Surgical robots are gaining favor in part due to their capacity to reach remote locations within the body. Continuum robots are especially well suited for accessing deep spaces such as cerebral ventricles within the brain. Due to the entry point constraints and complicated structure, current techniques do not allow surgeons to access the full volume of the ventricles. The ability to access the ventricles with a dexterous robot would have significant clinical implications. This paper presents a concentric tube manipulator mated to a robotically controlled flexible endoscope. The device adds three degrees of freedom to the standard neuroendoscope and roboticizes the entire package allowing the operator to conveniently manipulate the device. To demonstrate the improved functionality, we use an in-silica virtual model as well as an ex-vivo anatomic model of a patient with a treatable form of hydrocephalus. In these experiments we demonstrate that the augmented and roboticized endoscope can efficiently reach critical regions that a manual scope cannot. © 2012 IEEE.

Duke Scholars

Published In

IEEE International Conference on Intelligent Robots and Systems

DOI

EISSN

2153-0866

ISSN

2153-0858

Publication Date

December 1, 2012

Start / End Page

2941 / 2946
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Butler, E. J., Hammond-Oakley, R., Chawarski, S., Gosline, A. H., Codd, P., Anor, T., … Lock, J. (2012). Robotic neuro-emdoscope with concentric tube augmentation. IEEE International Conference on Intelligent Robots and Systems, 2941–2946. https://doi.org/10.1109/IROS.2012.6386022
Butler, E. J., R. Hammond-Oakley, S. Chawarski, A. H. Gosline, P. Codd, T. Anor, J. R. Madsen, P. E. Dupont, and J. Lock. “Robotic neuro-emdoscope with concentric tube augmentation.” IEEE International Conference on Intelligent Robots and Systems, December 1, 2012, 2941–46. https://doi.org/10.1109/IROS.2012.6386022.
Butler EJ, Hammond-Oakley R, Chawarski S, Gosline AH, Codd P, Anor T, et al. Robotic neuro-emdoscope with concentric tube augmentation. IEEE International Conference on Intelligent Robots and Systems. 2012 Dec 1;2941–6.
Butler, E. J., et al. “Robotic neuro-emdoscope with concentric tube augmentation.” IEEE International Conference on Intelligent Robots and Systems, Dec. 2012, pp. 2941–46. Scopus, doi:10.1109/IROS.2012.6386022.
Butler EJ, Hammond-Oakley R, Chawarski S, Gosline AH, Codd P, Anor T, Madsen JR, Dupont PE, Lock J. Robotic neuro-emdoscope with concentric tube augmentation. IEEE International Conference on Intelligent Robots and Systems. 2012 Dec 1;2941–2946.

Published In

IEEE International Conference on Intelligent Robots and Systems

DOI

EISSN

2153-0866

ISSN

2153-0858

Publication Date

December 1, 2012

Start / End Page

2941 / 2946