Cytotoxicity and thermomechanical behavior of biomedical shape-memory polymer networks post-sterilization.

Publication ,  Journal Article
Yakacki, CM; Lyons, MB; Rech, B; Gall, K; Shandas, R
Published in: Biomedical materials (Bristol, England)
March 2008

Shape-memory polymers (SMPs) are being increasingly proposed for use in biomedical devices. This paper investigates the cytotoxicity, surface characteristics and thermomechanics of two acrylate-based SMP networks as a function of sterilization using a minimal essential media elution test, FTIR-ATR and dynamic mechanical analysis (DMA). Networks sterilized by low-temperature plasma elicited a cytotoxic response and are shown to completely destroy the cell monolayer. FTIR-ATR analysis showed evidence of surface oxidation with an increase and broadening of the absorbance peak from approximately 3500 to 3100 cm(-1), which is associated with an increase in hydroxyl groups. DMA revealed small, but statistically significant, differences in reduction of the glass transition temperatures of both networks when sterilized with gamma irradiation. One network showed an increase in rubbery modulus, which is an indication of crosslink density, after gamma irradiation. Lastly, practical sterilization concerns of SMP devices are discussed in light of the different methods.

Duke Scholars

Published In

Biomedical materials (Bristol, England)

DOI

EISSN

1748-605X

ISSN

1748-6041

Publication Date

March 2008

Volume

3

Issue

1

Start / End Page

015010

Related Subject Headings

  • Thermodynamics
  • Stress, Mechanical
  • Sterilization
  • Polymers
  • Molecular Conformation
  • Materials Testing
  • Elasticity
  • Cell Survival
  • Biomedical Engineering
  • Biocompatible Materials
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Yakacki, C. M., Lyons, M. B., Rech, B., Gall, K., & Shandas, R. (2008). Cytotoxicity and thermomechanical behavior of biomedical shape-memory polymer networks post-sterilization. Biomedical Materials (Bristol, England), 3(1), 015010. https://doi.org/10.1088/1748-6041/3/1/015010
Yakacki, C. M., M. B. Lyons, B. Rech, K. Gall, and R. Shandas. “Cytotoxicity and thermomechanical behavior of biomedical shape-memory polymer networks post-sterilization.Biomedical Materials (Bristol, England) 3, no. 1 (March 2008): 015010. https://doi.org/10.1088/1748-6041/3/1/015010.
Yakacki CM, Lyons MB, Rech B, Gall K, Shandas R. Cytotoxicity and thermomechanical behavior of biomedical shape-memory polymer networks post-sterilization. Biomedical materials (Bristol, England). 2008 Mar;3(1):015010.
Yakacki, C. M., et al. “Cytotoxicity and thermomechanical behavior of biomedical shape-memory polymer networks post-sterilization.Biomedical Materials (Bristol, England), vol. 3, no. 1, Mar. 2008, p. 015010. Epmc, doi:10.1088/1748-6041/3/1/015010.
Yakacki CM, Lyons MB, Rech B, Gall K, Shandas R. Cytotoxicity and thermomechanical behavior of biomedical shape-memory polymer networks post-sterilization. Biomedical materials (Bristol, England). 2008 Mar;3(1):015010.
Journal cover image

Published In

Biomedical materials (Bristol, England)

DOI

EISSN

1748-605X

ISSN

1748-6041

Publication Date

March 2008

Volume

3

Issue

1

Start / End Page

015010

Related Subject Headings

  • Thermodynamics
  • Stress, Mechanical
  • Sterilization
  • Polymers
  • Molecular Conformation
  • Materials Testing
  • Elasticity
  • Cell Survival
  • Biomedical Engineering
  • Biocompatible Materials