doi.org/10.1016/j.neuroimage.2011.07.096Full Text Link to Item
-
Guo, X., Johnston, S. M., Qi, Y., Johnson, G. A., & Badea, C. T. (2012). 4D micro-CT using fast prospective gating. Phys Med Biol, 57(1), 257–271. https://doi.org/10.1088/0031-9155/57/1/257Full Text Link to Item
-
Badea, A., & Johnson, G. A. (2012). Magnetic resonance microscopy. Anal Cell Pathol (Amst), 35(4), 205–227. https://doi.org/10.3233/ACP-2011-0050Full Text Open Access Copy Link to Item
-
Lipinski, R. J., Hammond, P., O’Leary-Moore, S. K., Ament, J. J., Pecevich, S. J., Jiang, Y., … Sulik, K. K. (2012). Ethanol-induced face-brain dysmorphology patterns are correlative and exposure-stage dependent. Plos One, 7(8), e43067. https://doi.org/10.1371/journal.pone.0043067Full Text Link to Item
-
Macfall, J. S., & Johnson, G. A. (2012). Plants, seeds, roots, and soils as applications of magnetic resonance microscopy. Emagres, 1(1), 147–154. https://doi.org/10.1002/9780470034590.emrstm0396Full Text
-
Badea, C. T., Athreya, K. K., Espinosa, G., Clark, D., Ghafoori, A. P., Li, Y., … Ghaghada, K. B. (2012). Computed tomography imaging of primary lung cancer in mice using a liposomal-iodinated contrast agent. Plos One, 7(4), e34496. https://doi.org/10.1371/journal.pone.0034496Full Text Open Access Copy Link to Item
-
O’Leary-Moore, S. K., Johnson, G. A., Calabrese, E., Budin, F., Oguz, I., Styner, M. A., … Sulik, K. K. (2012). DIFFUSION TENSOR IMAGING (DTI)-BASED ANALYSIS OF FIBER TRACT ABNORMALITIES IN A MOUSE MODEL OF PRENATAL ALCOHOL EXPOSURE. Alcoholism Clinical and Experimental Research, 36, 312A-312A.Link to Item
-
Veraart, J., Leergaard, T. B., Antonsen, B. T., Van Hecke, W., Blockx, I., Jeurissen, B., … Sijbers, J. (2011). Population-averaged diffusion tensor imaging atlas of the Sprague Dawley rat brain. Neuroimage, 58(4), 975–983. https://doi.org/10.1016/j.neuroimage.2011.06.063Full Text Link to Item
-
Zhang, X., Badea, C., Hood, G., Wetzel, A., Qi, Y., Stiles, J., & Johnson, G. A. (2011). High-resolution reconstruction of fluorescent inclusions in mouse thorax using anatomically guided sampling and parallel Monte Carlo computing. Biomed Opt Express, 2(9), 2449–2460. https://doi.org/10.1364/BOE.2.002449Full Text Open Access Copy Link to Item
-
Badea, C. T., Johnston, S. M., Qi, Y., & Johnson, G. A. (2011). 4D micro-CT for cardiac and perfusion applications with view under sampling. Phys Med Biol, 56(11), 3351–3369. https://doi.org/10.1088/0031-9155/56/11/011Full Text Link to Item
-
Jiang, Y., & Johnson, G. A. (2011). Microscopic diffusion tensor atlas of the mouse brain. Neuroimage, 56(3), 1235–1243. https://doi.org/10.1016/j.neuroimage.2011.03.031Full Text Link to Item
-
Liu, C., Li, W., Johnson, G. A., & Wu, B. (2011). High-field (9.4 T) MRI of brain dysmyelination by quantitative mapping of magnetic susceptibility. Neuroimage, 56(3), 930–938. https://doi.org/10.1016/j.neuroimage.2011.02.024Full Text Link to Item
-
Rajagopal, S., Kovacs, J., Badea, C., Johnson, G. A., Rockman, H. A., Piantadosi, C. A., & Lefkowitz, R. J. (2011). BETA-ARRESTINS REGULATE SIGNALING BY BONE MORPHOGENETIC PROTEIN TYPE II RECEPTOR IN PULMONARY ARTERIAL HYPERTENSION. Journal of the American College of Cardiology, 57(14), E2046–E2046. https://doi.org/10.1016/s0735-1097(11)62046-9Full Text
-
Bowden, D. M., Johnson, G. A., Zaborsky, L., Green, W. D. K., Moore, E., Badea, A., … Bookstein, F. L. (2011). A symmetrical Waxholm canonical mouse brain for NeuroMaps. J Neurosci Methods, 195(2), 170–175. https://doi.org/10.1016/j.jneumeth.2010.11.028Full Text Link to Item
-
Hawrylycz, M., Baldock, R. A., Burger, A., Hashikawa, T., Johnson, G. A., Martone, M., … Boline, J. (2011). Digital atlasing and standardization in the mouse brain. Plos Comput Biol, 7(2), e1001065. https://doi.org/10.1371/journal.pcbi.1001065Full Text Link to Item
-
Pandit, P., Qi, Y., King, K. F., & Johnson, G. A. (2011). Reduction of artifacts in T2 -weighted PROPELLER in high-field preclinical imaging. Magn Reson Med, 65(2), 538–543. https://doi.org/10.1002/mrm.22624Full Text Link to Item
-
Bolon, B., Garman, R. H., Gundersen, H. J. G., Allan Johnson, G., Kaufmann, W., Krinke, G., … Jensen, K. (2011). Continuing education course #3: current practices and future trends in neuropathology assessment for developmental neurotoxicity testing. Toxicol Pathol, 39(1), 289–293. https://doi.org/10.1177/0192623310386247Full Text Link to Item
-
Johnson, G. A., Badea, A., & Jiang, Y. (2011). Quantitative neuromorphometry using magnetic resonance histology. Toxicol Pathol, 39(1), 85–91. https://doi.org/10.1177/0192623310389622Full Text Link to Item
-
Peterson, R. A., Gabrielson, K. L., Allan Johnson, G., Pomper, M. G., Coatney, R. W., & Winkelmann, C. T. (2011). Continuing education course #1: non-invasive imaging as a problem-solving tool and translational biomarker strategy in toxicologic pathology. Toxicol Pathol, 39(1), 267–272. https://doi.org/10.1177/0192623310390392Full Text Link to Item
-
Badea, C. T., Hedlund, L. W., Cook, J., Berridge, B. R., & Johnson, G. A. (2011). Micro-CT imaging assessment of dobutamine-induced cardiac stress in rats. J Pharmacol Toxicol Methods, 63(1), 24–29. https://doi.org/10.1016/j.vascn.2010.04.002Full Text Link to Item
-
Badea, C. T., Hedlund, L. W., Qi, Y., Berridge, B., & Johnson, G. A. (2011). In vivo imaging of rat coronary arteries using bi-plane digital subtraction angiography. J Pharmacol Toxicol Methods, 64(2), 151–157. https://doi.org/10.1016/j.vascn.2011.05.008Full Text Link to Item
-
Ghaghada, K. B., Badea, C. T., Karumbaiah, L., Fettig, N., Bellamkonda, R. V., Johnson, G. A., & Annapragada, A. (2011). Evaluation of tumor microenvironment in an animal model using a nanoparticle contrast agent in computed tomography imaging. Acad Radiol, 18(1), 20–30. https://doi.org/10.1016/j.acra.2010.09.003Full Text Link to Item
-
Lin, M., Qi, Y., Chen, A. F., Badea, C. T., & Johnson, G. A. (2011). Phenylephrine-modulated cardiopulmonary blood flow measured with use of X-ray digital subtraction angiography. J Pharmacol Toxicol Methods, 64(2), 180–186. https://doi.org/10.1016/j.vascn.2011.08.001Full Text Link to Item
-
Johnson, G. A., Badea, A., Brandenburg, J., Cofer, G., Fubara, B., Liu, S., & Nissanov, J. (2010). Waxholm space: an image-based reference for coordinating mouse brain research. Neuroimage, 53(2), 365–372. https://doi.org/10.1016/j.neuroimage.2010.06.067Full Text Link to Item
-
O’Leary-Moore, S. K., Parnell, S. E., Godin, E. A., Dehart, D. B., Ament, J. J., Khan, A. A., … Sulik, K. K. (2010). Magnetic resonance microscopy-based analyses of the brains of normal and ethanol-exposed fetal mice. Birth Defects Res a Clin Mol Teratol, 88(11), 953–964. https://doi.org/10.1002/bdra.20719Full Text Link to Item
-
Brinegar, C., Schmitter, S. S., Mistry, N. N., Johnson, G. A., & Liang, Z.-P. (2010). Improving temporal resolution of pulmonary perfusion imaging in rats using the partially separable functions model. Magn Reson Med, 64(4), 1162–1170. https://doi.org/10.1002/mrm.22500Full Text Link to Item
-
Howles, G. P., Bing, K. F., Qi, Y., Rosenzweig, S. J., Nightingale, K. R., & Johnson, G. A. (2010). Contrast-enhanced in vivo magnetic resonance microscopy of the mouse brain enabled by noninvasive opening of the blood-brain barrier with ultrasound. Magn Reson Med, 64(4), 995–1004. https://doi.org/10.1002/mrm.22411Full Text Link to Item
-
Pandit, P., Qi, Y., Story, J., King, K. F., & Johnson, G. A. (2010). Multishot PROPELLER for high-field preclinical MRI. Magn Reson Med, 64(1), 47–53. https://doi.org/10.1002/mrm.22376Full Text Link to Item
-
Howles, G. P., Qi, Y., & Johnson, G. A. (2010). Ultrasonic disruption of the blood-brain barrier enables in vivo functional mapping of the mouse barrel field cortex with manganese-enhanced MRI. Neuroimage, 50(4), 1464–1471. https://doi.org/10.1016/j.neuroimage.2010.01.050Full Text Link to Item
-
Badea, A., Johnson, G. A., & Jankowsky, J. L. (2010). Remote sites of structural atrophy predict later amyloid formation in a mouse model of Alzheimer's disease. Neuroimage, 50(2), 416–427. https://doi.org/10.1016/j.neuroimage.2009.12.070Full Text Link to Item
-
Jiang, Y., & Johnson, G. A. (2010). Microscopic diffusion tensor imaging of the mouse brain. Neuroimage, 50(2), 465–471. https://doi.org/10.1016/j.neuroimage.2009.12.057Full Text Link to Item
-
Bucholz, E., Ghaghada, K., Qi, Y., Mukundan, S., Rockman, H. A., & Johnson, G. A. (2010). Cardiovascular phenotyping of the mouse heart using a 4D radial acquisition and liposomal Gd-DTPA-BMA. Magn Reson Med, 63(4), 979–987. https://doi.org/10.1002/mrm.22259Full Text Link to Item
-
Mistry, N. N., Qi, Y., Hedlund, L. W., & Johnson, G. A. (2010). Ventilation/perfusion imaging in a rat model of airway obstruction. Magn Reson Med, 63(3), 728–735. https://doi.org/10.1002/mrm.22221Full Text Link to Item
-
Mistry, N. N., Thomas, A., Kaushik, S. S., Johnson, G. A., & Driehuys, B. (2010). Quantitative analysis of hyperpolarized 3He ventilation changes in mice challenged with methacholine. Magn Reson Med, 63(3), 658–666. https://doi.org/10.1002/mrm.22311Full Text Link to Item
-
Godin, E. A., O’Leary-Moore, S. K., Khan, A. A., Parnell, S. E., Ament, J. J., Dehart, D. B., … Sulik, K. K. (2010). Magnetic resonance microscopy defines ethanol-induced brain abnormalities in prenatal mice: effects of acute insult on gestational day 7. Alcohol Clin Exp Res, 34(1), 98–111. https://doi.org/10.1111/j.1530-0277.2009.01071.xFull Text Link to Item
-
Badea, C. T., Johnston, S. M., Subashi, E., Qi, Y., Hedlund, L. W., & Johnson, G. A. (2010). Lung perfusion imaging in small animals using 4D micro-CT at heartbeat temporal resolution. Med Phys, 37(1), 54–62. https://doi.org/10.1118/1.3264619Full Text Link to Item
-
Petiet, A., & Johnson, G. A. (2010). Active staining of mouse embryos for magnetic resonance microscopy. Methods Mol Biol, 611, 141–149. https://doi.org/10.1007/978-1-60327-345-9_11Full Text Link to Item
-
MacKenzie-Graham, A., Tiwari-Woodruff, S. K., Sharma, G., Aguilar, C., Vo, K. T., Strickland, L. V., … Voskuhl, R. R. (2009). Purkinje cell loss in experimental autoimmune encephalomyelitis. Neuroimage, 48(4), 637–651. https://doi.org/10.1016/j.neuroimage.2009.06.073Full Text Link to Item
-
Howles, G. P., Ghaghada, K. B., Qi, Y., Mukundan, S., & Johnson, G. A. (2009). High-resolution magnetic resonance angiography in the mouse using a nanoparticle blood-pool contrast agent. Magn Reson Med, 62(6), 1447–1456. https://doi.org/10.1002/mrm.22154Full Text Link to Item
-
Lin, M., Marshall, C. T., Qi, Y., Johnston, S. M., Badea, C. T., Piantadosi, C. A., & Johnson, G. A. (2009). Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography. Med Phys, 36(11), 5347–5358. https://doi.org/10.1118/1.3231823Full Text Link to Item
-
Badea, A., Johnson, G. A., & Williams, R. W. (2009). Genetic dissection of the mouse CNS using magnetic resonance microscopy. Curr Opin Neurol, 22(4), 379–386. https://doi.org/10.1097/WCO.0b013e32832d9b86Full Text Link to Item
-
Howles, G. P., Nouls, J. C., Qi, Y., & Johnson, G. A. (2009). Rapid production of specialized animal handling devices using computer-aided design and solid freeform fabrication. J Magn Reson Imaging, 30(2), 466–471. https://doi.org/10.1002/jmri.21821Full Text Link to Item
-
Parnell, S. E., O’Leary-Moore, S. K., Godin, E. A., Dehart, D. B., Johnson, B. W., Allan Johnson, G., … Sulik, K. K. (2009). Magnetic resonance microscopy defines ethanol-induced brain abnormalities in prenatal mice: effects of acute insult on gestational day 8. Alcohol Clin Exp Res, 33(6), 1001–1011. https://doi.org/10.1111/j.1530-0277.2009.00921.xFull Text Link to Item
-
Badea, A., Johnson, G. A., & Williams, R. W. (2009). Genetic dissection of the mouse brain using high-field magnetic resonance microscopy. Neuroimage, 45(4), 1067–1079. https://doi.org/10.1016/j.neuroimage.2009.01.021Full Text Link to Item
-
Song, J., Liu, Y., Gewalt, S. L., Cofer, G., Johnson, G. A., & Liu, Q. H. (2009). Least-square NUFFT methods applied to 2-D and 3-D radially encoded MR image reconstruction. Ieee Trans Biomed Eng, 56(4), 1134–1142. https://doi.org/10.1109/TBME.2009.2012721Full Text Link to Item
-
Zhang, X., Badea, C. T., & Johnson, G. A. (2009). Three-dimensional reconstruction in free-space whole-body fluorescence tomography of mice using optically reconstructed surface and atlas anatomy. J Biomed Opt, 14(6), 064010. https://doi.org/10.1117/1.3258836Full Text Link to Item
-
Badea, C. T., Drangova, M., Holdsworth, D. W., & Johnson, G. A. (2008). In vivo small-animal imaging using micro-CT and digital subtraction angiography. Phys Med Biol, 53(19), R319–R350. https://doi.org/10.1088/0031-9155/53/19/R01Full Text Link to Item
-
Johnson, K., Badea, C., Hedlund, L., & Johnson, G. A. (2008). Imaging techniques for small animal imaging models of pulmonary disease: Micro-CT (Toxicologic Pathology (2007) 35, 5 (9-64)). Toxicologic Pathology, 36(6), 895. https://doi.org/10.1177/0192623308323921Full Text
-
Petiet, A. E., Kaufman, M. H., Goddeeris, M. M., Brandenburg, J., Elmore, S. A., & Johnson, G. A. (2008). High-resolution magnetic resonance histology of the embryonic and neonatal mouse: a 4D atlas and morphologic database. Proc Natl Acad Sci U S A, 105(34), 12331–12336. https://doi.org/10.1073/pnas.0805747105Full Text Link to Item
-
De Lin, M., Toncheva, G., Nguyen, G., Kim, S., Anderson-Evans, C., Johnson, G. A., & Yoshizumi, T. T. (2008). Application of MOSFET detectors for dosimetry in small animal radiography using short exposure times. Radiat Res, 170(2), 260–263. https://doi.org/10.1667/RR1328.1Full Text Link to Item
-
Shofer, S., Badea, C., Qi, Y., Potts, E., Foster, W. M., & Johnson, G. A. (2008). A micro-CT analysis of murine lung recruitment in bleomycin-induced lung injury. J Appl Physiol (1985), 105(2), 669–677. https://doi.org/10.1152/japplphysiol.00980.2007Full Text Link to Item
-
Bucholz, E., Ghaghada, K., Qi, Y., Mukundan, S., & Johnson, G. A. (2008). Four-dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent. Magn Reson Med, 60(1), 111–118. https://doi.org/10.1002/mrm.21618Full Text Link to Item
-
Goddeeris, M. M., Rho, S., Petiet, A., Davenport, C. L., Johnson, G. A., Meyers, E. N., & Klingensmith, J. (2008). Intracardiac septation requires hedgehog-dependent cellular contributions from outside the heart. Development, 135(10), 1887–1895. https://doi.org/10.1242/dev.016147Full Text Link to Item
-
Johnston, S. M., Johnson, G. A., & Badea, C. T. (2008). Geometric calibration for a dual tube/detector micro-CT system. Med Phys, 35(5), 1820–1829. https://doi.org/10.1118/1.2900000Full Text Link to Item
-
Badea, C. T., Wetzel, A. W., Mistry, N., Pomerantz, S., Nave, D., & Johnson, G. A. (2008). Left ventricle volume measurements in cardiac micro-CT: the impact of radiation dose and contrast agent. Comput Med Imaging Graph, 32(3), 239–250. https://doi.org/10.1016/j.compmedimag.2007.12.004Full Text Link to Item
-
Nouls, J. C., Izenson, M. G., Greeley, H. P., & Johnson, G. A. (2008). Design of a superconducting volume coil for magnetic resonance microscopy of the mouse brain. J Magn Reson, 191(2), 231–238. https://doi.org/10.1016/j.jmr.2007.12.018Full Text Link to Item
-
Bucholz, E. K., Song, J., Johnson, G. A., & Hancu, I. (2008). Multispectral imaging with three-dimensional rosette trajectories. Magn Reson Med, 59(3), 581–589. https://doi.org/10.1002/mrm.21551Full Text Link to Item
-
de Lin, M., Ning, L., Badea, C. T., Mistry, N. N., Qi, Y., & Johnson, G. A. (2008). A high-precision contrast injector for small animal x-ray digital subtraction angiography. Ieee Trans Biomed Eng, 55(3), 1082–1091. https://doi.org/10.1109/TBME.2007.909541Full Text Link to Item
-
Lu, H., Pollack, E., Young, R., Babb, J. S., Johnson, G., Zagzag, D., … Law, M. (2008). Predicting grade of cerebral glioma using vascular-space occupancy MR imaging. Ajnr Am J Neuroradiol, 29(2), 373–378. https://doi.org/10.3174/ajnr.A0794Full Text Link to Item
-
Mistry, N. N., Pollaro, J., Song, J., De Lin, M., & Johnson, G. A. (2008). Pulmonary perfusion imaging in the rodent lung using dynamic contrast-enhanced MRI. Magn Reson Med, 59(2), 289–297. https://doi.org/10.1002/mrm.21353Full Text Link to Item
-
Sharief, A. A., Badea, A., Dale, A. M., & Johnson, G. A. (2008). Automated segmentation of the actively stained mouse brain using multi-spectral MR microscopy. Neuroimage, 39(1), 136–145. https://doi.org/10.1016/j.neuroimage.2007.08.028Full Text Link to Item
-
Oldham, M., Sakhalkar, H., Oliver, T., Allan Johnson, G., & Dewhirst, M. (2008). Optical clearing of unsectioned specimens for three-dimensional imaging via optical transmission and emission tomography. J Biomed Opt, 13(2), 021113. https://doi.org/10.1117/1.2907968Full Text Link to Item
-
Driehuys, B., Walker, J., Pollaro, J., Cofer, G. P., Mistry, N., Schwartz, D., & Johnson, G. A. (2007). 3He MRI in mouse models of asthma. Magn Reson Med, 58(5), 893–900. https://doi.org/10.1002/mrm.21306Full Text Link to Item
-
Song, J., Liu, Q. H., Johnson, G. A., & Badea, C. T. (2007). Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT. Med Phys, 34(11), 4476–4483. https://doi.org/10.1118/1.2795830Full Text Link to Item
-
Badea, A., Ali-Sharief, A. A., & Johnson, G. A. (2007). Morphometric analysis of the C57BL/6J mouse brain. Neuroimage, 37(3), 683–693. https://doi.org/10.1016/j.neuroimage.2007.05.046Full Text Link to Item
-
Johnson, G. A., Ali-Sharief, A., Badea, A., Brandenburg, J., Cofer, G., Fubara, B., … Upchurch, L. (2007). High-throughput morphologic phenotyping of the mouse brain with magnetic resonance histology. Neuroimage, 37(1), 82–89. https://doi.org/10.1016/j.neuroimage.2007.05.013Full Text Link to Item
-
Nahrendorf, M., Badea, C., Hedlund, L. W., Figueiredo, J.-L., Sosnovik, D. E., Johnson, G. A., & Weissleder, R. (2007). High-resolution imaging of murine myocardial infarction with delayed-enhancement cine micro-CT. Am J Physiol Heart Circ Physiol, 292(6), H3172–H3178. https://doi.org/10.1152/ajpheart.01307.2006Full Text Link to Item
-
Petiet, A., Hedlund, L., & Johnson, G. A. (2007). Staining methods for magnetic resonance microscopy of the rat fetus. J Magn Reson Imaging, 25(6), 1192–1198. https://doi.org/10.1002/jmri.20932Full Text Link to Item
-
Badea, C. T., Hedlund, L. W., De Lin, M., Mackel, J. S. B., Samei, E., & Johnson, G. A. (2007). Tomographic digital subtraction angiography for lung perfusion estimation in rodents. Med Phys, 34(5), 1546–1555. https://doi.org/10.1118/1.2717384Full Text Link to Item
-
Rice, H. E., Hsu, E. W., Sheng, H., Evenson, D. A., Freemerman, A. J., Safford, K. M., … Johnson, G. A. (2007). Superparamagnetic iron oxide labeling and transplantation of adipose-derived stem cells in middle cerebral artery occlusion-injured mice. Ajr Am J Roentgenol, 188(4), 1101–1108. https://doi.org/10.2214/AJR.06.0663Full Text Link to Item
-
Badea, A., Nicholls, P. J., Johnson, G. A., & Wetsel, W. C. (2007). Neuroanatomical phenotypes in the reeler mouse. Neuroimage, 34(4), 1363–1374. https://doi.org/10.1016/j.neuroimage.2006.09.053Full Text Link to Item
-
Badea, C. T., Hedlund, L. W., Mackel, J. F. B., Mao, L., Rockman, H. A., & Johnson, G. A. (2007). Cardiac micro-computed tomography for morphological and functional phenotyping of muscle LIM protein null mice. Mol Imaging, 6(4), 261–268.Link to Item
-
Shofer, S., Badea, C., Auerbach, S., Schwartz, D. A., & Johnson, G. A. (2007). A micro-computed tomography-based method for the measurement of pulmonary compliance in healthy and bleomycin-exposed mice. Exp Lung Res, 33(3–4), 169–183. https://doi.org/10.1080/01902140701364458Full Text Link to Item
-
Driehuys, B., Cofer, G. P., Pollaro, J., Mackel, J. B., Hedlund, L. W., & Johnson, G. A. (2006). Imaging alveolar-capillary gas transfer using hyperpolarized 129Xe MRI. Proc Natl Acad Sci U S A, 103(48), 18278–18283. https://doi.org/10.1073/pnas.0608458103Full Text Link to Item
-
De Lin, M., Samei, E., Badea, C. T., Yoshizumi, T. T., & Allan Johnson, G. (2006). Optimized radiographic spectra for small animal digital subtraction angiography. Med Phys, 33(11), 4249–4257. https://doi.org/10.1118/1.2356646Full Text Link to Item
-
Sharief, A. A., & Johnson, G. A. (2006). Enhanced T2 contrast for MR histology of the mouse brain. Magn Reson Med, 56(4), 717–725. https://doi.org/10.1002/mrm.21026Full Text Link to Item
-
Oldham, M., Sakhalkar, H., Oliver, T., Wang, Y. M., Kirpatrick, J., Cao, Y., … Dewhirst, M. (2006). Three-dimensional imaging of xenograft tumors using optical computed and emission tomography. Med Phys, 33(9), 3193–3202. https://doi.org/10.1118/1.2217109Full Text Link to Item
-
Mukundan, S., Ghaghada, K. B., Badea, C. T., Kao, C.-Y., Hedlund, L. W., Provenzale, J. M., … Annapragada, A. (2006). A liposomal nanoscale contrast agent for preclinical CT in mice. Ajr Am J Roentgenol, 186(2), 300–307. https://doi.org/10.2214/AJR.05.0523Full Text Link to Item
-
Jaffe, T. A., Nelson, R. C., Johnson, G. A., Lee, E. R., Yoshizumi, T. T., Lowry, C. R., … Paulson, E. K. (2006). Optimization of multiplanar reformations from isotropic data sets acquired with 16-detector row helical CT scanner. Radiology, 238(1), 292–299. https://doi.org/10.1148/radiol.2381050404Full Text Link to Item
-
Badea, C. T., Bucholz, E., Hedlund, L. W., Rockman, H. A., & Johnson, G. A. (2006). Imaging methods for morphological and functional phenotyping of the rodent heart. Toxicol Pathol, 34(1), 111–117. https://doi.org/10.1080/01926230500404126Full Text Link to Item
-
Badea, C. T., Hedlund, L. W., De Lin, M., Boslego Mackel, J. F., & Johnson, G. A. (2006). Tumor imaging in small animals with a combined micro-CT/micro-DSA system using iodinated conventional and blood pool contrast agents. Contrast Media Mol Imaging, 1(4), 153–164. https://doi.org/10.1002/cmmi.103Full Text Link to Item
-
Ali, A. A., Dale, A. M., Badea, A., & Johnson, G. A. (2005). Automated segmentation of neuroanatomical structures in multispectral MR microscopy of the mouse brain. Neuroimage, 27(2), 425–435. https://doi.org/10.1016/j.neuroimage.2005.04.017Full Text Link to Item
-
Tengowski, M. W., Sutovsky, P., Hedlund, L. W., Guyot, D. J., Burkhardt, J. E., Thompson, W. E., … Johnson, G. A. (2005). Reproductive cytotoxicity is predicted by magnetic resonance microscopy and confirmed by ubiquitin-proteasome immunohistochemistry in a theophylline-induced model of rat testicular and epididymal toxicity. Microsc Microanal, 11(4), 300–312. https://doi.org/10.1017/S143192760505021XFull Text Link to Item
-
Cyr, M., Caron, M. G., Johnson, G. A., & Laakso, A. (2005). Magnetic resonance imaging at microscopic resolution reveals subtle morphological changes in a mouse model of dopaminergic hyperfunction. Neuroimage, 26(1), 83–90. https://doi.org/10.1016/j.neuroimage.2005.01.039Full Text Link to Item
-
Maï, W., Badea, C. T., Wheeler, C. T., Hedlund, L. W., & Johnson, G. A. (2005). Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodents. Magn Reson Med, 53(4), 858–865. https://doi.org/10.1002/mrm.20400Full Text Link to Item
-
Badea, C. T., Fubara, B., Hedlund, L. W., & Johnson, G. A. (2005). 4-D micro-CT of the mouse heart. Mol Imaging, 4(2), 110–116. https://doi.org/10.1162/15353500200504187Full Text Link to Item
-
Chen, B. T., Yordanov, A. T., & Johnson, G. A. (2005). Ventilation-synchronous magnetic resonance microscopy of pulmonary structure and ventilation in mice. Magn Reson Med, 53(1), 69–75. https://doi.org/10.1002/mrm.20307Full Text Link to Item
-
Badea, C., Hedlund, L. W., & Johnson, G. A. (2004). Micro-CT with respiratory and cardiac gating. Med Phys, 31(12), 3324–3329. https://doi.org/10.1118/1.1812604Full Text Link to Item
-
Chen, B. T., & Johnson, G. A. (2004). Dynamic lung morphology of methacholine-induced heterogeneous bronchoconstriction. Magn Reson Med, 52(5), 1080–1086. https://doi.org/10.1002/mrm.20251Full Text Link to Item
-
Morgan, D. L., Little, P. B., Herr, D. W., Moser, V. C., Collins, B., Herbert, R., … Sills, R. C. (2004). Neurotoxicity of carbonyl sulfide in F344 rats following inhalation exposure for up to 12 weeks. Toxicol Appl Pharmacol, 200(2), 131–145. https://doi.org/10.1016/j.taap.2004.04.013Full Text Link to Item
-
Brau, A. C. S., Hedlund, L. W., & Johnson, G. A. (2004). Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction. J Magn Reson Imaging, 20(1), 31–38. https://doi.org/10.1002/jmri.20089Full Text Link to Item
-
Sills, R. C., Morgan, D. L., Maronpot, R. R., & Johnson, G. A. (2004). Contribution of magnetic resonance microscopy in the biologic and mechanistic assessment of carbonyl sulfide neurotoxicity in F344 rats. Toxicology and Applied Pharmacology, 197(3), 151–152.Link to Item
-
Zhang, X., Tengowski, M., Fasulo, L., Botts, S., Suddarth, S. A., & Johnson, G. A. (2004). Measurement of fat/water ratios in rat liver using 3D three-point dixon MRI. Magn Reson Med, 51(4), 697–702. https://doi.org/10.1002/mrm.20005Full Text Link to Item
-
Chen, B. T., Yordanov, A. T., & Johnson, G. A. (2004). Functional pulmonary MR microscopy in mice. Faseb Journal, 18(5), A785–A785.Link to Item
-
Maronpot, R. R., Sills, R. C., & Johnson, G. A. (2004). Applications of magnetic resonance microscopy. Toxicol Pathol, 32 Suppl 2, 42–48. https://doi.org/10.1080/01926230490451707Full Text Link to Item
-
Segars, W. P., Tsui, B. M. W., Frey, E. C., Johnson, G. A., & Berr, S. S. (2004). Development of a 4-D digital mouse phantom for molecular imaging research. Mol Imaging Biol, 6(3), 149–159. https://doi.org/10.1016/j.mibio.2004.03.002Full Text Link to Item
-
Sills, R. C., Morgan, D. L., Herr, D. W., Little, P. B., George, N. M., Ton, T. V., … Johnson, G. A. (2004). Contribution of magnetic resonance microscopy in the 12-week neurotoxicity evaluation of carbonyl sulfide in Fischer 344 rats. Toxicol Pathol, 32(5), 501–510. https://doi.org/10.1080/01926230490493918Full Text Link to Item
-
Yelbuz, T. M., Zhang, X., Choma, M. A., Stadt, H. A., Zdanowicz, M., Johnson, G. A., & Kirby, M. L. (2003). Images in cardiovascular medicine. Approaching cardiac development in three dimensions by magnetic resonance microscopy. Circulation, 108(22), e154–e155. https://doi.org/10.1161/01.CIR.0000102940.17908.CAFull Text Link to Item
-
Yelbuz, T. M., Waldo, K. L., Zhang, X., Zdanowicz, M., Parker, J., Creazzo, T. L., … Kirby, M. L. (2003). Myocardial volume and organization are changed by failure of addition of secondary heart field myocardium to the cardiac outflow tract. Dev Dyn, 228(2), 152–160. https://doi.org/10.1002/dvdy.10364Full Text Link to Item
-
Gupta, A. K., Nelson, R. C., Johnson, G. A., Paulson, E. K., Delong, D. M., & Yoshizumi, T. T. (2003). Optimization of eight-element multi-detector row helical CT technology for evaluation of the abdomen. Radiology, 227(3), 739–745. https://doi.org/10.1148/radiol.2273020591Full Text Link to Item
-
Zhang, X., Yelbuz, T. M., Cofer, G. P., Choma, M. A., Kirby, M. L., & Johnson, G. A. (2003). Improved preparation of chick embryonic samples for magnetic resonance microscopy. Magn Reson Med, 49(6), 1192–1195. https://doi.org/10.1002/mrm.10460Full Text Link to Item
-
Chen, B. T., Brau, A. C. S., & Johnson, G. A. (2003). Measurement of regional lung function in rats using hyperpolarized 3helium dynamic MRI. Magn Reson Med, 49(1), 78–88. https://doi.org/10.1002/mrm.10336Full Text Link to Item
-
Johnson, G. A., Cofer, G. P., Fubara, B., Gewalt, S. L., Hedlund, L. W., & Maronpot, R. R. (2002). Magnetic resonance histology for morphologic phenotyping. J Magn Reson Imaging, 16(4), 423–429. https://doi.org/10.1002/jmri.10175Full Text Link to Item
-
Burg, K. J. L., Delnomdedieu, M., Beiler, R. J., Culberson, C. R., Greene, K. G., Halberstadt, C. R., … Johnson, G. A. (2002). Application of magnetic resonance microscopy to tissue engineering: a polylactide model. J Biomed Mater Res, 61(3), 380–390. https://doi.org/10.1002/jbm.10146Full Text Link to Item
-
Gareau, P. J., Wymore, A. C., Cofer, G. P., & Johnson, G. A. (2002). Imaging inflammation: direct visualization of perivascular cuffing in EAE by magnetic resonance microscopy. J Magn Reson Imaging, 16(1), 28–36. https://doi.org/10.1002/jmri.10136Full Text Link to Item
-
Möller, H. E., Chen, X. J., Saam, B., Hagspiel, K. D., Johnson, G. A., Altes, T. A., … Kauczor, H.-U. (2002). MRI of the lungs using hyperpolarized noble gases. Magn Reson Med, 47(6), 1029–1051. https://doi.org/10.1002/mrm.10173Full Text Link to Item
-
Johnson, G. A., Cofer, G. P., Gewalt, S. L., & Hedlund, L. W. (2002). Morphologic phenotyping with MR microscopy: the visible mouse. Radiology, 222(3), 789–793. https://doi.org/10.1148/radiol.2223010531Full Text Link to Item
-
Gupta, A. K., Johnson, G. A., & Nelson, R. C. (2002). Optimization of eight-element multi-detector helical CT for imaging the abdomen. Radiology, 222(2), 589–589.
-
Brau, A. C. S., Wheeler, C. T., Hedlund, L. W., & Johnson, G. A. (2002). Fiber-optic stethoscope: a cardiac monitoring and gating system for magnetic resonance microscopy. Magn Reson Med, 47(2), 314–321. https://doi.org/10.1002/mrm.10049Full Text Link to Item
-
Hedlund, L. W., & Johnson, G. A. (2002). Mechanical ventilation for imaging the small animal lung. Ilar J, 43(3), 159–174. https://doi.org/10.1093/ilar.43.3.159Full Text Link to Item
-
Spielmann, A. L., Nelson, R. C., Lowry, C. R., Johnson, G. A., Sundaramoothy, G., Sheafor, D. H., & Paulson, E. K. (2002). Liver: single breath-hold dynamic subtraction CT with multi-detector row helical technology feasibility study. Radiology, 222(1), 278–283. https://doi.org/10.1148/radiol.2221010190Full Text Link to Item
-
Johnson, G. A., & Hedlund, L. W. (2002). Image based phenotyping: The visible mouse. Faseb Journal, 16(5), A1091–A1091.Link to Item
-
Frush, D. P., Yoshizumi, T. T., Paulson, E. K., & Johnson, G. A. (2001). Radiation dose from helical CT in children: Comparison of multi-slice and single-slice protocols. Radiology, 221, 246–246.Link to Item
-
Paulson, E. K., Yoshizumi, T. T., Frush, D. P., & Johnson, G. A. (2001). Multi-detector vs single-detector CT: The organ doses are higher than you think. Radiology, 221, 403–403.Link to Item
-
Tengowski, M. W., Suddarth, S. A., Cofer, G. P., Wheeler, C. T., Botts, S., Fasulo, L. M., … Johnson, G. A. (2001). Using technology to develop a hepatic lipidosis blomarker in the rat. Molecular Biology of the Cell, 12, 261A-261A.Link to Item
-
Kelly, S. J., Delnomdedieu, M., Oliverio, M. I., Williams, L. D., Saifer, M. G. P., Sherman, M. R., … Hershfield, M. S. (2001). Diabetes insipidus in uricase-deficient mice: a model for evaluating therapy with poly(ethylene glycol)-modified uricase. J Am Soc Nephrol, 12(5), 1001–1009. https://doi.org/10.1681/ASN.V1251001Full Text Link to Item
-
Johnson, G. A., Cofer, G. P., Hedlund, L. W., Maronpot, R. R., & Suddarth, S. A. (2001). Registered (1)H and (3)He magnetic resonance microscopy of the lung. Magn Reson Med, 45(3), 365–370. https://doi.org/10.1002/1522-2594(200103)45:3<365::aid-mrm1047>3.0.co;2-0Full Text Link to Item
-
Möller, H. E., Hedlund, L. W., Chen, X. J., Carey, M. R., Chawla, M. S., Wheeler, C. T., & Johnson, G. A. (2001). Measurements of hyperpolarized gas properties in the lung. Part III: (3)He T(1). Magn Reson Med, 45(3), 421–430. https://doi.org/10.1002/1522-2594(200103)45:3<421::aid-mrm1055>3.0.co;2-kFull Text Link to Item
-
Tengowski, M. W., Hedlund, L. W., Guyot, D. J., Burkhardt, J. E., & Johnson, G. A. (2000). Magnetic resonance microscopy predicts findings in a theophylline-induced rat model of reproductive toxicity. Molecular Biology of the Cell, 11, 125A-125A.Link to Item
-
Chen, X. J., Hedlund, L. W., Möller, H. E., Chawla, M. S., Maronpot, R. R., & Johnson, G. A. (2000). Detection of emphysema in rat lungs by using magnetic resonance measurements of 3He diffusion. Proc Natl Acad Sci U S A, 97(21), 11478–11481. https://doi.org/10.1073/pnas.97.21.11478Full Text Link to Item
-
Hedlund, L. W., Cofer, G. P., Owen, S. J., & Allan Johnson, G. (2000). MR-compatible ventilator for small animals: computer-controlled ventilation for proton and noble gas imaging. Magn Reson Imaging, 18(6), 753–759. https://doi.org/10.1016/s0730-725x(00)00154-5Full Text Link to Item
-
Benveniste, H., Kim, K., Zhang, L., & Johnson, G. A. (2000). Magnetic resonance microscopy of the C57BL mouse brain. Neuroimage, 11(6 Pt 1), 601–611. https://doi.org/10.1006/nimg.2000.0567Full Text Link to Item
-
Hedlund, L. W., Möller, H. E., Chen, X. J., Chawla, M. S., Cofer, G. P., & Johnson, G. A. (2000). Mixing oxygen with hyperpolarized (3)He for small-animal lung studies. Nmr Biomed, 13(4), 202–206. https://doi.org/10.1002/1099-1492(200006)13:4<202::aid-nbm645>3.0.co;2-jFull Text Link to Item
-
Chawla, M. S., Chen, X. J., Cofer, G. P., Hedlund, L. W., Kerby, M. B., Ottoboni, T. B., & Johnson, G. A. (2000). Hyperpolarized 3He microspheres as a novel vascular signal source for MRI. Magn Reson Med, 43(3), 440–445. https://doi.org/10.1002/(sici)1522-2594(200003)43:3<440::aid-mrm16>3.0.co;2-mFull Text Link to Item
-
Nugent, A. C., & Johnson, G. A. (2000). T1rho imaging using magnetization-prepared projection encoding (MaPPE). Magn Reson Med, 43(3), 421–428. https://doi.org/10.1002/(sici)1522-2594(200003)43:3<421::aid-mrm14>3.0.co;2-xFull Text Link to Item
-
Lester, D. S., Pine, P. S., Delnomdedieu, M., Johannessen, J. N., & Johnson, G. A. (2000). Virtual neuropathology: three-dimensional visualization of lesions due to toxic insult. Toxicol Pathol, 28(1), 100–104. https://doi.org/10.1177/019262330002800112Full Text Link to Item
-
Oliverio, M. I., Delnomdedieu, M., Best, C. F., Li, P., Morris, M., Callahan, M. F., … Coffman, T. M. (2000). Abnormal water metabolism in mice lacking the type 1A receptor for ANG II. Am J Physiol Renal Physiol, 278(1), F75–F82. https://doi.org/10.1152/ajprenal.2000.278.1.F75Full Text Link to Item
-
Lester, D. S., Johannessen, J. N., Pine, P. S., McGregor, G. N., & Johnson, G. A. (1999). Virtual neuropathology: A new approach to preclinical pathology using magnetic resonance imaging microscopy. Spectroscopy (Santa Monica), 14(7), 17–22.
-
Benveniste, H., Einstein, G., Kim, K. R., Hulette, C., & Johnson, G. A. (1999). Detection of neuritic plaques in Alzheimer's disease by magnetic resonance microscopy. Proc Natl Acad Sci U S A, 96(24), 14079–14084. https://doi.org/10.1073/pnas.96.24.14079Full Text Link to Item
-
Nelson, R. C., Johnson, G. A., Spielman, A. L., Lowry, C. R., Sundaramoorthy, G., & Sheafor, D. H. (1999). Single breath-hold dynamic subtraction CT of the liver using-multidetector helical technology. Radiology, 213P, 125–125.
-
Chen, X. J., Möller, H. E., Chawla, M. S., Cofer, G. P., Driehuys, B., Hedlund, L. W., & Johnson, G. A. (1999). Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part I: diffusion coefficient. Magn Reson Med, 42(4), 721–728. https://doi.org/10.1002/(sici)1522-2594(199910)42:4<721::aid-mrm14>3.0.co;2-dFull Text Link to Item
-
Chen, X. J., Möller, H. E., Chawla, M. S., Cofer, G. P., Driehuys, B., Hedlund, L. W., … Johnson, G. A. (1999). Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part II: T *(2). Magn Reson Med, 42(4), 729–737. https://doi.org/10.1002/(sici)1522-2594(199910)42:4<729::aid-mrm15>3.0.co;2-2Full Text Link to Item
-
Benveniste, H. D., Kim, K. R., Hedlund, L. W., Johnson, G. A., & Friedman, A. H. (1999). Cerebral hemorrhage and edema following brain biopsy in rats: Significance of mean arterial blood pressure. Anesthesiology, 91(3A), U371–U371.Link to Item
-
Hurlston, S. E., Brey, W. W., Suddarth, S. A., & Johnson, G. A. (1999). A high-temperature superconducting Helmholtz probe for microscopy at 9.4 T. Magn Reson Med, 41(5), 1032–1038. https://doi.org/10.1002/(sici)1522-2594(199905)41:5<1032::aid-mrm23>3.0.co;2-xFull Text Link to Item
-
Möller, H. E., Chawla, M. S., Chen, X. J., Driehuys, B., Hedlund, L. W., Wheeler, C. T., & Johnson, G. A. (1999). Magnetic resonance angiography with hyperpolarized 129Xe dissolved in a lipid emulsion. Magn Reson Med, 41(5), 1058–1064. https://doi.org/10.1002/(sici)1522-2594(199905)41:5<1058::aid-mrm26>3.0.co;2-cFull Text Link to Item
-
Viallon, M., Cofer, G. P., Suddarth, S. A., Möller, H. E., Chen, X. J., Chawla, M. S., … Johnson, G. A. (1999). Functional MR microscopy of the lung using hyperpolarized 3He. Magn Reson Med, 41(4), 787–792. https://doi.org/10.1002/(sici)1522-2594(199904)41:4<787::aid-mrm18>3.0.co;2-4Full Text Link to Item
-
Möller, H. E., Chen, X. J., Chawla, M. S., Cofer, G. P., Driehuys, B., Hedlund, L. W., … Johnson, G. A. (1999). Sensitivity and resolution in 3D NMR microscopy of the lung with hyperpolarized noble gases. Magn Reson Med, 41(4), 800–808. https://doi.org/10.1002/(sici)1522-2594(199904)41:4<800::aid-mrm20>3.0.co;2-kFull Text Link to Item
-
Lester, D. S., Lyon, R. C., McGregor, G. N., Engelhardt, R. T., Schmued, L. C., Johnson, G. A., & Johannessen, J. N. (1999). 3-Dimensional visualization of lesions in rat brain using magnetic resonance imaging microscopy. Neuroreport, 10(4), 737–741. https://doi.org/10.1097/00001756-199903170-00014Full Text Link to Item
-
Miller, J. R., Hurlston, S. E., Ma, Q. Y., Face, D. W., Kountz, D. J., MacFall, J. R., … Johnson, G. A. (1999). Performance of a high-temperature superconducting probe for in vivo microscopy at 2.0 T. Magn Reson Med, 41(1), 72–79. https://doi.org/10.1002/(sici)1522-2594(199901)41:1<72::aid-mrm11>3.0.co;2-aFull Text Link to Item
-
Benveniste, H., Qui, H., Hedlund, L. W., Hüttemeier, P. C., Steele, S. M., & Johnson, G. A. (1999). In vivo diffusion-weighted magnetic resonance microscopy of rat spinal cord: effect of ischemia and intrathecal hyperbaric 5% lidocaine. Reg Anesth Pain Med, 24(4), 311–318. https://doi.org/10.1016/s1098-7339(99)90104-9Full Text Link to Item
-
Smith, B. R., Huff, D. S., & Johnson, G. A. (1999). Magnetic resonance imaging of embryos: an Internet resource for the study of embryonic development. Comput Med Imaging Graph, 23(1), 33–40. https://doi.org/10.1016/s0895-6111(98)00061-5Full Text Link to Item
-
Möller, H. E., Chen, X. J., Chawla, M. S., Driehuys, B., Hedlund, L. W., & Johnson, G. A. (1998). Signal dynamics in magnetic resonance imaging of the lung with hyperpolarized noble gases. J Magn Reson, 135(1), 133–143. https://doi.org/10.1006/jmre.1998.1563Full Text Link to Item
-
Chawla, M. S., Chen, X. J., Möller, H. E., Cofer, G. P., Wheeler, C. T., Hedlund, L. W., & Johnson, G. A. (1998). In vivo magnetic resonance vascular imaging using laser-polarized 3He microbubbles. Proc Natl Acad Sci U S A, 95(18), 10832–10835. https://doi.org/10.1073/pnas.95.18.10832Full Text Link to Item
-
Qiu, H. H., Hedlund, L. W., Neuman, M. R., Edwards, C. R., Black, R. D., Cofer, G. P., & Johnson, G. A. (1998). Measuring the progression of foreign-body reaction to silicone implants using in vivo MR microscopy. Ieee Trans Biomed Eng, 45(7), 921–927. https://doi.org/10.1109/10.686800Full Text Link to Item
-
Chen, X. J., Chawla, M. S., Cofer, G. P., Hedlund, L. W., Möller, H. E., & Johnson, G. A. (1998). Hyperpolarized 3He NMR lineshape measurements in the live guinea pig lung. Magn Reson Med, 40(1), 61–65. https://doi.org/10.1002/mrm.1910400109Full Text Link to Item
-
Smith, B. R., Sattuck, M. D., Hedlund, L. W., & Johnson, G. A. (1998). Time-course imaging of rat embryos in utero with magnetic resonance microscopy (vol 39, pg 673, 1998). Magnetic Resonance in Medicine, 39(6), CP2–CP2.
-
Smith, B. R., Shattuck, M. D., Hedlund, L. W., & Johnson, G. A. (1998). Time-course imaging of rat embryos in utero with magnetic resonance microscopy. Magn Reson Med, 39(4), 673–677. https://doi.org/10.1002/mrm.1910390424Full Text Link to Item
-
Delnomdedieu, M., Hedlund, L. W., Maronpot, R. R., & Johnson, G. A. (1998). Magnetic resonance microscopy and histopathology: comparative approach of bromobenzene-induced hepatotoxicity in the rat. Hepatology, 27(2), 526–532. https://doi.org/10.1002/hep.510270229Full Text Link to Item
-
Allan Johnson, G., Hedlund, L., & MacFall, J. (1998). A new window into the lung. Physics World, 11(11), 35–38. https://doi.org/10.1088/2058-7058/11/11/28Full Text
-
Benveniste, H., Einstein, G., Kim, K. R., & Allan Johnson, G. (1998). Magnetic resonance microscopy of Alzheimer's disease: Senile plaques - A whiter shade of pale? Neuroimage, 7(4 PART II). https://doi.org/10.1016/s1053-8119(18)31352-1Full Text
-
Smith, B. R., Sattuck, M. D., Hedlund, L. W., & Johnson, G. A. (1998). Erratum: Time-course imaging of rat embryos in utero with magnetic resonance microscopy (Magnetic Resonance in Medicine (1998) 39 (673-677)). Magnetic Resonance in Medicine, 39(6).
-
Benveniste, H., Qui, H., Hedlund, L. W., D’Ercole, F., & Johnson, G. A. (1998). Spinal cord neural anatomy in rats examined by in vivo magnetic resonance microscopy. Reg Anesth Pain Med, 23(6), 589–599. https://doi.org/10.1016/s1098-7339(98)90087-6Full Text Link to Item
-
Chen, X. J., Chawla, M. S., Hedlund, L. W., Möller, H. E., MacFall, J. R., & Johnson, G. A. (1998). MR microscopy of lung airways with hyperpolarized 3He. Magn Reson Med, 39(1), 79–84. https://doi.org/10.1002/mrm.1910390113Full Text Link to Item
-
Levron, D., Walter, D. K., Appelt, S., Fitzgerald, R. J., Kahn, D., Korbly, S. E., … al, E. (1998). Magnetic resonance imaging of hyperpolarized 129Xe produced by spin exchange with diode-laser pumped Cs. Applied Physics Letters, 73(18), 2666–2668. https://doi.org/10.1063/1.122547Full Text
-
Zhou, X., Liang, Z. P., Gewalt, S. L., Cofer, G. P., Lauterbur, P. C., & Johnson, G. A. (1998). A fast spin echo technique with circular sampling. Magn Reson Med, 39(1), 23–27. https://doi.org/10.1002/mrm.1910390106Full Text Link to Item
-
Bcnveniste, H., Hüttemeier, P. C., Qiu, H., Steele, S., Hedlund, L. W., & Allan Johnson, G. (1997). Magnetic resonance imaging of continuous spinal anesthesia with hyperbaric lidocaine: Root or white matter lesion? Regional Anesthesia, 22(2 SUPPL.), 15.
-
Shattuck, M. D., Gewalt, S. L., Glover, G. H., Hedlund, L. W., & Johnson, G. A. (1997). MR microimaging of the lung using volume projection encoding. Magn Reson Med, 38(6), 938–942. https://doi.org/10.1002/mrm.1910380613Full Text Link to Item
-
Qiu, H. H., Cofer, G. P., Hedlund, L. W., & Johnson, G. A. (1997). Automated feedback control of body temperature for small animal studies with MR microscopy. Ieee Trans Biomed Eng, 44(11), 1107–1113. https://doi.org/10.1109/10.641338Full Text Link to Item
-
Johnson, G. A., Cates, G., Chen, X. J., Cofer, G. P., Driehuys, B., Happer, W., … Swartz, J. (1997). Dynamics of magnetization in hyperpolarized gas MRI of the lung. Magn Reson Med, 38(1), 66–71. https://doi.org/10.1002/mrm.1910380111Full Text Link to Item
-
Johnson, G. A., Benveniste, H., Engelhardt, R. T., Qiu, H., & Hedlund, L. W. (1997). Magnetic resonance microscopy in basic studies of brain structure and function. Ann N Y Acad Sci, 820, 139–147. https://doi.org/10.1111/j.1749-6632.1997.tb46193.xFull Text Link to Item
-
Vandemark, R. M., Fay, M. E., Porter, F. R., & Johnson, G. A. (1997). Digital image-intensifier radiography at a level I trauma center. Ajr Am J Roentgenol, 168(4), 944–946. https://doi.org/10.2214/ajr.168.4.9124145Full Text Link to Item
-
Shattuck, M. D., Behringer, R. P., Johnson, G. A., & Georgiadis, J. G. (1997). Convection and flow in porous media. Part 1. Visualization by magnetic resonance imaging. Journal of Fluid Mechanics, 332, 215–245. https://doi.org/10.1017/s0022112096003990Full Text
-
Chotas, H. G., Floyd, C. E., Johnson, G. A., & Ravin, C. E. (1997). Quality control phantom for digital chest radiography. Radiology, 202(1), 111–116. https://doi.org/10.1148/radiology.202.1.8988199Full Text Link to Item
-
Hurlston, S. E., Cofer, G. P., & Johnson, G. A. (1997). Optimized radiofrequency coils for increased signal-to-noise ratio in magnetic resonance microscopy. International Journal of Imaging Systems and Technology, 8(3), 277–284. https://doi.org/10.1002/(SICI)1098-1098(1997)8:3<277::AID-IMA5>3.0.CO;2-7Full Text
-
Zimmer, C., Wright, S. C., Engelhardt, R. T., Johnson, G. A., Kramm, C., Breakefield, X. O., & Weissleder, R. (1997). Tumor cell endocytosis imaging facilitates delineation of the glioma-brain interface. Exp Neurol, 143(1), 61–69. https://doi.org/10.1006/exnr.1996.6350Full Text Link to Item
-
McFall, J. S., & Johnson, G. A. (1997). Root form and function meshed by MRI. Plant Physiology, 114(3), 20002–20002.Link to Item
-
Qiu, H., Hedlund, L. W., Gewalt, S. L., Benveniste, H., Bare, T. M., & Johnson, G. A. (1997). Progression of a focal ischemic lesion in rat brain during treatment with a novel glycine/NMDA antagonist: an in vivo three-dimensional diffusion-weighted MR microscopy study. J Magn Reson Imaging, 7(4), 739–744. https://doi.org/10.1002/jmri.1880070421Full Text Link to Item
-
Chotas, H. G., Floyd, C. E., Johnson, G. A., & Ravin, C. E. (1996). Quality control phantom for digital chest radiography. Radiology, 201, 685–685.Link to Item
-
Johnson, G. A., & Hedlund, L. W. (1996). Functional imaging of the lung. Nat Med, 2(11), 1192. https://doi.org/10.1038/nm1196-1192Full Text Link to Item
-
MacFall, J. R., Charles, H. C., Black, R. D., Middleton, H., Swartz, J. C., Saam, B., … Ravin, C. E. (1996). Human lung air spaces: potential for MR imaging with hyperpolarized He-3. Radiology, 200(2), 553–558. https://doi.org/10.1148/radiology.200.2.8685356Full Text Link to Item
-
Hall, W. L., Benveniste, H., Hedlund, L. W., & Johnson, G. A. (1996). A new in vivo method for quantitative analysis of stroke lesions using diffusion-weighted magnetic resonance microscopy. Neuroimage, 3(3 Pt 1), 158–166. https://doi.org/10.1006/nimg.1996.0017Full Text Link to Item
-
Black, R. D., Middleton, H. L., Cates, G. D., Cofer, G. P., Driehuys, B., Happer, W., … Swartz, J. C. (1996). In vivo He-3 MR images of guinea pig lungs. Radiology, 199(3), 867–870. https://doi.org/10.1148/radiology.199.3.8638019Full Text Link to Item
-
Engelhardt, R. T., & Johnson, G. A. (1996). T1 rho relaxation and its application to MR histology. Magn Reson Med, 35(5), 781–786. https://doi.org/10.1002/mrm.1910350520Full Text Link to Item
-
Johnson, G., Thomson, D. J., Wu, E. X., & Williams, S. C. R. (1996). Multiple-window spectrum estimation applied to in vivo NMR spectroscopy. Journal of Magnetic Resonance Series B, 110(2), 138–149.
-
Delnomdedieu, M., Hedlund, L. W., Johnson, G. A., & Maronpot, R. R. (1996). Magnetic resonance microscopy--a new tool for the toxicologic pathologist. Toxicol Pathol, 24(1), 36–44. https://doi.org/10.1177/019262339602400106Full Text Link to Item
-
Smith, B. R., Linney, E., Huff, D. S., & Johnson, G. A. (1996). Magnetic resonance microscopy of embryos. Comput Med Imaging Graph, 20(6), 483–490. https://doi.org/10.1016/s0895-6111(96)00046-8Full Text Link to Item
-
Zhou, X., Maronpot, R. R., Hedlund, L. W., Cofer, G. P., & Johnson, G. A. (1995). Detection of bromobenzene-induced hepatocellular necrosis using magnetic resonance microscopy. Magn Reson Med, 34(6), 853–857. https://doi.org/10.1002/mrm.1910340610Full Text Link to Item
-
Feinberg, D. A., & Johnson, G. (1995). A methodology for co-registering abdominal MR images over multiple breath-holds. Magn Reson Med, 34(5), 770–774. https://doi.org/10.1002/mrm.1910340517Full Text Link to Item
-
Shattuck, M. D., Behringer, R. P., Johnson, G. A., & Georgiadis, J. G. (1995). Onset and Stability of Convection in Porous Media: Visualization by Magnetic Resonance Imaging. Phys Rev Lett, 75(10), 1934–1937. https://doi.org/10.1103/PhysRevLett.75.1934Full Text Link to Item
-
MACFALL, I. S., & JOHNSON, G. A. (1995). 3-DIMENSIONAL ROOT-GROWTH, TURNOVER AND TRANSPORT AS SEEN WITH MAGNETIC-RESONANCE MICROSCOPY. Plant Physiology, 108(2), 31–31.Link to Item
-
Summers, R. M., Hedlund, L. W., Cofer, G. P., Gottsman, M. B., Manibo, J. F., & Johnson, G. A. (1995). MR microscopy of the rat carotid artery after balloon injury by using an implanted imaging coil. Magn Reson Med, 33(6), 785–789. https://doi.org/10.1002/mrm.1910330607Full Text Link to Item
-
Middleton, H., Black, R. D., Saam, B., Cates, G. D., Cofer, G. P., Guenther, R., … Juvan, K. (1995). MR imaging with hyperpolarized 3He gas. Magn Reson Med, 33(2), 271–275. https://doi.org/10.1002/mrm.1910330219Full Text Link to Item
-
Black, R. D., Early, T. A., & Johnson, G. A. (1995). Performance of a High-Temperature Superconducting Resonator for High-Field Imaging. Journal of Magnetic Resonance, Series A, 113(1), 74–80. https://doi.org/10.1006/jmra.1995.1058Full Text
-
Arnder, L., Zhou, X., Cofer, G. P., Hedlund, L. W., & Johnson, G. A. (1994). Magnetic resonance microscopy of the rat carotid artery at 300 megahertz. Invest Radiol, 29(9), 822–826. https://doi.org/10.1097/00004424-199409000-00004Full Text Link to Item
-
Mellin, A. F., Cofer, G. P., Smith, B. R., Suddarth, S. A., Hedlund, L. W., & Johnson, G. A. (1994). Three dimensional magnetic resonance microangiography of rat neurovasculature. Magn Reson Med, 32(2), 199–205. https://doi.org/10.1002/mrm.1910320208Full Text Link to Item
-
Zhou, X., Maronpot, R. R., Cofer, G. P., Hedlund, L. W., & Johnson, G. A. (1994). Studies on bromobenzene-induced hepatotoxicity using in vivo MR microscopy with surgically implanted RF coils. Magn Reson Med, 31(6), 619–627. https://doi.org/10.1002/mrm.1910310607Full Text Link to Item
-
Henson, M. M., Henson, O. W., Gewalt, S. L., Wilson, J. L., & Johnson, G. A. (1994). Imaging the cochlea by magnetic resonance microscopy. Hear Res, 75(1–2), 75–80. https://doi.org/10.1016/0378-5955(94)90058-2Full Text Link to Item
-
Hsu, J. C., Johnson, G. A., Smith, W. M., Reimer, K. A., & Ideker, R. E. (1994). Magnetic resonance imaging of chronic myocardial infarcts in formalin-fixed human autopsy hearts. Circulation, 89(5), 2133–2140. https://doi.org/10.1161/01.cir.89.5.2133Full Text Link to Item
-
Smith, B. R., Johnson, G. A., Groman, E. V., & Linney, E. (1994). Magnetic resonance microscopy of mouse embryos. Proc Natl Acad Sci U S A, 91(9), 3530–3533. https://doi.org/10.1073/pnas.91.9.3530Full Text Link to Item
-
Boyko, O. B., Alston, S. R., Fuller, G. N., Hulette, C. M., Johnson, G. A., & Burger, P. C. (1994). Utility of postmortem magnetic resonance imaging in clinical neuropathology. Arch Pathol Lab Med, 118(3), 219–225.Link to Item
-
MacFall, J. S., & Johnson, G. A. (1994). The architecture of plant vasculature and transport as seen with magnetic resonance microscopy. Canadian Journal of Botany, 72(11), 1561–1573. https://doi.org/10.1139/b94-193Full Text
-
MacFall, J. S., Spaine, P., Doudrick, R., & Johnson, G. A. (1994). Alterations in growth and water-transport processes in fusiform rust galls of pine, determined by magnetic resonance microscopy. Phytopathology, 84(3), 288–293. https://doi.org/10.1094/Phyto-84-288Full Text
-
Smith, W. M., Hsu, J. C. M., Johnson, G. A., Reimer, K. A., & Ideker, R. E. (1993). Detection of infarcted tissue the heart by magnetic resonance imaging. Proceedings of the Annual Conference on Engineering in Medicine and Biology, 15(pt 1), 485–486.
-
Beaulieu, C. F., Zhou, X., Cofer, G. P., & Johnson, G. A. (1993). Diffusion-weighted MR microscopy with fast spin-echo. Magn Reson Med, 30(2), 201–206. https://doi.org/10.1002/mrm.1910300208Full Text Link to Item
-
Zhou, X., Cofer, G. P., Suddarth, S. A., & Johnson, G. A. (1993). High-field MR microscopy using fast spin-echoes. Magn Reson Med, 30(1), 60–67. https://doi.org/10.1002/mrm.1910300110Full Text Link to Item
-
Johnson, G. A., Benveniste, H., Black, R. D., Hedlund, L. W., Maronpot, R. R., & Smith, B. R. (1993). Histology by magnetic resonance microscopy. Magn Reson Q, 9(1), 1–30.Link to Item
-
Black, R. D., Early, T. A., Roemer, P. B., Mueller, O. M., Mogro-Campero, A., Turner, L. G., & Johnson, G. A. (1993). A high-temperature superconducting receiver for nuclear magnetic resonance microscopy. Science, 259(5096), 793–795. https://doi.org/10.1126/science.8430331Full Text Link to Item
-
Huesgen, C. T., Burger, P. C., Crain, B. J., & Johnson, G. A. (1993). In vitro MR microscopy of the hippocampus in Alzheimer's disease. Neurology, 43(1), 145–152. https://doi.org/10.1212/wnl.43.1_part_1.145Full Text Link to Item
-
VERES, J. S., COFER, G. P., & JOHNSON, G. A. (1993). Magnetic resonance imaging of leaves. New Phytologist, 123(4), 769–774. https://doi.org/10.1111/j.1469-8137.1993.tb03788.xFull Text
-
Gewalt, S. L., Glover, G. H., Hedlund, L. W., Cofer, G. P., MacFall, J. R., & Johnson, G. A. (1993). MR microscopy of the rat lung using projection reconstruction. Magn Reson Med, 29(1), 99–106. https://doi.org/10.1002/mrm.1910290117Full Text Link to Item
-
Zhou, X., Liang, Z. P., Cofer, G. P., Beaulieu, C. F., Suddarth, S. A., & Johnson, G. A. (1993). Reduction of ringing and blurring artifacts in fast spin-echo imaging. J Magn Reson Imaging, 3(5), 803–807. https://doi.org/10.1002/jmri.1880030518Full Text Link to Item
-
Macfall, J. S., Pfeffer, P. E., Rolin, D. B., Macfall, J. R., & Johnson, G. A. (1992). Observation of the Oxygen Diffusion Barrier in Soybean (Glycine max) Nodules with Magnetic Resonance Microscopy. Plant Physiol, 100(4), 1691–1697. https://doi.org/10.1104/pp.100.4.1691Full Text Link to Item
-
Brouwer, M., Engel, D. W., Bonaventura, J., & Johnson, G. A. (1992). In vivo magnetic resonance imaging of the blue crab, Callinectes sapidus: effect of cadmium accumulation in tissues on proton relaxation properties. J Exp Zool, 263(1), 32–40. https://doi.org/10.1002/jez.1402630105Full Text Link to Item
-
Benveniste, H., Hedlund, L. W., & Johnson, G. A. (1992). Mechanism of detection of acute cerebral ischemia in rats by diffusion-weighted magnetic resonance microscopy. Stroke, 23(5), 746–754. https://doi.org/10.1161/01.str.23.5.746Full Text Link to Item
-
Banson, M. L., Cofer, G. P., Black, R., & Johnson, G. A. (1992). A probe for specimen magnetic resonance microscopy. Invest Radiol, 27(2), 157–164. https://doi.org/10.1097/00004424-199202000-00013Full Text Link to Item
-
Banson, M. L., Cofer, G. P., Hedlund, L. W., & Johnson, G. A. (1992). Surface coil imaging of rat spine at 7.0 T. Magn Reson Imaging, 10(6), 929–934. https://doi.org/10.1016/0730-725x(92)90447-8Full Text Link to Item
-
Smith, B. R., Effmann, E. L., & Johnson, G. A. (1992). MR microscopy of chick embryo vasculature. J Magn Reson Imaging, 2(2), 237–240. https://doi.org/10.1002/jmri.1880020220Full Text Link to Item
-
Veres, J. S., Cofer, G. P., & Johnson, G. A. (1991). Distinguishing Plant Tissues with Magnetic Resonance Microscopy. American Journal of Botany, 78(12), 1704–1704. https://doi.org/10.2307/2444849Full Text
-
Shattuck, M., Behringer, R., Geordiadis, J., & Johnson, G. A. (1991). Magnetic resonance imaging of interstitial velocity distributions in porous media. American Society of Mechanical Engineers, Fluids Engineering Division (Publication) Fed, 125, 39–45.
-
Chotas, H. G., Van Metter, R. L., Johnson, G. A., & Ravin, C. E. (1991). Small object contrast in AMBER and conventional chest radiography. Radiology, 180(3), 853–859. https://doi.org/10.1148/radiology.180.3.1871306Full Text Link to Item
-
MacFall, J. R., Maki, J. H., Johnson, G. A., Hedlund, L. W., & Cofer, G. P. (1991). Pre- and postmortem diffusion coefficients in rat neural and muscle tissues. Magn Reson Med, 20(1), 89–99. https://doi.org/10.1002/mrm.1910200110Full Text Link to Item
-
Johnson, G. A., & Maki, J. H. (1991). In vivo measurement of proton diffusion in the presence of coherent motion. Invest Radiol, 26(6), 540–545. https://doi.org/10.1097/00004424-199106000-00006Full Text Link to Item
-
MacFall, J. R., Maki, J. H., Johnson, G. A., Hedlund, L., Benveniste, H., & Copher, G. (1991). Diffusion/microcirculation MRI in the rat brain. Magn Reson Med, 19(2), 305–310. https://doi.org/10.1002/mrm.1910190219Full Text Link to Item
-
Hedlund, L. W., Maronpot, R. R., Johnson, G. A., Cofer, G. P., Mills, G. I., & Wheeler, C. T. (1991). Magnetic resonance microscopy of toxic renal injury induced by bromoethylamine in rats. Fundam Appl Toxicol, 16(4), 787–797. https://doi.org/10.1016/0272-0590(91)90164-yFull Text Link to Item
-
Suddarth, S. A., & Johnson, G. A. (1991). Three-dimensional MR microscopy with large arrays. Magn Reson Med, 18(1), 132–141. https://doi.org/10.1002/mrm.1910180114Full Text Link to Item
-
Benveniste, H., Cofer, G. P., Piantadosi, C. A., Davis, J. N., & Johnson, G. A. (1991). Quantitative proton magnetic resonance imaging in focal cerebral ischemia in rat brain. Stroke, 22(2), 259–268. https://doi.org/10.1161/01.str.22.2.259Full Text Link to Item
-
BAXTER, G. W., LEONE, R., JOHNSON, G. A., & BEHRINGER, R. P. (1991). TIME-DEPENDENCE, SCALING AND PATTERN-FORMATION FOR FLOWING SAND. European Journal of Mechanics B Fluids, 10(2), 181–186.Link to Item
-
Hedlund, L. W., Maronpot, R. R., Johnson, G. A., Cofer, G. P., Mills, G. I., & Wheeler, C. T. (1991). Magnetic resonance microscopy of toxic renal injury induced by Bromoethylamine in rats. Toxicological Sciences, 16(4), 787–797. https://doi.org/10.1093/toxsci/16.4.787Full Text
-
MACFALL, J. S., JOHNSON, G. A., & KRAMER, P. J. (1991). Comparative water uptake by roots of different ages in seedlings of loblolly pine (Pinus taeda L.). New Phytologist, 119(4), 551–560. https://doi.org/10.1111/j.1469-8137.1991.tb01047.xFull Text
-
Shattuck, M., Behringer, R., Geordiadis, J., & Johnson, G. A. (1991). Magnetic resonance imaging of interstitial velocity distributions in porous media.
-
Veres, J. S., Johnson, G. A., & Kramer, P. J. (1991). In vivo Magnetic Resonance Imaging of Blechnum Ferns: Changes in T1 and N (H) During Dehydration and Rehydration. American Journal of Botany, 78(1), 80–80. https://doi.org/10.2307/2445231Full Text
-
Maki, J. H., Benveniste, H., MacFall, J. R., & Johnson, G. A. (1991). Maximization of contrast-to-noise ratio to distinguish diffusion and microcirculatory flow. J Magn Reson Imaging, 1(1), 39–46. https://doi.org/10.1002/jmri.1880010105Full Text Link to Item
-
Maki, J. H., Benveniste, H., MacFall, J. R., Piantadosi, C. A., & Johnson, G. A. (1991). MR imaging of microcirculation in rat brain: correlation with carbon dioxide-induced changes in blood flow. J Magn Reson Imaging, 1(6), 673–681. https://doi.org/10.1002/jmri.1880010609Full Text Link to Item
-
Maki, J. H., MacFall, J. R., & Johnson, G. A. (1991). The use of gradient flow compensation to separate diffusion and microcirculatory flow in MRI. Magn Reson Med, 17(1), 95–107. https://doi.org/10.1002/mrm.1910170114Full Text Link to Item
-
Malisch, T. W., Hedlund, L. W., Suddarth, S. A., & Johnson, G. A. (1991). MR microscopy at 7.0 T: effects of brain iron. J Magn Reson Imaging, 1(3), 301–305. https://doi.org/10.1002/jmri.1880010308Full Text Link to Item
-
Shattuck, M., Behringer, R., Geordiadis, J., & Johnson, G. A. (1991). Magnetic resonance imaging of interstitial velocity distributions in porous media.
-
Brown, J. M., Kramer, P. J., Cofer, G. P., & Johnson, G. A. (1990). Use of nuclear magnetic resonance microscopy for noninvasive observations of root-soil water relations. Theoretical and Applied Climatology, 42(4), 229–236. https://doi.org/10.1007/BF00865983Full Text
-
Cassel, D. K., Brown, J. M., & Johnson, G. A. (1990). Computer tomographic analysis of water distribution and flow in porous media. Theoretical and Applied Climatology, 42(4), 223–228. https://doi.org/10.1007/BF00865982Full Text
-
MacFall, J. R., Benveniste, H., Maki, J., Johnson, G. A., Hedlund, L., & Copher, G. (1990). MR diffusion measurements in stroke models in rat brains. Proceedings of the Annual Conference on Engineering in Medicine and Biology, (pt 1), 67–68.
-
Farmer, T. H., Cofer, G. P., & Johnson, G. A. (1990). Maximizing contrast to noise with inductively coupled implanted coils. Invest Radiol, 25(5), 552–558. https://doi.org/10.1097/00004424-199005000-00013Full Text Link to Item
-
MacFall, J. S., Johnson, G. A., & Kramer, P. J. (1990). Observation of a water-depletion region surrounding loblolly pine roots by magnetic resonance imaging. Proc Natl Acad Sci U S A, 87(3), 1203–1207. https://doi.org/10.1073/pnas.87.3.1203Full Text Link to Item
-
Johnson, G. A., Chotas, H. G., Suddarth, S. A., Ziv, S. B., & Todd, B. E. (1990). Integrated network for medical imaging research. Proceedings of Spie the International Society for Optical Engineering, 1234 pt 1, 159–166.
-
Stern, R. L., Johnson, G. A., & Ravin, C. E. (1990). Magnetic resonance imaging of the thoracic cavity using a paused 3DFT acquisition technique. Magn Reson Imaging, 8(6), 747–753. https://doi.org/10.1016/0730-725x(90)90010-yFull Text Link to Item
-
Sherrier, R. H., Chotas, H. G., Johnson, G. A., Chiles, C., & Ravin, C. E. (1989). Image optimization in a computed-radiography/photostimulable-phosphor system. J Digit Imaging, 2(4), 212–219. https://doi.org/10.1007/BF03170408Full Text Link to Item
-
Dockery, S. E., Suddarth, S. A., & Johnson, G. A. (1989). Relaxation measurements at 300 MHz using MR microscopy. Magn Reson Med, 11(2), 182–192. https://doi.org/10.1002/mrm.1910110206Full Text Link to Item
-
Johnson, G. A., Thompson, M. B., Cofer, G. P., Campen, D., & Maronpot, R. R. (1989). Magnetic resonance imaging of hepatic neoplasms in the rat. Vet Pathol, 26(4), 303–308. https://doi.org/10.1177/030098588902600403Full Text Link to Item
-
Baxter, G. W., Behringer, R. P., Fagert, T., & Johnson, G. A. (1989). Pattern formation in flowing sand. Phys Rev Lett, 62(24), 2825–2828. https://doi.org/10.1103/PhysRevLett.62.2825Full Text Link to Item
-
Farmer, T. H., Johnson, G. A., Cofer, G. P., Maronpot, R. R., Dixon, D., & Hedlund, L. W. (1989). Implanted coil MR microscopy of renal pathology. Magn Reson Med, 10(3), 310–323. https://doi.org/10.1002/mrm.1910100304Full Text Link to Item
-
Stern, R. L., Cline, H. E., Johnson, G. A., & Ravin, C. E. (1989). Three-dimensional imaging of the thoracic cavity. Invest Radiol, 24(4), 282–288. https://doi.org/10.1097/00004424-198904000-00005Full Text Link to Item
-
Cofer, G. P., Brown, J. M., & Allan Johnson, G. (1989). In vivo magnetic resonance microscopy at 5 μm. Journal of Magnetic Resonance (1969), 83(3), 608–616. https://doi.org/10.1016/0022-2364(89)90354-5Full Text
-
Johnson, G. A., & Maronpot, R. R. (1989). Magnetic resonance microscopy of chemically-induced liver foci. Toxicol Pathol, 17(4 Pt 1), 613–616. https://doi.org/10.1177/0192623389017004106Full Text Link to Item
-
Maynor, C. H., Charles, H. C., Herfkens, R. J., Suddarth, S. A., & Johnson, G. A. (1989). Chemical shift imaging of atherosclerosis at 7.0 Tesla. Invest Radiol, 24(1), 52–60. https://doi.org/10.1097/00004424-198901000-00012Full Text Link to Item
-
Cline, H. E., Lorensen, W. E., Herfkens, R. J., Johnson, G. A., & Glover, G. H. (1989). Vascular morphology by three-dimensional magnetic resonance imaging. Magn Reson Imaging, 7(1), 45–54. https://doi.org/10.1016/0730-725x(89)90323-8Full Text Link to Item
-
Matyac, C. A., Cofer, G. P., Bailey, J. E., & Johnson, G. A. (1989). In Situ Observations of Root-gall Formation Using Nuclear Magnetic Resonance Imaging. J Nematol, 21(1), 131–134.Link to Item
-
DOCKERY, S., SUDDARTH, S. A., COFER, G. P., & JOHNSON, G. A. (1988). THE IMPACT OF INCREASED SPIN-LATTICE RELAXATION-TIME MICROSCOPY AT 7.0T. Investigative Radiology, 23(9), S20–S20.Link to Item
-
FARMER, T. H. R., JOHNSON, G. A., COFER, G. P., MARONPOT, R. R., & HEDLUND, L. W. (1988). MR MICROSCOPY OF NEPHROTOXIC ACUTE TUBULAR-NECROSIS IN THE RAT. Investigative Radiology, 23(9), S10–S10.Link to Item
-
MAKI, J. H., COFER, G. P., HEDLUND, L. W., MACFALL, J. R., & JOHNSON, G. A. (1988). MR MICROSCOPY USING DRIVEN EQUILIBRIUM (DEFT). Investigative Radiology, 23(9), S21–S21.Link to Item
-
MAYNOR, C. H., CHARLES, H. C., HERFKENS, R. J., SUDDARTH, S. A., & JOHNSON, G. A. (1988). INVITRO CHEMICAL-SHIFT IMAGING OF ATHEROSCLEROSIS AT 7.0-TESLA. Investigative Radiology, 23(9), S3–S3.Link to Item
-
STERN, R. L., CLINE, H. E., JOHNSON, G. A., & RAVIN, C. E. (1988). DEVELOPMENT OF A 3D RECONSTRUCTED-IMAGE SURGICAL PLANNING STATION. Investigative Radiology, 23(9), S60–S60.Link to Item
-
Brown, J. M., Thomas, J. F., Cofer, G. P., & Johnson, G. A. (1988). Magnetic Resonance Microscopy of Stem Tissues of Pelargonium hortorum. Botanical Gazette, 149(3), 253–259. https://doi.org/10.1086/337713Full Text
-
Sherrier, R. H., Suddarth, S. A., & Johnson, G. A. (1988). Film-Based Digital Tomosynthesis Of The Chest. Optical Engineering, 27(8). https://doi.org/10.1117/12.7976742Full Text
-
Effmann, E. L., Johnson, G. A., Smith, B. R., Talbott, G. A., & Cofer, G. (1988). Magnetic resonance microscopy of chick embryos in ovo. Teratology, 38(1), 59–65. https://doi.org/10.1002/tera.1420380109Full Text Link to Item
-
Spritzer, C. E., Vogler, J. B., Martinez, S., Garrett, W. E., Johnson, G. A., McNamara, M. J., … Herfkens, R. J. (1988). MR imaging of the knee: preliminary results with a 3DFT GRASS pulse sequence. Ajr Am J Roentgenol, 150(3), 597–603. https://doi.org/10.2214/ajr.150.3.597Full Text Link to Item
-
Sherrier, R. H., Chiles, C., Wilkinson, W. E., Johnson, G. A., & Ravin, C. E. (1988). Effects of image processing on nodule detection rates in digitized chest radiographs: ROC study of observer performance. Radiology, 166(2), 447–450. https://doi.org/10.1148/radiology.166.2.3336719Full Text Link to Item
-
Conner, W. E., Johnson, G. A., Cofer, G. P., & Dittrich, K. (1988). Magnetic resonance microscopy: in vivo sectioning of a developing insect. Experientia, 44(1), 11–12. https://doi.org/10.1007/BF01960223Full Text Link to Item
-
Maki, J. H., Johnson, G. A., Cofer, G. P., & MacFall, J. R. (1988). SNR improvement in NMR microscopy using DEFT. Journal of Magnetic Resonance (1969), 80(3), 482–492. https://doi.org/10.1016/0022-2364(88)90243-0Full Text
-
Dixon, D., Johnson, G. A., Cofer, G. P., Hedlund, L. W., & Maronpot, R. R. (1988). Magnetic resonance imaging (MRI): a new tool in experimental toxicologic pathology. Toxicol Pathol, 16(3), 386–391. https://doi.org/10.1177/019262338801600311Full Text Link to Item
-
Hollett, M. D., Cofer, G. P., & Johnson, G. A. (1987). In situ magnetic resonance microscopy. Invest Radiol, 22(12), 965–968. https://doi.org/10.1097/00004424-198712000-00009Full Text Link to Item
-
BROWN, J. M., KRAMER, P. J., COFER, G. P., & JOHNSON, G. A. (1987). MAGNETIC-RESONANCE-IMAGING OF ROOT-WATER DISTRIBUTION. Hortscience, 22(5), 1087–1087.Link to Item
-
Drayer, B. P., Burger, P., Hurwitz, B., Dawson, D., Cain, J., Leong, J., … Johnson, G. A. (1987). Magnetic resonance imaging in multiple sclerosis: decreased signal in thalamus and putamen. Ann Neurol, 22(4), 546–550. https://doi.org/10.1002/ana.410220418Full Text Link to Item
-
Hedlund, L., Cofer, G., Suddarth, S., & Johnson, G. A. (1987). 177. SMALL ANIMAL ANESTHESIA AND MONITORING DURING EXTENDED MR MICROSCOPY. Investigative Radiology, 22(9), S44–S44. https://doi.org/10.1097/00004424-198709000-00193Full Text
-
JOHNSON, G. A. (1987). RESOLUTION LIMITS IN MR - MR MICROSCOPY. Medical Physics, 14(3), 499–499.Link to Item
-
Johnson, G. A., Brown, J., & Kramer, P. J. (1987). Magnetic resonance microscopy of changes in water content in stems of transpiring plants. Proc Natl Acad Sci U S A, 84(9), 2752–2755. https://doi.org/10.1073/pnas.84.9.2752Full Text Link to Item
-
EFFMANN, E. L., JOHNSON, G. A., SMITH, B. R., TALBOTT, G. A., & COFER, G. (1987). MAGNETIC-RESONANCE MICROSCOPY OF LIVE CHICK-EMBRYOS IN OVO. Teratology, 35(2), A44–A44.Link to Item
-
Johnson, G. A., Thompson, M. B., & Drayer, B. P. (1987). Three-dimensional MRI microscopy of the normal rat brain. Magn Reson Med, 4(4), 351–365. https://doi.org/10.1002/mrm.1910040406Full Text Link to Item
-
Sherrier, R. H., Chiles, C., Johnson, G. A., & Ravin, C. E. (1987). Differentiation of benign from malignant pulmonary nodules with digitized chest radiographs. Radiology, 162(3), 645–649. https://doi.org/10.1148/radiology.162.3.3809476Full Text Link to Item
-
Utz, J. A., Herfkens, R. J., Johnson, C. D., Shimakawa, A., Pelc, N., Glover, G., … Spritzer, C. E. (1987). Two-second MR images: comparison with spin-echo images in 29 patients. Ajr Am J Roentgenol, 148(3), 629–633. https://doi.org/10.2214/ajr.148.3.629Full Text Link to Item
-
Stude, R. A., Hedlund, L. W., Johnson, G. A., & Thompson, W. M. (1987). Contrast enhancement of the liver. Evaluation by automated contiguous pixel search. Invest Radiol, 22(2), 132–136. https://doi.org/10.1097/00004424-198702000-00008Full Text Link to Item
-
Brown, J. M., Fonteno, W. C., Cassel, D. K., & Johnson, G. A. (1987). COMPUTED TOMOGRAPHIC ANALYSES OF WATER DISTRIBUTION IN THREE POROUS FOAM MEDIA. Soil Science Society of America Journal, 51(5), 1121–1125. https://doi.org/10.2136/sssaj1987.03615995005100050005xFull Text
-
Fram, E. K., Herfkens, R. J., Johnson, G. A., Glover, G. H., Karis, J. P., Shimakawa, A., … Pelc, N. J. (1987). Rapid calculation of T1 using variable flip angle gradient refocused imaging. Magn Reson Imaging, 5(3), 201–208. https://doi.org/10.1016/0730-725x(87)90021-xFull Text Link to Item
-
Karis, J. P., Allan Johnson, G., & Glover, G. H. (1987). Signal-to-noise improvements in three-dimensional NMR microscopy using limited-angle excitation. Journal of Magnetic Resonance (1969), 71(1), 24–33. https://doi.org/10.1016/0022-2364(87)90124-7Full Text
-
MacFall, J. R., Wehrli, F. W., Breger, R. K., & Johnson, G. A. (1987). Methodology for the measurement and analysis of relaxation times in proton imaging. Magn Reson Imaging, 5(3), 209–220. https://doi.org/10.1016/0730-725x(87)90022-1Full Text Link to Item
-
McAdams, H. P., Johnson, G. A., Suddarth, S. A., Sherrier, R. H., & Ravin, C. E. (1987). IMPLEMENTATION OF ADAPTIVE FILTRATION FOR DIGITAL CHEST IMAGING. Optical Engineering, 26(7), 669–674. https://doi.org/10.1117/12.7974133Full Text
-
Sherrier, R. H., & Johnson, G. A. (1987). Regionally adaptive histogram equalization of the chest. Ieee Trans Med Imaging, 6(1), 1–7. https://doi.org/10.1109/TMI.1987.4307791Full Text Link to Item
-
Sherrier, R. H., & Johnson, G. A. (1987). REGIONALLY ADAPTIVE HISTOGRAM EQUALIZATION OF THE CHEST. Ieee Transactions on Medical Imaging, MI–6(1), 1–7.
-
Suddarth, S. A., Johnson, G. A., Sherrier, R. H., & Ravin, C. E. (1987). Performance of high-resolution monitors for digital chest imaging. Med Phys, 14(2), 253–257. https://doi.org/10.1118/1.596079Full Text Link to Item
-
Brown, J. M., Johnson, G. A., & Kramer, P. J. (1986). In Vivo Magnetic Resonance Microscopy of Changing Water Content in Pelargonium hortorum Roots. Plant Physiol, 82(4), 1158–1160. https://doi.org/10.1104/pp.82.4.1158Full Text Link to Item
-
Hedlund, L. W., Johnson, G. A., & Mills, G. I. (1986). Magnetic resonance microscopy of the rat thorax and abdomen. Invest Radiol, 21(11), 843–846. https://doi.org/10.1097/00004424-198611000-00002Full Text Link to Item
-
Bone, S. N., Johnson, G. A., & Thompson, M. B. (1986). Three-dimensional magnetic resonance microscopy of the developing chick embryo. Invest Radiol, 21(10), 782–787. https://doi.org/10.1097/00004424-198610000-00003Full Text Link to Item
-
JOHNSON, G. A., BAILEY, J. E., BRUCK, R. I., & MATYAC, C. A. (1986). STUDIES OF DISEASED ROOT-TISSUE USING NUCLEAR-MAGNETIC-RESONANCE IMAGING. Phytopathology, 76(10), 1067–1067.Link to Item
-
BONE, S. N., JOHNSON, G. A., & THOMPSON, M. B. (1986). MRI MICROSCOPY OF THE DEVELOPING CHICK-EMBRYO. Investigative Radiology, 21(9), S34–S34.Link to Item
-
JOHNSON, G. A., THOMPSON, M. B., & DRAYER, B. P. (1986). 3-DIMENSIONAL MRI MICROSCOPY OF THE RAT-BRAIN. Investigative Radiology, 21(9), S25–S25.Link to Item
-
KARIS, J. P., GLOVER, G. H., & JOHNSON, G. A. (1986). VARIANT ANGLE GRADIENT REFOCUSING IN 3-DIMENSIONAL MRI MICROSCOPY. Investigative Radiology, 21(9), S34–S34.Link to Item
-
Hedlund, L., & Johnson, G. A. (1986). 53 MAGNETIC RESONANCE IMAGING OF THE RAT THORAX AND ABDOMEN. Investigative Radiology, 21(9), S14–S14. https://doi.org/10.1097/00004424-198609000-00071Full Text
-
Drayer, B., Burger, P., Darwin, R., Riederer, S., Herfkens, R., & Johnson, G. A. (1986). MRI of brain iron. Ajr Am J Roentgenol, 147(1), 103–110. https://doi.org/10.2214/ajr.147.1.103Full Text Link to Item
-
DRAYER, B., BURGER, P., CAIN, J., LEONG, J., JOHNSON, G. A., HEINZ, E. R., … HERFKENS, R. (1986). MR IMAGING AND PERLS STAIN OF BASAL GANGLIA IRON WITH NORMAL AGING. American Journal of Neuroradiology, 7(3), 554–555.Link to Item
-
DRAYER, B., BURGER, P., DARWIN, R., RIEDERER, S., HERFKENS, R., & JOHNSON, G. A. (1986). MAGNETIC-RESONANCE-IMAGING OF BRAIN IRON. American Journal of Neuroradiology, 7(3), 373–380.Link to Item
-
Drayer, B. P., Olanow, W., Burger, P., Johnson, G. A., Herfkens, R., & Riederer, S. (1986). Parkinson plus syndrome: diagnosis using high field MR imaging of brain iron. Radiology, 159(2), 493–498. https://doi.org/10.1148/radiology.159.2.3961182Full Text Link to Item
-
McAdams, H. P., Johnson, G. A., Suddarth, S. A., & Ravin, C. E. (1986). Histogram-directed processing of digital chest images. Invest Radiol, 21(3), 253–259. https://doi.org/10.1097/00004424-198603000-00011Full Text Link to Item
-
Johnson, G. A., Thompson, M. B., Drayer, B. P., & Bone, S. N. (1986). Magnetic resonance microscopy in neurologic models. Acta Radiol Suppl, 369, 267–268.Link to Item
-
Hedlund, L. W., Johnson, G. A., Karis, J. P., & Effmann, E. L. (1986). MR "microscopy" of the rat thorax. J Comput Assist Tomogr, 10(6), 948–952. https://doi.org/10.1097/00004728-198611000-00010Full Text Link to Item
-
Johnson, G. A., Thompson, M. B., Gewalt, S. L., & Hayes, C. E. (1986). Nuclear magnetic resonance imaging at microscopic resolution. Journal of Magnetic Resonance (1969), 68(1), 129–137.
-
Sherrier, R. H., Johnson, G. A., Suddarth, S. A., Chiles, C., Hulka, C., & Ravin, C. E. (1985). Digital synthesis of lung nodules. Invest Radiol, 20(9), 933–937. https://doi.org/10.1097/00004424-198512000-00008Full Text Link to Item
-
Blinder, R. A., Herfkens, R. J., Johnson, G. A., & Coleman, R. E. (1985). 121 SURFACE COIL MOTION ARTIFACTS IN MR IMAGING. Investigative Radiology, 20(6), S31–S31. https://doi.org/10.1097/00004424-198509000-00149Full Text
-
Johnson, G. A., Herfkens, R. J., & Brown, M. A. (1985). Tissue relaxation time: in vivo field dependence. Radiology, 156(3), 805–810. https://doi.org/10.1148/radiology.156.3.2991980Full Text Link to Item
-
MCADAMS, H. P., JOHNSON, G. A., SUDDARTH, S. A., & RAVIN, C. E. (1985). 71 HISTOGRAM DIRECTED PROCESSING OF DIGITAL CHEST IMAGES. Investigative Radiology, 20(6), S18–S18. https://doi.org/10.1097/00004424-198509000-00099Full Text
-
McAdams, H. P., Johnson, G. A., Suddarth, S. A., & Ravin, C. E. (1985). 105 Optimization of Adaptive Filtration for Digital Chest Imaging. Investigative Radiology, 20(6), S27–S27. https://doi.org/10.1097/00004424-198509000-00133Full Text
-
Johnson, G. A., Danieley, N., & Ravin, C. E. (1985). Processing alternatives for digital chest imaging. Radiol Clin North Am, 23(2), 335–340.Link to Item
-
Herfkens, R. J., & Johnson, G. A. (1985). Magnetic resonance imaging at high-strength magnetic fields. Magn Reson Annu, 197–215.Link to Item
-
SHERRIER, R. H., CHILES, C., SUDDARTH, S. A., JOHNSON, G. A., & RAVIN, C. E. (1985). EVALUATION OF COMPUTER SYNTHESIZED PULMONARY NODULES. Investigative Radiology, 20(6), S27–S27.Link to Item
-
SHERRIER, R. H., SUDDARTH, S. A., JOHNSON, G. A., & RAVIN, C. E. (1985). AUTOMATED OBSERVER STUDIES ON A DIGITAL CHEST SYSTEM. Investigative Radiology, 20(6), S18–S18.Link to Item
-
WINTER, T. C., JOHNSON, G. A., & MACFALL, J. R. (1985). PRECISION AND ACCURACY IN THE MEASUREMENT OF T1 ON AN IMAGING-SYSTEM. Investigative Radiology, 20(6), S14–S14.Link to Item
-
BLINDER, R. A., HERFKENS, R. J., COLEMAN, R. E., JOHNSON, G. A., SCHENCK, J. F., HART, H. R., … EDELSTEIN, W. A. (1985). HIGH-RESOLUTION MRI IMAGING AT 1.5T USING SURFACE COILS. Journal of Nuclear Medicine, 26(5), P8–P8.Link to Item
-
Sostman, H. D., Gore, J. C., Flye, M. W., Johnson, G. A., & Herfkens, R. J. (1985). Time course and mechanism of alterations in proton relaxation during liver regeneration in the rat. Hepatology, 5(4), 538–543. https://doi.org/10.1002/hep.1840050403Full Text Link to Item
-
Godwin, J. D., Pelc, N. J., Johnson, G. A., Fram, E. K., & C, R. (1984). 106. PROGRESS IN ECG-GATED CT. Investigative Radiology, 19(5), S27–S27. https://doi.org/10.1097/00004424-198409000-00131Full Text
-
Herfkens, R. J., Johnson, G. A., & Glover, G. (1984). 166. IN VIVO CHEMICAL SHIFT IMAGING OF HYDROGEN. Investigative Radiology, 19(5), S42–S42. https://doi.org/10.1097/00004424-198409000-00191Full Text
-
Johnson, G. A., Herfkens, R. J., & MacFall, J. R. (1984). 129. IN VIVO FIELD DEPENDENCE OF TISSUE RELAXATION TIMES. Investigative Radiology, 19(5), S33–S33. https://doi.org/10.1097/00004424-198409000-00154Full Text
-
Sherrier, R. H., Johnson, G. A., Ravin, C. E., & Suddarth, S. A. (1984). 194. DIGITAL SYNTHESIS OF LUNG NODULES. Investigative Radiology, 19(5), S49–S49. https://doi.org/10.1097/00004424-198409000-00219Full Text
-
Stude, R., Hedlund, L., Johnson, G. A., & Thompson, W. M. (1984). 159. A CT EVALUATION OF THREE HEPATOBILIARY CONTRAST AGENTS. Investigative Radiology, 19(5), S40–S40. https://doi.org/10.1097/00004424-198409000-00184Full Text
-
HAYES, C. E., JOHNSON, G. A., & HERFKENS, R. J. (1984). DESIGN CONSIDERATIONS FOR SMALL ANIMAL IMAGING IN A LARGE BORE MRI SYSTEM. Investigative Radiology, 19(5), S25–S25.Link to Item
-
HEINZ, E. R., HERFKINS, R., JOHNSON, G. A., & DRAYER, B. P. (1984). CAROTID-ARTERY IMAGING BY A 1.5-T MR SYSTEM. American Journal of Neuroradiology, 5(5), 670–670.Link to Item
-
BROWN, M. A., & JOHNSON, G. A. (1984). VARIABLE FIELD STUDIES OF POTENTIAL PARAMAGNETIC NMR CONTRAST AGENTS. Magnetic Resonance in Medicine, 1(2), 119–120.Link to Item
-
Brown, M. A., & Johnson, G. A. (1984). Transition metal-chelate complexes as relaxation modifiers in nuclear magnetic resonance. Med Phys, 11(1), 67–72. https://doi.org/10.1118/1.595455Full Text Link to Item
-
DRAYER, B. P., HERFKENS, R. J., JOHNSON, G. A., HEINZ, E. R., & YEATES, A. E. (1984). HIGH-FIELD NMR IMAGING (1.5T) IN A HOSPITAL ENVIRONMENT. American Journal of Neuroradiology, 5(5), 669–669.Link to Item
-
Godwin, J. D., Johnson, G. A., & Fram, E. K. (1984). A phantom for testing ECG-gated computed tomography of the heart. Invest Radiol, 19(4), 279–283. https://doi.org/10.1097/00004424-198407000-00008Full Text Link to Item
-
Johnson, G. A., Suddarth, S., & Dunnick, N. R. (1983). A system for digital videodensitometry. Proceedings of Spie the International Society for Optical Engineering, 419, 222–227. https://doi.org/10.1117/12.936029Full Text
-
Johnson, G. A., & Ravin, C. E. (1983). A survey of digital chest radiography. Radiol Clin North Am, 21(4), 655–664.Link to Item
-
Thompson, W. M., Stude, R., Bates, M., Hedlund, L., & Johnson, G. A. (1983). CONTRAST ENHANCEMENT OF THE LIVER DURING CT. Investigative Radiology, 18(4), S11–S11. https://doi.org/10.1097/00004424-198307000-00064Full Text
-
Silverman, P. M., Johnson, G. A., & Korobkin, M. (1983). High-resolution sagittal and coronal reformatted CT images of the larynx. Ajr Am J Roentgenol, 140(4), 819–822. https://doi.org/10.2214/ajr.140.4.819Full Text Link to Item
-
Thompson, W. M., Halvorsen, R. A., Gedgaudas, R. K., Kelvin, F. M., Rice, R. P., Woodfield, S., … Jorgensen, D. B. (1983). High kVp vs. low kVp for T-tube and operative cholangiography. Radiology, 146(3), 635–642. https://doi.org/10.1148/radiology.146.3.6828675Full Text Link to Item
-
Godwin, J. D., Johnson, G. A., & Fram, E. K. (1983). Testing electrocardiographically-gated ct of the heart with a motion phantom. Investigative Radiology, 18(4), S33–S33.
-
Ravin, C. E., & Johnson, G. A. (1983). The 'optimal' chest radiograph. Seminars in Respiratory Medicine, 5(1), 1–14. https://doi.org/10.1055/s-2007-1011430Full Text
-
JOHNSON, G. A., DANIELEY, N., SUDDARTH, S., & DUNNICK, N. R. (1983). A SYSTEM FOR DIGITAL VIDEODENSITOMETRY. American Journal of Roentgenology, 141(6), 1360–1361.Link to Item
-
Johnson, G. A. (1982). Practical approach to quality assurance in computed tomography. Proceedings of Spie the International Society for Optical Engineering, 347, 148–154. https://doi.org/10.1117/12.933821Full Text
-
Silverman, P. M., Korobkin, M., Thompson, W. M., Johnson, G. A., Cole, T. B., & Fisher, S. R. (1982). Work in progress: high-resolution, thin-section computed tomography of the larynx. Radiology, 145(3), 723–725. https://doi.org/10.1148/radiology.145.3.7146403Full Text Link to Item
-
Johnson, G. A., Godwin, J. D., & Fram, E. K. (1982). Gated multiplanar cardiac computed tomography. Radiology, 145(1), 195–197. https://doi.org/10.1148/radiology.145.1.7122877Full Text Link to Item
-
Johnson, G. A., & Korobkin, M. (1982). Image techniques for multiplanar computed tomography. Radiology, 144(4), 829–834. https://doi.org/10.1148/radiology.144.4.7111733Full Text Link to Item
-
Godwin, J. D., Speckman, J. M., Fram, E. K., Johnson, G. A., Putman, C. E., Korobkin, M., & Breiman, R. S. (1982). Distinguishing benign from malignant pulmonary nodules by computed tomography. Radiology, 144(2), 349–351. https://doi.org/10.1148/radiology.144.2.7089288Full Text Link to Item
-
Halvorsen, R. A., Woodfield, S., Hedlund, L., Johnson, G. A., & Thompson, W. M. (1982). CONTRAST ENHANCEMENT OF THE HEPATOBILIARY SYSTEM DURING CT. Investigative Radiology, 17(4), S27–S27. https://doi.org/10.1097/00004424-198207000-00134Full Text
-
Silverman, P. M., Johnson, G. A., Korobkin, M., & Thompson, W. M. (1982). HIGH RESOLUTION MULTIPLANAR CT IMAGES OF THE LARYNX. Investigative Radiology, 17(4), S34–S34. https://doi.org/10.1097/00004424-198207000-00161Full Text
-
Ford, K. K., Heinz, E. R., Johnson, G. A., Drayer, B. D., & Dubois, P. J. (1982). Low-cost digital subtraction angiography. Ajnr Am J Neuroradiol, 3(4), 448–451.Link to Item
-
Ford, K. K., Heinz, E. R., Johnson, G. A., Drayer, B. P., & Dubois, P. J. (1982). Low-cost digital subtraction. American Journal of Neuroradiology, 3(1), 99–99.
-
JOHNSON, G. A. (1982). A PRACTICAL APPROACH TO QUALITY ASSURANCE IN CT. American Journal of Roentgenology, 139(2), 427–427.Link to Item
-
Silverman, P. M., Johnson, G. A., Korobkin, M., & Thompson, W. M. (1982). High-resolution multiplanar CT images of the larynx. Invest Radiol, 17(6), 634–637. https://doi.org/10.1097/00004424-198211000-00019Full Text Link to Item
-
Halvorsen, R. A., Woodfield, S., T., R., Allen, S. M., Hedlung, L. W., Johnson, G. A., & Thompson, W. M. (1981). AN EVALUATION OF CONTRAST AGENTS FOR CT OF THE HEPATOBILIARY SYSTEM. Investigative Radiology, 16(5), 387–387. https://doi.org/10.1097/00004424-198109000-00053Full Text
-
Johnson, G. A., Nelson, C. E., & OʼFoghludha, F. (1981). IMAGING LIMITS IN DIGITAL RADIOGRAPHY. Investigative Radiology, 16(5), 377–377. https://doi.org/10.1097/00004424-198109000-00033Full Text
-
KOROBKIN, M., JOHNSON, G. A., & BREIMAN, R. S. (1981). METHODOLOGIC CONSIDERATIONS IN MULTIPLANAR REFORMATTING OF TRANSAXIAL CT IMAGES. Investigative Radiology, 16(5), 374–374. https://doi.org/10.1097/00004424-198109000-00027Full Text
-
Nelson, C. E., Johnson, G. A., & Bentel, G. (1981). MULTI-PLANAR RECONSTRUCTION–APPLICATIONS IN RADIATION ONCOLOGY TREATMENT PLANNING. Investigative Radiology, 16(5), 417–417. https://doi.org/10.1097/00004424-198109000-00113Full Text
-
Johnson, G. A., Korobkin, M., & Heinz, E. R. (1981). Evaluation of multiplanar imaging capabilities of four current computed tomography (CT) scanners. Proceedings of Spie the International Society for Optical Engineering, 273, 318–325. https://doi.org/10.1117/12.931819Full Text
-
Johnson, G. A., Ford, K., & Heinz, R. (1981). Digital radiography using the quantex ds-20. Proceedings of Spie the International Society for Optical Engineering, 273, 114–119. https://doi.org/10.1117/12.931792Full Text
-
O’Foghludha, F., & Johnson, G. A. (1981). Voltage waveform effects on output and penetration of W- and Mo-anode mammographic tubes. Phys Med Biol, 26(2), 291–303. https://doi.org/10.1088/0031-9155/26/2/008Full Text Link to Item
-
Johnson, G. A., & Ravin, C. E. (1981). Effect of vertical cassette holder design and construction on scatter-to-primary radiation ratios. Radiology, 138(2), 461–464. https://doi.org/10.1148/radiology.138.2.7455131Full Text Link to Item
-
Hedlund, L. W., Jones, D. P., Effmann, E. L., Johnson, G. A., Bates, W. M., Beck, J. W., … Putman, C. E. (1981). A computed tomographic study of the dog lung during hemorrhagic shock and after resuscitation. Invest Radiol, 16(6), 466–472. https://doi.org/10.1097/00004424-198111000-00003Full Text Link to Item
-
JOHNSON, G. A., FORD, K. K., & HEINZ, R. (1981). DIGITAL RADIOGRAPHY USING THE QUANTEX DS-20. American Journal of Roentgenology, 136(6), 1274–1274.Link to Item
-
JOHNSON, G. A., KOROBKIN, M., & HEINZ, R. (1981). AN EVALUATION OF MULTIPLANAR IMAGING CAPABILITIES OF 4 CURRENT CT SCANNERS. American Journal of Roentgenology, 136(6), 1279–1279.Link to Item
-
Wolbarsht, M. L., O’foghludha, F. A., Sliney, D. H., Guy, A. W., Smith, A. A., & Johnson, G. A. (1980). Electromagnetic emission from visual display units: A non-hazard. Proceedings of Spie the International Society for Optical Engineering, 229, 187–195. https://doi.org/10.1117/12.958802Full Text
-
JOHNSON, G. A., & RAVIN, C. E. (1980). SCATTERED RADIATION FROM THE FILM HOLDER IN CHEST RADIOGRAPHY. American Journal of Roentgenology, 134(1), 201–201.Link to Item
-
THOMPSON, W. M., AMBERG, J. R., LOWTHER, D. T., SHAW, M., BATES, M., & JOHNSON, G. A. (1980). GALLBLADDER DENSITY AND IODINE CONCENTRATION IN HUMANS DURING ORAL CHOLECYSTOGRAPHY - A COMPARISON OF IOPANOIC ACID AND IOPRONIC ACID. Gastrointestinal Radiology, 5(1), 83–83.Link to Item
-
Thompson, W. M., Amberg, J. R., & Shaw, M. (1980). Iodine concentration and radiographic density during oral cholecystography. Investigative Radiology, 15(5), 397. https://doi.org/10.1097/00004424-198009000-00049Full Text
-
JOHNSON, G. A., & FOGHLUDA, F. (1980). AN INVESTIGATION OF TRANSMOLYBDENUM FLUORESCENT ANODES FOR MAMMOGRAPHY. American Journal of Roentgenology, 134(4), 855–855.Link to Item
-
JOHNSON, G. A., HOLT, D. C., & EFFMANN, E. L. (1980). PRACTICAL GUIDELINES FOR SPECIMEN RADIOGRAPHY. Investigative Radiology, 15(5), 377–377.Link to Item
-
Johnson, G. A., & O’Foghludha, F. (1980). Simulation of mammographic x-ray spectra. Med Phys, 7(3), 189–195. https://doi.org/10.1118/1.594684Full Text Link to Item
-
HEDLUND, L., JONES, D., EFFMANN, E., JOHNSON, G. A., BATES, W., WOLFE, W., & PUTMAN, C. (1979). COMPUTERIZED TOMOGRAPHIC STUDY OF THE DOG LUNG DURING HEMORRHAGIC-SHOCK. Investigative Radiology, 14(5), 369–369.Link to Item
-
Johnson, G. A., & O’Foghludha, F. (1978). An experimental "trans-molybdenum" tube for mammography. Radiology, 127(2), 511–516. https://doi.org/10.1148/127.2.511Full Text Link to Item
-
Johnson, G. A., Manson, E. L., & O’Foghludha, F. (1978). Simple method of obtaining Si(Li) detector efficiency. Nuclear Instruments and Methods, 151(1–2), 217–220. https://doi.org/10.1016/0029-554X(78)90491-3Full Text
-
JOHNSON, G. A., & OFOGHLUDHA, F. (1977). SPECTROMETRIC STUDIES OF WAVEFORM AND FILTRATION EFFECTS IN MAMMOGRAPHY. Physics in Medicine and Biology, 22(3), 593–593.Link to Item
-
Johnson, G. A. (1975). Free radicals formed by exposure of pyrimidine solids to sodium atoms: an electron spin resonance study. Proc Natl Acad Sci U S A, 72(3), 974–978. https://doi.org/10.1073/pnas.72.3.974Full Text Link to Item
-
-
Book Sections
-
Spiliopoulos, D., Kagadis, G. C., Karnabatidis, D., Johnson, G. A., & Badea, C. T. (2016). Digital Subtracted Angiography of Small Animals (Accepted). In G. C. Kagadis, N. L. Ford, G. K. Loudos, & D. Karnabatidis (Eds.), Handbook of Small Animal Imaging: Preclinical Imaging, Therapy, and Applications (pp. 67–75). Taylor & Francis Books, Inc., CRC Press.
-
Zhou, X., & Johnson, G. A. (2012). Magnetic resonance microscopy. In Medical Imaging: Principles and Practices (pp. 5-42-6–14). https://doi.org/10.1201/b12939Full Text
-
Zhou, X., & Johnson, G. A. (2006). Magnetic resonance microscopy. In Medical Devices and Systems (pp. 15-1-15–14).
-
Zhou, X., & Allan Johnson, G. (2003). Magnetic resonance microscopy. In Biomedical Imaging (pp. 13-1-13–14).
-
-
Conference Papers
-
Johnson, G. A., Anderson, R. J., Cook, J. J., Long, C., & Badea, A. (2016). Image-processing pipelines: Applications in magnetic resonance histology. In Progress in Biomedical Optics and Imaging Proceedings of Spie (Vol. 9784). https://doi.org/10.1117/12.2203525Full Text
-
MacFall, J. S., & Johnson, G. A. (2015). Use of magnetic resonance imaging in the study of plants and soils (Vol. 36, pp. 99–113). https://doi.org/10.2136/sssaspecpub36.c9Full Text
-
Calabrese, E., Hickey, P., Hulette, C., Zhang, J., Parente, B., Lad, S. P., & Johnson, G. A. (2015). Postmortem Diffusion MRI of the Human Brainstem and Thalamus for Deep Brain Stimulator Electrode Localization. In Movement Disorders (Vol. 30, pp. E6–E6). Ft Myers, FL: WILEY-BLACKWELL.Link to Item
-
Johnson, G. A., Badea, A., Calabrese, E., Liu, C., & Xie, L. (2014). Magnetic resonance histology—Applications in toxicology. In Toxicology Letters (Vol. 229, pp. S31–S32). Elsevier BV. https://doi.org/10.1016/j.toxlet.2014.06.148Full Text
-
Johnston, S. M., Johnson, G. A., & Badea, C. T. (2014). Helical dual source cone-beam micro-CT. In 2014 Ieee 11th International Symposium on Biomedical Imaging, Isbi 2014 (pp. 177–180). https://doi.org/10.1109/isbi.2014.6867838Full Text
-
Badea, C. T., Befera, N., Clark, D., Qi, Y., & Johnson, G. A. (2014). Dual-energy micro-CT imaging of pulmonary airway obstruction: Correlation with micro-SPECT. In Progress in Biomedical Optics and Imaging Proceedings of Spie (Vol. 9038). https://doi.org/10.1117/12.2043094Full Text
-
Clark, D. P., Johnson, G. A., & Badea, C. T. (2014). A multi-resolution approach to retrospectively-gated cardiac micro-CT reconstruction. In Progress in Biomedical Optics and Imaging Proceedings of Spie (Vol. 9033). https://doi.org/10.1117/12.2043044Full Text
-
Clark, D. P., Johnson, G. A., & Badea, C. T. (2014). Robust material decomposition for spectral CT. In Progress in Biomedical Optics and Imaging Proceedings of Spie (Vol. 9038). https://doi.org/10.1117/12.2042546Full Text
-
Clark, D., Johnston, S. M., Johnson, G. A., & Badea, C. T. (2013). The effect of scatter correction on dual energy micro-CT. In Progress in Biomedical Optics and Imaging Proceedings of Spie (Vol. 8668). https://doi.org/10.1117/12.2006904Full Text
-
Guo, X., Johnston, S. M., Johnson, G. A., & Badea, C. T. (2012). A comparison of sampling strategies for dual energy micro-CT. In Progress in Biomedical Optics and Imaging Proceedings of Spie (Vol. 8313). https://doi.org/10.1117/12.911548Full Text
-
Clark, D., Johnson, G. A., & Badea, C. T. (2012). Denoising of 4D Cardiac Micro-CT Data Using Median-Centric Bilateral Filtration. In Proc Spie Int Soc Opt Eng (Vol. 8314). United States. https://doi.org/10.1117/12.911478Full Text Link to Item
-
Badea, C. T., Stanton, I. N., Johnston, S. M., Johnson, G. A., & Therien, M. J. (2012). Investigations on X-ray luminescence CT for small animal imaging. In Proc Spie Int Soc Opt Eng (Vol. 8313, p. 83130T). United States. https://doi.org/10.1117/12.911465Full Text Link to Item
-
Parnell, S. E., Holloway, H. T., Paniagua, B., Oguz, I., Styner, M. A., Johnson, G. A., & Sulik, K. K. (2012). EFFECTS OF CHRONIC EARLY GESTATIONAL ETHANOL EXPOSURE ON THE DEVELOPING BRAIN: A MAGNETIC RESONANCE MICROSCOPY STUDY. In Alcoholism Clinical and Experimental Research (Vol. 36, pp. 279A-279A).Link to Item
-
Badea, C. T., Johnston, S. M., Qi, Y., Ghaghada, K., & Johnson, G. A. (2011). Dual-energy micro-CT imaging for differentiation of iodine- and gold-based nanoparticles. In Progress in Biomedical Optics and Imaging Proceedings of Spie (Vol. 7961). https://doi.org/10.1117/12.878043Full Text
-
Sulik, K. K., O’Leary-Moore, S. K., Parnell, S. E., Lipinski, R. J., Pecevich, S., Holloway, H. T., … Johnson, G. A. (2011). Magnetic resonance and diffusion tensor imaging of pre- and postnatal brains in a mouse Fetal Alcohol Spectrum Disorders model. In Alcohol (Vol. 45, pp. 282–282). Volterra, ITALY: ELSEVIER SCIENCE INC.Link to Item
-
Lipinski, R. J., Hammond, P., Ament, J. J., Pecevich, S. J., Jiang, Y., Dehart, D. B., … Sulik, K. K. (2011). MAGNETIC RESONANCE MICROSCOPY-BASED 3D FACE-BRAIN CORRELATIONS IN AN FASD MOUSE MODEL. In Alcoholism Clinical and Experimental Research (Vol. 35, pp. 266A-266A).Link to Item
-
Constantinides, C., Aristokleous, N., Johnson, G. A., & Perperides, D. (2010). Static and dynamic cardiac modelling: Initial strides and results towards a quantitatively accurate mechanical heart model. In 2010 7th Ieee International Symposium on Biomedical Imaging: From Nano to Macro, Isbi 2010 Proceedings (pp. 496–499). https://doi.org/10.1109/ISBI.2010.5490300Full Text
-
O’Leary-Moore, S. K., Parnell, S. E., Godin, E. A., Johnson, G. A., Styner, M., Oguz, I., … Sulik, K. K. (2010). MAGNETIC RESONANCE MICROSCOPY AND DIFFUSION TENSOR IMAGING DEFINE STAGE-DEPENDENT CHANGES IN BRAIN MORPHOLOGY AFTER PRENATAL ETHANOL EXPOSURE IN MICE. In Alcoholism Clinical and Experimental Research (Vol. 34, pp. 298A-298A). San Antonio, TX: WILEY-BLACKWELL.Link to Item
-
Johnston, S. M., Johnson, G. A., & Badea, C. T. (2010). GPU-based iterative reconstruction with total variation minimization for micro-CT. In Progress in Biomedical Optics and Imaging Proceedings of Spie (Vol. 7622). https://doi.org/10.1117/12.844368Full Text
-
Sulik, K. K., O’Leary-Moore, S. K., Parnell, S. E., Godin, E. A., Styner, M. A., Lipinski, R. J., & Johnson, G. A. (2010). MAGNETIC RESONANCE IMAGING-BASED ANALYSES OF A FETAL ALCOHOL SPECTRUM DISORDERS MOUSE MODEL. In Alcoholism Clinical and Experimental Research (Vol. 34, pp. 31A-31A).Link to Item
-
Zhang, X., Badea, C. T., Hood, G., Wetzel, A. W., Stiles, J. R., & Johnson, G. A. (2010). Free-space fluorescence tomography with adaptive sampling based on anatomical information from microCT. In Proc Spie Int Soc Opt Eng (Vol. 7757). United States. https://doi.org/10.1117/12.841891Full Text Link to Item
-
Perez, B. A., Ghafoori, A. P., Johnston, S. M., Jeffords, L. B., Kim, Y., Badea, C. T., … Kirsch, D. G. (2009). Dissecting the Mechanism of Tumor Response to Radiation Therapy with Primary Lung Cancers in Mice. In International Journal of Radiation Oncology*Biology*Physics (Vol. 75, pp. S537–S537). Elsevier BV. https://doi.org/10.1016/j.ijrobp.2009.07.1227Full Text
-
Badea, C. T., Johnston, S. M., Lin, M., Hedlund, L. W., & Johnson, G. A. (2009). 4D micro-CT-based perfusion imaging in small animals. In Progress in Biomedical Optics and Imaging Proceedings of Spie (Vol. 7258). https://doi.org/10.1117/12.811213Full Text
-
Johnston, S. M., Johnson, G. A., & Badea, C. T. (2009). A material decomposition method for dual energy micro-CT. In Progress in Biomedical Optics and Imaging Proceedings of Spie (Vol. 7258). https://doi.org/10.1117/12.811673Full Text
-
Zhang, X., Badea, C., Jacob, M., & Johnson, G. A. (2009). Development of a noncontact 3-D fluorescence tomography system for small animal in vivo imaging. In Proc Spie Int Soc Opt Eng (Vol. 7191, p. nihpa106691). United States. https://doi.org/10.1117/12.808199Full Text Link to Item
-
O’Leary-Moore, S. K., Godin, E. A., Parnell, S. E., Dehart, D. B., Ament, J. J., Johnson, G. A., … Sulik, K. K. (2009). EFFECTS OF ACUTE GESTATIONAL DAY 10 ETHANOL EXPOSURE ON THE DEVELOPING MOUSE BRAIN: A HIGH-RESOLUTION MAGNETIC RESONANCE MICROSCOPY STUDY. In Alcoholism Clinical and Experimental Research (Vol. 33, pp. 132A-132A).Link to Item
-
Badea, C. T., Johnston, S., Johnson, B., Lin, M., Hedlund, L. W., & Johnson, G. A. (2008). A dual micro-CT system for small animal imaging. In Proc Spie Int Soc Opt Eng (Vol. 6913, p. 691342). United States. https://doi.org/10.1117/12.772303Full Text Link to Item
-
Bug, W., Wong, W. W., Gustafson, C., Johnson, G. A., Martone, M. E., Price, D. L., … Nissanov, J. (2007). Brain atlasing tool interoperation: NeuroTerrain-Smart Atlas synergistic visualization and analysis environment. In Proceedings of the 3rd International Ieee Embs Conference on Neural Engineering (pp. 280–283). https://doi.org/10.1109/CNE.2007.369665Full Text
-
Wetzel, A. W., Badea, C. T., Pomerantz, S. M., Mistry, N., Nave, D., & Johnson, G. A. (2007). Measurement and modeling of 4D live mouse heart volumes from CT time series. In Proceedings of Spie the International Society for Optical Engineering (Vol. 6491). https://doi.org/10.1117/12.704792Full Text
-
De Lin, M., Hedlund, L., & Johnson, G. A. (2006). Micro radiography imaging of the rodent with phenylephrine induced vascular hypertension. In 2006 3rd Ieee International Symposium on Biomedical Imaging: From Nano to Macro Proceedings (Vol. 2006, pp. 610–613).
-
Mistry, N., De Lin, M., Hedlund, L., & Johnson, G. A. (2006). Multimodality imaging of pulmonary function in the rodent. In 2006 3rd Ieee International Symposium on Biomedical Imaging: From Nano to Macro Proceedings (Vol. 2006, pp. 920–923).
-
Badea, C. T., Hedlund, L. W., Lin, M. D., Boslego, J. F., & Johnson, G. A. (2006). Functional imaging in small animals using tomographic digital subtraction angiography. In 2006 3rd Ieee International Symposium on Biomedical Imaging: From Nano to Macro Proceedings (Vol. 2006, pp. 1208–1211).
-
Cody, D., Stickel, J., Johnson, G., & Boone, J. (2006). MO‐D‐330D‐01: Molecular Imaging I: The Physics of Molecular Imaging. In Medical Physics (Vol. 33, p. 2160). https://doi.org/10.1118/1.2241412Full Text
-
Hedlund, L. W., & Johnson, G. A. (2005). Morphology of the small-animal lung using magnetic resonance microscopy. In Proc Am Thorac Soc (Vol. 2, pp. 481–502). United States. https://doi.org/10.1513/pats.200507-074DSFull Text Link to Item
-
Bowsher, J. E., Yuan, H., Hedlund, L. W., Turkington, T. G., Akabani, G., Badea, A., … Allan Johnson, G. (2004). Utilizing MRI information to estimate F18-FDG distributions in rat flank tumors. In Ieee Nuclear Science Symposium Conference Record (Vol. 4, pp. 2488–2492).
-
Badea, C. T., Hedlund, L. W., Wheeler, C. T., Mai, W., & Johnson, G. A. (2004). Volumetric micro-CT system for in vivo microscopy. In 2004 2nd Ieee International Symposium on Biomedical Imaging: Macro to Nano (Vol. 2, pp. 1377–1380).
-
De Lin, M., Badea, C. T., & Johnson, G. A. (2004). Optimized radiographic spectra for digital subtraction angiography in the mouse. In 2004 2nd Ieee International Symposium on Biomedical Imaging: Macro to Nano (Vol. 2, pp. 1412–1415).
-
Mai, W., Badea, C. T., Wheeler, C. T., Hedlund, L. W., & Johnson, G. A. (2004). Effects of breathing motion on the spatial resolution in microscopic imaging techniques of rodents. In 2004 2nd Ieee International Symposium on Biomedical Imaging: Macro to Nano (Vol. 1, pp. 472–475).
-
Johnson, G. A., Cofer, G. P., Gewalt, S. L., & Hedlund, L. W. (2002). An engineering approach to image-based phenotyping. In 2002 Ieee International Symposium on Biomedical Imaging, Proceedings (pp. 381–383).Link to Item
-
Wetzel, A. W., Pomerantz, S., Nave, D., Meixner, W., & Johnson, G. A. (2001). Distributed multiuser visualization of time varying anatomical data. In Proceedings Applied Imagery Pattern Recognition Workshop (Vol. 2001-January, pp. 109–114). https://doi.org/10.1109/AIPR.2001.991211Full Text
-
MACFALL, J. S., & JOHNSON, G. A. (1994). NONDESTRUCTIVE, 3-DIMENSIONAL STUDY OF ROOT-GROWTH WITH MAGNETIC-RESONANCE MICROSCOPY (MRM). In J. A. Vozzo (Ed.), Research and Applications of Chemical Sciences in Forestry (Vol. 104, pp. 18–18). STARKVILLE, MS: US DEPT AGR, FOREST SERV SO FOREST EXPT STN.Link to Item
-
MACFALL, J. S., SPAINE, P. C., DOUDRICK, R. E., & JOHNSON, G. A. (1994). MAGNETIC-RESONANCE MICROSCOPY (MRM) OF WATER TRANSPORT AND BINDING IN FUSIFORM RUST GALLS. In J. A. Vozzo (Ed.), Research and Applications of Chemical Sciences in Forestry (Vol. 104, pp. 17–17). STARKVILLE, MS: US DEPT AGR, FOREST SERV SO FOREST EXPT STN.Link to Item
-
SPAINE, P., MACFALL, J. S., & JOHNSON, G. A. (1994). MAGNETIC-RESONANCE MICROSCOPY OF WATER-MOVEMENT THROUGH FUSIFORM RUST GALLS OF PINE. In Research and Applications of Chemical Sciences in Forestry (Vol. 104, pp. 11–16).Link to Item
-
BENVENISTE, H., JOHNSON, G. A., KOZNIEWSKA, E., MAIESE, K., NARITOMI, H., POVLISHOCK, J. T., & HOSSMANN, K. A. (1993). EXCITOTOXICITY AND ISCHEMIA IN THE RAT-BRAIN STUDIED IN-VIVO WITH HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING. In M. Tomita, F. Mchedlishvili, W. Rosenblum, W. D. Heiss, & Y. Fukuuchi (Eds.), Microcirculatory Stasis in the Brain (Vol. 1031, pp. 369–376). TOKYO, JAPAN: ELSEVIER SCIENCE PUBL B V.Link to Item
-
Johnson, G. A., & O’Foghludha, F. (1980). Investigation of transmolybdenum fluorescent anodes for mammography. In Proceedings of Spie the International Society for Optical Engineering (Vol. 233, pp. 158–163). https://doi.org/10.1117/12.958917Full Text
-
-
Theses and Dissertations
-
- Teaching & Mentoring
-
Recent Courses
-
Advising & Mentoring
-
Dr. Johnson mentors PhD / Masters students from Duke Biomedical Engineering (BME), Medical Physics, Medical Scientist Training Program, Radiology residents on research rotations, and post-doctoral fellows. He also mentors undergrads working on honors thesis projects, independent studies, and he develops specific projects for students interested in various aspects of small animal imaging research.
CURRENT PhD STUDENTS
•K Decker (Pre-PhD BME)
PREVIOUS PhD STUDENTS (descending order)
•R Dibb PhD (BME 2016) •D Clark PhD (BME 2015) •E Calabrese MD/PhD (BME 2014) •L Xie PhD (BME 2014) •E Subashi PhD (Med Physics 2014) •G Howles MD/PhD (BME 2010) •P Pandit (BME 2010) •J Nouls (BME 2009) •E Bucholz (BME 2008) •MD Lin PhD (2008) •N Mistry PhD (BME 2008) •J Song (Elec Comp Eng 2008) •A Petiet (BME 2007) •AA Sharief (BME 2006) •ACS Brau PhD (BME 2003) •A Nugent PhD (Physics 2003) •MS Chawla PhD (BME 2000) •S Hurlston PhD (BME 2000) •XJ Chen PhD (Physics 1999) •MD Shattuck PhD (Physics 1995) •RT Engelhardt PhD (Physics 1995) •JH Maki MD PhD (BME 1991) •T Winter PhD (Physics 1986)
PREVIOUS RADIOLOGY RESIDENTS / FELLOWS
•C Long MD/PhD (2015) •M Langman MD (2015) •EJ Langman MD (2013) •N Befera MD (2013) •S Shofer MD (2008) •WL Hall MD (1995) •M Banson MD (1992) •L Ardner MD (1994) •AF Mellin MD (1994) •JCM Hsu MD (1993) •SE Dockery MD (1991) •T Farmer MD (1990) •TW Malisch MD (1990) •CH Maynor MD (1989) •CF Beaulieu MD (1989) •MD Hollett MD (1988) •EK Fram MD (1987) •SN Bone MD (1987) •EK Fram MD (1987) •JP Karis (1987) •HP McAdams MD (1986) •R Sherrier MD (1985) •JT Douglas MD (1984)
Available to mentor:
- Masters
- PhD
- Post-Doc
- Resident
- Undergraduate
-
Dr. Johnson mentors PhD / Masters students from Duke Biomedical Engineering (BME), Medical Physics, Medical Scientist Training Program, Radiology residents on research rotations, and post-doctoral fellows. He also mentors undergrads working on honors thesis projects, independent studies, and he develops specific projects for students interested in various aspects of small animal imaging research.
- Scholarly, Clinical, & Service Activities
-
Service to the Profession
Some information on this profile has been compiled automatically from Duke databases and external sources. (Our About page explains how this works.) If you see a problem with the information, please write to Scholars@Duke and let us know. We will reply promptly.