Enhanced method performance due to a shorter chromatographic run-time in a liquid chromatography-tandem mass spectrometry assay for paclitaxel.

Publication ,  Journal Article
Mortier, KA; Verstraete, AG; Zhang, G-F; Lambert, WE
Published in: J Chromatogr A
July 2, 2004

Liquid chromatography-tandem mass spectrometry (LC-MS-MS) is often performed in a high-throughput environment. Unfortunately, with atmospheric pressure ionization (API) techniques, shorter run-times or reduced sample clean-up often result in ion or matrix suppression, which can lead to erroneous results. The present work on the analysis of paclitaxel compares ion suppression, sensitivity and linearity of a high-throughput LC-MS-MS method (0.8 min run-time, method B) to a method with increased separation (2.0 min run-time, method A). An atmospheric pressure chemical ionization (APCI) interface was used for both methods. The high-sample-throughput method uses an increased amount of organic solvent in the mobile phase (isocratic, 85% versus 70% of methanol) and a higher flow-rate (600 microl/min versus 400 micro/min). As a result, internal standard (docetaxel) and target analyte (paclitaxel) co-elute, close to, although separated from the solvent front. Ion suppression of both methods was evaluated by comparing pure standard to plasma and plasma containing a vehicle. Sensitivity and linearity were compared by injecting matrix matched calibration samples with both methods. Ion suppression by the vehicle Cremophor EL led to poor data quality for the standard method (A), while for the short method (B), ion suppression was compensated for by the co-eluting internal standard. The short method showed similar linearity but increased sensitivity by at least a factor five. This work provides a strategy to compensate for ion suppression without the use of labeled internal standards. In addition, a better sensitivity and a shorter run-time are noted.

Duke Scholars

Published In

J Chromatogr A

DOI

ISSN

0021-9673

Publication Date

July 2, 2004

Volume

1041

Issue

1-2

Start / End Page

235 / 238

Location

Netherlands

Related Subject Headings

  • Taxoids
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Reference Standards
  • Paclitaxel
  • Mass Spectrometry
  • Humans
  • Docetaxel
  • Chromatography, High Pressure Liquid
  • Atmospheric Pressure
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mortier, K. A., Verstraete, A. G., Zhang, G.-F., & Lambert, W. E. (2004). Enhanced method performance due to a shorter chromatographic run-time in a liquid chromatography-tandem mass spectrometry assay for paclitaxel. J Chromatogr A, 1041(1–2), 235–238. https://doi.org/10.1016/j.chroma.2004.04.026
Mortier, Kjell A., Alain G. Verstraete, Guo-Fang Zhang, and Willy E. Lambert. “Enhanced method performance due to a shorter chromatographic run-time in a liquid chromatography-tandem mass spectrometry assay for paclitaxel.J Chromatogr A 1041, no. 1–2 (July 2, 2004): 235–38. https://doi.org/10.1016/j.chroma.2004.04.026.
Mortier KA, Verstraete AG, Zhang G-F, Lambert WE. Enhanced method performance due to a shorter chromatographic run-time in a liquid chromatography-tandem mass spectrometry assay for paclitaxel. J Chromatogr A. 2004 Jul 2;1041(1–2):235–8.
Mortier, Kjell A., et al. “Enhanced method performance due to a shorter chromatographic run-time in a liquid chromatography-tandem mass spectrometry assay for paclitaxel.J Chromatogr A, vol. 1041, no. 1–2, July 2004, pp. 235–38. Pubmed, doi:10.1016/j.chroma.2004.04.026.
Mortier KA, Verstraete AG, Zhang G-F, Lambert WE. Enhanced method performance due to a shorter chromatographic run-time in a liquid chromatography-tandem mass spectrometry assay for paclitaxel. J Chromatogr A. 2004 Jul 2;1041(1–2):235–238.
Journal cover image

Published In

J Chromatogr A

DOI

ISSN

0021-9673

Publication Date

July 2, 2004

Volume

1041

Issue

1-2

Start / End Page

235 / 238

Location

Netherlands

Related Subject Headings

  • Taxoids
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Reference Standards
  • Paclitaxel
  • Mass Spectrometry
  • Humans
  • Docetaxel
  • Chromatography, High Pressure Liquid
  • Atmospheric Pressure