Skip to main content

Contrast-Enhanced In-Phase Dixon Sequence: Impact on Biopsy Clip Detection on Breast MRI.

Publication ,  Journal Article
Taylor-Cho, MW; Robertson, SH; Knight, JR; Miller, MM; Baker, JA
Published in: AJR Am J Roentgenol
March 2023

BACKGROUND. Identification of breast biopsy clips using conventional MRI sequences may be challenging. A contrast-enhanced in-phase Dixon sequence may have greater conspicuity for areas of susceptibility compared with standard clinical sequences. OBJECTIVE. The purpose of this article is to compare detection of breast biopsy clips on MRI between the contrast-enhanced in-phase Dixon sequence and three routine clinical sequences. METHODS. This retrospective study included 164 patients (mean age, 50.3 years) with a total of 281 breast biopsy clips who underwent contrast-enhanced breast MRI between January 2, 2019, and April 16, 2020. Three radiologists, blinded to the clip location and sequence used, independently annotated biopsy clip locations on three clinical sequences (T1-weighted non-fat-suppressed [NFS], STIR, and first phase from dynamic contrast-enhanced T1-weighted fat-suppressed [FS]) and on a contrast-enhanced in-phase Dixon sequence and then recorded confidence scores (1-4 scale). A study coordinator used all available imaging and reports to localize clips on MRI, which served as the reference standard. A physicist measured clip CNR. Sequences were compared using the McNemar test and two-tailed Wilcoxon signed rank tests. RESULTS. Among the three readers, pooled sensitivity and PPV were 78.2% and 96.2% for T1-weighted NFS, 26.6% and 92.7% for STIR, 61.7% and 95.9% for contrast-enhanced T1-weighted FS, and 85.1% and 95.1% for contrast-enhanced in-phase Dixon sequence. Pooled sensitivity was higher for contrast-enhanced in-phase Dixon sequence than for the other sequences (all p < .05); pooled PPV was not significantly different between contrast-enhanced in-phase Dixon and the other sequences (all p > .05). Mean confidence scores (pooled across readers for true-positive assessments) and mean CNR were 3.0 ± 0.9 (SD) and 1.21 ± 0.61 for T1-weighted NFS, 1.7 ± 0.9 and 0.57 ± 0.69 for STIR, 2.5 ± 1.0 and 0.54 ± 0.61 for contrast-enhanced T1-weighted FS, and 3.5 ± 0.8 and 4.05 ± 2.6 for the contrast-enhanced in-phase Dixon sequence. Pooled mean confidence scores and CNR were higher for contrast-enhanced in-phase Dixon than for the other sequences (all p < .001). CONCLUSION. Compared with clinical sequences, the contrast-enhanced in-phase Dixon sequence had higher sensitivity for detecting breast biopsy clips on MRI and higher reader confidence and CNR, without change in PPV. CLINICAL IMPACT. The contrast-enhanced in-phase Dixon sequence may help address a current challenge in clinical breast MRI interpretation.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

AJR Am J Roentgenol

DOI

EISSN

1546-3141

Publication Date

March 2023

Volume

220

Issue

3

Start / End Page

347 / 356

Location

United States

Related Subject Headings

  • Retrospective Studies
  • Radiography
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Magnetic Resonance Imaging
  • Humans
  • Breast
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Taylor-Cho, M. W., Robertson, S. H., Knight, J. R., Miller, M. M., & Baker, J. A. (2023). Contrast-Enhanced In-Phase Dixon Sequence: Impact on Biopsy Clip Detection on Breast MRI. AJR Am J Roentgenol, 220(3), 347–356. https://doi.org/10.2214/AJR.22.28024
Taylor-Cho, Michael W., Scott H. Robertson, John R. Knight, Matthew M. Miller, and Jay A. Baker. “Contrast-Enhanced In-Phase Dixon Sequence: Impact on Biopsy Clip Detection on Breast MRI.AJR Am J Roentgenol 220, no. 3 (March 2023): 347–56. https://doi.org/10.2214/AJR.22.28024.
Taylor-Cho MW, Robertson SH, Knight JR, Miller MM, Baker JA. Contrast-Enhanced In-Phase Dixon Sequence: Impact on Biopsy Clip Detection on Breast MRI. AJR Am J Roentgenol. 2023 Mar;220(3):347–56.
Taylor-Cho, Michael W., et al. “Contrast-Enhanced In-Phase Dixon Sequence: Impact on Biopsy Clip Detection on Breast MRI.AJR Am J Roentgenol, vol. 220, no. 3, Mar. 2023, pp. 347–56. Pubmed, doi:10.2214/AJR.22.28024.
Taylor-Cho MW, Robertson SH, Knight JR, Miller MM, Baker JA. Contrast-Enhanced In-Phase Dixon Sequence: Impact on Biopsy Clip Detection on Breast MRI. AJR Am J Roentgenol. 2023 Mar;220(3):347–356.

Published In

AJR Am J Roentgenol

DOI

EISSN

1546-3141

Publication Date

March 2023

Volume

220

Issue

3

Start / End Page

347 / 356

Location

United States

Related Subject Headings

  • Retrospective Studies
  • Radiography
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Magnetic Resonance Imaging
  • Humans
  • Breast
  • 3202 Clinical sciences
  • 1103 Clinical Sciences