Analysis of uncertainties in Monte Carlo simulated organ dose for chest CT

Publication ,  Conference
Muryn, JS; Morgan, AG; Segars, WP; Liptak, CL; Dong, FF; Primak, AN; Li, X
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
January 1, 2015

In Monte Carlo simulation of organ dose for a chest CT scan, many input parameters are required (e.g., half-value layer of the x-ray energy spectrum, effective beam width, and anatomical coverage of the scan). The input parameter values are provided by the manufacturer, measured experimentally, or determined based on typical clinical practices. The goal of this study was to assess the uncertainties in Monte Carlo simulated organ dose as a result of using input parameter values that deviate from the truth (clinical reality). Organ dose from a chest CT scan was simulated for a standard-size female phantom using a set of reference input parameter values (treated as the truth). To emulate the situation in which the input parameter values used by the researcher may deviate from the truth, additional simulations were performed in which errors were purposefully introduced into the input parameter values, the effects of which on organ dose per CTDIvol were analyzed. Our study showed that when errors in half value layer were within ± 0.5 mm Al, the errors in organ dose per CTDIvol were less than 6%. Errors in effective beam width of up to 3 mm had negligible effect (< 2.5%) on organ dose. In contrast, when the assumed anatomical center of the patient deviated from the true anatomical center by 5 cm, organ dose errors of up to 20% were introduced. Lastly, when the assumed extra scan length was longer by 4 cm than the true value, dose errors of up to 160% were found. The results answer the important question: to what level of accuracy each input parameter needs to be determined in order to obtain accurate organ dose results.

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

ISBN

9781628415025

Publication Date

January 1, 2015

Volume

9412
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Muryn, J. S., Morgan, A. G., Segars, W. P., Liptak, C. L., Dong, F. F., Primak, A. N., & Li, X. (2015). Analysis of uncertainties in Monte Carlo simulated organ dose for chest CT. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE (Vol. 9412). https://doi.org/10.1117/12.2076067
Muryn, J. S., A. G. Morgan, W. P. Segars, C. L. Liptak, F. F. Dong, A. N. Primak, and X. Li. “Analysis of uncertainties in Monte Carlo simulated organ dose for chest CT.” In Progress in Biomedical Optics and Imaging - Proceedings of SPIE, Vol. 9412, 2015. https://doi.org/10.1117/12.2076067.
Muryn JS, Morgan AG, Segars WP, Liptak CL, Dong FF, Primak AN, et al. Analysis of uncertainties in Monte Carlo simulated organ dose for chest CT. In: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2015.
Muryn, J. S., et al. “Analysis of uncertainties in Monte Carlo simulated organ dose for chest CT.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 9412, 2015. Scopus, doi:10.1117/12.2076067.
Muryn JS, Morgan AG, Segars WP, Liptak CL, Dong FF, Primak AN, Li X. Analysis of uncertainties in Monte Carlo simulated organ dose for chest CT. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2015.
Journal cover image

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

ISBN

9781628415025

Publication Date

January 1, 2015

Volume

9412