Skip to main content

In vivo photoacoustic microscopy with 7.6-µm axial resolution using a commercial 125-MHz ultrasonic transducer.

Publication ,  Journal Article
Zhang, C; Maslov, K; Yao, J; Wang, LV
Published in: Journal of biomedical optics
November 2012

Photoacoustic microscopy has achieved submicron lateral resolution, but its axial resolution is much lower. Here an axial resolution of 7.6 μm, the highest axial resolution validated by experimental data, has been achieved by using a commercial 125 MHz ultrasonic transducer for signal detection followed by the Wiener deconvolution for signal processing. Limited by the working distance, the high-frequency ultrasonic transducer can penetrate 1.2 mm into biological tissue from the ultrasound detection side. At this depth, the signal-to-noise ratio decreases by 11 dB, and the axial resolution degrades by 36%. The new system was demonstrated in imaging melanoma cells ex vivo and mouse ears in vivo.

Duke Scholars

Published In

Journal of biomedical optics

DOI

EISSN

1560-2281

ISSN

1083-3668

Publication Date

November 2012

Volume

17

Issue

11

Start / End Page

116016

Related Subject Headings

  • Ultrasonics
  • Transducers
  • Signal-To-Noise Ratio
  • Signal Processing, Computer-Assisted
  • Optics
  • Optical Phenomena
  • Microscopy, Acoustic
  • Mice
  • Melanoma, Experimental
  • Equipment Design
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zhang, C., Maslov, K., Yao, J., & Wang, L. V. (2012). In vivo photoacoustic microscopy with 7.6-µm axial resolution using a commercial 125-MHz ultrasonic transducer. Journal of Biomedical Optics, 17(11), 116016. https://doi.org/10.1117/1.jbo.17.11.116016
Zhang, Chi, Konstantin Maslov, Junjie Yao, and Lihong V. Wang. “In vivo photoacoustic microscopy with 7.6-µm axial resolution using a commercial 125-MHz ultrasonic transducer.Journal of Biomedical Optics 17, no. 11 (November 2012): 116016. https://doi.org/10.1117/1.jbo.17.11.116016.
Zhang C, Maslov K, Yao J, Wang LV. In vivo photoacoustic microscopy with 7.6-µm axial resolution using a commercial 125-MHz ultrasonic transducer. Journal of biomedical optics. 2012 Nov;17(11):116016.
Zhang, Chi, et al. “In vivo photoacoustic microscopy with 7.6-µm axial resolution using a commercial 125-MHz ultrasonic transducer.Journal of Biomedical Optics, vol. 17, no. 11, Nov. 2012, p. 116016. Epmc, doi:10.1117/1.jbo.17.11.116016.
Zhang C, Maslov K, Yao J, Wang LV. In vivo photoacoustic microscopy with 7.6-µm axial resolution using a commercial 125-MHz ultrasonic transducer. Journal of biomedical optics. 2012 Nov;17(11):116016.

Published In

Journal of biomedical optics

DOI

EISSN

1560-2281

ISSN

1083-3668

Publication Date

November 2012

Volume

17

Issue

11

Start / End Page

116016

Related Subject Headings

  • Ultrasonics
  • Transducers
  • Signal-To-Noise Ratio
  • Signal Processing, Computer-Assisted
  • Optics
  • Optical Phenomena
  • Microscopy, Acoustic
  • Mice
  • Melanoma, Experimental
  • Equipment Design