Skip to main content

Bispectral index monitoring during sedation with sevoflurane, midazolam, and propofol

Publication ,  Journal Article
Ibrahim, AE; Taraday, JK; Kharasch, ED
Published in: Anesthesiology
January 1, 2001

Background: Bispectral Index (BIS) has been used to measure sedation depth. Ideally, to guide anesthetic management, range of BIS scores at different sedation levels should not overlap, and BIS should be independent of drug used. This study assessed ability of BIS to predict sedation depth between sevoflurane, propofol, and midazolam. Quality of recovery was also compared. Methods: Patients undergoing surgery with local or regional anesthesia and sedation were randomized to sevoflurane (n = 23), midazolam (n = 21), or propofol (n = 22). Sedation was titrated to Observers's Assessment of Alertness-Sedation score of 3 (responds slowly to voice). BIS and Observers's Assessment of Alertness-Sedation were measured every 5 min. BIS prediction probability (PK) was compared between drugs. Recovery was assessed by BIS and Digit Symbol Substitution and memory tests. Results: Bispectral Index of responders to voice was significantly different from nonresponders (86 ± 10 vs. 74 ± 14, mean ± SD; P < 0.001) However, wide variability and overlap in BIS were observed (25th-75th percentile, responders vs. non-responders: 79-96 vs. 65-83). BIS of responders was different for sevoflurane versus propofol and midazolam. BIS was a better predictor of propofol sedation than sevoflurane or midazolam (PK = 0.87 ± 0.11, 0.76 ± 0.01, and 0.69 ± 0.02, respectively; P < 0.05). At 10 min after the procedure, 76, 48, and 24% of sevoflurane, propofol, midazolam patients, respectively, returned to baseline Digit Symbol Substitution scores (P < 0.05). Excitement-disinhibition occurred in 70, 36, and 5% of sevoflurane, propofol, and midazolam patients, respectively (P < 0.05). Conclusion: Individual BIS scores demonstrate significant variability, making it difficult to predict sedation depth. The relation between BIS and sedation depth may not be independent of anesthetic agent. Quality of recovery was similar between drugs, but excitement occurred frequently with sevoflurane.

Duke Scholars

Published In

Anesthesiology

DOI

ISSN

0003-3022

Publication Date

January 1, 2001

Volume

95

Issue

5

Start / End Page

1151 / 1159

Related Subject Headings

  • Anesthesiology
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ibrahim, A. E., Taraday, J. K., & Kharasch, E. D. (2001). Bispectral index monitoring during sedation with sevoflurane, midazolam, and propofol. Anesthesiology, 95(5), 1151–1159. https://doi.org/10.1097/00000542-200111000-00019
Ibrahim, A. E., J. K. Taraday, and E. D. Kharasch. “Bispectral index monitoring during sedation with sevoflurane, midazolam, and propofol.” Anesthesiology 95, no. 5 (January 1, 2001): 1151–59. https://doi.org/10.1097/00000542-200111000-00019.
Ibrahim AE, Taraday JK, Kharasch ED. Bispectral index monitoring during sedation with sevoflurane, midazolam, and propofol. Anesthesiology. 2001 Jan 1;95(5):1151–9.
Ibrahim, A. E., et al. “Bispectral index monitoring during sedation with sevoflurane, midazolam, and propofol.” Anesthesiology, vol. 95, no. 5, Jan. 2001, pp. 1151–59. Scopus, doi:10.1097/00000542-200111000-00019.
Ibrahim AE, Taraday JK, Kharasch ED. Bispectral index monitoring during sedation with sevoflurane, midazolam, and propofol. Anesthesiology. 2001 Jan 1;95(5):1151–1159.

Published In

Anesthesiology

DOI

ISSN

0003-3022

Publication Date

January 1, 2001

Volume

95

Issue

5

Start / End Page

1151 / 1159

Related Subject Headings

  • Anesthesiology
  • 3202 Clinical sciences
  • 1103 Clinical Sciences