Skip to main content
Journal cover image

Phase-updated regularized SENSE for navigator-free multishot diffusion imaging.

Publication ,  Journal Article
Hu, Z; Ma, X; Truong, T-K; Song, AW; Guo, H
Published in: Magn Reson Med
July 2017

PURPOSE: Either SENSE+CG or POCS-ICE methods can be used to correct for motion-induced phase errors in navigator-free multishot diffusion imaging. SENSE+CG has the advantage of a fast convergence, however, occasionally the convergence can be unstable, thus degrading the image quality. POCS-ICE has a stable convergence and can be used with a high number of shots, but its convergence is slow, which limits its practical usage. The study here proposes an improved method based on both SENSE+CG and POCS-ICE, called Phase-updated Regularized SENSE (PR-SENSE), for navigator-free multishot diffusion imaging. THEORY AND METHODS: In PR-SENSE, a total variation regularization method is used to solve the SENSE inverse problem instead of the conjugate gradient method used in SENSE+CG. This method is implemented by using a lagged diffusivity fixed point iteration algorithm. Additionally, the phase is updated during the iteration process to improve the image accuracy. RESULTS: Simulations and in vivo experiments demonstrated that PR-SENSE can successfully correct for the motion-induced phase errors in multi-shot DWI. It integrates the advantages of SENSE+CG and POCS-ICE, resulting in a fast and stable convergence with improved image quality. CONCLUSION: Given its advantages, PR-SENSE is a significant improvement over other methods for navigator-free high-resolution DWI. Magn Reson Med 78:172-181, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

July 2017

Volume

78

Issue

1

Start / End Page

172 / 181

Location

United States

Related Subject Headings

  • Signal Processing, Computer-Assisted
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Nuclear Medicine & Medical Imaging
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
  • Humans
  • Diffusion Magnetic Resonance Imaging
  • Brain
  • Algorithms
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hu, Z., Ma, X., Truong, T.-K., Song, A. W., & Guo, H. (2017). Phase-updated regularized SENSE for navigator-free multishot diffusion imaging. Magn Reson Med, 78(1), 172–181. https://doi.org/10.1002/mrm.26361
Hu, Zhangxuan, Xiaodong Ma, Trong-Kha Truong, Allen W. Song, and Hua Guo. “Phase-updated regularized SENSE for navigator-free multishot diffusion imaging.Magn Reson Med 78, no. 1 (July 2017): 172–81. https://doi.org/10.1002/mrm.26361.
Hu Z, Ma X, Truong T-K, Song AW, Guo H. Phase-updated regularized SENSE for navigator-free multishot diffusion imaging. Magn Reson Med. 2017 Jul;78(1):172–81.
Hu, Zhangxuan, et al. “Phase-updated regularized SENSE for navigator-free multishot diffusion imaging.Magn Reson Med, vol. 78, no. 1, July 2017, pp. 172–81. Pubmed, doi:10.1002/mrm.26361.
Hu Z, Ma X, Truong T-K, Song AW, Guo H. Phase-updated regularized SENSE for navigator-free multishot diffusion imaging. Magn Reson Med. 2017 Jul;78(1):172–181.
Journal cover image

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

July 2017

Volume

78

Issue

1

Start / End Page

172 / 181

Location

United States

Related Subject Headings

  • Signal Processing, Computer-Assisted
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Nuclear Medicine & Medical Imaging
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
  • Humans
  • Diffusion Magnetic Resonance Imaging
  • Brain
  • Algorithms