Skip to main content
Journal cover image

Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome.

Publication ,  Conference
Acute Respiratory Distress Syndrome Network, ; Brower, RG; Matthay, MA; Morris, A; Schoenfeld, D; Thompson, BT; Wheeler, A
Published in: N Engl J Med
May 4, 2000

BACKGROUND: Traditional approaches to mechanical ventilation use tidal volumes of 10 to 15 ml per kilogram of body weight and may cause stretch-induced lung injury in patients with acute lung injury and the acute respiratory distress syndrome. We therefore conducted a trial to determine whether ventilation with lower tidal volumes would improve the clinical outcomes in these patients. METHODS: Patients with acute lung injury and the acute respiratory distress syndrome were enrolled in a multicenter, randomized trial. The trial compared traditional ventilation treatment, which involved an initial tidal volume of 12 ml per kilogram of predicted body weight and an airway pressure measured after a 0.5-second pause at the end of inspiration (plateau pressure) of 50 cm of water or less, with ventilation with a lower tidal volume, which involved an initial tidal volume of 6 ml per kilogram of predicted body weight and a plateau pressure of 30 cm of water or less. The primary outcomes were death before a patient was discharged home and was breathing without assistance and the number of days without ventilator use from day 1 to day 28. RESULTS: The trial was stopped after the enrollment of 861 patients because mortality was lower in the group treated with lower tidal volumes than in the group treated with traditional tidal volumes (31.0 percent vs. 39.8 percent, P=0.007), and the number of days without ventilator use during the first 28 days after randomization was greater in this group (mean [+/-SD], 12+/-11 vs. 10+/-11; P=0.007). The mean tidal volumes on days 1 to 3 were 6.2+/-0.8 and 11.8+/-0.8 ml per kilogram of predicted body weight (P<0.001), respectively, and the mean plateau pressures were 25+/-6 and 33+/-8 cm of water (P<0.001), respectively. CONCLUSIONS: In patients with acute lung injury and the acute respiratory distress syndrome, mechanical ventilation with a lower tidal volume than is traditionally used results in decreased mortality and increases the number of days without ventilator use.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

N Engl J Med

DOI

ISSN

0028-4793

Publication Date

May 4, 2000

Volume

342

Issue

18

Start / End Page

1301 / 1308

Location

United States

Related Subject Headings

  • Tidal Volume
  • Survival Analysis
  • Respiratory Distress Syndrome
  • Respiration, Artificial
  • Positive-Pressure Respiration
  • Middle Aged
  • Male
  • Lung Injury
  • Humans
  • General & Internal Medicine
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Acute Respiratory Distress Syndrome Network, ., Brower, R. G., Matthay, M. A., Morris, A., Schoenfeld, D., Thompson, B. T., & Wheeler, A. (2000). Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. In N Engl J Med (Vol. 342, pp. 1301–1308). United States. https://doi.org/10.1056/NEJM200005043421801
Acute Respiratory Distress Syndrome Network, Arthur, Roy G. Brower, Michael A. Matthay, Alan Morris, David Schoenfeld, B Taylor Thompson, and Arthur Wheeler. “Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome.” In N Engl J Med, 342:1301–8, 2000. https://doi.org/10.1056/NEJM200005043421801.
Acute Respiratory Distress Syndrome Network, Brower RG, Matthay MA, Morris A, Schoenfeld D, Thompson BT, et al. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. In: N Engl J Med. 2000. p. 1301–8.
Acute Respiratory Distress Syndrome Network, Arthur, et al. “Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome.N Engl J Med, vol. 342, no. 18, 2000, pp. 1301–08. Pubmed, doi:10.1056/NEJM200005043421801.
Acute Respiratory Distress Syndrome Network, Brower RG, Matthay MA, Morris A, Schoenfeld D, Thompson BT, Wheeler A. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000. p. 1301–1308.
Journal cover image

Published In

N Engl J Med

DOI

ISSN

0028-4793

Publication Date

May 4, 2000

Volume

342

Issue

18

Start / End Page

1301 / 1308

Location

United States

Related Subject Headings

  • Tidal Volume
  • Survival Analysis
  • Respiratory Distress Syndrome
  • Respiration, Artificial
  • Positive-Pressure Respiration
  • Middle Aged
  • Male
  • Lung Injury
  • Humans
  • General & Internal Medicine