WE‐C‐AUD B‐05: Predicting Radiation‐Induced Cardiac Perfusion Defects Using a Fusion Model

Published

Conference Paper

Purpose: To predict radiation‐induced cardiac perfusion defects using a fusion model that combines the results of four separate models: feed‐forward neural networks (NNET), self‐organizing maps (SOM), support vector machines (SVM), and multivariate adaptive regression splines (MARS). Method and Materials: The database comprised 111 patients with left‐sided breast treated with radiotherapy (56 diagnosed with cardiac perfusion defects post‐radiotherapy). The four independent models (NNET, SOM, SVM, and MARS) were constructed using a small number of independently selected features. The four models were then fused to a final model by averaging their patient predictions. Patient predictions were generated by testing the models using ten‐fold cross‐validation, wherein 1/10 th of the data were tested, in turn, using models built with the remaining 9/10 th of the data. To account for the variance in patient predictions caused by the effect of data splitting, 10‐fold cross validation was repeated 100 times with random data splitting. Results: For the fused model, the area under the Receiver Operating Characteristics (ROC) curve for cross‐validated testing was 0.890±0.012 (sensitivity = 80.6±1.7%, specificity = 80.2±1.7%). It was superior to the individual models (NNET: ROC = 0.764±0.015, sensitivity = 72.9±1.5%, specificity = 72.4±1.6%; SOM: ROC = 0.769±0.013, sensitivity = 73.0±1.4%, specificity = 72.2±1.5%; SVM: ROC = 0.900±0.048, sensitivity = 87.3±6.2%, specificity = 86.0±6.1%; MARS: ROC = 0.802±0.009, sensitivity = 76.1±1.1%, specificity = 75.6±1.1%) either in regard to higher predictive capability or lower variance. The fused model identified the following features as most important in predicting radiation‐induced perfusion defects: generalized equivalent uniform dose (EUD) with exponent a = 0.7, 1.0, and 3.6, and hypertension. Other features such as V46, V47, obesity, pack years, and chemotherapy played a less important role. Conclusion: The fused model provides promise for prospectively predicting radiation‐induced cardiac perfusion defects with high accuracy and confidence (low variance). © 2008, American Association of Physicists in Medicine. All rights reserved.

Full Text

Duke Authors

Cited Authors

  • Chen, S; Zhou, S; Hubbs, J; Wong, T; Borges‐neto, S; Yin, F; Marks, L; Das, S

Published Date

  • January 1, 2008

Published In

Volume / Issue

  • 35 / 6

Start / End Page

  • 2934 -

International Standard Serial Number (ISSN)

  • 0094-2405

Digital Object Identifier (DOI)

  • 10.1118/1.2962692

Citation Source

  • Scopus